Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Neurol ; 12: 637551, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33927680

RESUMO

Introduction: Penumbra SMART COIL® (SMART) System is a novel generation embolic coil with varying stiffness. The study purpose was to report real-world usage of the SMART System in patients with intracranial aneurysms (ICA) and non-aneurysm vascular lesions. Materials and Methods: The SMART Registry is a post-market, prospective, multicenter registry requiring ≥75% Penumbra Coils, including SMART, PC400, and/or POD coils. The primary efficacy endpoint was retreatment rate at 1-year and the primary safety endpoint was the procedural device-related serious adverse event rate. Results: Between June 2016 and August 2018, 995 patients (mean age 59.6 years, 72.1% female) were enrolled at 68 sites in the U.S. and Canada. Target lesions were intracranial aneurysms in 91.0% of patients; 63.5% were wide-neck and 31.8% were ruptured. Adjunctive devices were used in 55.2% of patients. Mean packing density was 32.3%. Procedural device-related serious adverse events occurred in 2.6% of patients. The rate of immediate post-procedure adequate occlusion was 97.1% in aneurysms and the rate of complete occlusion was 85.2% in non-aneurysms. At 1-year, the retreatment rate was 6.8%, Raymond Roy Occlusion Classification (RROC) I or II was 90.0% for aneurysms, and Modified Rankin Scale (mRS) 0-2 was achieved in 83.1% of all patients. Predictors of 1-year for RROC III or retreatment (incomplete occlusion) were rupture status (P < 0.0001), balloon-assisted coiling (P = 0.0354), aneurysm size (P = 0.0071), and RROC III immediate post-procedure (P = 0.0086) in a model that also included bifurcation aneurysm (P = 0.7788). Predictors of aneurysm retreatment at 1-year was rupture status (P < 0.0001). Conclusions: Lesions treated with SMART System coils achieved low long-term retreatment rates. Clinical Trial Registration: https://www.clinicaltrials.gov/, identifier NCT02729740.

2.
Front Neurol ; 11: 83, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32132966

RESUMO

Background and Objective: The first pass effect (FPE; achieving complete recanalization with a single thrombectomy device pass) has been shown to be associated with higher rates of good clinical outcomes in patients with acute ischemic stroke. Here, we investigate clinical and radiographic factors associated with FPE in a large U.S. post-marketing registry (TRACK, Trevo Stent-Retriever Acute Stroke). Methods: We analyzed the TRACK database (multicenter registry of 634 patients from 23 centers from March 2013 through August 2015), which 609 patients were included in the final analysis. FPE was defined as a single pass/use of device, TICI 2c/3 recanalization, and no use of rescue therapy. Analysis of individual patient data from TRACK were performed to analyze clinical and radiographic characteristics associated with FPE as well-compared clinical outcomes defined as modified Rankin Scale (mRS) score at 30 and 90 days from hospital discharge to the non-FPE group. Results: The rate of FPE in TRACK was 23% (140/609). There was no association between patient demographics and FPE, including age (p = 0.36), sex (p = 0.50), race (p = 0.50), location of occlusion (p = 0.26), baseline NIHSS (p = 0.62), or past medical history. There was no difference in the use of a balloon-guide catheter or general anesthesia (49 and 57% with FPE vs. 47 and 64%, p = 0.63 and p = 0.14, respectively). Clinical outcomes were significantly associated with FPE; 63 vs. 44% in non-FPE patients achieved mRS 0-2 at 90 days (p = 0.0004). Conclusion: Our study showed that achieving complete recanalization with a single thrombectomy pass using the Trevo device was highly beneficial. The most common clinical factors that are used to determine eligibility for endovascular therapy, such as NIHSS severity, location of occlusion or patient age were not predictive of the ability to achieve FPE.

