Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Arq. bras. oftalmol ; Arq. bras. oftalmol;83(6): 511-516, Nov.-Dec. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1153082

RESUMO

ABSTRACT Purpose: The effects of sex steroid hormones on tearparameters are known. Theaim of this studywas to examine the effects on tear parameters during exposure to high-dose sex steroids in a short period of time. Methods: Forty patients who were admitted to the infertility clinic of our hospital and planned to undergo ovulation induction with exogenous gonadotropins were included in our study. Prior tothe initiation of ovulation induction, the basal levels of estradiol were measured on day 3 of the menstrual cycle and ophthalmologic examinations were performed by the ophthalmology department of our hospital. The estradiol levels were-measured on the day ofovulation induction usinghuman chorionic gonadotropin and compared with basal estra­diol; eye examinations were also repeated. Result: Forty women with reproductive period and average age of 33.3 ± 4.2 years were included in this study. Basal levels of estradiol were significantly (p<0.001) higher after ovulation induction than before induction. The scores in the break-up timeand after induction were 6.2 ± 2.8 sn and 8.4 ± 1.4 sn, respectively. The values of Schirmer's test were 14.3 ± 7.1 mm and 20.6 ± 6.2 mm before and after induction, respectively. Both values were significantly higher after ovulation induction (p<0.001; p=0.001, respectively). Conclusion: We observed impro­vemet in tear function tests following the use of estradiol even for a limited time.The use of estradiol during menopause may improve dry eye symptoms in patients.


RESUMO Objetivo: Os efeitos dos hormônios esteróides se­xuais nos parâmetros lacrimais são conhecidos. O objetivo deste estudo foi examinar como os efeitos nos parâmetros lacrimais durante a exposição a altas doses de esteróides sexuais em um curto período de tempo. Métodos: Quarenta pacientes que foram admitidas na clínica de infertilidade do nosso hospital e planejavam a indução de ovulação por gonadotropinas exógenas. Antes do início da indução da ovulação, os níveis basais de estradiol foram medidos no terceiro dia do ciclo menstrual e os exames oftalmológicos foram efetuados pelo Departamento de Oftalmologia do nosso hospital. Os níveis de estradiol foram medidos no dia da indução da ovulação usando gonadotrofina coriónica humana e comparados aos estradiol basal; exames oftalmológicos também foram repetidos. Resultado: Quarenta mulheres com período reprodutivo e idade média de 33,3 ± 4,2 anos foram incluídas neste estudo. Os níveis basais de estradiol foram significativamente maiores (p<0,001) após a indução da ovulação do que antes desta. Os resultados dos testes de ruptura do filme lacrimal e após a indução foi de 6,2 ± 2,8 s e 8,4 ± 1,4 s respectivamente. Os valores do teste de Schirmer foram 14,3 ± 7,1 mm e 20,6 ± 6,2 mm, respectivamente antes e depois da indução. Ambos os valores foram significativamente maiores após a indução da ovulação (p<0,001; p=0,001 respectivamente). Conclusão: Observamos uma melhora nos testes de função lacrimal após o uso de estradiol, mesmo por tempo limitado. O uso de estradiol durante a menopausa poderá melhorar os sintomas do olho seco em pacientes.


Assuntos
Humanos , Feminino , Adulto , Síndromes do Olho Seco , Tomografia de Coerência Óptica , Estradiol , Indução da Ovulação , Lágrimas
2.
Arq Bras Oftalmol ; 83(6): 511-516, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33470279

RESUMO

PURPOSE: The effects of sex steroid hormones on tearparameters are known. Theaim of this studywas to examine the effects on tear parameters during exposure to high-dose sex steroids in a short period of time. METHODS: Forty patients who were admitted to the infertility clinic of our hospital and planned to undergo ovulation induction with exogenous gonadotropins were included in our study. Prior tothe initiation of ovulation induction, the basal levels of estradiol were measured on day 3 of the menstrual cycle and ophthalmologic examinations were performed by the ophthalmology department of our hospital. The estradiol levels were-measured on the day ofovulation induction usinghuman chorionic gonadotropin and compared with basal estra-diol; eye examinations were also repeated. RESULT: Forty women with reproductive period and average age of 33.3 ± 4.2 years were included in this study. Basal levels of estradiol were significantly (p<0.001) higher after ovulation induction than before induction. The scores in the break-up timeand after induction were 6.2 ± 2.8 sn and 8.4 ± 1.4 sn, respectively. The values of Schirmer's test were 14.3 ± 7.1 mm and 20.6 ± 6.2 mm before and after induction, respectively. Both values were significantly higher after ovulation induction (p<0.001; p=0.001, respectively). CONCLUSION: We observed impro-vemet in tear function tests following the use of estradiol even for a limited time.The use of estradiol during menopause may improve dry eye symptoms in patients.


Assuntos
Síndromes do Olho Seco , Tomografia de Coerência Óptica , Adulto , Estradiol , Feminino , Humanos , Indução da Ovulação , Lágrimas
3.
Arq Bras Oftalmol ; 79(4): 229-32, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27626146

