1.
Sci Rep ; 14(1): 13494, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38866842

RESUMO

In the realm of radiation therapy, a conspicuous obstacle lies in the dearth of external observation concerning radiation beams aimed at the patient. While real-time monitoring of such beams on the patient's surface during therapy holds promise, the imaging of particle beams has thus far proven to be a formidable task. Here, we show our discovery of polyester fabrics and cloths as auspicious scintillating materials, ideally suited for the visualization of radiation beams upon the patient's surface. The light output of polyester fabrics ranged from 10 to 20% of that observed in plastic scintillators. When exposed to spot scanning proton beams, clear beam spots emerged on the surface of the polyester cloths. The movement of these scanning beams was effectively captured using a CMOS camera in a light-shield-free with lights-off environment. The resulting images provided a means for evaluating spills of the proton beams. The inherent flexibility of polyester fabrics and clothing enhances their appeal for applications in the intricate landscape of radiation therapy, promising a bright future for surface beam imaging endeavors.

2.
Materials (Basel) ; 17(11)2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38894025

RESUMO

Aluminum garnets display exceptional adaptability in incorporating mismatching elements, thereby facilitating the synthesis of novel materials with tailored properties. This study explored Ce3+-doped Tb3Al5-xScxO12 crystals (where x ranges from 0.5 to 3.0), revealing a novel approach to control luminescence and photoconversion through atomic size mismatch engineering. Raman spectroscopy confirmed the coexistence of garnet and perovskite phases, with Sc substitution significantly influencing the garnet lattice and induced A1g mode softening up to Sc concentration x = 2.0. The Sc atoms controlled sub-eutectic inclusion formation, creating efficient light scattering centers and unveiling a compositional threshold for octahedral site saturation. This modulation enabled the control of energy transfer dynamics between Ce3+ and Tb3+ ions, enhancing luminescence and mitigating quenching. The Sc admixing process regulated luminous efficacy (LE), color rendering index (CRI), and correlated color temperature (CCT), with adjustments in CRI from 68 to 84 and CCT from 3545 K to 12,958 K. The Ce3+-doped Tb3Al5-xScxO12 crystal (where x = 2.0) achieved the highest LE of 114.6 lm/W and emitted light at a CCT of 4942 K, similar to daylight white. This approach enables the design and development of functional materials with tailored optical properties applicable to lighting technology, persistent phosphors, scintillators, and storage phosphors.

3.
Phys Med Biol ; 69(5)2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38385258

RESUMO

Objective. Prompt gamma photon, prompt x-ray, and induced positron imaging are possible methods for observing a proton beam's shape from outside the subject. However, since these three types of images have not been measured simultaneously nor compared using the same subject, their advantages and disadvantages remain unknown for imaging beam shapes in therapy. To clarify these points, we developed a triple-imaging-modality system to simultaneously measure prompt gamma photons, prompt x-rays, and induced positrons during proton beam irradiation to a phantom.Approach. The developed triple-imaging-modality system consists of a gamma camera, an x-ray camera, and a dual-head positron emission tomography (PET) system. During 80 MeV proton beam irradiation to a polymethyl methacrylate (PMMA) phantom, imaging of prompt gamma photons was conducted by the developed gamma camera from one side of the phantom. Imaging of prompt x-rays was conducted by the developed x-ray camera from the other side. Induced positrons were measured by the developed dual-head PET system set on the upper and lower sides of the phantom.Main results. With the proposed triple-imaging-modality system, we could simultaneously image the prompt gamma photons and prompt x-rays during proton beam irradiation. Induced positron distributions could be measured after the irradiation by the PET system and the gamma camera. Among these imaging modalities, image quality was the best for the induced positrons measured by PET. The estimated ranges were actually similar to those imaged with prompt gamma photons, prompt x-rays and induced positrons measured by PET.Significance. The developed triple-imaging-modality system made possible to simultaneously measure the three different beam images. The system will contribute to increasing the data available for imaging in therapy and will contribute to better estimating the shapes or ranges of proton beam.