3.
Front Neurol ; 10: 737, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31338061

RESUMO

Background and Purpose: To describe the final results of the TARGET Registry, a multicenter, real-world study of patients with intracranial aneurysms treated with new generation TARGET Coils. Methods: The TARGET Registry is a prospective, single-arm study with independent medical event monitoring and core-lab adjudication. Patients with de novo intracranial aneurysms were embolized with either TARGET-360° or helical coils in 12 US centers. The primary outcome was aneurysm packing density (PD), which was assessed immediately post-procedure. The secondary outcomes were immediate and long-term aneurysm occlusion rate using the Raymond Scale, and independent functional outcome using the modified Rankin Scale (mRS). A secondary analysis investigated the influence of the use of 100% 360-complex coils on clinical and angiographic outcomes. Results: 148 patients with 157 aneurysms met the inclusion and exclusion criteria. 58 (39.2%) patients with ruptured and 90 (61.8%) with unruptured aneurysms were treated using TARGET 360°, helical Coils, or both. Median age was 58.3 (IQR 48.1-67.4), 73% female, and 71.6% were Caucasian. Median follow-up time was 5.9 (IQR 4.0-6.9) months. The majority were treated with TARGET 360-coils (63.7%), followed by mixed and helical coils only. Peri-procedural morbidity and mortality was seen in 2.7% of patients. A good outcome at discharge (mRS 0-2) was seen in 89.9% of the full cohort, and in 84.5 and 93.3% in the ruptured and unruptured patients, respectively. The median packing density was 28.8% (IQR 20.3-41.1). Long-term complete and near complete occlusion rate was seen in 90.4% of aneurysms and complete obliteration was seen in 66.2% of the aneurysms. No significant difference in clinical and angiographic outcomes were noted between the pure 360-complex coiling vs. mixed 360-complex/Helical coiling strategies. In a multivariate analysis, predictors for long-term aneurysm occlusion were aneurysm location, immediate occlusion grade, and aneurysm size. The long-term independent functional outcome was achieved in 128/135 (94.8%) patients and all-cause mortality was seen in 3/148 (2%) patients. Conclusion: In the multicenter TARGET Registry, two-thirds of aneurysms achieved long-term complete occlusion and 91.0% achieved complete or near complete occlusion with excellent independent functional outcome. Clinical Trial Registration: www.ClinicalTrials.gov, identifier: NCT01748903.

4.
J Neurointerv Surg ; 11(9): 861-865, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30712011

RESUMO

INTRODUCTION: The Solitaire stent retriever registry showed improved reperfusion, faster procedure times, and better outcome in acute stroke patients with large vessel occlusion treated with a balloon guide catheter (BGC) and Solitaire stent retriever compared with a conventional guide catheter. The goal of this study was to evaluate whether use of a BGC with the Trevo stent retriever improves outcomes compared with a conventional guide catheter. METHODS: The TRACK registry recruited 23 sites to submit demographic, clinical, and site adjudicated angiographic and outcome data on consecutive patients treated with the Trevo stent retriever. BGC use was at the discretion of the physician. RESULTS: 536 anterior circulation patients (of whom 279 (52.1%) had BGC placement) were included in this analysis. Baseline characteristics were notable for younger patients in the BGC group (65.4±15.3 vs 68.1±13.6, P=0.03) and lower rate of hypertension (72% vs 79%, P=0.06). Mean time from symptom onset to groin puncture was longer in the BGC group (357 vs 319 min, P=0.06).Thrombolysis in Cerebral Infarction 2b/3 scores were higher in the BGC cohort (84% vs 75.5%, P=0.01). There was no difference in reperfusion time, first pass effect, number of passes, or rescue therapy. Good clinical outcome at 3 months was superior in patients with BGC (57% vs 40%; P=0.0004) with a lower mortality rate (13% vs 23%, P=0.008). Multivariate analysis demonstrated that BGC use was an independent predictor of good clinical outcome (OR 2; 95% CI 1.3 to 3.1, P=0.001). CONCLUSIONS: In acute stroke patients presenting with anterior circulation large vessel occlusion, use of a BGC with the Trevo stent retriever resulted in improved reperfusion, improved clinical outcome, and lower mortality.


