Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
3.
J Intensive Care Med ; 33(2): 111-115, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27619691

RESUMO

PURPOSE: Screening of patients with sepsis is needed to increase recognition and allow for earlier interventions. There is no consensus on whether the addition of lactate to the critical result laboratory's call list should be a standard practice. MATERIALS AND METHODS: This was a retrospective cohort study that compared management and outcomes of patients with sepsis having lactate ≥4 mmol/L before (group 1) and after (group 2) the addition of a critical result threshold of lactate of ≥4 mmol/L to the critical result laboratory's call list and its effects on time to antibiotics and intravenous fluids (IVFs). RESULTS: One hundred twenty-one patients were included. Lactate was higher in group 1 (7.0 ± 4.3 vs 5.6 ± 2.0, P = 0.03). More patients in group 2 received hydrocortisone (1.9% vs 22.4%, P = .001). Hospital mortality, 30-day mortality, and 90-day mortality were significantly lower in group 2 (59.3% vs 32.8%, P = .003; 68.5% vs 37.3%, P ≤ .001; 68.5% vs 41.8%, P = .002). There were no significant differences in total volume of IVFs (2400.8 ± 1720.0 vs 2483.7 ± 2155.7, P = 0.83), time to start IVFs (184.0 ± 283.2 vs 115.6 ± 190.5, P = 0.27), or antibiotics (184.8 ± 187.1 vs 133.7 ± 137.4, P = 0.16). CONCLUSION: Addition of lactate to the critical result laboratory's call list did not lead to a statistically significant improvement in time to IVFs or antibiotics, although the average time to antibiotics and IVFs decreased by 51.1 and 68.4 minutes, respectively. Hospital mortality, 30-day mortality, and 90-day mortality were lower in group 2, which may be, in part, due to increased recognition of severe sepsis by critical result notification and earlier intervention.


Assuntos
Mortalidade Hospitalar , Ácido Láctico/sangue , Política Organizacional , Sepse/diagnóstico , Tempo para o Tratamento , APACHE , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Estudos de Coortes , Diagnóstico Precoce , Intervenção Médica Precoce , Medicina de Emergência , Serviço Hospitalar de Emergência , Feminino , Hidratação/métodos , Humanos , Laboratórios Hospitalares , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Mortalidade , Análise Multivariada , Estudos Retrospectivos , Sepse/sangue , Sepse/terapia , Telefone
4.
J Appl Lab Med ; 1(3): 325-328, 2016 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-33626850
5.
EJIFCC ; 26(3): 158-67, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27683491

RESUMO

The National Academy of Clinical Biochemistry (NACB) has developed consensus-based guidelines for the laboratory evaluation and monitoring of patients with specified disorders for two decades. In 1997, the NACB recognized the need to standardize the process of guideline development and promulgated its first Standard Operating Procedure (SOP) for this purpose. In 2010, the American Association of Clinical Chemistry (AACC) and NACB created the Evidence-Based Laboratory Medicine Committee (EBLMC). Among other roles, this group was given responsibility to provide oversight of clinical practice guideline development in accordance with SOP guidance and using currently accepted good practices. In 2011, the U.S. Institute of Medicine (IOM) published two reports of relevance: 'Clinical Practice Guidelines We Can Trust' and 'Finding What Works in Health Care - Standards for Systematic Reviews.' These reports were created as part of a response to a legislative mandate from the U.S. Congress requesting that steps be taken to implement recommendations from lOM's report on 'Knowing What Works in Health Care' (2008). The latest revision of the laboratory medicine practice guidelines (LMPG) SOP was in part driven by these reports. NACB continues to develop LMPGs at a rate of roughly one per year through standard processes detailed in its 2014 revision of the SOP. This article describes the NACB and EBLMC experience in developing LMPGs with a focus on the evolution and use of the latest SOP. AACC and NACB have established a solid track record in collaboratively working with many clinical societies and professional organizations on clinical practice guideline development. Presently, three LMPG's are in various stages of development and all with the collaboration of other clinical/professional groups. The practices and tools being used for current LMPGs in progress are also highlighted in the context of the challenges that presently exist for effective clinical practice guideline development in the U.S.