RESUMO

PURPOSE: To assess the effect of hemodialysis on retinal and choroidal thicknesses using spectral-domain optical coherence tomography (SD-OCT). METHODS: In this prospective interventional study, 25 hemodialysis patients (17 male, 8 female) were enrolled. All participants underwent high-speed, high-resolution SD-OCT (λ=840 mm; 26.000 A-scans/s; 5 µm resolution) before and after hemodialysis. Choroidal thickness was measured perpendicularly from the outer edge of the retinal pigment epithelium to the choroid-sclera boundary at the fovea and at five additional points: 500 µm and 1000 µm nasal to the fovea and 500 µm, 1000 µm, and 1500 µm temporal to the fovea. Two masked physicians performed the measurements. Choroidal and retinal thicknesses before and after hemodialysis were compared. RESULTS: The median choroidal thicknesses before and after hemodialysis were 182 µm (range, 103-374 µm) and 161 µm (range, 90-353 µm), respectively (P<0.001). The median retinal thicknesses were 246 µm (range, 179-296 µm) before and 248 µm (range, 141-299 µm) after hemodialysis (P>0.05). Systolic arterial pressure, diastolic arterial pressure, mean arterial pressure, heart rate, and ocular perfusion pressure significantly decreased after hemodialysis (P<0.001). Intraocular pressure did not vary significantly (P=0.540). CONCLUSION: Hemodialysis seems to cause a significant decrease in choroidal thickness, whereas it has no effect on retinal thickness. This significant decrease in choroidal thickness might be due to the extensive fluid absorption in hemodialysis, which could result in decreased ocular blood flow.


Assuntos
Corioide/anatomia & histologia , Corioide/diagnóstico por imagem , Diálise Renal/efeitos adversos , Retina/anatomia & histologia , Retina/diagnóstico por imagem , Adulto , Corioide/fisiopatologia , Olho/irrigação sanguínea , Feminino , Hemodinâmica , Humanos , Pressão Intraocular , Falência Renal Crônica/fisiopatologia , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Tamanho do Órgão , Estudos Prospectivos , Valores de Referência , Retina/fisiopatologia , Estatísticas não Paramétricas , Fatores de Tempo , Tomografia de Coerência Óptica/métodos , Adulto Jovem
4.
Arq. bras. oftalmol ; Arq. bras. oftalmol;79(4): 229-232, July-Aug. 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-794575

RESUMO

ABSTRACT Purpose: To assess the effect of hemodialysis on retinal and choroidal thicknesses using spectral-domain optical coherence tomography (SD-OCT). Methods: In this prospective interventional study, 25 hemodialysis patients (17 male, 8 female) were enrolled. All participants underwent high-speed, high-resolution SD-OCT (λ=840 mm; 26.000 A-scans/s; 5 µm resolution) before and after hemodialysis. Choroidal thickness was measured perpendicularly from the outer edge of the retinal pigment epithelium to the choroid-sclera boundary at the fovea and at five additional points: 500 µm and 1000 µm nasal to the fovea and 500 µm, 1000 µm, and 1500 µm temporal to the fovea. Two masked physicians performed the measurements. Choroidal and retinal thicknesses before and after hemodialysis were compared. Results: The median choroidal thicknesses before and after hemodialysis were 182 µm (range, 103-374 µm) and 161 µm (range, 90-353 µm), respectively (P<0.001). The median retinal thicknesses were 246 µm (range, 179-296 µm) before and 248 µm (range, 141-299 µm) after hemodialysis (P>0.05). Systolic arterial pressure, diastolic arterial pressure, mean arterial pressure, heart rate, and ocular perfusion pressure significantly decreased after hemodialysis (P<0.001). Intraocular pressure did not vary significantly (P=0.540). Conclusion: Hemodialysis seems to cause a significant decrease in choroidal thickness, whereas it has no effect on retinal thickness. This significant decrease in choroidal thickness might be due to the extensive fluid absorption in hemodialysis, which could result in decreased ocular blood flow.


RESUMO Objetivo: Avaliar o efeito da hemodiálise (HD) na espessura da retina (RT) e na espessura da coroide (CT) usando tomografia de coerência óptica de domínio espectral (SD-OCT). Método: Neste estudo prospectivo intervencionista foram incluídos 25 pacientes em HD (17 homens e 8 mulheres). Todos os participantes foram submetidos a SD-OCT com dispositivo de alta resolução (λ=840 mm; 26.000 A-scans/seg e resolução de 5 µm), antes e após HD. A CT foi medida perpendicularmente a partir da borda externa do epitélio pigmentar da retina até o limite coroide-esclera na fóvea e em mais de 5 pontos localizados 500 µm nasal à fóvea, 1.000 µm nasal à fóvea; 500 µm temporal à fóvea, 1.000 µm temporal à fóvea, e 1.500 µm temporal à fóvea. Dois médicos realizaram as medidas sem o conhecimento do diagnóstico. Os dados da CT e RT, antes e após a HD foram comparados. Resultados: As CTs medianas antes e após a HD foram 182 µm (variação de 103-374 µm) e 161 µm (variação de 90-353 µm), respectivamente (p<0,001). A RT foi 246 µm (variação de 179-296 µm) antes e 248 µm (variação de 141-299 µm) após a HD (p>0,05). A pressão arterial sistólica, pressão arterial diastólica, as médias de pressão arterial média, frequência cardíaca e pressão de perfusão ocular diminuíram significativamente após HD (p<0,001). A pressão intraocular não alterou significativamente (p=0,540). Conclusão: A HD parece causar uma redução significativa da CT, e não ter efeito sobre a RT. Esta redução significativa da CT pode ser devida à grande absorção de fluido durante a HD, o que pode resultar numa diminuição do fluxo sanguíneo ocular.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Retina/anatomia & histologia , Retina/diagnóstico por imagem , Corioide/anatomia & histologia , Corioide/diagnóstico por imagem , Diálise Renal/efeitos adversos , Tamanho do Órgão , Valores de Referência , Retina/fisiopatologia , Fatores de Tempo , Variações Dependentes do Observador , Estudos Prospectivos , Corioide/fisiopatologia , Estatísticas não Paramétricas , Tomografia de Coerência Óptica/métodos , Olho/irrigação sanguínea , Hemodinâmica , Pressão Intraocular , Falência Renal Crônica/fisiopatologia , Falência Renal Crônica/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA