Heliyon ; 9(10): e21116, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37916082

RESUMO

Purpose: In this study an evaluation of the imaging performance of an electronic portal imaging device (EPID) is presented. The evaluation performed employing the QC-3V image quality phantom. Methods: An EPID system of a 6 MV LINAC, was used to obtain images of a QC-3V EPID phantom. The X-ray source to phantom distance was 100 cm and the field size was 15x15 cm2. The irradiation conditions comprised Dose Rates (DR) of 200, 400 and 600 for a 2 MU-100 MU range. The Contrast Transfer Function (CTF), the Noise Power Spectrum (NPS), the Normalized Noise Power Spectrum (NNPS) and the Contrast-to-Noise Ratio (CNR) were studied. In addition, an alternative factor showing a frequency related output signal-to-noise ratio (SNR), the Signal-to-Noise-Frequency Response (SNFR), has been introduced. SNFR is a comprehensive quality index, easily determined in clinical environment. Results: The CTF curves were found comparable to each other. The lowest values were measured at 2 MU and 200 MU/min. Concerning the NPS and NNPS graphs it was found that the values decrease up to approximately 0.3 lp/mm and demonstrate a white noise shape afterwards. SNFR values were found reducing with spatial frequency. Highest CNR were found between the region 7 and 11 of the phantom. Conclusions: The influence of MU and DR on EPID performance were investigated. Image quality was assessed using the QC-3V phantom. The presented results can lead to image quality amelioration and act supportively to current image quality control routine protocols.

2.
Sensors (Basel) ; 23(4)2023 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-36850937

RESUMO

BACKGROUND: Mammographic digital imaging is based on X-ray sensors with solid image quality characteristics. These primarily include (a) a response curve that yields high contrast and image latitude, (b) a frequency response given by the Modulation Transfer Function (MTF), which enables small detail imaging and (c) the Normalize Noise Power Spectrum (NNPS) that shows the extent of the noise effect on image clarity. METHODS: In this work, a methodological approach is introduced and described for creating digital phantom images based on the measured image quality properties of the sensor. For this purpose, a mathematical phantom, simulating breast tissue and lesions of blood, adipose, muscle, Ca and Ca(50%)-P(50%) was created by considering the corresponding X-ray attenuation coefficients. The simulated irradiation conditions of the phantom used four mammographic spectra assuming exponential attenuation. Published data regarding noise and blur of a commercial RadEye HR CMOS imaging sensor were used as input data for the resulting images. RESULTS: It was found that the Ca and Ca(50%)-P(50%) lesions were visible in all exposure conditions. In addition, the W/Rh spectrum at 28 kVp provided more detailed images than the corresponding Mo/Mo spectrum. CONCLUSIONS: The presented methodology can act complementarily to image quality measurements, leading to initial optimization of the X-ray exposure parameters per clinical condition.


Assuntos
Adiposidade , Mamografia , Imagens de Fantasmas , Músculos , Modelos Teóricos
3.
Med Biol Eng Comput ; 58(10): 2551-2565, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32815028

RESUMO

A method for the theoretical estimation of the MTF of columnar phosphors with a homogeneous part at the end used in X-ray imaging has been developed. This method considers the light transport inside the scintillator through an analytical modelling, the optical photon beams distribution on the scintillator-optical sensor interface, and uses the definition of the PSF and a Gauss fitted LSF to estimate the MTF of an indirect detector. This method was applied to a columnar CsI:Tl scintillator and validated against experimental results found in literature, and a good agreement was observed. It was found that, by increasing the pixel size of the optical detector and the thickness of the scintillator, the MTF decreased as expected. This method may be used in evaluating the performance of the columnar phosphors used in medical imaging, given their physical and geometrical characteristics.Graphical abstract (a) Side view of a part of the scintillator where five crystal columns with homogeneous ends attached to an optical sensor is shown. (b) Propagation of two random optical photon beams emitted from point K with different angles of emission is shown. All the symbols are explained analytically in the text.