7.
Clin Biochem ; 45(13-14): 988-98, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22750145

RESUMO

OBJECTIVES: This is the first systematic review of the effectiveness of barcoding practices for reducing patient specimen and laboratory testing identification errors. DESIGN AND METHODS: The CDC-funded Laboratory Medicine Best Practices Initiative systematic review methods for quality improvement practices were used. RESULTS: A total of 17 observational studies reporting on barcoding systems are included in the body of evidence; 10 for patient specimens and 7 for point-of-care testing. All 17 studies favored barcoding, with meta-analysis mean odds ratios for barcoding systems of 4.39 (95% CI: 3.05-6.32) and for point-of-care testing of 5.93 (95% CI: 5.28-6.67). CONCLUSIONS: Barcoding is effective for reducing patient specimen and laboratory testing identification errors in diverse hospital settings and is recommended as an evidence-based "best practice." The overall strength of evidence rating is high and the effect size rating is substantial. Unpublished studies made an important contribution comprising almost half of the body of evidence.


Assuntos
Técnicas de Laboratório Clínico/normas , Erros de Diagnóstico/prevenção & controle , Prática Clínica Baseada em Evidências/normas , Avaliação de Programas e Projetos de Saúde/métodos , Centers for Disease Control and Prevention, U.S. , Técnicas de Laboratório Clínico/métodos , Bases de Dados Factuais , Processamento Eletrônico de Dados/métodos , Prática Clínica Baseada em Evidências/métodos , Humanos , Razão de Chances , Guias de Prática Clínica como Assunto/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Estados Unidos
8.
Clin Chem ; 57(8): 1108-17, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21677092

RESUMO

Results between different clinical laboratory measurement procedures (CLMP) should be equivalent, within clinically meaningful limits, to enable optimal use of clinical guidelines for disease diagnosis and patient management. When laboratory test results are neither standardized nor harmonized, a different numeric result may be obtained for the same clinical sample. Unfortunately, some guidelines are based on test results from a specific laboratory measurement procedure without consideration of the possibility or likelihood of differences between various procedures. When this happens, aggregation of data from different clinical research investigations and development of appropriate clinical practice guidelines will be flawed. A lack of recognition that results are neither standardized nor harmonized may lead to erroneous clinical, financial, regulatory, or technical decisions. Standardization of CLMPs has been accomplished for several measurands for which primary (pure substance) reference materials exist and/or reference measurement procedures (RMPs) have been developed. However, the harmonization of clinical laboratory procedures for measurands that do not have RMPs has been problematic owing to inadequate definition of the measurand, inadequate analytical specificity for the measurand, inadequate attention to the commutability of reference materials, and lack of a systematic approach for harmonization. To address these problems, an infrastructure must be developed to enable a systematic approach for identification and prioritization of measurands to be harmonized on the basis of clinical importance and technical feasibility, and for management of the technical implementation of a harmonization process for a specific measurand.


Assuntos
Técnicas de Laboratório Clínico/normas , Garantia da Qualidade dos Cuidados de Saúde , Biomarcadores/análise , Humanos , Cooperação Internacional , Guias de Prática Clínica como Assunto , Padrões de Referência , Sensibilidade e Especificidade
9.
Am J Clin Pathol ; 129(4): 540-7, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18343780

RESUMO

We studied the magnitude, significance, and origin of an analytic bias that emerged between our point-of-care (POC) and our central laboratory (CL) methods for the measurement of hemoglobin A1c (HbA1c) and evaluated the analytic accuracy of 7 commonly used HbA1c methods relative to the National Glycohemoglobin Standardization Program (NGSP) reference method. The POC and CL methods were compared by split-sample analysis of clinical specimens and time series analyses of the HbA1c results reported for a 33-month period. The relative accuracies of 7 HbA1c methods were evaluated using College of American Pathologists proficiency survey results. Long-term drifts in the CL- and POC-analyzed test results caused the median intermethod bias [(POC result)-(CL result)] to increase from -0.4% to -0.9% HbA1c. Systematic biases, drifts in analytic performance over time, and intermethod variability were frequently observed among the 7 NGSP-certified HbA1c methods. Intermethod variability is a potential source of inaccuracy whenever HbA1c results are interpreted relative to universal, fixed, clinical decision thresholds.


Assuntos
Análise Química do Sangue/normas , Hemoglobinas Glicadas/análise , Laboratórios/normas , Controle de Qualidade , Viés , Análise Química do Sangue/estatística & dados numéricos , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
10.
Clin Chem ; 52(9): 1685-92, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16858078

