Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
Circ Cardiovasc Interv ; 10(7)2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28701488

RESUMO

BACKGROUND: Mechanical strength of bioresorbable scaffolds (BRS) is highly dependent on strut dimensions and polymer features. To date, the successful development of thin-walled BRS has been challenging. We compared the biomechanical behavior and vascular healing profile of a novel thin-walled (115 µm) sirolimus-eluting ultrahigh molecular weight amorphous poly-l-lactic acid-based BRS (APTITUDE, Amaranth Medical [AMA]) to Absorb (bioresorbable vascular scaffold [BVS]) using different experimental models. METHODS AND RESULTS: In vitro biomechanical testing showed no fractures in the AMA-BRS when overexpanded 1.3 mm above nominal dilatation values (≈48%) and lower number of fractures on accelerated cycle testing over time (at 21 K cycles=20.0 [19.5-20.5] in BVS versus 4.0 [3.0-4.3] in AMA-BRS). In the healing response study, 35 AMA-BRS and 23 BVS were implanted in 58 coronary arteries of 23 swine and followed-up to 180 days. Scaffold strut healing was evaluated in vivo using weekly optical coherence tomography analysis. At 14 days, the AMA-BRS demonstrated a higher percentage of embedded struts (71.0% [47.6, 89.1] compared with BVS 40.3% [20.5, 63.2]; P=0.01). At 21 days, uncovered struts were still present in the BVS group (3.8% [2.1, 10.2]). Histopathology revealed lower area stenosis (AMA-BRS, 21.0±6.1% versus BVS 31.0±4.5%; P=0.002) in the AMA-BRS at 28 days. Neointimal thickness and inflammatory scores were comparable between both devices at 180 days. CONCLUSIONS: A new generation thinned wall BRS displayed a more favorable biomechanical behavior and strut healing profile compared with BVS in normal porcine coronary arteries. This novel BRS concept has the potential to improve the clinical outcomes of current generation BRS.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Vasos Coronários/patologia , Intervenção Coronária Percutânea/instrumentação , Poliésteres/química , Sirolimo/administração & dosagem , Cicatrização , Animais , Biópsia , Angiografia Coronária , Vasos Coronários/efeitos dos fármacos , Vasos Coronários/fisiopatologia , Teste de Materiais , Modelos Animais , Peso Molecular , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Falha de Prótese , Sus scrofa , Fatores de Tempo , Tomografia de Coerência Óptica
2.
EuroIntervention ; 12(12): 1510-1518, 2016 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-27998842

RESUMO

AIMS: The vascular healing profile of polymers used in bioresorbable vascular scaffolds (BRS) has not been fully characterised in the absence of antiproliferative drugs. In this study, we aimed to compare the polymer biocompatibility profile and vascular healing response of a novel ultrahigh molecular weight amorphous PLLA BRS (FORTITUDE®; Amaranth Medical, Mountain View, CA, USA) against bare metal stent (BMS) controls in porcine coronary arteries. METHODS AND RESULTS: Following device implantation, optical coherence tomography (OCT) evaluation was performed at 0 and 28 days, and at one, two, three and four years. A second group of animals underwent histomorphometric evaluation at 28 and 90 days. At four years, both lumen (BRS 13.19±1.50 mm2 vs. BMS 7.69±2.41 mm2) and scaffold areas (BRS 15.62±1.95 mm2 vs. BMS 8.65±2.37 mm2) were significantly greater for BRS than BMS controls. The degree of neointimal proliferation was comparable between groups. Histology up to 90 days showed comparable healing and inflammation profiles for both devices. CONCLUSIONS: At four years, the novel PLLA BRS elicited a vascular healing response comparable to BMS in healthy pigs. Expansive vascular remodelling was evident only in the BRS group, a biological phenomenon that appears to be independent of the presence of antiproliferative drugs.


Assuntos
Implantes Absorvíveis , Vasos Coronários/cirurgia , Stents Farmacológicos , Neointima/patologia , Polímeros , Implantes Absorvíveis/efeitos adversos , Animais , Angiografia Coronária/métodos , Vasos Coronários/patologia , Stents Farmacológicos/efeitos adversos , Modelos Animais , Peso Molecular , Polímeros/efeitos adversos , Suínos , Tomografia de Coerência Óptica/métodos
3.
EuroIntervention ; 12(9): 1164-1173, 2016 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-27753601

RESUMO

AIMS: The aim of this study was to evaluate the biological efficacy of a novel lower-dose (2.5 µg/mm2) encapsulated paclitaxel nanocrystal-coated balloon (Nano-PCB) in the familial hypercholesterolaemic swine (FHS) model of iliofemoral in-stent restenosis. METHODS AND RESULTS: Nano-PCB pharmacokinetics were assessed in 20 femoral arteries (domestic swine). Biological efficacy was evaluated in ten FHS: 14 days following bare metal stent implantation each stent segment was randomised to a clinically available PCB (IN.PACT, n=14), the Nano-PCB (n=14) or an uncoated balloon (n=12). Angiographic, optical coherence tomography and histological evaluation was performed at 28 days after treatment. Arterial paclitaxel concentration was 120.7 ng/mg at one hour and 7.65 ng/mg of tissue at 28 days with the Nano-PCB. Compared to the control uncoated group, both PCBs significantly reduced percent area stenosis (Nano-PCB: 36.0±14.2%, IN.PACT: 29.3±9.2% vs control: 67.9±15.1%, p<0.001). Neointimal distribution in the entire stent length was more homogenous in the Nano-PCB. Histological evaluation showed comparable degrees of neointimal proliferation in both PCBs; however, the Nano-PCB showed slightly higher levels of neointimal maturity and endothelialisation. CONCLUSIONS: Lower-dose encapsulated paclitaxel nanocrystals delivered via a coated balloon displayed comparable biological efficacy with superior healing features compared to a clinically validated PCB technology.


Assuntos
Antineoplásicos/farmacologia , Artéria Femoral/efeitos dos fármacos , Oclusão de Enxerto Vascular , Hiperlipoproteinemia Tipo II , Artéria Ilíaca/efeitos dos fármacos , Paclitaxel/farmacologia , Stents , Cicatrização/efeitos dos fármacos , Angiografia , Angioplastia Coronária com Balão/instrumentação , Animais , Antineoplásicos/administração & dosagem , Modelos Animais de Doenças , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/patologia , Artéria Femoral/cirurgia , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/patologia , Artéria Ilíaca/cirurgia , Metais , Nanopartículas/administração & dosagem , Neointima , Paclitaxel/administração & dosagem , Doenças Vasculares Periféricas , Sus scrofa , Suínos , Tomografia de Coerência Óptica
4.
Circ Cardiovasc Interv ; 9(10)2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27694138

RESUMO

BACKGROUND: Clinically available bioresorbable scaffolds (BRS) rely on polymer crystallinity to achieve mechanical strength resulting in limited overexpansion capabilities and structural integrity when exposed to high-loading conditions. We aimed to evaluate the biomechanical behavior and vascular healing profile of a novel, sirolimus-eluting, high-molecular-weight, amorphous poly-l-lactic acid-based BRS (Amaranth BRS). METHODS AND RESULTS: In vitro biomechanical testing was performed under static and cyclic conditions. A total of 99 devices (65 Amaranth BRS versus 34 Absorb bioresorbable vascular scaffold [BVS]) were implanted in 99 coronary arteries of 37 swine for pharmacokinetics and healing evaluation at various time points. In the Absorb BVS, the number of fractures per scaffold seen on light microscopy was 6.0 (5.0-10.5) when overexpanded 1.0 mm above nominal values (≈34%). No fractures were observed in the Amaranth BRS group at 1.3 mm above nominal values (≈48% overexpansion). The number of fractures was higher in the Absorb BVS on accelerated cycle testing over time (at 24K cycles=5.0 [5.0-9.0] Absorb BVS versus 0.0 [0.0-0.5] Amaranth BRS). Approximately 90% of sirolimus was found to be eluted by 90 days. Optical coherence tomography analysis demonstrated lower percentages of late scaffold recoil in the Amaranth BRS at 3 months (Amaranth BRS=-10±16.1% versus Absorb BVS=10.7±13.2%; P=0.004). Histopathology analysis revealed comparable levels of vascular healing and inflammatory responses between both BRSs up to 6 months. CONCLUSIONS: New-generation high-molecular-weight amorphous poly-l-lactic acid scaffolds have the potential to improve the clinical performance of BRS and provide the ideal platform for the future miniaturization of the technology.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/farmacocinética , Materiais Revestidos Biocompatíveis , Vasos Coronários/efeitos dos fármacos , Intervenção Coronária Percutânea/instrumentação , Poliésteres/química , Sirolimo/farmacocinética , Cicatrização/efeitos dos fármacos , Animais , Biópsia , Fármacos Cardiovasculares/administração & dosagem , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Teste de Materiais , Modelos Animais , Peso Molecular , Neointima , Intervenção Coronária Percutânea/efeitos adversos , Falha de Prótese , Sirolimo/administração & dosagem , Suínos , Porco Miniatura , Tomografia de Coerência Óptica
5.
EuroIntervention ; 12(6): 740-7, 2016 08 20.
Artigo em Inglês | MEDLINE | ID: mdl-26428893

RESUMO

AIMS: Among antirestenotic compounds, sirolimus displays a superior safety profile compared to paclitaxel, but its pharmacokinetic properties make it a challenging therapeutic candidate for single-time delivery. Herein we evaluate the feasibility of delivery, long-term retention and vascular effects of sirolimus nanoparticles delivered through a novel porous angioplasty balloon in normal porcine arteries and in a swine model of in-stent restenosis (ISR). METHODS AND RESULTS: Sirolimus nanoparticle formulation was delivered via porous balloon angioplasty to 753 coronary artery segments for pharmacokinetic studies and 26 segments for biological effect of sirolimus delivery in different clinical scenarios (de novo [n=8], ISR [n=6] and following stent implantation [n=12]). Sirolimus coronary artery concentrations were above the target therapeutic level of 1 ng/mg after 26 days, and were >100-fold higher in coronary artery treatment sites than in distal myocardium and remote tissues at all time points. At 28 days, reduction in percent stenosis in formulation-treated sites compared to balloon angioplasty treatment was noted in all three clinical scenarios, with the largest effect seen in the de novo study. CONCLUSIONS: Local coronary delivery of sirolimus nanoparticles in the porcine model using a novel porous balloon delivery system achieved therapeutic long-term intra-arterial drug levels without significant systemic residual exposure.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Antibióticos Antineoplásicos/administração & dosagem , Reestenose Coronária/prevenção & controle , Sirolimo/administração & dosagem , Animais , Antibióticos Antineoplásicos/farmacocinética , Vasos Coronários/efeitos dos fármacos , Feminino , Masculino , Nanopartículas , Sirolimo/farmacocinética , Suínos
6.
JACC Cardiovasc Interv ; 8(8): 1115-1123, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26117470

RESUMO

OBJECTIVES: This study sought to compare the effect of paclitaxel-coated balloon (PCB) concentration on tissue levels and vascular healing using 3 different PCB technologies (In.Pact Pacific = 3 µg/mm(2), Lutonix = 2 µg/mm(2) and Ranger = 2 µg/mm(2)) in the experimental setting. BACKGROUND: The optimal therapeutic dose for PCB use has not been determined yet. METHODS: Paclitaxel tissue levels were measured up to 60 days following PCB inflation (Ranger and In.Pact Pacific) in the superficial femoral artery of healthy swine (18 swine, 36 vessels). The familial hypercholesterolemic swine model of superficial femoral artery in-stent restenosis (6 swine, 24 vessels) was used in the efficacy study. Two weeks following bare-metal stent implantation, each in-stent restenosis site was randomly treated with a PCB or an uncoated control balloon (Sterling). Quantitative vascular analysis and histology evaluation was performed 28 days following PCB treatment. RESULTS: All PCB technologies displayed comparable paclitaxel tissue levels 4 h following balloon inflation. At 28 days, all PCB had achieved therapeutic tissue levels; however, the In.Pact PCB resulted in higher tissue concentrations than did the other PCB groups at all time points. Neointimal inhibition by histology was decreased in all PCB groups compared with the control group, with a greater decrease in the In.Pact group. However, the neointima was more mature and contained less peri-strut fibrin deposits in both 2-µg/mm(2) PCB groups. CONCLUSIONS: Compared with the clinically established PCB dose, lower-dose PCB technologies achieve lower long-term tissue levels but comparable degrees of neointimal inhibition and fewer fibrin deposits. The impact of these findings in restenosis reduction and clinical outcomes needs to be further investigated.


Assuntos
Fármacos Cardiovasculares/farmacocinética , Materiais Revestidos Biocompatíveis , Procedimentos Endovasculares/instrumentação , Artéria Femoral/efeitos dos fármacos , Hiperlipoproteinemia Tipo II/complicações , Paclitaxel/farmacocinética , Doença Arterial Periférica/terapia , Stents , Dispositivos de Acesso Vascular , Cicatrização/efeitos dos fármacos , Animais , Fármacos Cardiovasculares/administração & dosagem , Constrição Patológica , Modelos Animais de Doenças , Procedimentos Endovasculares/efeitos adversos , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/metabolismo , Artéria Femoral/patologia , Fibrina/metabolismo , Metais , Neointima , Paclitaxel/administração & dosagem , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/etiologia , Doença Arterial Periférica/metabolismo , Radiografia , Suínos , Distribuição Tecidual
7.
Int J Cardiovasc Imaging ; 31(6): 1097-106, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25922149

RESUMO

Intracoronary optical frequency domain imaging (OFDI), requires the displacement of blood for clear visualization of the artery wall. Radiographic contrast agents are highly effective at displacing blood however, may increase the risk of contrast-induced nephropathy. Flushing media viscosity, flow rate, and flush duration influence the efficiency of blood displacement necessary for obtaining diagnostic quality OFDI images. The aim of this work was to determine the optimal flushing parameters necessary to reliably perform intracoronary OFDI while reducing the volume of administered radiographic contrast, and assess the influence of flushing media choice on vessel wall measurements. 144 OFDI pullbacks were acquired together with synchronized EKG and intracoronary pressure wire recordings in three swine. OFDI images were graded on diagnostic quality and quantitative comparisons of flushing efficiency and intracoronary cross-sectional area with and without precise refractive index calibration were performed. Flushing media with higher viscosities resulted in rapid and efficient blood displacement. Media with lower viscosities resulted in increased blood-media transition zones, reducing the pullback length of diagnostic quality images obtained. Flushing efficiency was found to increase with increases in flow rate and duration. Calculations of lumen area using different flushing media were significantly different, varying up to 23% (p < 0.0001). This error was eliminated with careful refractive index calibration. Flushing media viscosity, flow rate, and flush duration influence the efficiency of blood displacement necessary for obtaining diagnostic quality OFDI images. For patients with sensitivity to contrast, to reduce the risk of contrast induced nephrotoxicity we recommend that intracoronary OFDI be conducted with flushing solutions containing little or no radiographic contrast. In addition, our findings show that careful refractive index compensation should be performed, taking into account the specific contrast agent used, in order to obtain accurate intravascular OFDI measurements.


Assuntos
Cateterismo Cardíaco , Meios de Contraste/administração & dosagem , Vasos Coronários/patologia , Irrigação Terapêutica/métodos , Tomografia de Coerência Óptica , Animais , Circulação Coronária , Vasos Coronários/fisiopatologia , Eletrocardiografia , Feminino , Modelos Animais , Intervenção Coronária Percutânea/instrumentação , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Stents , Suínos , Fatores de Tempo , Viscosidade
8.
EuroIntervention ; 10(12): 1480-7, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25912393

RESUMO

AIMS: To test the feasibility of a thoracoscopically assisted, off-pump, transcatheter ventricular reconstruction (TCVR) approach in an ovine model of left ventricular (LV) anteroapical aneurysm. METHODS AND RESULTS: Myocardial infarction (MI) was induced by coil occlusion of the middle left anterior descending artery and diagonals. Two months after MI creation, TCVR was performed via a minimal thoracotomy in eight sheep. Under endoscopic and fluoroscopic guidance, trans-interventricular septal puncture was performed from the LV epicardial scar. A guidewire was externalised via a snare placed in the right ventricle from the external jugular vein. An internal anchor was inserted over the wire and positioned on the right ventricular septum and an external anchor was deployed on the LV anterior epicardium. Serial pairs of anchors were placed and plicated together to exclude the scar completely. Immediately after TCVR, echocardiography showed LV end-systolic volume decreased from pre-procedure 58.8±16.6 ml to 25.1±7.6 ml (p<0.01) and the ejection fraction increased from 32.0±7.3% to 52.0±7.5% (p<0.01). LV twist significantly improved (3.83±2.21 vs. pre-procedure -0.41±0.94, p=0.01) and the global peak-systolic longitudinal strain increased from -5.64% to -10.77% (p<0.05). CONCLUSIONS: TCVR using minimally invasive access techniques on the off-pump beating heart is feasible and resulted in significant improvement in LV performance.


