3.
Med Image Comput Comput Assist Interv ; 11(Pt 2): 155-62, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18982601

RESUMO

Respiratory motion is a source of degradation in positron emission tomography. As the patients cannot hold breath during the PET acquisition, spatial blurring and motion artifacts are unavoidable which may lead to wrong quantification of the data. A solution based on respiratory-gating and optical flow based correction of the PET data is proposed. This includes deformation of the CT data for accurate attenuation and listmode based reconstruction. All methods are applied to real patient data and are evaluated with respect to three criteria.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Imagem do Acúmulo Cardíaco de Comporta/métodos , Aumento da Imagem/métodos , Tomografia por Emissão de Pósitrons/métodos , Mecânica Respiratória , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Artefatos , Angiografia Coronária/métodos , Humanos , Movimento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...