Assuntos
Cateterismo/métodos , Reperfusão/métodos , Acidente Vascular Cerebral/cirurgia , Trombectomia/métodos , Idoso , Idoso de 80 Anos ou mais , Cateterismo/instrumentação , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Reperfusão/instrumentação , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Trombectomia/instrumentação , Resultado do Tratamento
5.
J Neurointerv Surg ; 10(6): 516-524, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28963367

RESUMO

BACKGROUND: Recent randomized clinical trials (RCTs) demonstrated the efficacy of mechanical thrombectomy using stent-retrievers in patients with acute ischemic stroke (AIS) with large vessel occlusions; however, it remains unclear if these results translate to a real-world setting. The TREVO Stent-Retriever Acute Stroke (TRACK) multicenter Registry aimed to evaluate the use of the Trevo device in everyday clinical practice. METHODS: Twenty-three centers enrolled consecutive AIS patients treated from March 2013 through August 2015 with the Trevo device. The primary outcome was defined as achieving a Thrombolysis in Cerebral Infarction (TICI) score of ≥2b. Secondary outcomes included 90-day modified Rankin Scale (mRS), mortality, and symptomatic intracranial hemorrhage (sICH). RESULTS: A total of 634patients were included. Mean age was 66.1±14.8 years and mean baseline NIH Stroke Scale (NIHSS) score was 17.4±6.7; 86.7% had an anterior circulation occlusion. Mean time from symptom onset to puncture and time to revascularization were 363.1±264.5 min and 78.8±49.6 min, respectively. 80.3% achieved TICI ≥2b. 90-day mRS ≤2 was achieved in 47.9%, compared with 51.4% when restricting the analysis to the anterior circulation and within 6 hours (similar to recent AHA/ASA guidelines), and 54.3% for those who achieved complete revascularization. The 90-day mortality rate was 19.8%. Independent predictors of clinical outcome included age, baseline NIHSS, use of balloon guide catheter, revascularization, and sICH. CONCLUSION: The TRACK Registry results demonstrate the generalizability of the recent thrombectomy RCTs in real-world clinical practice. No differences in clinical and angiographic outcomes were shown between patients treated within the AHA/ASA guidelines and those treated outside the recommendations.


Assuntos
Isquemia Encefálica/cirurgia , Transtornos Cerebrovasculares/cirurgia , Sistema de Registros , Stents , Acidente Vascular Cerebral/cirurgia , Trombectomia/métodos , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/diagnóstico por imagem , Transtornos Cerebrovasculares/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Trombectomia/instrumentação , Resultado do Tratamento
6.
J Neurointerv Surg ; 7(5): e19, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-24778141

RESUMO

A 65-year-old man with a left cavernous internal carotid artery cerebral aneurysm experienced a premature detachment of the first framing coil (10 mm × 40 cm Penumbra Complex Standard) during a coil embolization procedure. The coil herniated into the anterior cerebral artery and pericallosal artery. Multiple attempts to retrieve the coil using both a 2 and 4 mm Microsnare (Amplatz GooseNeck) failed. A Trevo ProVue retrievable stent was then used to retrieve the coil without any adverse events. This case report highlights a novel use of a stent for the removal of a foreign body from the cerebrovascular system.


Assuntos
Doenças das Artérias Carótidas/terapia , Remoção de Dispositivo/instrumentação , Embolização Terapêutica/efeitos adversos , Falha de Equipamento , Aneurisma Intracraniano/terapia , Stents , Idoso , Remoção de Dispositivo/métodos , Humanos , Masculino
7.
BMJ Case Rep ; 20142014 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-24759162

RESUMO

A 65-year-old man with a left cavernous internal carotid artery cerebral aneurysm experienced a premature detachment of the first framing coil (10 mm × 40 cm Penumbra Complex Standard) during a coil embolization procedure. The coil herniated into the anterior cerebral artery and pericallosal artery. Multiple attempts to retrieve the coil using both a 2 and 4 mm Microsnare (Amplatz GooseNeck) failed. A Trevo ProVue retrievable stent was then used to retrieve the coil without any adverse events. This case report highlights a novel use of a stent for the removal of a foreign body from the cerebrovascular system.


Assuntos
Artéria Carótida Interna , Embolização Terapêutica/instrumentação , Corpos Estranhos/terapia , Aneurisma Intracraniano/terapia , Stents , Idoso , Remoção de Dispositivo/métodos , Embolização Terapêutica/efeitos adversos , Falha de Equipamento , Corpos Estranhos/etiologia , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...