RESUMO

BACKGROUND: Cardiac tropoin I (cTnI) measurements show an approximately 20- to 40-fold difference between assays, and better standardization and harmonization are needed. Toward this goal, the AACC cTnI Standardization Committee collaborated with the National Institute of Standards and Technology (NIST) in an earlier study to select 2 candidate reference materials (cRMs). METHODS: Two troponin cRMs, a troponin C-troponin I-troponin T (CIT) complex from human heart tissue and a CIT complex from recombinant technology, were supplied to NIST for assessment of composition and purity, and cTnI value assignment. These cRMs and 6 cTnI-positive human serum pools were shipped to manufacturers of 15 cTnI assays. Commutability of the materials was examined by determining the numerical relationship for the cRM preparations between each manufacturer-specified field method and each of the other 14 field methods. These relationships were then compared with the corresponding numerical relationships for the human serum pools. Harmonization of methods was accomplished by determining regression parameters relative to the analytical system yielding values closest to the median for each serum pool. These regression parameters were used to recalculate pool values to harmonize the assays. Interassay CVs before and after harmonization were determined. RESULTS: Characterization of the CIT and CI cRMs showed that these materials were of specified composition. The proportion of cTnI methods that demonstrated commutability for the CIT cRM was 45%; for the CI cRM, 39% of methods demonstrated commutability. Interassay cTnI variability for the field methods ranged from 82% to 97%, median 88%. After harmonization, variability of the serum pools for the cTnI methods was decreased to between 9.0% and 23%, median 15.5%. CONCLUSIONS: The proportion of methods demonstrating commutability was too low for use as a common calibrator for the cTnI field methods. However a simple strategy using serum pools can improve harmonization of field cTnI methods by more than 5-fold. The CIT cRM was selected by the AACC cTnI standardization committee, and a new lot has been classified as the cTnI certified reference material Standard Reference Material 2921 by NIST.


Assuntos
Troponina I/normas , Calibragem , Testes de Química Clínica/normas , Humanos , Imunoensaio , Miocárdio/química , Proteínas Recombinantes/normas , Padrões de Referência , Troponina C/normas , Troponina I/sangue , Troponina I/isolamento & purificação
11.
Arch Pathol Lab Med ; 129(4): 474-80, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15794669

RESUMO

CONTEXT: The prognostic value of mild elevation of cardiac-specific troponin I (cTnI) levels is poorly defined, which can make interpretation of such an elevation difficult. OBJECTIVE: To study the prognostic value of transient mild elevation of cTnI levels in the hospitalized patient population. DESIGN: We performed a case-control study that compared the outcome of patients hospitalized for any cause with at least 2 subsequent transient cTnI measurements of 0.1 ng/mL or higher and less than 1.5 ng/mL with matched controls with cTnI levels less than 0.1 ng/mL. A cohort of 118 patients (mean +/- SD age, 67.4 +/- 14.0 years; 35.6% men) was followed up for an average +/- SD of 11.9 +/- 7.9 months. Seventy-one cases were matched with 37 controls in terms of demographics, coronary artery disease risk factors, and reason for admission. End points were all-cause mortality and major cardiovascular end points, including cardiovascular mortality, myocardial infarction, and revascularization. RESULTS: The total event rate was significantly increased in the case group compared with the control group at 12, 6, and 3 months (62.0% vs 24.3%, 59.2% vs 16.2%, and 47.9% vs 5.4%, respectively; P < .001). At 12, 6, and 3 months, the cases had a significant increase in all-cause mortality (43.7% vs 16.2%, 40.8% vs 8.1%, and 33.8% vs 0.0%, respectively; P = .005) and major cardiovascular end points (26.8% vs 8.1%, 26.8% vs 8.1%, and 21.1% vs 5.4%, respectively; P = .02) compared with controls. CONCLUSION: Transient mild elevation of cTnI levels in hospitalized patients is associated with an increase in all-cause mortality and major cardiovascular complications. Such elevations of cTnI levels can be considered a marker for both all-cause and cardiovascular morbidity and mortality.


Assuntos
Doenças Cardiovasculares/sangue , Doenças Cardiovasculares/epidemiologia , Mortalidade , Troponina I/sangue , Idoso , Doenças Cardiovasculares/mortalidade , Estudos de Casos e Controles , Feminino , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Morbidade , Prognóstico
12.
Toxicol Rev ; 24(4): 217-27, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16499404

RESUMO

In the US, two antivenins are marketed for the treatment of snake envenomation. The horse-derived serum-globulin-based Antivenin (Crotalidae) Polyvalent (ACP) has been available since 1954. There are few data on the efficacy and incidence of adverse events that occur following the administration of ACP. Most of the data are retrospective, anecdotal, or case reports. In 2000, ovine-derived serum-globulin-based ACP (Crofab) became available. Crofab is said to cause fewer reactions than ACP, but there are few comparative data to substantiate this claim. Although both antivenins ameliorate the systemic symptoms following snake envenomation, the efficacy of either antivenin in decreasing oedema and swelling is unknown for a number of reasons. Clinical trials are small and have not included control arms. The degree of oedema, as well as the efficacy of the antivenin in decreasing oedema, may depend on the genera of the snake (usually unknown) that envenomated the patient. This article compares available data on clinical aspects of the two antivenins. More prospective data are needed to determine the comparative efficacy of the two antivenins, or the efficacy of Crofab in preventing tissue oedema. There are still unanswered questions regarding the optimal dosing regimen of Crofab.


