Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Circulation ; 128(7): 687-93, 2013 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-23868858

RESUMO

BACKGROUND: Atrial-based pacing is associated with lower risk of atrial fibrillation (AF) in sick sinus syndrome compared with ventricular pacing; nevertheless, the impact of site and rate of atrial pacing on progression of AF remains unclear. We evaluated whether long-term atrial pacing at the right atrial (RA) appendage versus the low RA septum with (ON) or without (OFF) a continuous atrial overdrive pacing algorithm can prevent the development of persistent AF. METHODS AND RESULTS: We randomized 385 patients with paroxysmal AF and sick sinus syndrome in whom a pacemaker was indicated to pacing at RA appendage ON (n=98), RA appendage OFF (n=99), RA septum ON (n=92), or RA septum OFF (n=96). The primary outcome was the occurrence of persistent AF (AF documented at least 7 days apart or need for cardioversion). Demographic data were homogeneous across both pacing site (RA appendage/RA septum) and atrial overdrive pacing (ON/OFF). After a mean follow-up of 3.1 years, persistent AF occurred in 99 patients (25.8%; annual rate of persistent AF, 8.3%). Alternative site pacing at the RA septum versus conventional RA appendage (hazard ratio=1.18; 95% confidence interval, 0.79-1.75; P=0.65) or continuous atrial overdrive pacing ON versus OFF (hazard ratio=1.17; 95% confidence interval, 0.79-1.74; P=0.69) did not prevent the development of persistent AF. CONCLUSIONS: In patients with paroxysmal AF and sick sinus syndrome requiring pacemaker implantation, an alternative atrial pacing site at the RA septum or continuous atrial overdrive pacing did not prevent the development of persistent AF. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. UNIQUE IDENTIFIER: NCT00419640.


Assuntos
Fibrilação Atrial/prevenção & controle , Estimulação Cardíaca Artificial/métodos , Síndrome do Nó Sinusal/complicações , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Apêndice Atrial , Fibrilação Atrial/etiologia , Fibrilação Atrial/terapia , Doenças Cardiovasculares/mortalidade , Progressão da Doença , Cardioversão Elétrica , Feminino , Septos Cardíacos , Humanos , Ataque Isquêmico Transitório/etiologia , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Estudos Prospectivos , Síndrome do Nó Sinusal/terapia , Acidente Vascular Cerebral/etiologia , Falha de Tratamento
3.
J Cardiovasc Electrophysiol ; 20(9): 1020-5, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19460078

RESUMO

The Septal Pacing for Atrial Fibrillation Suppression Evaluation (SAFE) study is a single-blinded, parallel randomized designed multicenter study in pacemaker indicated patients with paroxysmal atrial fibrillation (AF). The objective is to evaluate whether the site of atrial pacing--conventional right atrial appendage versus low atrial septal--with or without atrial overdrive pacing will influence the development of persistent AF. The study will provide a definitive answer to whether a different atrial pacing site or the use of AF suppression pacing or both can give incremental antiarrhythmic benefit when one is implanting a device for a patient with a history of paroxysmal AF.


Assuntos
Fibrilação Atrial/mortalidade , Fibrilação Atrial/prevenção & controle , Estimulação Cardíaca Artificial/mortalidade , Estimulação Cardíaca Artificial/métodos , Humanos , Internacionalidade , Estudos Prospectivos , Análise de Sobrevida , Taxa de Sobrevida , Resultado do Tratamento
4.
J Huazhong Univ Sci Technolog Med Sci ; 28(6): 639-44, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19107356

RESUMO

Current permanent right ventricular and right atrial endocardial pacing leads are implanted utilizing a central lumen stylet. Right ventricular apex pacing initiates an abnormal asynchronous electrical activation pattern, which results in asynchronous ventricular contraction and relaxation. When pacing from right atrial appendage, the conduction time between two atria will be prolonged, which results in heterogeneity for both depolarization and repolarization. Six patients with Class I indication for permanent pacing were implanted with either single chamber or dual chamber pacemaker. The SelectSecure 3830 4-French (Fr) lumenless lead and the SelectSite C304 8.5-Fr steerable catheter-sheath (Medtronic Inc., USA) were used. Pre-selected pacing sites included inter-atrial septum and right ventricular outflow tract, which were defined by ECG and fluoroscopic criteria. All the implanting procedures were successful without complication. Testing results (mean atrial pacing threshold: 0.87 V; mean P wave amplitude: 2.28 mV; mean ventricular pacing threshold: 0.53V; mean R wave amplitude: 8.75 mV) were satisfactory. It is concluded that implantation of a 4-Fr lumenless pacing lead by using a streerable catheter-sheath to achieve inter-atrial septum or right ventricular outflow tract pacing is safe and feasible.


