Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biosens Bioelectron ; 25(5): 1008-13, 2010 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-19822413

RESUMO

We demonstrate a one-step wash-free bioassay measurement system capable of tracking biochemical binding events. Our approach combines the high resolution of frequency- and high speed of time-domain measurements in a single device in combination with a fast one-step bioassay. The one-step nature of our magnetic nanoparticle (MNP) based assay reduces the time between sample extraction and quantitative results while mitigating the risks of contamination related to washing steps. Our method also enables tracking of binding events, providing the possibility of, for example, investigation of how chemical/biological environments affect the rate of a binding process or study of the action of certain drugs. We detect specific biological binding events occurring on the surfaces of fluid-suspended MNPs that modify their magnetic relaxation behavior. Herein, we extrapolate a modest sensitivity to analyte of 100 ng/ml with the present setup using our rapid one-step bioassay. More importantly, we determine the size-distributions of the MNP systems with theoretical fits to our data obtained from the two complementary measurement modalities and demonstrate quantitative agreement between them.


Assuntos
Bioensaio/instrumentação , Separação Imunomagnética/instrumentação , Magnetismo/instrumentação , Nanopartículas/química , Nanotecnologia/instrumentação , Técnicas Biossensoriais/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Lab Chip ; 9(23): 3433-6, 2009 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-19904412

RESUMO

We demonstrate ElectroWetting-On-Dielectric (EWOD) transport and SQUID gradiometer detection of magnetic nanoparticles (MNPs) suspended in a 2 microl de-ionized water droplet. This proof-of-concept methodology constitutes the first development step towards a highly sensitive magnetic immunoassay platform with SQUID readout and droplet-based sample handling. Magnetic AC-susceptibility measurements were performed on MNPs with a hydrodynamic diameter of 100 nm using a high-Tc dc Superconducting Quantum Interference Device (SQUID) gradiometer as detector. We observed that the signal amplitude per unit volume is 2.5 times higher for a 2 microl sample droplet compared to a 30 microl sample volume.


Assuntos
Eletroumectação/instrumentação , Imunoensaio/tendências , Magnetismo , Técnicas Analíticas Microfluídicas/instrumentação , Desenho de Equipamento , Nanopartículas/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...