Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Sci Rep ; 14(1): 6779, 2024 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-38514696

RESUMO

The heterogeneous pathogenesis and treatment response of non-small cell lung cancer (NSCLC) has led clinical treatment decisions to be guided by NSCLC subtypes, with lung adenocarcinoma and lung squamous cell carcinoma being the most common subtypes. While histology-based subtyping remains challenging, NSCLC subtypes were found to be distinct at the transcriptomic level. However, unlike genomic alterations, gene expression is generally not assessed in clinical routine. Since subtyping of NSCLC has remained elusive using mutational data, we aimed at developing a neural network model that simultaneously learns from adenocarcinoma and squamous cell carcinoma samples of other tissue types and is regularized using a neural network model trained from gene expression data. While substructures of the expression-based manifold were captured in the mutation-based manifold, NSCLC classification accuracy did not significantly improve. However, performance was increased when rejecting inconclusive samples using an ensemble-based approach capturing prediction uncertainty. Importantly, SHAP analysis of misclassified samples identified co-occurring mutations indicative of both NSCLC subtypes, questioning the current NSCLC subtype classification to adequately represent inherent mutational heterogeneity. Since our model captures mutational patterns linked to clinical heterogeneity, we anticipate it to be suited as foundational model of genomic data for clinically relevant prognostic or predictive downstream tasks.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Carcinoma de Células Escamosas , Neoplasias Pulmonares , Humanos , Carcinoma Pulmonar de Células não Pequenas/patologia , Neoplasias Pulmonares/patologia , Incerteza , Carcinoma de Células Escamosas/patologia , Mutação
2.
Heliyon ; 10(3): e25410, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38356547

RESUMO

All viruses, including SARS-CoV-2, the virus responsible for COVID-19, continue to evolve, which can lead to new variants. The objective of this study is to assess the agreement between real-world clinical data and an algorithm that utilizes laboratory markers and age to predict the progression of disease severity in COVID-19 patients during the pre-Omicron and Omicron variant periods. The study evaluated the performance of a deep learning (DL) algorithm in predicting disease severity scores for COVID-19 patients using data from the USA, Spain, and Turkey (Ankara City Hospital (ACH) data set). The algorithm was developed and validated using pre-Omicron era data and was tested on both pre-Omicron and Omicron-era data. The predictions were compared to the actual clinical outcomes using a multidisciplinary approach. The concordance index values for all datasets ranged from 0.71 to 0.81. In the ACH cohort, a negative predictive value (NPV) of 0.78 or higher was observed for severe patients in both the pre-Omicron and Omicron eras, which is consistent with the algorithm's performance in the development cohort.

3.
Cancer Imaging ; 23(1): 6, 2023 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-36647150

RESUMO

BACKGROUND: Deep-learning-based computer-aided diagnosis (DL-CAD) systems using MRI for prostate cancer (PCa) detection have demonstrated good performance. Nevertheless, DL-CAD systems are vulnerable to high heterogeneities in DWI, which can interfere with DL-CAD assessments and impair performance. This study aims to compare PCa detection of DL-CAD between zoomed-field-of-view echo-planar DWI (z-DWI) and full-field-of-view DWI (f-DWI) and find the risk factors affecting DL-CAD diagnostic efficiency. METHODS: This retrospective study enrolled 354 consecutive participants who underwent MRI including T2WI, f-DWI, and z-DWI because of clinically suspected PCa. A DL-CAD was used to compare the performance of f-DWI and z-DWI both on a patient level and lesion level. We used the area under the curve (AUC) of receiver operating characteristics analysis and alternative free-response receiver operating characteristics analysis to compare the performances of DL-CAD using f- DWI and z-DWI. The risk factors affecting the DL-CAD were analyzed using logistic regression analyses. P values less than 0.05 were considered statistically significant. RESULTS: DL-CAD with z-DWI had a significantly better overall accuracy than that with f-DWI both on patient level and lesion level (AUCpatient: 0.89 vs. 0.86; AUClesion: 0.86 vs. 0.76; P < .001). The contrast-to-noise ratio (CNR) of lesions in DWI was an independent risk factor of false positives (odds ratio [OR] = 1.12; P < .001). Rectal susceptibility artifacts, lesion diameter, and apparent diffusion coefficients (ADC) were independent risk factors of both false positives (ORrectal susceptibility artifact = 5.46; ORdiameter, = 1.12; ORADC = 0.998; all P < .001) and false negatives (ORrectal susceptibility artifact = 3.31; ORdiameter = 0.82; ORADC = 1.007; all P ≤ .03) of DL-CAD. CONCLUSIONS: Z-DWI has potential to improve the detection performance of a prostate MRI based DL-CAD. TRIAL REGISTRATION: ChiCTR, NO. ChiCTR2100041834 . Registered 7 January 2021.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Masculino , Humanos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/métodos
4.
J Magn Reson Imaging ; 58(4): 1055-1064, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36651358