Assuntos
Cateterismo Cardíaco/métodos , Aneurisma Cardíaco/cirurgia , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Toracoscopia/métodos , Função Ventricular Esquerda , Animais , Infarto Miocárdico de Parede Anterior/complicações , Modelos Animais de Doenças , Estudos de Viabilidade , Aneurisma Cardíaco/etiologia , Insuficiência Cardíaca/etiologia , Ovinos , Resultado do Tratamento
10.
Catheter Cardiovasc Interv ; 86(1): 173-81, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24130158

RESUMO

OBJECTIVES: Aimed to evaluate the feasibility of deployment and healing response of a novel transcatheter left atrial appendage (LAA) occlusion device in the canine model BACKGROUND: LAA occlusion is proposed to reduce the risk of stroke in atrial fibrillation patients METHODS: Transseptal puncture and device deployment was guided under fluoroscopy and transesophageal echocardiography (TEE) in five dogs. First, a distal cylindrical bulb occluder was released and secured to the appendage wall with hooks. Subsequently, a proximal sail was unfolded, covering the LAA ostium. Rotational angiography, TEE, and histology outcomes were assessed 30 days following implantation RESULTS: Pre-operative TEE revealed the mean diameter of the LAA ostium to be 17.2 ± 1.6 mm with a depth of 18.5 ± 1.7 mm. The landing zone for the distal bulb was measured to be 12.8 ± 1.3 mm. The mean bulb diameter at implant was 16.8 ± 1.8 mm. Post-operative TEE showed adequate positioning and successful LAA occlusion with all implanted devices. Pericardial effusion requiring pericardiocentesis was seen in one animal following device implantation. At 30 days, TEE revealed full occlusion of all LAA ostia with the exception of a minimal peri-device leak (<3 mm) observed in one animal. No pericardial effusion or device-related thrombus formation was found at termination. Histological analysis confirmed circumferential occlusion of all appendages and complete neointimal coverage on the luminal aspect of the occluder CONCLUSION: The percutaneous delivery of a novel self-positioning LAA occlusion device is feasible and safe in a canine model. At 30 days, all devices displayed complete healing and occlusion of the LAA without any device related adverse events.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/instrumentação , Acidente Vascular Cerebral/prevenção & controle , Suturas , Animais , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Cateterismo Cardíaco , Modelos Animais de Doenças , Cães , Ecocardiografia Transesofagiana , Fluoroscopia , Ligadura/instrumentação , Acidente Vascular Cerebral/etiologia
11.
EuroIntervention ; 10(8): 1002-8, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25308298

RESUMO

AIMS: The efficacy of paclitaxel-coated balloons (PCB) for the treatment of superficial femoral artery (SFA) disease has been demonstrated in the clinical setting. Due to the high frequency of arterial calcification found in this vascular territory, the adjunctive use of atherectomy plus PCB has been proposed. In this study, we aimed to evaluate the biological effect on vascular healing and drug retention of this combination approach in the familial hypercholesterolaemic swine (FHS) model of femoral artery stenosis. METHODS AND RESULTS: Eleven femoral arteries (six superficial and five profunda arteries) were included. Vessels were injured (x2) over a 28-day period and all animals were maintained on a high cholesterol diet for 60 days following initial injury. Vessels were randomised to PCB (n=5) or orbital atherectomy system (OAS) plus PCB (n=6). At 28 days following therapy, vessels were followed with angiography, intravascular ultrasound (IVUS) and optical coherence tomography (OCT). Vessels were harvested for histological and pharmacokinetic analysis. Angiographic findings were comparable at termination between both groups. The OCT findings were comparable at termination. There were no differences in the vascular healing profile between both groups. The paclitaxel levels at termination were comparable between both groups (PCB=5.16 vs. OAS+PCB=3.03 ng/mg). CONCLUSIONS: In the experimental setting, the combination of OAS+PCB appears to be safe by demonstrating a vascular healing profile and drug tissue levels comparable to PCB only. The vascular effect of PCB may be enhanced by the use of OAS by decreasing plaque burden and cholesterol crystals.


Assuntos
Angioplastia com Balão/métodos , Antineoplásicos Fitogênicos/farmacocinética , Aterectomia/métodos , Artéria Femoral/cirurgia , Paclitaxel/farmacocinética , Doença Arterial Periférica/cirurgia , Cicatrização/efeitos dos fármacos , Animais , Antineoplásicos Fitogênicos/farmacologia , Terapia Combinada , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Modelos Animais de Doenças , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/efeitos dos fármacos , Hiperlipoproteinemia Tipo II/complicações , Paclitaxel/farmacologia , Doença Arterial Periférica/etiologia , Suínos , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção
12.
Catheter Cardiovasc Interv ; 83(3): 397-404, 2014 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-25295313