Assuntos
Antivenenos , Fragmentos de Imunoglobulinas , Mordeduras de Serpentes/terapia , Viperidae , Animais , Antivenenos/administração & dosagem , Antivenenos/efeitos adversos , Antivenenos/uso terapêutico , Humanos , Fragmentos Fab das Imunoglobulinas , Fragmentos de Imunoglobulinas/administração & dosagem , Fragmentos de Imunoglobulinas/efeitos adversos , Fragmentos de Imunoglobulinas/uso terapêutico , Mordeduras de Serpentes/sangue , Mordeduras de Serpentes/imunologia , Estados Unidos
13.
J Zoo Wildl Med ; 35(1): 34-9, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15193071

RESUMO

Serum lipid levels were measured in healthy captive wild canids and ursids, and the values were compared with previously published data. Serum lipid levels were evaluated in blood samples collected from eight African wild dogs (Lycaon pictus), three arctic foxes (Alopex lagopus), nine gray wolves (Canis lupus), four maned wolves (Chrysocyon brachyurus), two Mexican wolves (Canis lupus baleiyi), nine red wolves (Canis rufus), two brown bears (Ursus arctos), six polar bears (Ursus maritimus), six spectacled bears (Tremarctos ornatus), and five sun bears (Ursus malayanus). Samples were analyzed for total cholesterol, triacylglycerides, high-density lipoprotein-cholesterol, and low-density lipoprotein-cholesterol. Although the results showed a great variation among species, circulating lipids appeared especially high, sometimes extremely so, in the spectacled bears, polar bears, sun bears, and maned wolves compared with all other species sampled. The study provides a substantial basis for comparing lipid levels in presumed healthy animals and indicates a need for controlled study of the effects of diet on circulating lipid levels.


Assuntos
Carnívoros/sangue , Cães/sangue , Raposas/sangue , Lipídeos/sangue , Ursidae/sangue , Lobos/sangue , Animais , Animais de Zoológico , Colesterol/sangue , HDL-Colesterol/sangue , LDL-Colesterol/sangue , Feminino , Masculino , Valores de Referência , Especificidade da Espécie , Triglicerídeos/sangue
14.
J Nutr ; 133(1): 160-6, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12514284

RESUMO

Serum concentrations of several nutrients were measured in 12 captive wild felid species including caracal (Felis caracal), cheetah (Acinonyx jubatus), cougar (Felis concolor), fishing cat (Felis viverrinus), leopard (Panthera pardus), lion (Panthera leo), ocelot (Felis pardalis), pallas cat (Felis manul), sand cat (Felis margarita), serval (Felis serval), snow leopard (Panthera uncia) and tiger (Panthera tigris). Diet information was collected for these animals from each participating zoo (Brookfield Zoo, Fort Worth Zoo, Lincoln Park Zoological Gardens and North Carolina Zoological Park). The nutritional composition of the diets at each institution met the probable dietary requirements for each species except for the pallas cat. Blood samples were collected from each animal (n = 69) and analyzed for lipids (total cholesterol, triacylglycerides, HDL cholesterol and LDL cholesterol), vitamin D metabolites [25-hydroxycholecalciferol (25(OH)D) and 1,25-dihydroxycholecalciferol (1,25(OH)(2)D)], vitamin A (retinol, retinyl stearate and retinyl palmitate), vitamin E (alpha- and gamma-tocopherol) and selected carotenoids. Species differences were found for all except triacylglycerides and 1,25(OH)(2)D. Genus differences were found for retinol, retinyl palmitate, retinyl stearate, gamma-tocopherol and beta-carotene. Circulating nutrient concentrations for many of the species in this study have not been reported previously and most have not been compared with the animals' dietary intakes. The large number of animals analyzed provides a substantial base for comparing the serum nutrient concentrations of healthy animals, for both wild and captive exotic species.


Assuntos
Fenômenos Fisiológicos da Nutrição Animal , Animais de Zoológico/sangue , Carotenoides/sangue , Lipídeos/sangue , Tocoferóis/sangue , Vitamina A/sangue , Vitamina D/sangue , Animais , Especificidade da Espécie , Vitamina D/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...