RESUMO

BACKGROUND: Demand for prostate MRI is increasing, but scan times remain long even in abbreviated biparametric MRIs (bpMRI). Deep learning can be leveraged to accelerate T2-weighted imaging (T2WI). PURPOSE: To compare conventional bpMRIs (CL-bpMRI) with bpMRIs including a deep learning-accelerated T2WI (DL-bpMRI) in diagnosing prostate cancer. STUDY TYPE: Retrospective. POPULATION: Eighty consecutive men, mean age 66 years (47-84) with suspected prostate cancer or prostate cancer on active surveillance who had a prostate MRI from December 28, 2020 to April 28, 2021 were included. Follow-up included prostate biopsy or stability of prostate-specific antigen (PSA) for 1 year. FIELD STRENGTH AND SEQUENCES: A 3 T MRI. Conventional axial and coronal T2 turbo spin echo (CL-T2), 3-fold deep learning-accelerated axial and coronal T2-weighted sequence (DL-T2), diffusion weighted imaging (DWI) with b = 50 sec/mm2 , 1000 sec/mm2 , calculated b = 1500 sec/mm2 . ASSESSMENT: CL-bpMRI and DL-bpMRI including the same conventional diffusion-weighted imaging (DWI) were presented to three radiologists (blinded to acquisition method) and to a deep learning computer-assisted detection algorithm (DL-CAD). The readers evaluated image quality using a 4-point Likert scale (1 = nondiagnostic, 4 = excellent) and graded lesions using Prostate Imaging Reporting and Data System (PI-RADS) v2.1. DL-CAD identified and assigned lesions of PI-RADS 3 or greater. STATISTICAL TESTS: Quality metrics were compared using Wilcoxon signed rank test, and area under the receiver operating characteristic curve (AUC) were compared using Delong's test. SIGNIFICANCE: P = 0.05. RESULTS: Eighty men were included (age: 66 ± 9 years; 17/80 clinically significant prostate cancer). Overall image quality results by the three readers (CL-T2, DL-T2) are reader 1: 3.72 ± 0.53, 3.89 ± 0.39 (P = 0.99); reader 2: 3.33 ± 0.82, 3.31 ± 0.74 (P = 0.49); reader 3: 3.67 ± 0.63, 3.51 ± 0.62. In the patient-based analysis, the reader results of AUC are (CL-bpMRI, DL-bpMRI): reader 1: 0.77, 0.78 (P = 0.98), reader 2: 0.65, 0.66 (P = 0.99), reader 3: 0.57, 0.60 (P = 0.52). Diagnostic statistics from DL-CAD (CL-bpMRI, DL-bpMRI) are sensitivity (0.71, 0.71, P = 1.00), specificity (0.59, 0.44, P = 0.05), positive predictive value (0.23, 0.24, P = 0.25), negative predictive value (0.88, 0.88, P = 0.48). CONCLUSION: Deep learning-accelerated T2-weighted imaging may potentially be used to decrease acquisition time for bpMRI. EVIDENCE LEVEL: 3. TECHNICAL EFFICACY: Stage 2.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Masculino , Humanos , Idoso , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Estudos Retrospectivos
5.
JCO Clin Cancer Inform ; 7: e2200100, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36652661

RESUMO

PURPOSE: We developed a deep neural network that queries the lung computed tomography-derived feature space to identify radiation sensitivity parameters that can predict treatment failures and hence guide the individualization of radiotherapy dose. In this article, we examine the transportability of this model across health systems. METHODS: This multicenter cohort-based registry included 1,120 patients with cancer in the lung treated with stereotactic body radiotherapy. Pretherapy lung computed tomography images from the internal study cohort (n = 849) were input into a multitask deep neural network to generate an image fingerprint score that predicts time to local failure. Deep learning (DL) scores were input into a regression model to derive iGray, an individualized radiation dose estimate that projects a treatment failure probability of < 5% at 24 months. We validated our findings in an external, holdout cohort (n = 271). RESULTS: There were substantive differences in the baseline patient characteristics of the two study populations, permitting an assessment of model transportability. In the external cohort, radiation treatments in patients with high DL scores failed at a significantly higher rate with 3-year cumulative incidences of local failure of 28.5% (95% CI, 19.8 to 37.8) versus 10.2% (95% CI, 5.9 to 16.2; hazard ratio, 3.3 [95% CI, 1.74 to 6.49]; P < .001). A model that included DL score alone predicted treatment failures with a concordance index of 0.68 (95% CI, 0.59 to 0.77), which had a similar performance to a nested model derived from within the internal cohort (0.70 [0.64 to 0.75]). External cohort patients with iGray values that exceeded the delivered doses had proportionately higher rates of local failure (P < .001). CONCLUSION: Our results support the development and implementation of new DL-guided treatment guidance tools in the image-replete and highly standardized discipline of radiation oncology.


Assuntos
Redes Neurais de Computação , Tomografia Computadorizada por Raios X , Humanos , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X/métodos , Falha de Tratamento , Modelos de Riscos Proporcionais
6.
Ultrasonography ; 42(1): 154-164, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36475357

RESUMO

PURPOSE: The aim of this study was to evaluate the accuracy of prostate volume estimates calculated from the ellipsoid formula using the anteroposterior (AP) diameter measured on axial and sagittal images obtained through ultrasonography (US) and magnetic resonance imaging (MRI). METHODS: This retrospective study included 456 patients with transrectal US and MRI from two university hospitals. Two radiologists independently measured the prostate gland diameters on US and MRI: AP diameters on axial and sagittal images, transverse, and longitudinal diameters on midsagittal images. The volume estimates, volumeax and volumesag, were calculated from the ellipsoid formula by using the AP diameter on axial and sagittal images, respectively. The prostate volume extracted from MRI-based whole-gland segmentation was considered the gold standard. The intraclass correlation coefficient (ICC) was used to evaluate the inter-method agreement between volumeax and volumesag, and agreement with the gold standard. The Wilcoxon signedrank test was used to analyze the differences between the volume estimates and the gold standard. RESULTS: The prostate gland volume estimates showed excellent inter-method agreement, and excellent agreement with the gold standard (ICCs >0.9). Compared with the gold standard, the volume estimates were significantly larger on MRI and significantly smaller on US (P<0.001). The volume difference (segmented volume-volume estimate) was greater in patients with larger prostate glands, especially on US. CONCLUSION: Volumeax and volumesag showed excellent inter-method agreement and excellent agreement with the gold standard on both US and MRI. However, prostate volume was overestimated on MRI and underestimated on US.

7.
Eur Radiol ; 33(1): 64-76, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35900376

RESUMO

OBJECTIVES: To evaluate the effect of a deep learning-based computer-aided diagnosis (DL-CAD) system on experienced and less-experienced radiologists in reading prostate mpMRI. METHODS: In this retrospective, multi-reader multi-case study, a consecutive set of 184 patients examined between 01/2018 and 08/2019 were enrolled. Ground truth was combined targeted and 12-core systematic transrectal ultrasound-guided biopsy. Four radiologists, two experienced and two less-experienced, evaluated each case twice, once without (DL-CAD-) and once assisted by DL-CAD (DL-CAD+). ROC analysis, sensitivities, specificities, PPV and NPV were calculated to compare the diagnostic accuracy for the diagnosis of prostate cancer (PCa) between the two groups (DL-CAD- vs. DL-CAD+). Spearman's correlation coefficients were evaluated to assess the relationship between PI-RADS category and Gleason score (GS). Also, the median reading times were compared for the two reading groups. RESULTS: In total, 172 patients were included in the final analysis. With DL-CAD assistance, the overall AUC of the less-experienced radiologists increased significantly from 0.66 to 0.80 (p = 0.001; cutoff ISUP GG ≥ 1) and from 0.68 to 0.80 (p = 0.002; cutoff ISUP GG ≥ 2). Experienced radiologists showed an AUC increase from 0.81 to 0.86 (p = 0.146; cutoff ISUP GG ≥ 1) and from 0.81 to 0.84 (p = 0.433; cutoff ISUP GG ≥ 2). Furthermore, the correlation between PI-RADS category and GS improved significantly in the DL-CAD + group (0.45 vs. 0.57; p = 0.03), while the median reading time was reduced from 157 to 150 s (p = 0.023). CONCLUSIONS: DL-CAD assistance increased the mean detection performance, with the most significant benefit for the less-experienced radiologist; with the help of DL-CAD less-experienced radiologists reached performances comparable to that of experienced radiologists. KEY POINTS: • DL-CAD used as a concurrent reading aid helps radiologists to distinguish between benign and cancerous lesions in prostate MRI. • With the help of DL-CAD, less-experienced radiologists may achieve detection performances comparable to that of experienced radiologists. • DL-CAD assistance increases the correlation between PI-RADS category and cancer grade.


