Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Arch Orthop Trauma Surg ; 144(4): 1813-1820, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38217640

RESUMO

INTRODUCTION: The aim of this retrospective study was to analyze the clinical and functional outcome of a modular tapered revision hip stem after mid-term follow-up with a special focus on the length of the distal bicortical fixation of the cementless hip stem. MATERIALS AND METHODS: Follow-up examination was carried out for all patients with implantation of the Prevision hip stem between 2014 and 2019 to collect demographic, functional, and radiographic data. RESULTS: 44 patients with stem in situ were examined, and 61 patients could be included in the Kaplan-Meier survival analysis. Oxford's hip score was 37.3 at the mean follow-up of 4.0 years. Two hip stem revisions were performed due to periprosthetic infection, which resulted in a hip stem survival rate of 96.7% (CI: 87.4-99.1%) at the final follow-up of 7.5 years. No aseptic hip stem revision was required. The length of bicortical distal fixation was in the interquartile range of 6.8 to 9.0 cm, which was associated with good bone healing and a low rate of subsidence (4.5%). Implant-associated complications were observed in 10 cases (21.7%). CONCLUSIONS: The modular revision hip stem provides promising results at medium-term follow-up, with satisfactory clinical and functional outcomes comparable to other modular revision hip stems. The presented length of bicortical distal fixation shows the practice of the study center and was associated with good implant survival, bone healing and radiological results. REGISTRATION: Clinicaltrials.gov registration: NCT04833634 registered on April 6, 2021.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Estudos Retrospectivos , Falha de Prótese , Reoperação , Desenho de Prótese , Complicações Pós-Operatórias , Resultado do Tratamento , Seguimentos
2.
Cancers (Basel) ; 4(1): 141-55, 2012 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-24213232

RESUMO

The aim of this study was to assess the clinical sensitivities of the tumor markers chromogranin A (CgA), urinary 5-hydroxyindoleacetic acid (5-HIAA) and alkaline phosphatase (AP) in neuroendocrine tumors (NETs) of the GastroEnteroPancreatic-(GEP-) system depending on tumor primary location and metastatic spread. In a retrospective single-center series, sensitivities were evaluated in serum samples from 110 patients with midgut (n = 62) and pancreatic (n = 48) NETs. CgA levels were analyzed by a commercially-available immunoradiometric assay (CIS-bio) during routine follow-up in the years 2000-2009. CgA showed a higher sensitivity for midgut (68%) than pancreatic (54%) NETs. A higher CgA sensitivity and significantly higher median CgA values were found in patients with liver metastases than in those without, and in patients with hepatic and additionally extra-hepatic metastases than in those with hepatic and nodal metastases alone, respectively. We found an overall sensitivity for elevated 5HIAA excretion of 69% for midgut NETs and a significant correlation between median CgA and 5-HIAA values. The sensitivity of AP and the correlations of AP/CgA-data-pairs were low in both midgut and pancreatic NETs, although highest for metastatic pancreatic NETs. The sensitivity of CgA measurement depends on the NET primary location and spread of disease. 5-HIAA and CgA showed comparable sensitivity in midgut NETs, while AP does not seem to be useful as a tumor marker in GEP-NETs.

3.
BMC Nephrol ; 11: 6, 2010 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-20398419

RESUMO

BACKGROUND: Diarrhea is common in patients with Crohn's disease and may be accompanied by acid base disorders, most commonly metabolic acidosis due to intestinal loss of bicarbonate. CASE PRESENTATION: Here, we present a case of severe metabolic alkalosis in a young patient suffering from M. Crohn. The patient had undergone multiple resections of the intestine and suffered from chronic kidney disease. He was now referred to our clinic for recurrent acute kidney injury, the nature of which was pre-renal due to profound volume depletion. Renal failure was associated with marked hypochloremic metabolic alkalosis which only responded to high volume repletion and high dose blockade of gastric hypersecretion. Intestinal failure with stomal fluid losses of up to 5.7 litres per day required port implantation to commence parenteral nutrition. Fluid and electrolyte replacement rapidly improved renal function and acid base homeostasis. CONCLUSIONS: This case highlights the important role of gastrointestinal function to maintain acid base status in patients with Crohn's disease.


