Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
AJNR Am J Neuroradiol ; 42(10): 1762-1768, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34503946

RESUMO

BACKGROUND AND PURPOSE: By means of artificial intelligence, 3D angiography is a novel postprocessing method for 3D imaging of cerebral vessels. Because 3D angiography does not require a mask run like the current standard 3D-DSA, it potentially offers a considerable reduction of the patient radiation dose. Our aim was an assessment of the diagnostic value of 3D angiography for visualization of cerebrovascular pathologies. MATERIALS AND METHODS: 3D-DSA data sets of cerebral aneurysms (n CA = 10), AVMs (n AVM = 10), and dural arteriovenous fistulas (dAVFs) (n dAVF = 10) were reconstructed using both conventional and prototype software. Corresponding reconstructions have been analyzed by 2 neuroradiologists in a consensus reading in terms of image quality, injection vessel diameters (vessel diameter [VD] 1/2), vessel geometry index (VGI = VD1/VD2), and specific qualitative/quantitative parameters of AVMs (eg, location, nidus size, feeder, associated aneurysms, drainage, Spetzler-Martin score), dAVFs (eg, fistulous point, main feeder, diameter of the main feeder, drainage), and cerebral aneurysms (location, neck, size). RESULTS: In total, 60 volumes have been successfully reconstructed with equivalent image quality. The specific qualitative/quantitative assessment of 3D angiography revealed nearly complete accordance with 3D-DSA in AVMs (eg, mean nidus size3D angiography/3D-DSA= 19.9 [SD, 10.9]/20.2 [SD, 11.2] mm; r = 0.9, P = .001), dAVFs (eg, mean diameter of the main feeder3D angiography/3D-DSA= 2.04 [SD, 0.65]/2.05 [SD, 0.63] mm; r = 0.9, P = .001), and cerebral aneurysms (eg, mean size3D angiography/3D-DSA= 5.17 [SD, 3.4]/5.12 [SD, 3.3] mm; r = 0.9, P = .001). Assessment of the geometry of the injection vessel in 3D angiography data sets did not differ significantly from that of 3D-DSA (vessel geometry indexAVM: r = 0.84, P = .003; vessel geometry indexdAVF: r = 0.82, P = .003; vessel geometry indexCA: r = 0.84, P <.001). CONCLUSIONS: In this study, the artificial intelligence-based 3D angiography was a reliable method for visualization of complex cerebrovascular pathologies and showed results comparable with those of 3D-DSA. Thus, 3D angiography is a promising postprocessing method that provides a significant reduction of the patient radiation dose.


Assuntos
Malformações Vasculares do Sistema Nervoso Central , Aneurisma Intracraniano , Malformações Arteriovenosas Intracranianas , Angiografia Digital , Inteligência Artificial , Angiografia Cerebral , Humanos , Imageamento Tridimensional , Aneurisma Intracraniano/diagnóstico por imagem , Angiografia por Ressonância Magnética
2.
Phys Med Biol ; 61(12): 4583-4598, 2016 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-27271804

RESUMO

The imaging technology magnetic particle imaging allows the detection of magnetic material, in particular superparamagnetic nanoparticles, by remagnetization of the material via magnetic fields. The application is aimed at medical imaging where the particles are applied as tracer directly into the blood stream. Medical safety considerations such as peripheral nerve stimulation limit the maximal amplitude of the magnetic fields and in turn the field of view size. To handle this constraint the concept of patches was introduced, which allows a shift of a field of view to different positions in order to enlarge the imaging area. If this is done statically an overlap of patches can be used to reduce truncation artifacts occurring at the adjacent edges. In this contribution, a differentiation of two different kinds of patch overlaps, i.e. a trajectory and a system matrix overlap, is made. Further, different concepts to combine the resulting redundant information are investigated with respect to the reduction of truncation artifacts. The methods are analyzed in detail in a simulation study and validated on experimental data.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...