Assuntos
Aprendizado Profundo , Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Próstata/patologia , Imageamento por Ressonância Magnética , Estudos Retrospectivos , Neoplasias da Próstata/patologia , Gradação de Tumores , Biópsia Guiada por Imagem , Radiologistas , Computadores
8.
Med Phys ; 49(11): 7347-7356, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35962958

RESUMO

INTRODUCTION: Deep learning (DL) models that use medical images to predict clinical outcomes are poised for clinical translation. For tumors that reside in organs that move, however, the impact of motion (i.e., degenerated object appearance or blur) on DL model accuracy remains unclear. We examine the impact of tumor motion on an image-based DL framework that predicts local failure risk after lung stereotactic body radiotherapy (SBRT). METHODS: We input pre-therapy free breathing (FB) computed tomography (CT) images from 849 patients treated with lung SBRT into a multitask deep neural network to generate an image fingerprint signature (or DL score) that predicts time-to-event local failure outcomes. The network includes a convolutional neural network encoder for extracting imaging features and building a task-specific fingerprint, a decoder for estimating handcrafted radiomic features, and a task-specific network for generating image signature for radiotherapy outcome prediction. The impact of tumor motion on the DL scores was then examined for a holdout set of 468 images from 39 patients comprising: (1) FB CT, (2) four-dimensional (4D) CT, and (3) maximum-intensity projection (MIP) images. Tumor motion was estimated using a 3D vector of the maximum distance traveled, and its association with DL score variance was assessed by linear regression. FINDINGS: The variance and amplitude in 4D CT image-derived DL scores were associated with tumor motion (R2  = 0.48 and 0.46, respectively). Specifically, DL score variance was deterministic and represented by sinusoidal undulations in phase with the respiratory cycle. DL scores, but not tumor volumes, peaked near end-exhalation. The mean of the scores derived from 4D CT images and the score obtained from FB CT images were highly associated (Pearson r = 0.99). MIP-derived DL scores were significantly higher than 4D- or FB-derived risk scores (p < 0.0001). INTERPRETATION: An image-based DL risk score derived from a series of 4D CT images varies in a deterministic, sinusoidal trajectory in a phase with the respiratory cycle. These results indicate that DL models of tumors in motion can be robust to fluctuations in object appearance due to movement and can guide standardization processes in the clinical translation of DL models for patients with lung cancer.


Assuntos
Aprendizado Profundo , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia
9.
Med Image Anal ; 80: 102514, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35717874

RESUMO

Growing number of methods for attenuation-coefficient map estimation from magnetic resonance (MR) images have recently been proposed because of the increasing interest in MR-guided radiotherapy and the introduction of positron emission tomography (PET) MR hybrid systems. We propose a deep-network ensemble incorporating stochastic-binary-anatomical encoders and imaging-modality variational autoencoders, to disentangle image-latent spaces into a space of modality-invariant anatomical features and spaces of modality attributes. The ensemble integrates modality-modulated decoders to normalize features and image intensities based on imaging modality. Besides promoting disentanglement, the architecture fosters uncooperative learning, offering ability to maintain anatomical structure in a cross-modality reconstruction. Introduction of a modality-invariant structural consistency constraint further enforces faithful embedding of anatomy. To improve training stability and fidelity of synthesized modalities, the ensemble is trained in a relativistic generative adversarial framework incorporating multiscale discriminators. Analyses of priors and network architectures as well as performance validation were performed on computed tomography (CT) and MR pelvis datasets. The proposed method demonstrated robustness against intensity inhomogeneity, improved tissue-class differentiation, and offered synthetic CT in Hounsfield units with intensities consistent and smooth across slices compared to the state-of-the-art approaches, offering median normalized mutual information of 1.28, normalized cross correlation of 0.97, and gradient cross correlation of 0.59 over 324 images.


Assuntos
Aprendizado Profundo , Radioterapia Guiada por Imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X
10.
J Nucl Med ; 63(3): 468-475, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34301782

RESUMO

Attenuation correction remains a challenge in pelvic PET/MRI. In addition to the segmentation/model-based approaches, deep learning methods have shown promise in synthesizing accurate pelvic attenuation maps (µ-maps). However, these methods often misclassify air pockets in the digestive tract, potentially introducing bias in the reconstructed PET images. The aims of this work were to develop deep learning-based methods to automatically segment air pockets and generate pseudo-CT images from CAIPIRINHA-accelerated MR Dixon images. Methods: A convolutional neural network (CNN) was trained to segment air pockets using 3-dimensional CAIPIRINHA-accelerated MR Dixon datasets from 35 subjects and was evaluated against semiautomated segmentations. A separate CNN was trained to synthesize pseudo-CT µ-maps from the Dixon images. Its accuracy was evaluated by comparing the deep learning-, model-, and CT-based µ-maps using data from 30 of the subjects. Finally, the impact of different µ-maps and air pocket segmentation methods on the PET quantification was investigated. Results: Air pockets segmented using the CNN agreed well with semiautomated segmentations, with a mean Dice similarity coefficient of 0.75. The volumetric similarity score between 2 segmentations was 0.85 ± 0.14. The mean absolute relative changes with respect to the CT-based µ-maps were 2.6% and 5.1% in the whole pelvis for the deep learning-based and model-based µ-maps, respectively. The average relative change between PET images reconstructed with deep learning-based and CT-based µ-maps was 2.6%. Conclusion: We developed a deep learning-based method to automatically segment air pockets from CAIPIRINHA-accelerated Dixon images, with accuracy comparable to that of semiautomatic segmentations. The µ-maps synthesized using a deep learning-based method from CAIPIRINHA-accelerated Dixon images were more accurate than those generated with the model-based approach available on integrated PET/MRI scanners.


Assuntos
Aprendizado Profundo , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Pelve/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X
11.
iScience ; 24(12): 103523, 2021 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-34870131

RESUMO

The SARS-CoV-2 virus has caused tremendous healthcare burden worldwide. Our focus was to develop a practical and easy-to-deploy system to predict the severe manifestation of disease in patients with COVID-19 with an aim to assist clinicians in triage and treatment decisions. Our proposed predictive algorithm is a trained artificial intelligence-based network using 8,427 COVID-19 patient records from four healthcare systems. The model provides a severity risk score along with likelihoods of various clinical outcomes, namely ventilator use and mortality. The trained model using patient age and nine laboratory markers has the prediction accuracy with an area under the curve (AUC) of 0.78, 95% CI: 0.77-0.82, and the negative predictive value NPV of 0.86, 95% CI: 0.84-0.88 for the need to use a ventilator and has an accuracy with AUC of 0.85, 95% CI: 0.84-0.86, and the NPV of 0.94, 95% CI: 0.92-0.96 for predicting in-hospital 30-day mortality.

12.
Eur J Radiol ; 142: 109894, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34388625

RESUMO

PURPOSE: To compare the performance of lesion detection and Prostate Imaging-Reporting and Data System (PI-RADS) classification between a deep learning-based algorithm (DLA), clinical reports and radiologists with different levels of experience in prostate MRI. METHODS: This retrospective study included 121 patients who underwent prebiopsy MRI and prostate biopsy. More than five radiologists (Reader groups 1, 2: residents; Readers 3, 4: less-experienced radiologists; Reader 5: expert) independently reviewed biparametric MRI (bpMRI). The DLA results were obtained using bpMRI. The reference standard was based on pathologic reports. The diagnostic performance of the PI-RADS classification of DLA, clinical reports, and radiologists was analyzed using AUROC. Dichotomous analysis (PI-RADS cutoff value ≥ 3 or 4) was performed, and the sensitivities and specificities were compared using McNemar's test. RESULTS: Clinically significant cancer [CSC, Gleason score ≥ 7] was confirmed in 43 patients (35.5%). The AUROC of the DLA (0.828) for diagnosing CSC was significantly higher than that of Reader 1 (AUROC, 0.706; p = 0.011), significantly lower than that of Reader 5 (AUROC, 0.914; p = 0.013), and similar to clinical reports and other readers (p = 0.060-0.661). The sensitivity of DLA (76.7%) was comparable to those of all readers and the clinical reports at a PI-RADS cutoff value ≥ 4. The specificity of the DLA (85.9%) was significantly higher than those of clinical reports and Readers 2-3 and comparable to all others at a PI-RADS cutoff value ≥ 4. CONCLUSIONS: The DLA showed moderate diagnostic performance at a level between those of residents and an expert in detecting and classifying according to PI-RADS. The performance of DLA was similar to that of clinical reports from various radiologists in clinical practice.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Humanos , Imageamento por Ressonância Magnética , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Radiologistas , Estudos Retrospectivos
13.
Invest Radiol ; 56(10): 605-613, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-33787537

RESUMO

OBJECTIVE: The aim of this study was to evaluate the effect of a deep learning based computer-aided diagnosis (DL-CAD) system on radiologists' interpretation accuracy and efficiency in reading biparametric prostate magnetic resonance imaging scans. MATERIALS AND METHODS: We selected 100 consecutive prostate magnetic resonance imaging cases from a publicly available data set (PROSTATEx Challenge) with and without histopathologically confirmed prostate cancer. Seven board-certified radiologists were tasked to read each case twice in 2 reading blocks (with and without the assistance of a DL-CAD), with a separation between the 2 reading sessions of at least 2 weeks. Reading tasks were to localize and classify lesions according to Prostate Imaging Reporting and Data System (PI-RADS) v2.0 and to assign a radiologist's level of suspicion score (scale from 1-5 in 0.5 increments; 1, benign; 5, malignant). Ground truth was established by consensus readings of 3 experienced radiologists. The detection performance (receiver operating characteristic curves), variability (Fleiss κ), and average reading time without DL-CAD assistance were evaluated. RESULTS: The average accuracy of radiologists in terms of area under the curve in detecting clinically significant cases (PI-RADS ≥4) was 0.84 (95% confidence interval [CI], 0.79-0.89), whereas the same using DL-CAD was 0.88 (95% CI, 0.83-0.94) with an improvement of 4.4% (95% CI, 1.1%-7.7%; P = 0.010). Interreader concordance (in terms of Fleiss κ) increased from 0.22 to 0.36 (P = 0.003). Accuracy of radiologists in detecting cases with PI-RADS ≥3 was improved by 2.9% (P = 0.10). The median reading time in the unaided/aided scenario was reduced by 21% from 103 to 81 seconds (P < 0.001). CONCLUSIONS: Using a DL-CAD system increased the diagnostic accuracy in detecting highly suspicious prostate lesions and reduced both the interreader variability and the reading time.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Computadores , Humanos , Imageamento por Ressonância Magnética , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Radiologistas , Estudos Retrospectivos
14.
Diagnostics (Basel) ; 10(11)2020 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-33202680

RESUMO

BACKGROUND: Opportunistic prostate cancer (PCa) screening is a controversial topic. Magnetic resonance imaging (MRI) has proven to detect prostate cancer with a high sensitivity and specificity, leading to the idea to perform an image-guided prostate cancer (PCa) screening; Methods: We evaluated a prospectively enrolled cohort of 49 healthy men participating in a dedicated image-guided PCa screening trial employing a biparametric MRI (bpMRI) protocol consisting of T2-weighted (T2w) and diffusion weighted imaging (DWI) sequences. Datasets were analyzed both by human readers and by a fully automated artificial intelligence (AI) software using deep learning (DL). Agreement between the algorithm and the reports-serving as the ground truth-was compared on a per-case and per-lesion level using metrics of diagnostic accuracy and k statistics; Results: The DL method yielded an 87% sensitivity (33/38) and 50% specificity (5/10) with a k of 0.42. 12/28 (43%) Prostate Imaging Reporting and Data System (PI-RADS) 3, 16/22 (73%) PI-RADS 4, and 5/5 (100%) PI-RADS 5 lesions were detected compared to the ground truth. Targeted biopsy revealed PCa in six participants, all correctly diagnosed by both the human readers and AI. CONCLUSIONS: The results of our study show that in our AI-assisted, image-guided prostate cancer screening the software solution was able to identify highly suspicious lesions and has the potential to effectively guide the targeted-biopsy workflow.