Assuntos
Cintilografia/instrumentação , Modelos Teóricos , Fótons , Reprodutibilidade dos Testes , Raios X
4.
Appl Radiat Isot ; 125: 154-162, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28437735

RESUMO

The aim of the present study is to introduce the detective quantum efficiency (DQE) for the image quality assessment of positron emission tomography (PET) scanners. For this purpose, a thin layer chromatography (TLC) plane source was simulated using a previously validated, scanner and source geometry, Monte Carlo (MC) model. The model was developed with the Geant4 application for tomographic emission (GATE) MC package and reconstructed images obtained with the software for tomographic image reconstruction (STIR), with cluster computing. The GE Discovery ST PET scanner was simulated by using a previously validated code. A plane source consisting of a TLC plate, was simulated by a layer of silica gel on aluminum (Al) foil substrate, immersed in 18F-FDG bath solution (1MBq). Image quality was assessed in terms of the modulation transfer function (MTF) and the normalized noise power spectrum (NNPS) in order to obtain the detective quantum efficiency (DQE). MTF curves were estimated from transverse reconstructed images of the plane source, whereas the NNPS data were estimated from the corresponding coronal images. Images were reconstructed by the maximum likelihood estimation ordered subsets maximum a posteriori one step late (MLE)-OS-MAP-OSL algorithm, by using various subsets 1-21) and iterations 1-20). MTF values were found to increase up to the 12th iteration whereas remain almost constant thereafter. However, the range of the increase in the MTF is limited as the number of subsets increases. The noise levels were found to increase with the corresponding increase of both the number of iterations and subsets. The maximum NNPS value (0.517mm2) was observed for the 420 MLEM-equivalent iterations reconstructed image at 0cycles/mm. Finally DQE values were found to increase for spatial frequencies up to 0.038cycles/mm and to decrease thereafter with the corresponding increase in both number of iterations and subsets. The maximum DQE value (0.48 at 0.038cycles/mm) was obtained for the 8 MLEM-equivalent iterations image. The simulated PET evaluation method based on the TLC plane source can be useful in the quality control and in the further development of PET and SPECT scanners though GATE simulations.

5.
Phys Med ; 35: 39-49, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28242138

RESUMO

PURPOSE: An analytical model has been developed for the light propagation in columnar phosphors, based on the optical photon propagation physical and geometrical principles. METHODS: This model accounts for the multiple reflections on the sides of the crystal column, as well as for the infinite forward and backward reflections of the propagated optical photon beams created in the crystal bulk. Additionally it considers the lateral propagated optical photon beams after multiple refractions from the neighbor columns and the optical photon attenuation inside the scintillator. The model was used to predict the Detector Optical Gain (DOG), and the angular distribution, of the columnar CsI:Tl scintillators, used in medical imaging. RESULTS: The model was validated against CsI:Tl optical photon transmission published results and good agreement was observed. It was, also, found that the DOG is affected by the length of the columns, as well as the incident X-ray energy spectrum. The results of the angular distribution are in accordance with the theory that the longer crystal columns have more directional light distribution. CONCLUSIONS: The results of DOG are in accordance with the use of short crystal columns for lower energies (mammography) and the use of long crystal columns for higher energies (general radiology). Angular distribution was found more directive for long crystal columns.


Assuntos
Modelos Teóricos , Fótons , Cintilografia/instrumentação , Algoritmos , Césio , Iodetos , Cintilografia/métodos , Tálio , Raios X
6.
Hell J Nucl Med ; 19(3): 231-240, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27824962