Assuntos
Terapia com Prótons , Prótons , Raios X , Elétrons , Terapia com Prótons/métodos , Tomografia Computadorizada por Raios X , Fótons/uso terapêutico , Raios gama , Imagens de Fantasmas , Método de Monte Carlo
4.
Appl Radiat Isot ; 204: 111084, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38016258

RESUMO

High sensitivity and high resolution is desired in such technologies as neutron radiography. However, the contamination of gamma photons in neutron images decreases the accuracy of neutron radiography. To solve this problem, we developed an event-by-event based neutron imaging system that can selectively detect neutrons. The developed neutron imaging system consists of an Li-ZnS(Ag) scintillator plate optically coupled to a flat panel photomultiplier tube (FP-PMT) with a light guide. Scintillation light emitted from the Li-ZnS(Ag) by the interaction with neutron-induced particles is used to calculate the position based on the center of mass calculations. The spatial resolution of the neutron imaging detector is ∼2.3 mm FWHM, and the sensitivity for 252Cf at 2 cm from the source with 2-cm-thick polystyrene is 20 cps/MBq. Background count fraction from 60Co gamma photons was 0.2 %. For various types of neutron absorption phantoms, high-contrast and high-resolution neutron images are obtained with the developed neutron imaging detector using a252Cf neutron source.

5.
Appl Radiat Isot ; 204: 111143, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38101006

RESUMO

High-resolution and real-time imaging of particle ion trajectories is essential in nuclear medicine and nuclear engineering. One potential method to achieve high-resolution real-time trajectory imaging of particle ions involves utilizing an imaging system that integrates a scintillator plate with a magnifying unit and a cooled electron multiplying charge-coupled device (EM-CCD) camera. However, acquiring an EM-CCD camera might prove challenging due to the discontinuation of CCD sensor manufacturing by vendors. As an alternative imaging approach, a low-noise, high-sensitivity camera utilizing a cooled complementary metal-oxide-semiconductor (CMOS) sensor offers a promising solution for imaging particle ion trajectories. Yet, it remains uncertain whether CMOS-based cameras can perform as effectively as CCD-based cameras in capturing particle ion trajectories. To address these concerns, we conducted a comparative analysis of the imaging performance between a CMOS-based system and an EM-CCD-based system for capturing alpha particle trajectories. The results revealed that both systems could image the trajectories of alpha particle, but the spatial resolution with the CMOS-based camera exceeded that of the EM-CCD-based camera, primarily due to the smaller pixel size of the sensor. While the signal-to-noise ratio (SNR) of the trajectory image from the CMOS-based camera initially lagged behind that from the EM-CCD-based camera, this disparity was mitigated by implementing binning techniques on the CMOS-based camera images. In conclusion, our findings suggest that a cooled CMOS camera could serve as a viable alternative for imaging particle ion trajectories.

6.
Biomed Phys Eng Express ; 9(4)2023 06 30.
Artigo em Inglês | MEDLINE | ID: mdl-37387419

RESUMO

Prompt x-ray imaging is a promising method for observing the beam shape from outside a subject. However, its distribution is different from dose distribution, and thus a comparison with the dose is required. Meanwhile, luminescence imaging of water is a possible method for imaging the dose distribution. Consequently, we performed simultaneous imaging of luminescence and prompt x-rays during irradiation by proton beams to compare the distributions between these two different imaging methods. Optical imaging of water was conducted with spot-scanning proton beams at clinical dose level during irradiation to a fluorescein (FS) water phantom set in a black box. Prompt x-ray imaging was also conducted simultaneously from outside the black box using a developed x-ray camera during proton beam irradiation to the phantom. We measured images of the luminescence of FS water and prompt x-rays for various types of proton beams, including pencil beams, spread-out Bragg peak (SOBP) beams, and clinically used therapy beams. After the imaging, ranges were estimated from FS water and prompt x-rays and compared with those calculated with a treatment planning system (TPS). We could measure the prompt x-ray and FS water images simultaneously for all types of proton beams. The ranges estimated from the FS water and those calculated with the TPS closely matched, within a difference of several mm. Similar range difference was found between the results estimated from prompt x-ray images and those calculated with the TPS. We confirmed that the simultaneous imaging of luminescence and prompt x-rays were possible during irradiation with spot-scanning proton beams at a clinical dose level. This method can be applied to range estimation as well as comparison with the dose for prompt x-ray imaging or other imaging methods used in therapy with various types of proton beams at a clinical dose level.


Assuntos
Luminescência , Prótons , Raios X , Radiografia , Fluoresceína , Água
7.
Phys Med Biol ; 68(11)2023 05 30.
Artigo em Inglês | MEDLINE | ID: mdl-37252715

RESUMO

Objective. Prompt x-ray imaging using a low-energy x-ray camera is a promising method for observing a proton beam's shape from outside the subject. Furthermore, imaging of positrons produced by nuclear reactions with protons is a possible method for observing the beam shape. However, it has not been possible to measure these two types of images with a single imaging system due to the limited imaging capability of existing systems. Imaging of both prompt x-rays and the distribution of positrons may compensate for the shortcomings of each method.Approach. We conducted imaging of the prompt x-ray using a pinhole x-ray camera during irradiation with protons in list mode. Then, after irradiation with protons, imaging of annihilation radiations from the produced positrons was conducted using the same pinhole x-ray camera in list mode. After this imaging, list-mode data were sorted to obtain prompt x-ray images and positron images.Main results. With the proposed procedure, we could measure both prompt x-ray images and induced positron images with a single irradiation by a proton beam. From the prompt x-ray images, ranges and widths of the proton beams could be estimated. The distributions of positrons were slightly wider than those of the prompt x-rays. From the time sequential positron images, we could derive the time activity curves of the produced positrons.Significance. Hybrid imaging of prompt x-rays and induced positrons using a pinhole x-ray camera was achieved. The proposed procedure would be useful for measuring prompt x-ray images during irradiation to estimate the beam structures as well as for measuring the induced positron images after irradiation to estimate the distributions and time activity curves of the induced positrons.


Assuntos
Terapia com Prótons , Prótons , Raios X , Elétrons , Câmaras gama , Terapia com Prótons/métodos , Imagens de Fantasmas , Raios gama , Imagem Multimodal , Método de Monte Carlo
8.
Sci Rep ; 13(1): 4955, 2023 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-37100780

RESUMO

High-resolution imaging of alpha particles is required in the detection of alpha radionuclides in cells or small organs for the development of radio-compounds for targeted alpha-particle therapy or other purposes. We developed an ultrahigh resolution, real time alpha-particle imaging system for observing the trajectories of alpha particles in a scintillator. The developed system is based on a magnifying unit and a cooled electron multiplying charge-coupled device (EM-CCD) camera, combined with a 100-µm-thick Ce-doped Gd3Al2Ga3O12 (GAGG) scintillator plate. Alpha particles from an Am-241 source were irradiated to the GAGG scintillator and imaged with the system. Using our system, we measured the trajectories of the alpha particles having different shapes in real time. In some of these measured trajectories, the line shapes of the alpha particles that flew in the GAGG scintillator were clearly observed. The lateral profiles of the alpha-particle trajectories were imaged with widths of ~ 2 µm. We conclude that the developed imaging system is promising for research on targeted alpha-particle therapy or other alpha particle detections that require high spatial resolution.

9.
Phys Med ; 109: 102592, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37084677

RESUMO

Prompt secondary electron bremsstrahlung X-ray (prompt X-ray) imaging using a low-energy X-ray camera is a promising method for observing a beam shape from outside the subject. However, such imaging has so far been conducted only for pencil beams without a multi-leaf collimator (MLC). The use of spread-out Bragg peak (SOBP) with an MLC may increase the scattered prompt gamma photons and decrease the contrast of the images of prompt X-rays. Consequently, we performed prompt X-ray imaging of SOBP beams formed with an MLC. This imaging was carried out in list mode during irradiation of SOBP beams to a water phantom. An X-ray camera with a 1.5-mm diameter as well as 4-mm-diameter pinhole collimators was used for the imaging. List mode data were sorted to obtain the SOBP beam images as well as energy spectra and time count rate curves. Due to the high background counts from the scattered prompt gamma photons penetrating the tungsten shield of the X-ray camera, the SOBP beam shapes were difficult to observe with a 1.5-mm-diameter pinhole collimator. With the 4-mm-diameter pinhole collimators, images of SOBP beam shapes at clinical dose levels could be obtained with the X-ray camera. The use of a 4-mm-diameter pinhole collimator attached to the X-ray camera is effective for prompt X-ray imaging with high sensitivity and low background counts. This approach makes it possible to image SOBP beams with an MLC when the counts are low and the background levels are high.


Assuntos
Carbono , Raios X , Radiografia , Imagens de Fantasmas , Íons
10.
Phys Med ; 103: 66-73, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36244135

RESUMO

PURPOSE: Although real-time imaging of the high-activity iridium-192 (Ir-192) source position during high-dose-rate (HDR) brachytherapy using a high-energy gamma camera system is a promising approach, the energy window was not optimized for spatial resolution or scatter fraction. METHODS: By using a list-mode data-acquisition system that can acquire energy information of a cerium-doped yttrium aluminum perovskite (YA1O3: YAP(Ce)) gamma camera, we tried to optimize the energy window's setting to improve the spatial resolution and reduce scatter fraction. RESULTS: The spatial resolution was highest for the central energy of the window at ∼300 keV. The scatter fraction was also smallest for the central energy of the window at ∼300 keV, and the scatter fraction was more than 48 % smaller than that for the full energy window. CONCLUSIONS: We clarified that the spatial resolution can be improved and the scatter fraction can be reduced through optimizing the energy window of the YAP(Ce) gamma camera by setting the central energy of the window to ∼300 keV for HDR brachytherapy.


Assuntos
Braquiterapia , Câmaras gama , Radioisótopos de Irídio/uso terapêutico , Imagens de Fantasmas
11.
Med Phys ; 49(12): 7703-7714, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36063027

RESUMO

PURPOSE: Measurement of the dwell time and moving speed of a high-activity iridium-192 (Ir-192) source used for high-dose-rate (HDR) brachytherapy is important for estimating the precise dose delivery to a tumor. For this purpose, we used a cerium-doped yttrium aluminum perovskite (YA1O3 :YAP(Ce)) gamma camera system, combined with a list-mode data acquisition system that can acquire short-time sequential images, and measured the dwell times and moving speeds of the Ir-192 source. METHODS: Gamma photon imaging was conducted using the gamma camera in list mode for the Ir-192 source of HDR brachytherapy with fixed dwell times and positions. The acquired list-mode images were sorted to millisecond-order interval time sequential images to evaluate the dwell time at each position. Time count rate curves were derived to calculate the dwell time at each source position and moving speed of the source. RESULTS: We could measure the millisecond-order time sequential images for the Ir-192 source. The measured times for the preset dwell times of 2 s and 10 s were 1.98 to 2.00 s full width at half maximum (FWHM) and 10.0 s FWHM, respectively. The dwell times at the first dwell position were larger than those at other positions. We also measured the moving speeds of the source after the dwells while moving back to the afterloader and found the speed increased with the distance from the edge of the field of view to the last dwell position. CONCLUSION: We conclude that millisecond-order time sequential imaging of the Ir-192 source is possible by using a gamma camera and is useful for evaluating the dwell times and moving speeds of the Ir-192 source.


Assuntos
Braquiterapia , Dosagem Radioterapêutica , Braquiterapia/métodos , Radioisótopos de Irídio/uso terapêutico , Diagnóstico por Imagem
12.
Sensors (Basel) ; 22(12)2022 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-35746105

RESUMO

We developed a path-planning system for radiation source identification devices using 4π gamma imaging. The estimated source location and activity were calculated by an integrated simulation model by using 4π gamma images at multiple measurement positions. Using these calculated values, a prediction model to estimate the probability of identification at the next measurement position was created by via random forest analysis. The path-planning system based on the prediction model was verified by integrated simulation and experiment for a 137Cs point source. The results showed that 137Cs point sources were identified using the few measurement positions suggested by the path-planning system.


Assuntos
Diagnóstico por Imagem , Planejamento da Radioterapia Assistida por Computador , Radioisótopos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
13.
Biomed Phys Eng Express ; 8(2)2022 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-35180713

RESUMO

Coincidence timing resolution (CTR) is an important parameter in clinical positron emission tomography (PET) scanners to increase the signal-to-noise ratio of PET images by using time-of-flight (TOF) information. Lutetium (Lu) based scintillators are often used for TOF-PET systems. However, the self-radiation of Lu-based scintillators may influence the image quality for ultra-low activity PET imaging. Recently, a gadolinium fine aluminum gallate (Ce:GFAG) scintillation crystal that features a fast decay time (∼55 ns) and no self-radiation was developed. The present study aimed at optimizing the GFAG crystal surface treatment to enhance both CTR and energy resolution (ER). The TOF-PET detector consisted of a GFAG crystal (3.0 × 3.0 × 20 mm3) and a SiPM with an effective area of 3.0 × 3.0 mm2. The timing and energy signals were extracted using a high-frequency SiPM readout circuit and then were digitized using a CAMAC DAQ system. The CTR and ER were evaluated with nine different crystal surface treatments such as partial saw-cut and chemical polishing and the 1-side saw-cut was the best choice among the treatments. The respective CTR and ER of 202 ± 2 ps and 9.5 ± 0.1% were obtained with the 1-side saw-cut; the other 5-side mechanically polished GFAG crystals had respective values which were 18 ps (9.0%) and 1.3% better than those of the all-side mechanically polished GFAG crystal. The chemically polished GFAG crystals also offered enhanced CTR and ER of about 17 ps (8.2%) and 2.1%, respectively, over the mechanically polished GFAG crystals.


Assuntos
Fótons , Tomografia por Emissão de Pósitrons , Alumínio , Lutécio , Tomografia por Emissão de Pósitrons/métodos , Razão Sinal-Ruído
14.
Artigo em Inglês | MEDLINE | ID: mdl-34673486

RESUMO

The effect of the difference in the thickness ratio of the double-layered thickness-shear resonator on the temperature characteristics of the resonance frequency was investigated using a Ca3TaGa3Si2O14 (CTGS) single crystal. Three specimens with thickness ratios of x = 0.25 , 0.33, and 0.50 were prepared using 122° Y - and 171° Y -cut CTGS substrates. For the specimens with x = 0.25 and 0.33, the temperature characteristics varied depending on the order of the resonance mode. For the specimen with x = 0.50 , on the other hand, almost the same temperature characteristics were observed regardless of the order of the resonance mode. To interpret this phenomenon, a new equation for predicting the temperature characteristics of the fundamental mode (first mode) for the double-layered resonator was created using the electric flux density ratio generated in the two substrates. The expected values using this equation were in good agreement with the result of the first mode temperature characteristics.


Assuntos
Vibração , Temperatura
15.
Phys Med Biol ; 66(22)2021 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-34644694

RESUMO

Objective.Time-of-flight (TOF) and depth-of-interaction (DOI) are well recognized as important information to improve PET image quality. Since such information types are not correlated, many TOF-DOI detectors have been developed but there are only a few reports of high-resolution detectors (e.g. 1.5 mm resolution) for brain PET systems. Based on the DOI detector, which enables single-ended readout by optically coupling a pair of crystals and having a loop structure, we have developed the crosshair light sharing (CLS) PET detector that optically couples the four-loop structure, consisting of quadrisected crystals comparable in size to a photo-sensor, to four photo-sensors in close proximity arranged in a windmill shape. Even as a high-resolution detector, the CLS PET detector could obtain both TOF and DOI information. The coincidence resolving time (CRT) of the CLS PET detector needs to be further improved, however, for application to the brain PET system. Recently, a fast LGSO crystal was developed which has advantages in detection efficiency and CRT compared to the GFAG crystal. In this work, we developed the CLS PET detector using the fast LGSO crystal for the TOF-DOI brain PET system.Approach.The crystals were each 1.45 × 1.45 × 15 mm3and all surfaces were chemically etched. The CLS PET detector consisted of a 14 × 14 crystal array optically coupled to an 8 × 8 MPPC array.Main results.The fast LGSO array provided 10.1% energy resolution at 511 keV, 4.7 mm DOI resolution at 662 keV, and 293 ps CRT with the energy window of 440-620 keV.Significance.The developed CLS PET detector has 290% higher coincidence sensitivity, 30% better energy resolution, and 32% better time resolution compared to our previous CLS PET detector.


Assuntos
Encéfalo , Tomografia por Emissão de Pósitrons , Encéfalo/diagnóstico por imagem , Cabeça , Humanos , Tomografia por Emissão de Pósitrons/métodos
16.
Sci Rep ; 11(1): 17933, 2021 09 09.
Artigo em Inglês | MEDLINE | ID: mdl-34504184

RESUMO

Positron-emission tomography (PET) and single-photon-emission computed tomography (SPECT) are well-established nuclear-medicine imaging methods used in modern medical diagnoses. Combining PET with 18F-fluorodeoxyglucose (FDG) and SPECT with an 111In-labelled ligand provides clinicians with information about the aggressiveness and specific types of tumors. However, it is difficult to integrate a SPECT system with a PET system because SPECT requires a collimator. Herein, we describe a novel method that provides simultaneous imaging with PET and SPECT nuclides by combining PET imaging and Compton imaging. The latter is an imaging method that utilizes Compton scattering to visualize gamma rays over a wide range of energies without requiring a collimator. Using Compton imaging with SPECT nuclides, instead of the conventional SPECT imaging method, enables PET imaging and Compton imaging to be performed with one system. In this research, we have demonstrated simultaneous in vivo imaging of a tumor-bearing mouse injected with 18F-FDG and an 111In-antibody by using a prototype Compton-PET hybrid camera. We have succeeded in visualizing accumulations of 18F-FDG and 111In-antibody by performing PET imaging and Compton imaging simultaneously. As simultaneous imaging utilizes the same coordinate axes, it is expected to improve the accuracy of diagnoses.

17.
ACS Omega ; 6(12): 8131-8141, 2021 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-33817472

RESUMO

This study presents the criteria for shape control in the micro-pulling-down (µ-PD) method for low-wettability systems (dewetting µ-PD method), which enables us to achieve highly shape-controllable crystal growth. In the dewetting µ-PD method, the presence of the die wall inhibits the direct observation of the meniscus during the process. Therefore, in this study, the meniscus shape was calculated using the Young-Laplace equation to predict the optimal crystal growth conditions. The free-end and fixed-end boundary conditions to be satisfied for the differential equations were defined at the triple point, with the melt on the die wall. The relationship between the crystal diameter and pressure in the fixed-end condition, wherein the wetting angle (α) at the triple point of the crystal was 90°, indicated the suppression of the melt infiltration by the presence of crystals. The gap between the die and crystal was minimized for the contact angle (θ) and growth angle (αgr) in the fixed-end and free-end conditions, at which |αgr + θ - π| was minimum at a given pressure under the assumption of single-valued solutions. The results of this study will facilitate the formation of noble-metal alloys with a net shape and expand the scope for the development of new materials.

18.
Phys Med Biol ; 66(6): 065013, 2021 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-33607635

RESUMO

The crosshair light-sharing (CLS) PET detector is our original depth-of-interaction (DOI) detector, which is based on a single-ended readout scheme with quadrisected crystals comparable in size to a photo-sensor. In this work, we developed 32 CLS PET detectors, each of which consisted of a multi-pixel photon counter (MPPC) array and gadolinium fine aluminum garnet (GFAG) crystals, and we developed a benchtop prototype of a small animal size PET. Each GFAG crystal was 1.45 × 1.45 × 15 mm3. The MPPC had a surface area of 3.0 × 3.0 mm2. The benchtop prototype had two detector rings of 16 detector blocks. The ring diameter and axial field-of-view were 14.2 cm and 4.9 cm, respectively. The data acquisition system used was the PETsys silicon photomultiplier readout system. The continuous DOI information was binned into three DOI layers by applying a look-up-table to a 2D position histogram. Also, energy and timing information was corrected using DOI information. After the calibration procedure, the energy resolution and the coincidence time resolution were 14.6% and 531 ps, respectively. Imaging test results of a small rod phantom obtained by an iterative reconstruction method showed clear separation of 1.6 mm rods with the help of DOI information.


Assuntos
Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Alumínio , Animais , Calibragem , Desenho de Equipamento , Distribuição Normal , Fótons , Contagem de Cintilação , Software
19.
Appl Radiat Isot ; 168: 109483, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33323313

RESUMO

Since Ce-doped YAlO3 (YAP(Ce)) scintillators have small non-proportionality, it is useful to develop a radiation imaging detector for low-energy gamma photons or X-rays. However, the YAP(Ce) performance with different Ce concentrations remains unclear. Consequently, we measured the basic performance of YAP(Ce) plates with different Ce concentrations. We used three types of YAP(Ce) scintillator plates with different Ce concentrations: 0.05% Ce, 1% Ce, and 2% Ce. The YAP(Ce) plates were 10 mm × 10 mm x 0.5 mm. We measured and compared the energy spectra, the decay times, the α-γ ratio, and the non-proportionality. We also evaluated the relation between these performances and the Ce concentrations. The light output of a YAP(Ce) showed positive correlation with the Ce concentrations, and the decay time of the YAP(Ce) showed a negative correlation with them. The energy resolution slightly improved for a YAP(Ce) with higher Ce concentrations. We found the α-γ ratio were slightly larger for higher Ce concentrations. The YAP(Ce) plate with a 2% Ce had the highest light output and the best energy resolution as well as the shortest decay time. Based on these results, the YAP(Ce) plate with a concentration of 2% Ce is a better selection for the development of radiation detectors or radiation imaging detectors for low-energy gamma photons or X-rays as well as alpha particles.

20.
Med Phys ; 47(11): 5739-5748, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32916769

RESUMO

PURPOSE: Astatine-211 (At-211) is a promising alpha emitter for radionuclide therapy. High-resolution in vivo imaging of At-211 in small animals is needed for the development of At-211 radiopharmaceuticals. For this purpose, we developed a low-energy x-ray camera using a thin YAlO3 :Ce (YAP(Ce)) plate to image the low-energy x rays (73-87 keV) from the daughter radionuclide of At-211 (Po-211). METHOD: We optically coupled a 38 × 38 × 1-mm YAP (Ce) plate to a position-sensitive photomultiplier (PSPMT) to develop an imaging detector. A pinhole or a parallel hole collimator was attached to the imaging detector, and the performance was measured for 60-keV gamma photons. With the developed x-ray camera, we carried out imaging of a mouse that had been administered At-211-NaAt. RESULTS: The intrinsic spatial resolution of the YAP (Ce) x-ray camera was approximately 1.2 mm FWHM, and the energy resolution was 22% FWHM. With a 5-mm-thick parallel hole collimator, the spatial resolution was 3.8 mm FWHM with a sensitivity of 8 × 10-4 at 10 mm, which is a typical distance from the surface of the collimator to a subject in mouse imaging. Using a 1-mm diameter pinhole collimator, the spatial resolution was 1.8 mm FWHM with a sensitivity of 3.5 × 10-4 at 10 mm from the collimator. In the mouse images measured by the developed x-ray camera, we could clearly observe that the At-211 accumulated in the thyroid gland and the stomach of the mouse. CONCLUSION: We concluded that the YAP (Ce) x-ray camera is useful for in vivo imaging of At-211.


Assuntos
Câmaras gama , Animais , Astato , Camundongos , Imagens de Fantasmas , Radiografia , Raios X