Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Emerg Med J ; 35(7): 428-432, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29769232

RESUMO

BACKGROUND: Active compression-decompression (ACD) devices have enhanced end-tidal carbon dioxide (ETCO2) output in experimental cardiopulmonary resuscitation (CPR) studies. However, the results in out-of-hospital cardiac arrest (OHCA) patients have shown inconsistent outcomes, and earlier studies lacked quality control of CPR attempts. We compared manual CPR with ACD-CPR by measuring ETCO2 output using an audiovisual feedback defibrillator to ensure continuous high quality resuscitation attempts. METHODS: 10 witnessed OHCAs were resuscitated, rotating a 2 min cycle with manual CPR and a 2 min cycle of ACD-CPR. Patients were intubated and the ventilation rate was held constant during CPR. CPR quality parameters and ETCO2 values were collected continuously with the defibrillator. Differences in ETCO2 output between manual CPR and ACD-CPR were analysed using a linear mixed model where ETCO2 output produced by a summary of the 2 min cycles was included as the dependent variable, the patient as a random factor and method as a fixed effect. These comparisons were made within each OHCA case to minimise confounding factors between the cases. RESULTS: Mean length of the CPR episodes was 37 (SD 8) min. Mean compression depth was 76 (SD 1.3) mm versus 71 (SD1.0) mm, and mean compression rate was 100 per min (SD 6.7) versus 105 per min (SD 4.9) between ACD-CPR and manual CPR, respectively. For ETCO2 output, the interaction between the method and the patient was significant (P<0.001). ETCO2 output was higher with manual CPR in 6 of the 10 cases. CONCLUSIONS: This study suggests that quality controlled ACD-CPR is not superior to quality controlled manual CPR when ETCO2 is used as a quantitative measure of CPR effectiveness. TRIAL REGISTRATION NUMBER: NCT00951704; Results.


Assuntos
Dióxido de Carbono/análise , Reanimação Cardiopulmonar/instrumentação , Reanimação Cardiopulmonar/normas , Parada Cardíaca Extra-Hospitalar/terapia , Idoso , Idoso de 80 Anos ou mais , Dióxido de Carbono/sangue , Reanimação Cardiopulmonar/métodos , Competência Clínica/normas , Serviços Médicos de Emergência/classificação , Serviços Médicos de Emergência/métodos , Serviços Médicos de Emergência/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...