Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomedicines ; 12(2)2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38397969

RESUMO

BACKGROUND: The primary approach for treating ischemic wounds is restoring oxygen supply to the ischemic region. While direct angiosomal revascularization is often associated with better post-operative wound healing and limb salvage, its superiority over non-angiosomal revascularization remains controversial. This study aimed to compare intraoperative tissue oxygen saturation changes in ischemic zones following either direct or indirect revascularization in below-the-knee arteries. METHODS: This prospective observational study included patients undergoing direct and indirect below-the-knee endovascular revascularizations. Assignment to the groups was not randomized. Near-infrared spectroscopy was used to monitor rSO2 changes near the ischemic wounds intraoperatively. The changes were compared between the groups. RESULTS: 15 patients (50%) underwent direct angiosomal revascularization, while an equal number of patients underwent indirect revascularization. Overall, a statistically significant increase in regional oxygen saturation was observed after revascularization (p = 0.001). No statistically significant difference was found between the direct and indirect revascularization groups (p = 0.619). CONCLUSIONS: This study revealed a minor difference in the oxygen saturation increase between the angiosomal and non-angiosomal revascularization groups. Such a finding indicates that the clinical significance of angiosomal revascularization is negligible and might be concealed by confounding factors, such as the vessel diameter and outflow impact on the restenosis rate.

2.
PLoS One ; 19(1): e0296780, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38215081

RESUMO

Intracranial pressure measurement is frequently used for diagnosis in neurocritical care but cannot always accurately predict neurological deterioration. Intracranial compliance plays a significant role in maintaining cerebral blood flow, cerebral perfusion pressure, and intracranial pressure. This study's objective was to investigate the feasibility of transferring external pressure into the eye orbit in a large-animal model while maintaining a clinically acceptable pressure gradient between intraorbital and external pressures. The experimental system comprised a specifically designed pressure applicator that can be placed and tightly fastened onto the eye. A pressure chamber made from thin, elastic, non-allergenic film was attached to the lower part of the applicator and placed in contact with the eyelid and surrounding tissues of piglets' eyeballs. External pressure was increased from 0 to 20 mmHg with steps of 1 mmHg, from 20 to 30 mmHg with steps of 2 mmHg, and from 30 to 50 mmHg with steps of 5 mmHg. An invasive pressure sensor was used to measure intraorbital pressure directly. An equation was derived from measured intraorbital and external pressures (intraorbital pressure = 0.82 × external pressure + 3.12) and demonstrated that external pressure can be linearly transferred to orbit tissues with a bias (systematic error) of 3.12 mmHg. This is close to the initial intraorbital pressure within the range of pressures tested. We determined the relationship between intraorbital compliance and externally applied pressure. Our findings indicate that intraorbital compliance can be controlled across a wide range of 1.55 to 0.15 ml/mmHg. We observed that external pressure transfer into the orbit can be achieved while maintaining a clinically acceptable pressure gradient between intraorbital and external pressures.


Assuntos
Olho , Órbita , Animais , Suínos , Projetos Piloto
3.
Libyan J Med ; 12(1): 1384290, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28982295

RESUMO

The aim of the present study was to locate the ophthalmic artery by using the edge of the internal carotid artery (ICA) as the reference depth to perform a reliable non-invasive intracranial pressure measurement via a multi-depth transcranial Doppler device and to then determine the positions and angles of an ultrasonic transducer (UT) on the closed eyelid in the case of located segments. High tension glaucoma (HTG) patients and healthy volunteers (HVs) undergoing non-invasive intracranial pressure measurement were selected for this prospective study. The depth of the edge of the ICA was identified, followed by a selection of the depths of the IOA and EOA segments. The positions and angles of the UT on the closed eyelid were measured. The mean depth of the identified ICA edge for HTG patients was 64.3 mm and was 63.0 mm for HVs (p = 0.21). The mean depth of the selected IOA segment for HTG patients was 59.2 mm and 59.3 mm for HVs (p = 0.91). The mean depth of the selected EOA segment for HTG patients was 48.5 mm and 49.8 mm for HVs (p = 0.14). The difference in the located depths of the segments between groups was not statistically significant. The results showed a significant difference in the measured UT angles in the case of the identified edge of the ICA and selected ophthalmic artery segments (p = 0.0002). We demonstrated that locating the IOA and EOA segments can be achieved using the edge of the ICA as a reference point. ABBREVIATIONS: OA: ophthalmic artery; IOA: intracranial segments of the ophthalmic artery; EOA: extracranial segments of the ophthalmic artery; ICA: internal carotid artery; UT: ultrasonic transducer; HTG: high tension glaucoma; SD: standard deviation; ICP: intracranial pressure; TCD: transcranial Doppler.


Assuntos
Artéria Carótida Interna/diagnóstico por imagem , Glaucoma/fisiopatologia , Pressão Intracraniana , Artéria Oftálmica/diagnóstico por imagem , Adulto , Estudos de Casos e Controles , Técnicas de Diagnóstico Oftalmológico , Feminino , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Ultrassonografia Doppler Transcraniana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...