Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Sleep Res ; 32(5): e13887, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36944532

RESUMO

The present study aimed to evaluate whether titration of fixed continuous positive airway pressure at home using telemonitoring produces patient outcomes equal to auto-adjusting positive airway pressure titration at home for patients with moderate obstructive sleep apnea. Patients were randomized with a 1:1 allocation ratio to receive either auto-adjusting positive airway pressure titration based on the median of the 95th percentile pressure across seven nights or fixed continuous positive airway pressure titration based on a fixed calculated pressure and specific adaptations after telemonitoring of device data after 3 and 7 nights. The results of the ambulatory titration were evaluated with in-laboratory polysomnography after 2 weeks. We hypothesized that fixed continuous positive airway pressure titration would be non-inferior to auto-adjusting positive airway pressure titration in respect to continuous positive airway pressure adherence at a 3-month follow-up. A non-inferiority margin of -0.75 hr was prespecified. One-hundred and four patients were randomly allocated to fixed continuous positive airway pressure (n = 52) and auto-adjusting positive airway pressure (n = 52) titration. The mean difference and the 95% confidence intervals in continuous positive airway pressure adherence after 3 months between the two arms were 0.80 (-0.08, 1.69) hr. The non-inferiority hypothesis was confirmed as the lower one-sided 97.5% confidence interval for the mean difference was above the prespecified margin. Patients in the fixed continuous positive airway pressure titration arm were titrated at significantly lower pressure level and had a significantly lower amount of average leaks compared with auto-adjusting positive airway pressure-titrated patients, while there was no difference in residual obstructive apnea-hypopnea index on polysomnography. Telemonitoring enables ambulatory continuous positive airway pressure titration with fixed pressure that is non-inferior to ambulatory titration with auto-adjusting pressure in patients with moderate obstructive sleep apnea.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Apneia Obstrutiva do Sono , Humanos , Pressão Positiva Contínua nas Vias Aéreas/métodos , Apneia Obstrutiva do Sono/terapia , Polissonografia
2.
Sleep Breath ; 26(1): 195-204, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-33942208

RESUMO

PURPOSE: Obstructive sleep apnea (OSA) is a prevalent and multifaceted disease. To date, the presence and severity of objectively identified comorbidities and their association with specific OSA phenotypes, CPAP adherence, and survival remain to be elucidated. The aim of this study is to cluster patients with OSA based on 10 clinically important objectively identified comorbidities, and to characterize the comorbidity clusters in terms of clinical and polysomnographic characteristics, CPAP adherence, and survival. STUDY DESIGN AND METHODS: Seven hundred ten consecutive patients starting CPAP for moderate-to-severe OSA were included. Comorbidities were based on generally accepted cutoffs identified in the peer-reviewed literature. Self-organizing maps were used to order patients based on presence and severity of their comorbidities and to generate clusters. RESULTS: The majority of patients were men (80%). They were generally middle-aged (52 years) and obese (BMI: 31.5 kg/m2). Mean apnea-hypopnea index (AHI) was 41 ± 20 per h of sleep. More than 94% of the patients had one or more comorbidities with arterial hypertension, dyslipidemia, and obesity being the most prevalent. Nine comorbidity clusters were identified. The clinical relevance of these comorbidity clusters was highlighted by the difference in symptoms, PSG parameters, and cardiovascular risk. Also, differences in CPAP adherence, improvements in ESS, and long-term survival were present between the clusters. CONCLUSION: Comorbidity prevalence in patients with OSA is high, and different comorbidity clusters, demonstrating differences in cardiovascular risk, CPAP adherence, and survival, can be identified. These results further substantiate the need for a comprehensive assessment of patients with OSA beyond the AHI.


Assuntos
Apneia Obstrutiva do Sono/complicações , Pressão Positiva Contínua nas Vias Aéreas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Índice de Gravidade de Doença , Apneia Obstrutiva do Sono/mortalidade , Apneia Obstrutiva do Sono/terapia , Taxa de Sobrevida
3.
Respir Med Res ; 80: 100832, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34130209

RESUMO

OBJECTIVE: SARS CoV-2 is an epidemic viral infection that can cause mild to severe lung involvement. Newly apprehended knowledge on thoracic imaging abnormalities and the growing clinical experience on the evolution of this disease make the radiographic follow-up of hospitalized patients relevant. The value of consecutive bedside lung ultrasonography in the follow-up of hospitalized patients with SARS CoV-2 pneumonia and its correlation with other clinical and laboratory markers needs to be evaluated. METHODS: We assessed 39 patients [age: 64 y(60.1-68.7)] with confirmed SARS CoV-2 pneumonia. A total of 24 patients were hospitalized until the follow-up test, 9 were discharged early and 6 required a transfer to critical care unit. Two ultrasound scans of the lung were performed on day 1 and 4 of patients' hospitalization. Primary endpoint was the magnitude of association between a global lung ultrasound score (LUS) and clinical and laboratory markers. Secondary endpoint was the association between the evolution of LUS with the corresponded changes in clinical and laboratory outcomes during hospitalization period. RESULTS: LUS score on admission was higher among the deteriorating patients and significantly (P=0.038-0.0001) correlated (Spearman's rho) with the levels of C-reactive protein (0.58), lymphocytes (-0.33), SpO2 (-0.48) and oxygen supplementation (0.48) upon admission. The increase in LUS score between the two scans was significantly correlated (0.544, P=0.006) with longer hospital stay. CONCLUSION: Lung ultrasound assessment can be a useful as an imaging modality for SARS CoV-2 patients. Larger studies are needed to further investigate the predictive role of LUS in the duration and the outcome of the hospitalization of these patients.


Assuntos
COVID-19 , Pneumonia , Hospitalização , Humanos , Pulmão/diagnóstico por imagem , Pessoa de Meia-Idade , Projetos Piloto , Prognóstico , SARS-CoV-2 , Ultrassonografia
4.
Sarcoidosis Vasc Diffuse Lung Dis ; 30(2): 143-5, 2013 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-24071886

RESUMO

We report a case of a sarcoidosis patient with bilateral calf and thigh stiffness who was noted to ha ve intense linear FDG uptake on a PET scan that localized to the fascia of his calves and theighs. His serum creatine kinase level was normal. Fasciitis has rarely been reported to be detected on FDG PET scans, and, to our knowledge, never in a sarcoidosis patient. FDG PET may have a role in identifying fasciitis or myositis when a patient has muscular complaints and no clinical or laboratory evidence of muscle injury.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons , Animais , Fasciite , Humanos , Miosite , Sarcoidose/diagnóstico por imagem
5.
Sarcoidosis Vasc Diffuse Lung Dis ; 30(1): 60-4, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24003536

RESUMO

INTRODUCTION: The Fatigue Assessment Scale (FAS) is a 10-item patient reported outcome (PRO) questionnaire that is used to measure fatigue in sarcoidosis. After several months of use, we began to question the reliability of the FAS in our clinic population. Therefore, we administered an additional fatigue PRO, the Patient Reported Outcomes Measurement Information Systems (PROMIS) Fatigue Instrument (PFI). Our hypothesis was that the internal consistency/reliability (Cronbach's alpha) of the PFI would be superior to the FAS in sarcoidosis patients because two of the ten FAS items (items #4 and #10) required reverse scoring (these items were scaled in the opposite direction to the other 8 items). METHODS: The FAS and PFI were administered during the same clinic visit to consecutive patients in our sarcoidosis clinic. We calculated a) the Cronbach's alpha for a) the FAS; b) the FAS without items #4 and #10; and c) the PFI. RESULTS: 107 consecutive sarcoidosis patients underwent FAS and PFI testing. The Cronbach's alpha was 0.740, 0.911, and 0.963 for the FAS, FAS with items #4 and #10 removed, and the PFI respectively. In female patients, the Cronbach's alpha of the FAS was 0.663, which is considered as "questionable" in terms of internal consistency. CONCLUSION: We found that the PFI had "excellent" consistency in our sarcoidosis clinic. The FAS did not demonstrate the same degree of internal consistency. The Cronbach's estimate of the FAS with items #4 and #10 removed was vastly superior to the FAS. These data support our contention that FAS items #4 and #10 detract from the internal consistency of this PRO. They also suggest that the PFI is superior to the FAS in terms of reliability.


Assuntos
Fadiga/diagnóstico , Avaliação de Resultados em Cuidados de Saúde , Sarcoidose/complicações , Inquéritos e Questionários , Adulto , Fadiga/etiologia , Feminino , Indicadores Básicos de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...