RESUMO

Background: Self-expanding stents (SES) are reemerging as therapeutic alternatives to treat coronary artery disease. It has been proposed that SES can improve clinical outcomes by inducing less injury at implantation and achieving better vessel wall apposition.To date, little data exists comparing the vascular response to both methods of deployment in a controlled experimental setting. Objective: To quantify differences in vascular injury and healing between second-generation SES and balloon-expandable stents (BES) and the effects of balloon post-dilatation in a porcine coronary model. Methods: Seventy-five bare SES (AXXESS or vProtect) and 42 BES (Vision) were implanted in porcine coronaries. A subset of these received balloon post-dilatation(SES 1 D 5 22, BES 1 D 5 20). Follow-up was scheduled at 30 (BES 5 10, BES 1 D 56, SES 5 19, SES 1 D 5 8), 90 (BES 5 6, BES 1 D 5 8, SES 5 19, SES 1 D 5 8), and 180 days (BES 5 6, BES 1 D 5 6, SES 5 15, SES 1 D 5 6). Results: In vivo imaging and histological analysis showed that neointimal formation peaks early (30 days) in BES. Conversely, for SES, the peak occurred later (90 days). However, the neointimal formation achieved in either group equalized at 180 days. For SES, post-dilatation shortened the peak of neointimal formation to 30 days. Conversely, for BES, post-dilatation delayed the peak of neointimal formation to 90 days. At 30 days, histology showed that SES had significantly less injury. However, at 90 days, injury scores tended to be higher for SES. By 180 days, injury scores were comparable between both groups. Conclusions: The mechanism of stent expansion influences the degree of vascular injury and healing. The synergistic use of balloon post dilatation changes the dynamics of healing and may impact the potential beneficial effects inherent to SES technologies.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/cirurgia , Stents , Túnica Íntima/fisiopatologia , Lesões do Sistema Vascular/prevenção & controle , Cicatrização , Angioplastia Coronária com Balão/métodos , Animais , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/fisiopatologia , Modelos Animais de Doenças , Desenho de Equipamento , Escala de Gravidade do Ferimento , Stents/efeitos adversos , Stents/normas , Suínos , Fatores de Tempo , Túnica Íntima/lesões , Grau de Desobstrução Vascular , Lesões do Sistema Vascular/etiologia
13.
Open Heart ; 1(1): e000117, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25332821

RESUMO

BACKGROUND: The efficacy of paclitaxel-coated balloons (PCB) for restenosis prevention has been demonstrated in humans. However, the mechanism of action for sustained drug retention and biological efficacy following single-time drug delivery is still unknown. METHODS AND RESULTS: The pharmacokinetic profile and differences in drug concentration (vessel surface vs arterial wall) of two different paclitaxel coating formulations (3 µg/mm(2)) displaying opposite solubility characteristics (CC=crystalline vs AC=amorphous) were tested in vivo and compared with paclitaxel-eluting stents (PES). Also, the biological effect of both PCB formulations on vascular healing was tested in the porcine coronary injury model. One hour following balloon inflation, both formulations achieved similar arterial paclitaxel levels (CC=310 vs AC=245 ng/mg; p=NS). At 24 h, the CC maintained similar tissue concentrations, whereas the AC tissue levels declined by 99% (p<0.01). At this time point, arterial levels were 20-fold (CC) and 5-fold (AC) times higher compared to the PES group (p<0.05). At 28 days, arterial levels retained were 9.2% (CC) and 0.04% (AC, p<0.01) of the baseline levels. Paclitaxel concentration on the vessel surface was higher in the CC at 1 (CC=36.7% vs AC=13.1%, p<0.05) and 7 days (CC=38.4% vs AC=11%, p<0.05). In addition, the CC induced higher levels of neointimal inhibition, fibrin deposition and delayed healing compared with the AC group. CONCLUSIONS: The presence of paclitaxel deposits on the vessel surface driving diffusion into the arterial tissue in a time-dependent fashion supports the mechanism of action of PCB. This specific pharmacokinetic behaviour influences the patterns of neointimal formation and healing.

14.
Coron Artery Dis ; 25(7): 595-601, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25013949

RESUMO

BACKGROUND: Peri-strut low-intensity area (PLI) is a common imaging finding during the evaluation of in-stent neointima using optical coherence tomography (OCT). We aimed to determine the biological significance of PLI by comparing in-vivo OCT images with the corresponding histological sections obtained from the familial hypercholesterolemic swine model of coronary stenosis. METHODS: A total of 26 coronary vessels of nine familial hypercholesterolemic swine were injured with 30% balloon overstretch and then immediately followed by everolimus eluting or bare metal stent placement at 20% overstretch. At 30 days, all stented vessels were subjected to in-vivo OCT analysis and were harvested for histological evaluation. For OCT analysis, stent cross-sections (three per stent) were categorized into presence (PLI+) or absence (PLI-) of PLI. In histology, inflammation and fibrin deposition were scored semiquantitatively from 0 (none) to 3 (severe). RESULTS: PLI was found in 64.9% of stent sections. Peri-strut inflammation was more frequently observed in OCT sections PLI (+) compared with PLI (-) (56.0 vs. 7.4%, P=0.01). In contrast, peri-strut fibrin deposits was similar in both groups (PLI+=58.0% vs. PLI-=59.3%, P=0.94). Histological neointimal thickness was significantly higher in PLI (+) sections (mean±SE: 0.68±0.06 vs. 0.34±0.02 mm; P<0.01), yielding a higher percent area stenosis compared with PLI (-) (mean±SE: 59.0±4.4 vs. 34.1±2.2%, P<0.01). The PLI diagnostic sensitivity and specificity for inflammation were 80 and 76.1%, respectively (>56% PLI, area under the curve=0.86, P<0.01), whereas for fibrin deposition, the sensitivity and specificity were 42.2 and 76.1%, respectively (area under the curve=0.56, P=NS). Area under the receiver operating characteristic curve was significantly higher for identifying inflammation than fibrin (0.86 vs. 0.56, P<0.01). The severity of PLI correlated with the neointimal thickness when assessed by OCT (R=0.79, P<0.001). CONCLUSION: The presence of PLI in OCT correlates with neointimal thickness and appears to have a diagnostic value in the recognition of peri-strut inflammation, therefore possibly serving as a surrogate for in-vivo assessment of stent efficacy.


