Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Indian Prosthodont Soc ; 14(4): 381-92, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25489162

RESUMO

The aim of this study is to assess the efficacy of microwave irradiation in disinfecting gypsum casts and also to compare its efficacy with validated method of chemical disinfection. The present study is an ex vivo study conducted on a sample of five irreversible hydrocolloid impressions in vitro and on ten patients gypsum casts in vivo following standard impression techniques to check the efficacy of microwave oven irradiation and compare its efficacy with standard chemical method of disinfection. Results were analysed using Mann-Whitney test and Wilcoxon signed rank test. Untreated gypsum casts showed cfu/ml counts with a median log value of 6, while microwave-irradiated ones had median cfu/ml counts of 0. Casts poured from chemically disinfected impressions demonstrated cfu/ml counts with a median log value of 5. Microwave irradiation was found to be effective in disinfecting gypsum casts when compared to chemical disinfectant in disinfecting dental impressions.

2.
J Contemp Dent Pract ; 13(3): 389-93, 2012 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-22918015

RESUMO

AIMS: To evaluate the effect of chemical disinfectant on the transverse strength of heat-polymerized acrylic resins subjected to mechanical and chemical polishing. MATERIALS AND METHODS: A total of 256 rectangular specimens (65 * 10 * 3 mm) 128 per resin (Lucitone-199 and Acralyn-H) were fabricated. One side of each specimen was not polished and the other was either mechanically (n = 96) or chemically (n = 96) polished and immersed for 10, 30 and 60 minutes in 2% alkaline glutaraldehyde. Mechanically polished (n = 32) and chemically polished (n = 32) control specimens were immersed only in distilled water. The transverse strength (N/mm(2)) was tested for failure in a universal testing machine, at a crosshead speed of 5 mm/min. Data were statistically analyzed using 2-way ANOVA and Student t-test. RESULTS: chemical polishing resulted in significantly lower transverse strength values than mechanical polishing. Lucitone- 199 resin demonstrated the highest overall transverse strength for the materials tested. Heat-polymerized acrylic resins either mechanically or chemically polished, did not demonstrate significant changes in transverse strength during immersion in the disinfecting solution tested, regardless of time of immersion. CONCLUSION: Lucitone-199 resin demonstrated the highest overall transverse strength for the materials tested and significantly stronger than Acralyn-H with either type of polishing following immersion in 2% alkaline glutaraldehyde. CLINICAL SIGNIFICANCE: There is a concern that immersion in chemical solutions often used for cleansing and disinfection of prostheses may undermine the strength and structure of denture base resins. In this study it was observed that, the transverse strength of samples of Lucitone-199 was higher than that of the samples of Acralyn-H. The chances of fracture of the denture made of Lucitone-199 are less than that of dentures made of Acralyn-H. The chemically polished dentures may be more prone to fracture than mechanically polished dentures.


Assuntos
Resinas Acrílicas , Desinfetantes de Equipamento Odontológico/efeitos adversos , Polimento Dentário , Análise do Estresse Dentário , Glutaral/efeitos adversos , Análise de Variância , Polimento Dentário/efeitos adversos , Polimento Dentário/métodos , Bases de Dentadura , Temperatura Alta , Teste de Materiais , Polimerização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...