15.
Lancet Digit Health ; 1(3): e136-e147, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31448366

RESUMO

Background: Radiotherapy continues to be delivered uniformly without consideration of individual tumor characteristics. To advance toward more precise treatments in radiotherapy, we queried the lung computed tomography (CT)-derived feature space to identify radiation sensitivity parameters that can predict treatment failure and hence guide the individualization of radiotherapy dose. Methods: We used a cohort-based registry of 849 patients with cancer in the lung treated with high dose radiotherapy using stereotactic body radiotherapy. We input pre-therapy lung CT images into a multi-task deep neural network, Deep Profiler, to generate an image fingerprint that primarily predicts time to event treatment outcomes and secondarily approximates classical radiomic features. We validated our findings in an independent study population (n = 95). Deep Profiler was combined with clinical variables to derive iGray, an individualized dose that estimates treatment failure probability to be <5%. Findings: Radiation treatments in patients with high Deep Profiler scores fail at a significantly higher rate than in those with low scores. The 3-year cumulative incidences of local failure were 20.3% (95% CI: 16.0-24.9) and 5.7% (95% CI: 3.5-8.8), respectively. Deep Profiler independently predicted local failure (hazard ratio 1.65, 95% 1.02-2.66, p = 0.04). Models that included Deep Profiler and clinical variables predicted treatment failures with a concordance index of 0.72 (95% CI: 0.67-0.77), a significant improvement compared to classical radiomics or clinical variables alone (p = <0.001 and <0.001, respectively). Deep Profiler performed well in an external study population (n = 95), accurately predicting treatment failures across diverse clinical settings and CT scanner types (concordance index = 0.77 [95% CI: 0.69-0.92]). iGray had a wide dose range (21.1-277 Gy, BED), suggested dose reductions in 23.3% of patients and can be safely delivered in the majority of cases. Interpretation: Our results indicate that there are image-distinct subpopulations that have differential sensitivity to radiotherapy. The image-based deep learning framework proposed herein is the first opportunity to use medical images to individualize radiotherapy dose.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Aprendizado Profundo , Doses de Radiação , Radiocirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino
16.
Int J Comput Assist Radiol Surg ; 12(9): 1543-1559, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28097603

RESUMO

PURPOSE: We aim at developing a framework for the validation of a subject-specific multi-physics model of liver tumor radiofrequency ablation (RFA). METHODS: The RFA computation becomes subject specific after several levels of personalization: geometrical and biophysical (hemodynamics, heat transfer and an extended cellular necrosis model). We present a comprehensive experimental setup combining multimodal, pre- and postoperative anatomical and functional images, as well as the interventional monitoring of intra-operative signals: the temperature and delivered power. RESULTS: To exploit this dataset, an efficient processing pipeline is introduced, which copes with image noise, variable resolution and anisotropy. The validation study includes twelve ablations from five healthy pig livers: a mean point-to-mesh error between predicted and actual ablation extent of 5.3 ± 3.6 mm is achieved. CONCLUSION: This enables an end-to-end preclinical validation framework that considers the available dataset.


Assuntos
Ablação por Cateter/métodos , Neoplasias Hepáticas/cirurgia , Fígado/cirurgia , Animais , Hemodinâmica , Modelos Animais , Necrose/cirurgia , Suínos
17.
Biomed Res Int ; 2016: 6183218, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27127791

RESUMO

Diagnosis of tumor and definition of tumor borders intraoperatively using fast histopathology is often not sufficiently informative primarily due to tissue architecture alteration during sample preparation step. Confocal laser microscopy (CLE) provides microscopic information of tissue in real-time on cellular and subcellular levels, where tissue characterization is possible. One major challenge is to categorize these images reliably during the surgery as quickly as possible. To address this, we propose an automated tissue differentiation algorithm based on the machine learning concept. During a training phase, a large number of image frames with known tissue types are analyzed and the most discriminant image-based signatures for various tissue types are identified. During the procedure, the algorithm uses the learnt image features to assign a proper tissue type to the acquired image frame. We have verified this method on the example of two types of brain tumors: glioblastoma and meningioma. The algorithm was trained using 117 image sequences containing over 27 thousand images captured from more than 20 patients. We achieved an average cross validation accuracy of better than 83%. We believe this algorithm could be a useful component to an intraoperative pathology system for guiding the resection procedure based on cellular level information.