Assuntos
Alcalose/etiologia , Alcalose/fisiopatologia , Doença de Crohn/cirurgia , Procedimentos Cirúrgicos do Sistema Digestório/efeitos adversos , Insuficiência Renal/etiologia , Acrodermatite/etiologia , Acrodermatite/patologia , Doença Aguda , Adulto , Alcalose/terapia , Deficiências Nutricionais/complicações , Trânsito Gastrointestinal , Humanos , Lábio , Masculino , Nariz , Nutrição Parenteral , Recidiva , Insuficiência Renal/terapia , Índice de Gravidade de Doença , Zinco/deficiência
4.
Eur Radiol ; 16(11): 2512-20, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16670866

RESUMO

The objective of this study was to evaluate the accuracy of electrocardiography (ECG)-gated 16-slice multidetector-row computed tomography (MDCT) in detection of stenosis of bypass grafts and native coronary arteries in patients who have undergone coronary artery bypass grafting (CABG). ECG-gated contrast-enhanced MDCT using 12 x 0.75-mm collimation was performed in 20 patients with recurrent angina 4.75 years after undergoing CABG. A total of 50 grafts, 16 arterial and 34 venous, were examined. All graft and coronary segments were evaluated for stenosis in comparison with conventional coronary angiography (CCA). Among the 80 arterial graft segments, 62 could be assessed (77.5%). Sensitivity, specificity, and positive and negative predictive values for stenosis were 96.2%, 97.2%, 96.2%, and 97.2%, respectively. In a total of 180 venous graft segments, 167 could be assessed. Sensitivity, specificity, and positive and negative predictive values for stenosis were 98.5%, 93.9%, 91.8%, and 98.9%, respectively. MDCT could assess 179 of 260 native coronary artery segments (68.8%). Sensitivity, specificity, and positive and negative predictive values for stenosis were 92.1%, 76.9%, 87.5%, and 84.7%, respectively. Sixteen-slice MDCT provides excellent image quality and diagnostic accuracy in detection of graft and coronary artery lesions in patients with suspected graft dysfunction.


Assuntos
Angiografia Coronária , Ponte de Artéria Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/fisiopatologia , Tomografia Computadorizada por Raios X , Grau de Desobstrução Vascular , Angina Pectoris/diagnóstico por imagem , Angina Pectoris/fisiopatologia , Angina Pectoris/cirurgia , Calcinose/diagnóstico por imagem , Calcinose/etiologia , Calcinose/fisiopatologia , Meios de Contraste , Reestenose Coronária/etiologia , Eletrocardiografia , Alemanha , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Frequência Cardíaca , Humanos , Projetos de Pesquisa , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação , Resultado do Tratamento
5.
Am J Cardiol ; 97(3): 343-8, 2006 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-16442393

RESUMO

Eighty-four patients with suspected coronary artery disease were studied to determine the accuracy of noninvasive coronary angiography using a multidetector computed tomographic scanner with 64- x 0.6-mm collimation and 330-ms gantry rotation. All coronary artery segments with a diameter >1.5 mm were assessed with respect to stenoses >50% decreased diameter. Results were compared with quantitative coronary angiographic findings. After exclusion of unevaluable coronary segments (4%), multidetector computed tomography demonstrated a sensitivity of 93%, a specificity of 97%, and a negative predictive value of 100% in a per-segment analysis. In a per-artery analysis, 15 of 336 arteries (4%) were unevaluable. Sensitivity and specificity in evaluable arteries were 95% and 93%, respectively. In a per-patient analysis (81 of 84 patients included), sensitivity and specificity were 96% and 91%, respectively.


Assuntos
Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada Espiral/instrumentação , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
6.
Eur Radiol ; 16(2): 256-68, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16341833

RESUMO

We present a performance evaluation of a recently introduced dual-source computed tomography (DSCT) system equipped with two X-ray tubes and two corresponding detectors, mounted onto the rotating gantry with an angular offset of 90 degrees . We introduce the system concept and derive its consequences and potential benefits for electrocardiograph [corrected] (ECG)-controlled cardiac CT and for general radiology applications. We evaluate both temporal and spatial resolution by means of phantom scans. We present first patient scans to illustrate the performance of DSCT for ECG-gated cardiac imaging, and we demonstrate first results using a dual-energy acquisition mode. Using ECG-gated single-segment reconstruction, the DSCT system provides 83 ms temporal resolution independent of the patient's heart rate for coronary CT angiography (CTA) and evaluation of basic functional parameters. With dual-segment reconstruction, the mean temporal resolution is 60 ms (minimum temporal resolution 42 ms) for advanced functional evaluation. The z-flying focal spot technique implemented in the evaluated DSCT system allows 0.4 mm cylinders to be resolved at all heart rates. First clinical experience shows a considerably increased robustness for the imaging of patients with high heart rates. As a potential application of the dual-energy acquisition mode, the automatic separation of bones and iodine-filled vessels is demonstrated.


Assuntos
Angiografia Coronária/instrumentação , Estenose Coronária/diagnóstico , Ecocardiografia Quadridimensional/instrumentação , Eletrocardiografia/instrumentação , Aumento da Imagem/instrumentação , Processamento de Imagem Assistida por Computador/instrumentação , Avaliação da Tecnologia Biomédica , Tomografia Computadorizada Espiral/instrumentação , Diástole/fisiologia , Desenho de Equipamento , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Sensibilidade e Especificidade , Sístole/fisiologia
7.
J Thorac Cardiovasc Surg ; 129(3): 607-14, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15746745

RESUMO

OBJECTIVES: We sought to evaluate graft patency, flow, and flow reserve in patients with minimally invasive direct coronary artery bypass surgery of internal thoracic artery grafts by a combined magnetic resonance protocol with a phase-contrast technique and magnetic resonance angiography. METHODS: At 1.5 T (Magnetom Sonata, Siemens), 30 symptomatic patients with 30 left internal thoracic artery grafts were examined 6 years after minimally invasive surgical intervention. Navigator-gated magnetic resonance angiography and contrast-enhanced FLASH-3D magnetic resonance angiography (0.2 mmol gadopentate-diethylene triamine pentetic acid [Gd-DTPA]/kg body weight) was used to assess bypass patency. Phase-contrast flow measurements with retrospective gating were performed in the internal thoracic artery grafts at rest and after stress induction with dipyridamole (0.57 mg/kg body weight). Graft patency was evaluated by means of multidetector computed tomography (Sensation 16, Siemens). RESULTS: Internal thoracic artery grafts were occluded in 5 of 30 patients. In 6 patients the anastomosis to the left anterior descending artery was highly stenotic (>70 % ) at multidetector computed tomography. In patients with regular grafts (multidetector computed tomography), a significant improvement of graft flow ( P < .001) and diastolic/systolic peak velocity ratio ( P < .001) after stress induction was detected. Magnetic resonance angiography combined with flow reserve measurements could differentiate between occluded-stenotic and regular minimally invasive direct coronary artery bypass grafts. CONCLUSIONS: Magnetic resonance imaging allows a combined assessment of bypass patency and flow with flow reserve in patients after the minimally invasive direct coronary artery bypass operation. The protocol of this study might be applicable for the evaluation of graft status in symptomatic patients after revascularization.


Assuntos
Ponte de Artéria Coronária/métodos , Oclusão de Enxerto Vascular/diagnóstico , Imageamento por Ressonância Magnética/métodos , Artéria Torácica Interna/transplante , Grau de Desobstrução Vascular , Idoso , Constrição Patológica , Humanos , Angiografia por Ressonância Magnética , Artéria Torácica Interna/patologia , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional , Sensibilidade e Especificidade
8.
Eur Radiol ; 15(5): 919-29, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15662491

RESUMO

Computed tomography pulmonary angiography (CTA) has increasingly become accepted as a widely available, safe, cost-effective, and accurate method for a quick and comprehensive diagnosis of acute pulmonary embolism (PE). Pulmonary catheter angiography is still considered the gold standard and final imaging method in many diagnostic algorithms. However, spiral CTA has become established as the first imaging test in clinical routine due to its high negative predictive value for clinically relevant PE. Despite the direct visualization of clot material, depiction of cardiac and pulmonary function in combination with the quantification of pulmonary obstruction helps to grade the severity of PE for further risk stratification and to monitor the effect of thrombolytic therapy. Because PE and deep venous thrombosis are two different aspects of the same disease, additional indirect CT venography may be a valuable addition to the initial diagnostic algorithm-if this was positive for PE-and demonstration of the extent and localization of deep venous thrombosis has an impact on clinical management. Additional and alternate diagnoses add to the usefulness of this method. Using advanced multislice spiral CT technology, some practitioners have advocated CTA as the sole imaging tool for routine clinical assessment in suspected acute PE. This will simplify standards of practice in the near future.


Assuntos
Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada Espiral , Doença Aguda , Algoritmos , Humanos , Reprodutibilidade dos Testes
9.
Technol Cancer Res Treat ; 2(3): 273-9, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12779357

RESUMO

The aim of this study was to compare different representation models of surface-rendered virtual bronchoscopy. 10 consecutive patients with inoperable primary lung tumors underwent thin-section spiral computed tomography. The structures of interest, the tracheobronchial system and anatomical and pathological thoracic structures were segmented using an interactive threshold interval volume-growing segmentation algorithm and visualized with the aid of a color-coded surface rendering method. For virtual bronchoscopy, the tracheobronchial system was visualized using a triangle-surface rendering model, a shaded-surface rendering model and a transparent shaded-surface rendering model. The triangle-surface rendering model allowed optimum detailed spatial representation of the dimensions of extraluminal anatomical and pathological mediastinal structures. As the lumen of the tracheobronchial system was less well defined, the rendering model was of limited use for depiction of the airway surface. The shaded-surface rendering model facilitated an optimum assessment of the airway surface, but the mediastinal structures could not be depicted. The transparent shaded-surface rendering model provides simultaneous adequate to optimum visualization and assessment of the intraluminal airway surface and the extraluminal mediastinal structures as well as a quantitative assessment of the spatial relationship between these structures. Fast data acquisition with a multi-slice detector spiral computed tomography scanner and the use of virtual bronchoscopy with the transparent shaded-surface rendering model obviate the need for time consuming detailed analysis and presentation of axial source images by providing improved the diagnostic imaging of endotracheal and endobronchial diseases and offering a useful alternative to fiberoptic bronchoscopy.


Assuntos
Broncoscopia/métodos , Interface Usuário-Computador , Carcinoma Broncogênico/diagnóstico , Carcinoma Broncogênico/diagnóstico por imagem , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Propriedades de Superfície , Tomografia Computadorizada por Raios X
10.
Herz ; 28(1): 7-19, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12616316

RESUMO

BACKGROUND: 4-slice CT scanners have shown limitations in clinical application for noninvasive coronary CT angiography (CTA). We evaluate advances in ECG-gated scanning of the heart and the coronary arteries with recently introduced 16-slice CT equipment (SOMATOM Sensation 16, Siemens, Forchheim, Germany). MATERIALS AND METHODS: The technical principles of ECG-gated cardiac scanning, scan parameters, and detector design of the new scanner are presented. ECG-gated scan and image reconstruction techniques and ECG-controlled dose modulation ("ECG pulsing") for a reduction of the patient dose are described, key parameters for image quality and simulation results presented, and phantom studies and initial patient experience discussed. The impact of reduced gantry rotation time (0.42 s) on temporal resolution and initial estimations of the patient dose are presented. RESULTS: Extensions of ECG-gated reconstruction algorithms used for 4-slice CT provide adequate image quality for up to 16 slices. For each detector collimation different slice widths are available for retrospective reconstruction with well-defined slice sensitivity profiles (SSPs). For coronary CTA the heart can be covered with 0.75 mm collimation within a 20-s breathhold. The best possible spatial resolution is 0.5 x 0.5 x 0.6 mm. For 0.42 s gantry rotation time, temporal resolution reaches its optimum (105 ms) at a heart rate of 81 bpm. Effective patient dose for coronary CTA is 4-5 mSv using ECG-pulsed acquisition. CONCLUSION: The clinical performance of coronary CTA by means of spatial resolution, temporal resolution and scan time is substantially improved with the evaluated 16-slice CT scanner. Also, display of smaller coronary segments and instent visualization are substantially improved.


Assuntos
Angiografia Coronária/instrumentação , Doença da Artéria Coronariana/diagnóstico por imagem , Anomalias dos Vasos Coronários/diagnóstico por imagem , Eletrocardiografia/instrumentação , Infarto do Miocárdio/diagnóstico por imagem , Tomografia Computadorizada Espiral/instrumentação , Algoritmos , Benchmarking , Simulação por Computador , Meios de Contraste/administração & dosagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Imageamento Tridimensional/instrumentação , Masculino , Computação Matemática , Modelos Cardiovasculares , Imagens de Fantasmas , Radiometria , Sensibilidade e Especificidade , Software
12.
Eur Radiol ; 13 Suppl 5: M102-15, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14989618

RESUMO

In the past 2 years mechanical multidetector-row CT (MDCT) systems with simultaneous acquisition of four slices and half-second scanner rotation have become widely available. Data acquisition with these scanners allows for considerably faster coverage of the heart volume compared with single-slice scanning. This increased scan speed can be used for retrospective gating together with 1-mm collimated slice widths and allows coverage of the entire cardiac volume in one breath hold. Initial results from studies in correlation with intracoronary ultrasound suggest that MDTC technology not only offers the possibility to visualize intracoronary stenoses non-invasively but also to differentiate plaque morphology. This is especially the case with the next generation of 16-row multidetector CT. An increased number of simultaneously acquired slices and sub-millimeter collimation for cardiac applications allows true isotropic scanning with high temporal resolution. Contrast-enhanced MDTC is a promising non-invasive technique for the detection, visualization, and characterization of stenotic artery disease. It could act as a gate keeper prior to cardiac catherization and finally replace conventional diagnostic modalities.


Assuntos
Calcinose/diagnóstico por imagem , Cardiomiopatias/diagnóstico por imagem , Doença das Coronárias/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Angiografia Coronária/métodos , Ponte de Artéria Coronária , Eletrocardiografia , Feminino , Oclusão de Enxerto Vascular/diagnóstico por imagem , Coração/diagnóstico por imagem , Frequência Cardíaca , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Doses de Radiação , Ultrassonografia
13.
Radiology ; 225(1): 113-9, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12354993

RESUMO

PURPOSE: To methodically evaluate the reproducibility and accuracy of coronary arterial calcification measurements by using spiral multi-detector row and electron-beam computed tomography (CT) with a beating heart phantom. MATERIALS AND METHODS: A phantom was built to mimic a beating heart with coronary arteries and calcified plaques. The simulated vessels moved in a pattern similar to that of a beating heart. The phantom operated at a variety of pulse rates (0-140 beats per minute). The phantom was repeatedly scanned in various positions by using various protocols with electron-beam and multi-detector row CT scanners to assess interexamination variability. Statistical analysis was performed to determine significant differences in interexamination variability for various acquisition protocols. RESULTS: Electrocardiographically (EKG) gated volume coverage with spiral multi-detector row CT (2.5-mm collimation) and overlapping image reconstruction (1-mm increment) was found to significantly improve the reliability of coronary arterial calcium quantification, especially for small plaques (P <.05). Mean interexamination variability was reduced from 35% +/- 6 (SD) (Agatston score, standard electron-beam CT) to 4% +/- 2 (P <.05) (volumetric score, spiral EKG-gated multi-detector row CT). CONCLUSION: By coupling retrospective gating with nearly isotropic volumetric imaging data, spiral multi-detector row CT provides better input data for quantification of coronary arterial calcium volume. Multi-detector row CT allows precise and repeated measurement of coronary arterial calcification, with low interexamination variability.


Assuntos
Calcinose/diagnóstico por imagem , Doença das Coronárias/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Eletrocardiografia , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Cintilografia , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...