Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Hypertens Res ; 47(5): 1362-1371, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38454147

RESUMO

The measurement evolution enabled more accurate evaluation of aldosterone production in hypertensive patients. However, the cut-off values for novel assays have been not sufficiently validated. The present study was undertaken to validate the novel chemiluminescent enzyme immunoassay for aldosterone in conjunction with other methods. Moreover, we also aimed to establish a new cut-off value for primary aldosteronism in the captopril challenge test using the novel assay. First, we collected 390 plasma samples, in which aldosterone levels measured using liquid chromatography-mass spectrometry ranged between 0.18 and 1346 ng/dL. The novel chemiluminescent enzyme immunoassay showed identical correlation of plasma aldosterone with liquid chromatography-mass spectrometry, in contrast to conventional radioimmunoassay. Further, we enrolled 299 and 39 patients with primary aldosteronism and essential hypertension, respectively. Plasma aldosterone concentrations measured using the novel assay were lower than those measured by radioimmunoassay, which resulted in decreased aldosterone-to-renin ratios. Subsequently, positive results of the captopril challenge test based on radioimmunoassay turned into "negative" based on the novel assay in 45% patients with primary aldosteronism, using the conventional cut-off value (aldosterone-to-renin activity ratio > 20 ng/dL per ng/mL/h). Receiver operating characteristic curve analysis demonstrated that aldosterone-to-renin activity ratios > 8.2 ng/dL per ng/mL/h in the novel assay was compatible with the conventional diagnosis (sensitivity, 0.874; specificity, 0.980). Our study indicates the great measurement accuracy of the novel chemiluminescent enzyme immunoassay for aldosterone, and the importance of measurement-adjusted cut-offs in the diagnosis of primary aldosteronism.


Assuntos
Aldosterona , Captopril , Hiperaldosteronismo , Medições Luminescentes , Humanos , Hiperaldosteronismo/diagnóstico , Hiperaldosteronismo/sangue , Masculino , Feminino , Pessoa de Meia-Idade , Aldosterona/sangue , Estudos Retrospectivos , Adulto , Idoso , Medições Luminescentes/métodos , Técnicas Imunoenzimáticas/métodos , Hipertensão/sangue , Hipertensão/diagnóstico , Renina/sangue , Estudos de Coortes , Radioimunoensaio
2.
Front Endocrinol (Lausanne) ; 13: 859347, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35388294

RESUMO

Since April 2021, the plasma aldosterone concentration has been measured by chemiluminescent enzyme immunoassay (CLEIA) in Japan. In the present study, we developed a new CLEIA using a two-step sandwich method to measure the 24-hour urine aldosterone level. We collected 115 urine samples and measured 24-hour urine aldosterone levels employing radioimmunoassay (RIA), CLEIA, and liquid chromatography-tandem mass spectrometry (LC-MS/MS). The results showed that the 24-hour urine aldosterone levels measured using CLEIA and LC-MS/MS were significantly correlated (ρ = 0.992, P < 0.0001). Based on the results of Passing-Bablok regression analysis, the slope was 0.992 and the intercept -19.3. The 24-hour urine aldosterone levels measured using CLEIA and RIA were also significantly correlated (ρ = 0.905, P < 0.0001). However, the aldosterone level measured by CLEIA was lower than that measured by RIA (slope, 0.729; intercept, 120.9). In Japan, a new guideline for primary aldosteronism has been announced, with changes in the aldosterone measurement method. The cutoff values for oral sodium loading test (OSLT) were changed, but clinical verification using real-world urine samples has not been performed. Therefore, we examined the cut-off value of the 24-hour urine aldosterone level after the OSLT. Receiver operating characteristic analysis revealed a cut-off value for primary aldosteronism of 3 µg/day.


Assuntos
Aldosterona , Hiperaldosteronismo , Cromatografia Líquida , Humanos , Técnicas Imunoenzimáticas , Cloreto de Sódio , Espectrometria de Massas em Tandem/métodos
3.
Diagnostics (Basel) ; 11(3)2021 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-33806394

RESUMO

In the present study, we developed a new chemiluminescent enzyme immunoassay (CLEIA) using a two-step sandwich method to measure aldosterone concentrations. We investigated serum and plasma aldosterone concentrations in 75 blood samples from 27 patients using a radioimmunoassay (RIA) and the CLEIA (with current and newly improved reagents) as well as liquid chromatography-tandem mass spectrometry (LC-MS/MS). Based on the results of the Passing-Bablok regression analysis, the aldosterone levels measured using CLEIA with the new reagents and those measured by LC-MS/MS were found to be significantly correlated (slope, 0.984; intercept, 0.2). However, aldosterone levels varied depending on the measurement method (i.e., CLEIA with the new reagent, CLEIA with the current reagent, and RIA). Aldosterone levels were lower with the improved CLEIA method than with RIA and CLEIA using the current reagent. Therefore, the cutoff values of the screening test as well as those of the confirmatory test for primary aldosteronism (PA) should be adjusted to follow current clinical practice guidelines for PA. The formula that can be used to obtain the aldosterone level (pg/mL) when using CLEIA with the new reagent is 0.765 × RIA (pg/mL) - 33.7. This formula will enable PA cutoff values to be set for provisional screening and confirmatory tests.

4.
Cancer Chemother Pharmacol ; 79(4): 783-789, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28314987

RESUMO

PURPOSE: Half-life of SN-38, an active metabolite of irinotecan, remarkably increases in patients with end-stage kidney disease (ESKD), even though SN-38 is excreted in bile. Uremic toxins (UTs), which accumulate in the serum of ESKD patients, were reported to inhibit organic anion-transporting polypeptide (OATP) 1B1-mediated uptake of SN-38; however, the relevance of this finding in a clinical setting is unknown. This study focused on cooperative effects of serum components and UTs on OATP1B1-mediated transport of SN-38. METHODS: Uptake of SN-38 by OATP1B1 was evaluated using cells stably expressing OATP1B1. Serum was obtained from > 400 ESKD patients undergoing hemodialysis. Deproteinized serum was combined with human serum albumin (HSA) to explore the effects of albumin-bound and unbound serum compounds. RESULTS: Uptake clearance of SN-38 in OATP1B1 cells decreased by 40% in the presence of uremic serum residue with albumin compared to that in the presence of normal serum residue. Additional UTs (3-carboxy-4-methyl-5-propyl-2-furanpropionic acid, hippuric acid, indole-3-acetic acid, and 3-indoxyl sulfate) combined with normal serum residue in HSA decreased OATP1B1-mediated SN-38 transport by 32.1% compared to that in the presence of normal serum residue. The inhibitory effect of albumin-unbound fraction with UTs and normal serum residue was comparable to that of uremic serum residue, with an uptake decrease of 17.2% compared to that reported in the presence of normal serum residue. CONCLUSIONS: Hepatic uptake of SN-38 via OATP1B1 decreases in ESKD patients through cooperative inhibitory effects of UTs and serum components.


Assuntos
Antineoplásicos Fitogênicos/metabolismo , Camptotecina/análogos & derivados , Transportador 1 de Ânion Orgânico Específico do Fígado/metabolismo , Toxinas Biológicas/farmacologia , Uremia/metabolismo , Algoritmos , Antineoplásicos Fitogênicos/farmacocinética , Camptotecina/metabolismo , Camptotecina/farmacocinética , Relação Dose-Resposta a Droga , Células HEK293 , Meia-Vida , Humanos , Irinotecano , Falência Renal Crônica/metabolismo , Falência Renal Crônica/terapia , Falência Renal Crônica/urina , Fígado/metabolismo , Transportador 1 de Ânion Orgânico Específico do Fígado/efeitos dos fármacos , Diálise Renal , Albumina Sérica/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...