RESUMO

OBJECTIVE: The aim of the present study was to propose a comprehensive method for positron emission tomography (PET) scanners image quality assessment, by simulation of a thin layer chromatography (TLC) flood source with a previously validated Monte Carlo model. METHODS AND MATERIALS: We used the GATE Monte Carlo package (GEANT4 application for tomographic emission) and the reconstructed images were obtained using the software for tomographic image reconstruction (STIR), with cluster computing. The PET scanner used in this simulation study was the General Electric Discovery-ST (USA). The plane source that was used for the image quality assessment was a TLC plate, consisting of an aluminum (Al) foil, coated with a thin layer of silica and immersed in fluorodeoxyglucose (18F-FDG) bath solution (1 MBq). The influence of different scintillating crystals on PET scanner's image quality, in terms of the modulation transfer function (MTF), the normalized noise power spectrum (NNPS) and the detective quantum efficiency (DQE), were also investigated. Modulation transfer function was estimated from transverse slices of the plane source, whereas the NNPS from the corresponding coronal slices. Images were reconstructed by the commonly used 2D filtered back projection (FBP2D), the Kinahan and Rogers FPB3DRP and the maximum likelihood estimation (MLE)-OSMAPOSL algorithms. Images obtained using the OSMAPOSL algorithm were assessed by using 15 subsets and 3 iterations. RESULTS: The PET scanner configuration, equipped with LuAP crystals, exhibited the optimum MTF values in both 2D and 3D FBP image reconstruction, whereas the corresponding configuration with BGO crystals exhibited the optimum MTF values after the iterative algorithm. The scanner equipped with the BGO crystals was also found to exhibit overall the lowest noise levels and the highest DQE values after algorithms. These finding indicate that the GE Discovery ST PET scanner exhibits the optimum image quality parameters, in terms of MTF, NNPS and DQE, with BGO scintillating crystals. CONCLUSION: Our new method showed that the imaging performance of PET scanners can be fully characterized and further improved by investigation of the imaging chain components through Monte Carlo methods. To this aim, a TLC based plane source was used during the simulation, in order to assess the impact of the scintillating crystal material on PET image quality, with the application of a previously validated Monte Carlo model. The aforementioned plane source can be also useful for the further development of PET and SPET scanners through GATE simulations, for clinical applications.


Assuntos
Algoritmos , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Armazenamento e Recuperação da Informação/métodos , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia por Emissão de Pósitrons/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Radiat Prot Dosimetry ; 165(1-4): 382-5, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25911405

RESUMO

During the last decades, radiation protection and dosimetry in medical X-ray imaging practice has been extensively studied. The purpose of this study was to measure secondary radiation in a conventional radiographic room, in terms of ambient dose rate equivalent H*(10) and its dependence on the radiographic exposure parameters such as X-ray tube voltage, tube current and distance. With some exceptions, the results indicated that the scattered radiation was uniform in the space around the water cylindrical phantom. The results also showed that the tube voltage and filtration affect the dose rate due to the scatter radiation. Finally, the scattered X-ray energy distribution was experimentally calculated.


Assuntos
Proteção Radiológica/métodos , Radiometria/métodos , Espalhamento de Radiação , Ar , Algoritmos , Humanos , Imagens de Fantasmas , Lesões por Radiação/prevenção & controle , Software , Água , Raios X
8.
Biomed Res Int ; 2014: 634856, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24895593

RESUMO

OBJECTIVES: In this work, a simple technique to assess the image quality characteristics of the postprocessed image is developed and an easy to use figure of image quality (FIQ) is introduced. This FIQ characterizes images in terms of resolution and noise. In addition information capacity, defined within the context of Shannon's information theory, was used as an overall image quality index. MATERIALS AND METHODS: A digital mammographic image was postprocessed with three digital filters. Resolution and noise were calculated via the Modulation Transfer Function (MTF), the coefficient of variation, and the figure of image quality. In addition, frequency dependent parameters such as the noise power spectrum (NPS) and noise equivalent quanta (NEQ) were estimated and used to assess information capacity. RESULTS: FIQs for the "raw image" data and the image processed with the "sharpen edges" filter were found 907.3 and 1906.1, correspondingly. The information capacity values were 60.86 × 10(3) and 78.96 × 10(3) bits/mm(2). CONCLUSION: It was found that, after the application of the postprocessing techniques (even commercial nondedicated software) on the raw digital mammograms, MTF, NPS, and NEQ are improved for medium to high spatial frequencies leading to resolving smaller structures in the final image.


Assuntos
Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Algoritmos , Humanos , Razão Sinal-Ruído