Assuntos
Doença da Artéria Coronariana , Reestenose Coronária/patologia , Vasos Coronários/patologia , Oclusão de Enxerto Vascular/patologia , Hiperlipoproteinemia Tipo II , Inflamação/patologia , Neointima/patologia , Tomografia de Coerência Óptica , Animais , Reestenose Coronária/metabolismo , Vasos Coronários/metabolismo , Modelos Animais de Doenças , Stents Farmacológicos , Fibrina/metabolismo , Oclusão de Enxerto Vascular/metabolismo , Hiperplasia , Inflamação/metabolismo , Masculino , Neointima/metabolismo , Stents , Suínos
15.
Coron Artery Dis ; 25(3): 198-207, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24642807

RESUMO

BACKGROUND: The utility of animal models for the prediction of drug-eluting stent (DES) efficacy in human clinical trials is still unclear. The familial hypercholesterolemic swine (FHS) model has been shown to induce a human-like neointimal response to bare metal stent (BMS) implantation. However, its utility to discriminate efficacy signals following DES implantation is unknown. In this study, we aimed to test the efficacy and healing response of several everolimus-eluting stent (EES) platforms in the coronary territory of the FHS. METHODS: A total of 19 EES platforms (SYNERGY=6, SYNERGY½-dose=7, and PROMUS Element=6) and an identical BMS control (Element=6) were implanted into the coronary arteries of nine FHS. All implants were performed under intravascular ultrasound guidance using a 1.2 : 1 overstretch ratio. At 30 days, the vascular response to the implant was evaluated by quantitative coronary angiography, optical coherence tomography, and histology. RESULTS: At 28 days, all EES platforms showed a significant decrease in angiographic late lumen loss (between 27 and 37%) compared with the BMS control group. This finding was confirmed both by optical coherence tomography (mean neointimal thickness=28-42% reduction) and by histology (mean neointimal thickness=44-55% reduction). All EES platforms showed similar degrees of neointimal inhibition. The presence of moderate to severe para-strut inflammation was observed in 83% of the stent sections in the BMS group compared with 28.6% in the SYNERGY½-dose group and 0% in the SYNERGY and PROMUS groups (P=0.0002). There was a 68-95% reduction in MMP9 expression in the media in all EES platforms compared with the BMS controls. The presence of mild to moderate para-strut fibrin deposits ranged from 66.7 to 83.4% in all EES platforms compared with 16.7% in the EBMS group. CONCLUSION: The FHS coronary injury model showed the efficacy of several EES platforms compared with an identical BMS control. Everolimus eluted from different polymeric platforms showed lower levels of inflammation and slightly higher fibrin deposits compared with BMS controls.


Assuntos
Vasos Coronários/patologia , Modelos Animais de Doenças , Stents Farmacológicos , Hiperlipoproteinemia Tipo II , Neointima , Sirolimo/análogos & derivados , Animais , Implante de Prótese Vascular/métodos , Angiografia Coronária/métodos , Stents Farmacológicos/efeitos adversos , Stents Farmacológicos/normas , Everolimo , Humanos , Hiperlipoproteinemia Tipo II/diagnóstico , Hiperlipoproteinemia Tipo II/terapia , Imunossupressores/farmacologia , Masculino , Modelos Cardiovasculares , Neointima/diagnóstico , Neointima/etiologia , Polímeros/farmacologia , Sirolimo/farmacologia , Suínos , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento , Ultrassonografia de Intervenção/métodos
16.
Eur Heart J Cardiovasc Imaging ; 15(3): 292-8, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24022066

RESUMO

AIMS: Although optical coherence tomography (OCT) is capable to detect microscopic peri-strut changes that seem to be related to neointimal inhibition and healing, its ability to characterize these components is still limited. In this study, we aimed to compare different OCT morphological characteristics with different in-stent neointimal tissue types analysed by histology. METHODS: A total of 69 stents (39 drug eluting and 30 bare metal stents) were implanted in coronary arteries of 27 swine. By OCT, neointimal type was classified as homogeneous, heterogeneous, or layered according to its pattern of backscatter and optical intensity. The resulting optical patterns were correlated with several histological findings [external elastic lamina (EEL) disruption, fibrin deposition, circumferential rim of peri-strut inflammatory cell infiltration, and fibrous connective deposition] in every single cross-section (CS) analysed. RESULTS: A total of 197 matched OCT and histological CS were analysed. The heterogeneous (0.44 ± 0.21 mm) and layered (0.65 ± 0.16 mm) patterns had a significantly higher degree of neointimal thickness compared with the homogeneous pattern (0.25 ± 0.16 mm, P < 0.001). Fibrous connective tissue deposition was more frequently present in the homogeneous pattern (71.6%, P < 0.001), whereas significant fibrin deposits were more commonly seen in the heterogeneous pattern (56.9%, P = 0.007). Peri-strut inflammation was less frequently found in the homogeneous pattern (19.8%, P < 0.001) in comparison with the layered (73.9%) or heterogeneous patterns (43.1%). The presence of EEL rupture was also more commonly seen in layered (73.9%) and heterogeneous (46.6%) patterns than in the homogeneous pattern (22.4%, P < 0.001). CONCLUSION: The optical characteristics of neointimal formation seen in OCT properly correlated with the presence of several histological findings involved in stent healing. The biological implications of these findings in clinical outcomes require further investigation.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Reestenose Coronária/patologia , Neointima/patologia , Stents , Tomografia de Coerência Óptica/métodos , Angioplastia Coronária com Balão/efeitos adversos , Animais , Biópsia por Agulha , Proliferação de Células , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Modelos Animais de Doenças , Stents Farmacológicos , Feminino , Imuno-Histoquímica , Masculino , Metais , Neointima/diagnóstico por imagem , Distribuição Aleatória , Suínos , Resultado do Tratamento
17.
J Thorac Cardiovasc Surg ; 148(1): 225-31, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24084284