Assuntos
Estimulação Cardíaca Artificial/métodos , Eletrodos Implantados , Marca-Passo Artificial , Síndrome do Nó Sinusal/terapia , Idoso , Idoso de 80 Anos ou mais , Segurança de Equipamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Implantação de Prótese/métodos
5.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-260092

RESUMO

Current permanent fight ventricular and fight atrial endocardial pacing leads are implanted utilizing a central lumen stylet. Right ventricular apex pacing initiates an abnormal asyno chronous electrical activation pattern, which results in asynchronous ventricular contraction and re-laxation. When pacing from right atrial appendage, the conduction time between two atria will be prolonged, which results in heterogeneity for both depolarization and repolarization. Six patients with Class Ⅰ indication for permanent pacing were implanted with either single chamber or dual chamber pacemaker. The SelectSecure 3830 4-French (Fr) lumenless lead and the SelectSite C304 8.5-Fr steerable catheter-sheath (Medtronic Inc., USA) were used. Pre-selected pacing sites included inter-atrial septum and right ventricular outflow tract, which were defined by ECG and fluoroscopic criteria. All the implanting procedures were successful without complication. Testing results (mean atrial pacing threshold: 0.87 V; mean P wave amplitude: 2.28 mV; mean ventricular pacing threshold:0.53V; mean R wave amplitude: 8.75 mV) were satisfactory. It is concluded that implantation of a 4-Fr lumenless pacing lead by using a streerable catheter-sheath to achieve inter-atrial septum or right ventricular outflow tract pacing is safe and feasible.

6.
Europace ; 8(11): 1002-10, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17043073

RESUMO

AIMS: Malignant ventricular arrhythmias can arise in a subset of congestive heart failure (CHF) patients after they undergo cardiac resynchronization therapy (CRT), thus counteracting the haemodynamic benefits typically associated with biventricular pacing. This study seeks to assess whether alteration of the ventricular transmural repolarization and conduction due to reversal of the depolarization sequence during epicardial or biventricular pacing facilitate the development of ventricular arrhythmias. METHODS AND RESULTS: ECGs and monophasic action potential (MAP) were recorded during programmed stimulation from right ventricle (RV) endocardium (RV-Endo), left ventricle (LV) epicardium (LV-Epi), or both (biventricular, Bi-V) in 15 individuals without structural heart diseases. In patients with severe CHF and CRT (n=21), ECGs were collected during RV-Endo, LV-Epi, and Bi-V pacing. MAP duration on intracardiac electrogram, the QT, JT, and T(peak)-T(end) intervals on ECGs at different pacing sites were measured and compared. In subjects with or without structural heart disease, compared with RV-Endo pacing, LV-Epi and Bi-V pacing resulted in a longer JT (341.78+/-61.97 ms with LV-Epi, 325.86+/-59.69 ms with Bi-V vs. 286.14+/-38.68 ms with RV-Endo in CHF individuals, P<0.0001) or T(peak)-T(end) interval (121.55+/-19.88 ms with LV-Epi, 117.71+/-42.63 ms with Bi-V vs. 102.28+/-12.62 ms with RV-Endo in normal-heart subjects, P<0.0001; 199.70+/-62.44 ms with LV-Epi, 184.89+/-74.08 ms with Bi-V vs. 146.41+/-31.06 ms with RV-Endo in CHF patients, P<0.0001), in addition to prolonged myocardial repolarization time and delayed endocardial activation. During follow-up, sudden death and arrhythmia storm occurred in two CHF patients after CRT. CONCLUSION: Epicardial and biventricular pacing prolong the time and increase the dispersion of myocardial repolarization and delay the transmural conduction. All of these should be considered as potential arrhythmogenic factors in CHF patients who receive CRT.


Assuntos
Arritmias Cardíacas/etiologia , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Insuficiência Cardíaca/prevenção & controle , Medição de Risco/métodos , Adulto , Idoso , Arritmias Cardíacas/diagnóstico , Ventrículos do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Fatores de Risco , Resultado do Tratamento
7.
Zhonghua Xin Xue Guan Bing Za Zhi ; 34(4): 333-7, 2006 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-16776927

RESUMO

OBJECTIVE: The present study retrospectively evaluated the reliability of detecting atrial tachyarrhythmias (ATA), the efficacy of automatic atrial antitachycardia pacing (ATP) and the performance of atrial preventive pacing (APP) algorithms in an implanted antitachycardia DDDRP pacemaker for patients with sick sinus syndrome and paroxysmal ATA. METHODS: In all 24 patients, a DDDRP pacemaker (Medtronic AT500/AT501) was implanted. APP algorithms were switched on at the implanting physician's discretion. During each pacemaker follow-up, information was saved to disk and the ATA burden between those patients with APP algorithms switched "ON" and "OFF" were compared. Reliability of ATA detection was determined by reviewing the stored electrograms and ATP efficacy was also reviewed. Both the pacemaker memory data and manual EGM retrieval were used for the analysis. RESULTS: Complication-free survival at (17.63 +/- 8.79) months was 100%. In 12 patients APP was not turned "ON" until the latest follow-up, in 6 patients APP was switched "ON" at their first visit after implantation, and in another 6 patients APP was switched "ON" after a median follow-up of 9.29 months. There were 97 367 episodes of ATA detected by the devices, of those with stored atrial electrograms the correct classification of ATA was (76.77 +/- 20.52)%. The percentage of atrial pacing with APP algorithms turned on was (87.95 +/- 20.93)%, which was significantly higher than that in patients with APP "OFF" (50.73 +/- 34.46)% (P < 0.01). ATP efficacy was (50.27 +/- 19.29)%. However, the ATA burden (14.73% vs 16.52%, or 7.52 hours vs 6.58 hours per week, P > 0.05) and the longest duration of single ATA episode (27.27 hours vs 20.75 hours, P > 0.05) were not significantly different between those patients with APP "ON" and "OFF". No proarrhythmic effect or major cardiovascular event was observed. CONCLUSIONS: The antitachycardia DDDRP pacemaker correctly detects and diagnoses about 75% of the ATA episodes, while the ATP therapy successfully terminates atrial tachycardia or flutter in about 50% of attacks. However, there is no difference in ATA burden with the APP algorithms and high incidence of atrial pacing. As a non-curative therapy strategy, this high-cost device may only be used in strictly selected indication patients in addition to other treatments of ATA.


Assuntos
Fibrilação Atrial/terapia , Estimulação Cardíaca Artificial/métodos , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/prevenção & controle , Técnicas Eletrofisiológicas Cardíacas , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
8.
Pacing Clin Electrophysiol ; 28(10): 1098-106, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16221269

RESUMO

BACKGROUND: Benefits of cardiac resynchronization therapy (CRT) are well established. However, less is understood concerning its effects on myocardial repolarization and the potential proarrhythmic risk. METHODS AND RESULTS: Healthy dogs (n = 8) were compared to a long QT interval (LQT) model (n = 8, induced by cesium chloride, CsCl) and a dilated cardiomyopathy with congestive heart failure (DCM-CHF, induced by rapid ventricular pacing, n = 5). Monophasic action potential (MAP) recordings were obtained from the subendocardium, midmyocardium, subepicardium, and the transmural dispersion of repolarization (TDR) was calculated. The QT interval and the interval from the peak to the end of the T wave (T(p-e)) were measured. All these characteristics were compared during left ventricular epicardial (LV-Epi), right ventricular endocardial (RV-Endo), and biventricular (Bi-V) pacing. In healthy dogs, TDR prolonged to 37.54 ms for Bi-V pacing and to 47.16 ms for LV-Epi pacing as compared to 26.75 ms for RV-Endo pacing (P < 0.001), which was parallel to an augmentation in T(p-e) interval (Bi-V pacing, 64.29 ms; LV-Epi pacing, 57.89 ms; RV-Endo pacing, 50.29 ms; P < 0.01). During CsCl exposure, Bi-V and LV-Epi pacing prolonged MAPD, TDR, and T(p-e) interval as compared to RV-Endo pacing. The midmyocardial MAPD (276.30 ms vs 257.35 ms, P < 0.0001) and TDR (33.80 ms vs 27.58 ms, P=0.002) were significantly longer in DCM-CHF dogs than those in healthy dogs. LV-Epi and Bi-V pacing further prolonged the MAPD and TDR in this model. CONCLUSIONS: LV-Epi and Bi-V pacing result in prolongation of ventricular repolarization time, and increase of TDR accounted for a parallel augmentation of the T(p-e) interval, which provides evidence that T(p-e) interval accurately represents TDR. These effects are magnified in the LQT and DCM-CHF canine models in addition to their intrinsic transmural heterogeneity in the intact heart. This mechanism may contribute to the development of malignant ventricular arrhythmias, such as torsades de pointes (TdP) in congestive heart failure (CHF) patients treated with CRT.


Assuntos
Estimulação Cardíaca Artificial , Cardiomiopatia Dilatada/fisiopatologia , Eletrocardiografia , Pericárdio/fisiologia , Função Ventricular Esquerda/fisiologia , Animais , Cães , Eletrofisiologia
10.
Int J Cardiol ; 91(2-3): 255-7, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14559142

RESUMO

We present a patient with Brugada-type ECG abnormalities and recurrent polymorphic ventricular tachycardia (VT). Subsequent investigations confirmed the diagnosis of isolated right ventricular myocardial infarction. The VT resolved after the 1st day and was not inducible subsequently. This case illustrates the importance of a careful study of the ECG to exclude other conditions in a patient with Brugada-type ECG abnormalities.


Assuntos
Bloqueio de Ramo/diagnóstico , Eletrocardiografia , Taquicardia Ventricular/diagnóstico , Adulto , Biomarcadores/sangue , Bloqueio de Ramo/patologia , Bloqueio de Ramo/terapia , Angiografia Coronária , Estenose Coronária/diagnóstico , Estenose Coronária/patologia , Estenose Coronária/terapia , Creatina Quinase/sangue , Creatina Quinase Forma MB , Cardioversão Elétrica , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Humanos , Infarto/diagnóstico , Infarto/patologia , Infarto/terapia , Isoenzimas/sangue , Masculino , Ventriculografia com Radionuclídeos , Volume Sistólico/fisiologia , Taquicardia Ventricular/patologia , Taquicardia Ventricular/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...