Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Int J Cardiol Cardiovasc Risk Prev ; 16: 200170, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36874037

RESUMO

Background: Increased afterload affects many of the flow dependent metrics assessed during transthoracic echocardiography (TTE) especially in the evaluation valvular disease. A single timepoint blood pressure (BP) may not accurately reflect the afterload present at the time of flow-dependent imaging and quantification. We assessed the magnitude of change in BP at discrete timepoints during routine TTE. Method: We conducted a prospective study where participants underwent automated BP measurement while undergoing a clinically indicated TTE. The first reading was obtained right after the patient lay supine and subsequent readings were taken at 10-min intervals during image acquisition. Result: We included 50 participants (66% were male, with a mean age of 64 years). After 10 min, 40 (80%) participants had a drop in systolic BP of >10 mmHg. Compared to the baseline, there was a significant drop in systolic BP (mean decrease 20.0 ± 12.8 mmHg; P < 0.05), and diastolic BP (mean decrease 15.7 ± 13.2 mmHg; P < 0.05) at 10 min. The systolic BP remained different from the baseline value throughout the duration of the study (average decrease from baseline to study end was 12.4 ± 16.0 mmHg, p < 0.05). Conclusion: BP recorded just prior to TTE does not accurately reflect the afterload present during most of the study. This finding has important implications for valvular heart disease imaging protocols that incorporate flow dependent metrics, where the presence or absence of hypertension may lead to under- or over-estimation of disease severity.

2.
BMJ Case Rep ; 14(11)2021 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-34848416

RESUMO

A 38-year-old man presented with several days of chest pain and shortness of breath 8 days after receiving the first dose of an mRNA-1273 vaccine. The patient was found to have new left ventricular ejection fraction of 10% in the setting of hypotension and cardiogenic shock requiring mechanical support with an axial flow catheter pump. The presentation was concerning for acute fulminant myocarditis secondary to an inflammatory response from the recent mRNA-1273 vaccine. The patient was treated with pulse dose steroids for 3 days, ultimately leading to haemodynamic recovery and removal of mechanical circulatory support. Endomyocardial biopsy was performed and showed focal lymphocytic interstitial infiltrate with myocyte damage consistent with lymphocytic myocarditis. The patient had improvement of cardiac function which was seen on serial imaging.


Assuntos
Miocardite , Adulto , Humanos , Masculino , Choque Cardiogênico/etiologia , Volume Sistólico , Resultado do Tratamento , Vacinação , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...