RESUMO

OBJECTIVE: The loss of normal apical rotation is associated with left ventricular (LV) remodeling and systolic dysfunction in patients with congestive heart failure after myocardial infarction. The objective of the present study was to evaluate the effect of epicardial ventricular reconstruction, an off-pump, less-invasive surgical reshaping technique, on myocardial strain, LV twist, and the potential alteration of myocardial fiber orientation in an ovine model of LV anteroapical aneurysm. METHODS: LV anteroapical myocardial infarction was induced by coil embolization of the left anterior descending artery. Eight weeks after occlusion, epicardial ventricular reconstruction was performed using left thoracotomy under fluoroscopic guidance in 8 sheep to completely exclude the scar. The peak systolic longitudinal/circumferential strains and LV twist were evaluated using speckle tracking echocardiography before (baseline), after device implantation, and at 6 weeks of follow-up. RESULTS: Epicardial ventricular reconstruction was completed in all sheep without any complications. Immediately after device implantation, LV twist significantly increased (4.18 ± 1.40 vs baseline 1.97 ± 1.92; P = .02). The ejection fraction had increased 17% and LV end-systolic volume had decreased 40%. The global longitudinal strain increased from -5.3% to -9.1% (P < .05). Circumferential strain increased in both middle and apical LV segments, with the greatest improvement in the inferior lateral wall (from -11.4% to -20.6%, P < .001). These effects were maintained ≥6 weeks after device implantation without redilation. CONCLUSIONS: Less invasive than alternative therapies, epicardial ventricular reconstruction on the off-pump beating heart can restore LV twist and systolic strain and reverse LV remodeling in an ovine anteroapical aneurysm model.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Aneurisma Cardíaco/cirurgia , Ventrículos do Coração/cirurgia , Pericárdio/cirurgia , Procedimentos de Cirurgia Plástica , Função Ventricular Esquerda , Animais , Fenômenos Biomecânicos , Modelos Animais de Doenças , Aneurisma Cardíaco/diagnóstico , Aneurisma Cardíaco/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Pericárdio/diagnóstico por imagem , Pericárdio/fisiopatologia , Recuperação de Função Fisiológica , Ovinos , Volume Sistólico , Sístole , Fatores de Tempo , Torção Mecânica , Ultrassonografia , Remodelação Ventricular
18.
EuroIntervention ; 9(4): 510-6, 2013 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-23965356

RESUMO

AIMS: The routine use of paclitaxel-coated balloons (PCB) in combination with bare metal stents (BMS) in de novo coronary lesions has been questioned. In this study, we aimed to compare the vascular response of BMS implanted using a second-generation PCB (BMS+PCB) with the TAXUS stent (PES) and a BMS control (BMS) in the familial hypercholesterolaemic swine (FHS) model of coronary injury. METHODS AND RESULTS: A total of 17 stents (PES=6, BMS+PCB=6, and BMS=5) were implanted in the coronary territory of 10 FHS using a 20% overstretch injury ratio. Imaging evaluation (QCA and IVUS) was conducted in all animals at baseline and 28 days following stent implantation. Following terminal imaging all animals were euthanised and stented coronary segments harvested for histological evaluation. At 28 days, the lowest degree of percentage diameter stenosis by QCA was achieved by the PES (2.9 ± 9%) followed by the BMS+PCB (9.5 ± 16.4%) and the BMS group (25.65 ± 18.7%, p<0.05). In histology, percentage area of stenosis (BMS+PCB=29.6 ± 6.4% vs. PES=21.5 ± 3.3% vs. BMS=55.2 ± 12.9%; p<0.01) and neointimal thickness (BMS+PCB=0.26 ± 0.1 mm vs. PES=0.21 ± 0.1 mm vs. BMS=0.59 ± 0.2 mm; p<0.01) were significantly reduced in both paclitaxel groups in comparison to BMS controls. Both BMS+PCB and BMS groups had higher endothelialisation scores (PES=1.50 ± 0.9 vs. BMS+PCB=2.73 ± 0.4 vs. BMS=3.00; p<0.05) and lower peri-strut inflammatory scores (PES=0.83 ± 0.4 vs. BMS+PCB=0.20 ± 0.2 vs. BMS=0.43 ± 0.6, p<0.05) when compared to PES. Neointima maturity (PCB+BMS: 2.00 [2-2.4] vs. PES: 1.00 [0.3-1] vs. BMS: 3.00, p<0.05) and fibrin deposition (PCB+BMS: 1.40 ± 0.3 vs. PES: 2.17 ± 0.7 vs. BMS: 0.27 ± 0.3, p<0.05) scores in PCB+BMS appeared to fall between the PES and the BMS ranges. CONCLUSIONS: In the FHS coronary injury model, BMS implantation using a PCB yields a degree of neointimal inhibition comparable to the PES. The BMS+PCB combination presented lower degrees of inflammation and fibrin deposition; however, signs of delayed healing were still present.


