Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ann Biomed Eng ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38748343

RESUMO

Low back pain (LBP) affects 50-80% of adults at some point in their lifetime, yet the etiology of injury is not well understood. Those exposed to repeated flexion-compression are at a higher risk for LBP, such as helicopter pilots and motor vehicle operators. Animal injury models offer insight into in vivo injury mechanisms, but interspecies scaling is needed to relate animal results to human. Human (n = 16) and porcine (n = 20) lumbar functional spinal units (FSUs) were loaded in repeated flexion-compression (1 Hz) to determine endplate fracture risk over long loading exposures. Flexion oscillated from 0 to 6° and peak applied compressive stress ranged from 0.65 to 2.38 MPa for human and 0.64 to 4.68 MPa for porcine specimens. Five human and twelve porcine injuries were observed. The confidence intervals for human and porcine 50% injury risk curves in terms of stress and cycles overlapped, indicating similar failure behavior for this loading configuration. However, porcine specimens were more tolerant to the applied loading compared to human, demonstrated by a longer time-to-failure for the same applied stress. Optimization revealed that time-to-failure in human specimens was approximately 25% that of porcine specimens at a given applied stress within 0.65-2.38 MPa. This study determined human and porcine lumbar endplate fracture risks in long-duration repeated flexion-compression that can be directly used for future equipment and vehicle design, injury prediction models, and safety standards. The interspecies scale factor produced in this study can be used for previous and future porcine lumbar injury studies to scale results to relevant human injury.

2.
J Biomech ; 49(9): 1845-1853, 2016 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-27155744

RESUMO

Wearable sensors are becoming increasingly popular for measuring head motions and detecting head impacts. Many sensors are worn on the skin or in headgear and can suffer from motion artifacts introduced by the compliance of soft tissue or decoupling of headgear from the skull. The instrumented mouthguard is designed to couple directly to the upper dentition, which is made of hard enamel and anchored in a bony socket by stiff ligaments. This gives the mouthguard superior coupling to the skull compared with other systems. However, multiple validation studies have yielded conflicting results with respect to the mouthguard׳s head kinematics measurement accuracy. Here, we demonstrate that imposing different constraints on the mandible (lower jaw) can alter mouthguard kinematic accuracy in dummy headform testing. In addition, post mortem human surrogate tests utilizing the worst-case unconstrained mandible condition yield 40% and 80% normalized root mean square error in angular velocity and angular acceleration respectively. These errors can be modeled using a simple spring-mass system in which the soft mouthguard material near the sensors acts as a spring and the mandible as a mass. However, the mouthguard can be designed to mitigate these disturbances by isolating sensors from mandible loads, improving accuracy to below 15% normalized root mean square error in all kinematic measures. Thus, while current mouthguards would suffer from measurement errors in the worst-case unconstrained mandible condition, future mouthguards should be designed to account for these disturbances and future validation testing should include unconstrained mandibles to ensure proper accuracy.


Assuntos
Cabeça/fisiologia , Mandíbula/fisiologia , Protetores Bucais , Aceleração , Fenômenos Biomecânicos , Humanos , Masculino
3.
Spine (Phila Pa 1976) ; 38(1): E1-12, 2013 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-23104191

RESUMO

STUDY DESIGN: Biomechanical tensile testing of perinatal, neonatal, and pediatric cadaveric cervical spines to failure. OBJECTIVE: To assess the tensile failure properties of the cervical spine from birth to adulthood. SUMMARY OF BACKGROUND DATA: Pediatric cervical spine biomechanical studies have been few due to the limited availability of pediatric cadavers. Therefore, scaled data based on human adult and juvenile animal studies have been used to augment the limited pediatric cadaver data. Despite these efforts, substantial uncertainty remains in our understanding of pediatric cervical spine biomechanics. METHODS: A total of 24 cadaveric osteoligamentous head-neck complexes, 20 weeks gestation to 18 years, were sectioned into segments (occiput-C2 [O-C2], C4-C5, and C6-C7) and tested in tension to determine axial stiffness, displacement at failure, and load-to-failure. RESULTS: Tensile stiffness-to-failure (N/mm) increased by age (O-C2: 23-fold, neonate: 22 ± 7, 18 yr: 504; C4-C5: 7-fold, neonate: 71 ± 14, 18 yr: 509; C6-C7: 7-fold, neonate: 64 ± 17, 18 yr: 456). Load-to-failure (N) increased by age (O-C2: 13-fold, neonate: 228 ± 40, 18 yr: 2888; C4-C5: 9-fold, neonate: 207 ± 63, 18 yr: 1831; C6-C7: 10-fold, neonate: 174 ± 41, 18 yr: 1720). Normalized displacement at failure (mm/mm) decreased by age (O-C2: 6-fold, neonate: 0.34 ± 0.076, 18 yr: 0.059; C4-C5: 3-fold, neonate: 0.092 ± 0.015, 18 yr: 0.035; C6-C7: 2-fold, neonate: 0.088 ± 0.019, 18 yr: 0.037). CONCLUSION: Cervical spine tensile stiffness-to-failure and load-to-failure increased nonlinearly, whereas normalized displacement at failure decreased nonlinearly, from birth to adulthood. Pronounced ligamentous laxity observed at younger ages in the O-C2 segment quantitatively supports the prevalence of spinal cord injury without radiographic abnormality in the pediatric population. This study provides important and previously unavailable data for validating pediatric cervical spine models, for evaluating current scaling techniques and animal surrogate models, and for the development of more biofidelic pediatric crash test dummies.


Assuntos
Fenômenos Biomecânicos/fisiologia , Vértebras Cervicais/fisiologia , Resistência à Tração/fisiologia , Adolescente , Fatores Etários , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Feto/fisiologia , Humanos , Lactente , Recém-Nascido , Masculino , Gravidez , Amplitude de Movimento Articular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA