Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Indian J Anaesth ; 54(3): 242-5, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20885873

RESUMO

Cor-triatriatum is a rare congenital cardiac anomaly. It accounts for 0.1% of congenital heart diseases. Its association with multiple ventricular septal defects (VSD) is even rarer. A five-month-old baby was admitted with respiratory distress and failure to thrive. Clinical examination revealed diastolic murmur over mitral area. Chest X-ray showed cardiomegaly. Haematological and biochemical investigations were within normal limits. Electrocardiogram showed left atrial enlargement. 2D echo showed double-chambered left atrium (cor-triatriatum), atrial septal defect (ASD) and muscular VSD with moderate pulmonary arterial hypertension. The child was treated with 100% oxygen, diuretics and digoxin and was stabilized medically. We used balanced anaesthetic technique using oxygen, air, isoflurane, fentanyl, midazolam and vecuronium. Patient was operated under cardiopulmonary bypass (CPB) with moderate hypothermia. Through right atriotomy abnormal membrane in the left atrium was excised to make one chamber. VSD were closed with Dacron patches and ASD was closed with autologous pericardial patch. Patient tolerated the whole procedure well and was ventilated electively for 12h in the intensive care unit. He was discharged on the 10(th) postoperative day.

2.
Ann Card Anaesth ; 10(2): 121-6, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17644884

RESUMO

We prospectively compared four techniques of cardiac output measurement: bolus thermodilution cardiac output (TDCO), continuous cardiac output (CCO), pulse contour cardiac output (PiCCO), and Flowtrac (FCCO), simultaneously in fifteen patients undergoing off-pump coronary artery bypass grafting (OPCAB). All the patients received pulmonary artery catheter (capable of measuring both bolus thermodilution cardiac output and CCO), PiCCO arterial cannula in the left and FCCO in the right femoral artery. Cardiac indices (CI) were obtained every fifteen minutes by using all the four techniques. TDCO was treated as 'control' and the rest were treated as 'test' values. Interchangeability of techniques with TDCO was assessed by Bland and Altman plotting and mountain plot. Four hundred and thirty eight sets of data were obtained from fifteen patients. The values of cardiac output varied between 1 to 6.9 L/min. We found that the values of all the techniques were interchangeable. At certain times, the values of CI measured by both PiCCO and FCCO appeared erratic. The values of CI measured simultaneously appeared in the following descending order of accuracy; TDCO>CCO>FCCO>PiCCO (the % times TDCO correlated with CCO, FCCO, PiCCO was 93, 86 and 80 respectively). The bias and precision (in L/min) for CCO were 0.03, 0.06, PiCCO 0.13, 0.1 and flowtrac 0.15, 0.04 respectively suggesting interchangeability. We conclude that the cardiac output measured by CCO technique and the pulse contour as measured by PiCCO and FCCO were interchangeable with TDCO more than 80% of the times.


Assuntos
Débito Cardíaco , Ponte de Artéria Coronária sem Circulação Extracorpórea , Monitorização Intraoperatória/métodos , Cateterismo de Swan-Ganz , Feminino , Testes de Função Cardíaca , Humanos , Masculino , Monitorização Intraoperatória/instrumentação , Estudos Prospectivos , Pulso Arterial/instrumentação , Reprodutibilidade dos Testes , Termodiluição/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...