Assuntos
Fármacos Cardiovasculares/uso terapêutico , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Iohexol/análogos & derivados , Paclitaxel/uso terapêutico , Polímeros/uso terapêutico , Angioplastia Coronária com Balão/métodos , Animais , Constrição Patológica/patologia , Constrição Patológica/terapia , Doença da Artéria Coronariana/patologia , Vasos Coronários/patologia , Modelos Animais de Doenças , Neointima/terapia , Suínos
19.
JACC Cardiovasc Interv ; 6(8): 883-90, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23968706

RESUMO

OBJECTIVES: This study sought to evaluate vascular drug uptake, distribution and response of second-generation paclitaxel coated balloon (PCB) (Cotavance, MEDRAD Interventional, Indianola, Pennsylvania) and compare it with first-generation technology, containing identical excipient and drug concentration. BACKGROUND: Original PCB technologies displayed a heterogeneous deposition of crystalline paclitaxel-iopromide inside the balloon folds, whereas second-generation PCBs consisted of more homogeneous, circumferential coatings. METHODS: Paclitaxel tissue uptake was assessed in 20 iliofemoral arteries of a domestic swine. Vascular healing response was assessed in the familial hypercholesterolemic model of iliofemoral in-stent restenosis. Three weeks after bare-metal stent implantation, vascular segments were randomly revascularized with first-generation PCBs (n = 6), second-generation PCBs (n = 6), or plain balloon angioplasty (PBA) (n = 6). At 28 days, angiographic and histological evaluation was performed in all treated segments. RESULTS: One-hour paclitaxel tissue uptake was 42% higher in the second-generation PCBs (p = 0.03) and resulted in more homogeneous segment-to-segment distribution compared with first-generation PCBs. Both angiography (percentage of diameter stenosis: second-generation 11.5 ± 11% vs. first-generation 21.9 ± 11% vs. PBA 46.5 ± 10%; p < 0.01) and histology (percentage of area stenosis: second-generation 50.5 ± 7% vs. first-generation 54.8 ± 18% vs. PBA 78.2 ± 9%; p < 0.01) showed a decrease in neointimal proliferation in both PCB groups. Histological variance of the percentage of area stenosis was lower in second-generation compared with first-generation PCBs (51.7 vs. 328.3; p = 0.05). The presence of peristrut fibrin deposits (0.5 vs. 2.4; p < 0.01) and medial smooth muscle cell loss (0 vs. 1.7; p < 0.01) were lower in the second-generation compared with first-generation PCBs. CONCLUSIONS: In the experimental setting, second-generation PCB showed a comparable efficacy profile and more favorable vascular healing response when compared to first-generation PCB. The clinical implications of these findings require further investigation.


Assuntos
Angioplastia com Balão/instrumentação , Arteriopatias Oclusivas/tratamento farmacológico , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Meios de Contraste , Artéria Femoral/efeitos dos fármacos , Artéria Ilíaca/efeitos dos fármacos , Iohexol/análogos & derivados , Paclitaxel/administração & dosagem , Dispositivos de Acesso Vascular , Cicatrização/efeitos dos fármacos , Angioplastia com Balão/efeitos adversos , Animais , Arteriopatias Oclusivas/diagnóstico , Arteriopatias Oclusivas/etiologia , Fármacos Cardiovasculares/farmacocinética , Proliferação de Células/efeitos dos fármacos , Constrição Patológica , Modelos Animais de Doenças , Desenho de Equipamento , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/metabolismo , Artéria Femoral/patologia , Fibrose , Hiperlipoproteinemia Tipo II/complicações , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/metabolismo , Artéria Ilíaca/patologia , Neointima , Paclitaxel/farmacocinética , Radiografia , Sus scrofa , Distribuição Tecidual
20.
Transl Res ; 162(6): 381-9, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23911638

RESUMO

Catheter-based renal artery denervation has demonstrated to be effective in decreasing blood pressure among patients with refractory hypertension. The anatomic distribution of renal artery nerves may influence the safety and efficacy profile of this procedure. We aimed to describe the anatomic distribution and density of periarterial renal nerves in the porcine model. Thirty arterial renal sections were included in the analysis by harvesting a tissue block containing the renal arteries and perirenal tissue from each animal. Each artery was divided into 3 segments (proximal, mid, and distal) and assessed for total number, size, and depth of the nerves according to the location. Nerve counts were greatest proximally (45.62% of the total nerves) and decreased gradually distally (mid, 24.58%; distal, 29.79%). The distribution in nerve size was similar across all 3 sections (∼40% of the nerves, 50-100 µm; ∼30%, 0-50 µm; ∼20%, 100-200 µm; and ∼10%, 200-500 µm). In the arterial segments ∼45% of the nerves were located within 2 mm from the arterial wall whereas ∼52% of all nerves were located within 2.5 mm from the arterial wall. Sympathetic efferent fibers outnumbered sensory afferent fibers overwhelmingly, intermixed within the nerve bundle. In the porcine model, renal artery nerves are seen more frequently in the proximal segment of the artery. Nerve size distribution appears to be homogeneous throughout the artery length. Nerve bundles progress closer to the arterial wall in the distal segments of the artery. This anatomic distribution may have implications for the future development of renal denervation therapies.


Assuntos
Ablação por Cateter/métodos , Artéria Renal/inervação , Sus scrofa/anatomia & histologia , Simpatectomia/métodos , Animais , Humanos , Hipertensão/terapia , Rim/inervação , Modelos Anatômicos , Modelos Animais , Modelos Neurológicos , Sistema Nervoso Simpático/anatomia & histologia , Pesquisa Translacional Biomédica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...