1.
J Arthroplasty ; 28(8): 1291-6, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23523483

RESUMO

This was a prospective consecutive, study of 50 patients (mean age 72 years, 56% males) treated unilaterally for primary osteoarthrosis using the uncemented, isoelastic, monoblock RM Pressfit Cup. Migration and wear were assessed using the EBRA (Ein-Bild-Röntgen-Analyse) software (201 radiographs from 36 patients). Mean migration was 0.82 mm after 2 years and 1.25 mm after 5 years. A decreasing migration rate over the period was observed. The mean annual wear rate was 0.09 mm/y. Five years after surgery, 84% of patients reached good or excellent Harris hip score values. No revisions related to the acetabular component were necessary. All cups appeared to have high primary stability.


Assuntos
Artroplastia de Quadril , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril , Falha de Prótese , Idoso , Algoritmos , Feminino , Seguimentos , Articulação do Quadril/cirurgia , Humanos , Incidência , Instabilidade Articular/epidemiologia , Estudos Longitudinais , Masculino , Osteoartrite do Quadril/cirurgia , Estudos Prospectivos , Desenho de Prótese , Radiografia , Estudos Retrospectivos , Software , Resultado do Tratamento