Assuntos
Neoplasias Encefálicas/patologia , Microscopia Confocal/métodos , Microcirurgia/métodos , Neuroendoscopia/métodos , Cirurgia Assistida por Computador/métodos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Humanos , Interpretação de Imagem Assistida por Computador , Microscopia Intravital/métodos , Aprendizado de Máquina , Reconhecimento Automatizado de Padrão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Am J Cardiol ; 117(1): 29-35, 2016 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-26596195

RESUMO

Invasive fractional flow reserve (FFRinvasive), although gold standard to identify hemodynamically relevant coronary stenoses, is time consuming and potentially associated with complications. We developed and evaluated a new approach to determine lesion-specific FFR on the basis of coronary anatomy as visualized by invasive coronary angiography (FFRangio): 100 coronary lesions (50% to 90% diameter stenosis) in 73 patients (48 men, 25 women; mean age 67 ± 9 years) were studied. On the basis of coronary angiograms acquired at rest from 2 views at angulations at least 30° apart, a PC-based computational fluid dynamics modeling software used personalized boundary conditions determined from 3-dimensional reconstructed angiography, heart rate, and blood pressure to derive FFRangio. The results were compared with FFRinvasive. Interobserver variability was determined in a subset of 25 narrowings. Twenty-nine of 100 coronary lesions were hemodynamically significant (FFRinvasive ≤ 0.80). FFRangio identified these with an accuracy of 90%, sensitivity of 79%, specificity of 94%, positive predictive value of 85%, and negative predictive value of 92%. The area under the receiver operating characteristic curve was 0.93. Correlation between FFRinvasive (mean: 0.84 ± 0.11) and FFRangio (mean: 0.85 ± 0.12) was r = 0.85. Interobserver variability of FFRangio was low, with a correlation of r = 0.88. In conclusion, estimation of coronary FFR with PC-based computational fluid dynamics modeling on the basis of lesion morphology as determined by invasive angiography is possible with high diagnostic accuracy compared to invasive measurements.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Modelos Cardiovasculares , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
19.
PLoS One ; 10(7): e0134869, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26230546

RESUMO

BACKGROUND: Despite modern pharmacotherapy and advanced implantable cardiac devices, overall prognosis and quality of life of HF patients remain poor. This is in part due to insufficient patient stratification and lack of individualized therapy planning, resulting in less effective treatments and a significant number of non-responders. METHODS AND RESULTS: State-of-the-art clinical phenotyping was acquired, including magnetic resonance imaging (MRI) and biomarker assessment. An individualized, multi-scale model of heart function covering cardiac anatomy, electrophysiology, biomechanics and hemodynamics was estimated using a robust framework. The model was computed on n=46 HF patients, showing for the first time that advanced multi-scale models can be fitted consistently on large cohorts. Novel multi-scale parameters derived from the model of all cases were analyzed and compared against clinical parameters, cardiac imaging, lab tests and survival scores to evaluate the explicative power of the model and its potential for better patient stratification. Model validation was pursued by comparing clinical parameters that were not used in the fitting process against model parameters. CONCLUSION: This paper illustrates how advanced multi-scale models can complement cardiovascular imaging and how they could be applied in patient care. Based on obtained results, it becomes conceivable that, after thorough validation, such heart failure models could be applied for patient management and therapy planning in the future, as we illustrate in one patient of our cohort who received CRT-D implantation.


Assuntos
Insuficiência Cardíaca/terapia , Medicina de Precisão , Insuficiência Cardíaca/patologia , Insuficiência Cardíaca/fisiopatologia , Humanos
20.
BMC Med Inform Decis Mak ; 15: 9, 2015 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-25889930

RESUMO

BACKGROUND: Percutaneous coronary intervention (PCI) is the most commonly performed treatment for coronary atherosclerosis. It is associated with a higher incidence of repeat revascularization procedures compared to coronary artery bypass grafting surgery. Recent results indicate that PCI is only cost-effective for a subset of patients. Estimating risks of treatment options would be an effort toward personalized treatment strategy for coronary atherosclerosis. METHODS: In this paper, we propose to model clinical knowledge about the treatment of coronary atherosclerosis to identify patient-subgroup-specific classifiers to predict the risk of adverse events of different treatment options. We constructed one model for each patient subgroup to account for subgroup-specific interpretation and availability of features and hierarchically aggregated these models to cover the entire data. In addition, we deviated from the current clinical workflow only for patients with high probability of benefiting from an alternative treatment, as suggested by this model. Consequently, we devised a two-stage test with optimized negative and positive predictive values as the main indicators of performance. Our analysis was based on 2,377 patients that underwent PCI. Performance was compared with a conventional classification model and the existing clinical practice by estimating effectiveness, safety, and costs for different endpoints (6 month angiographic restenosis, 12 and 36 month hazardous events). RESULTS: Compared to the current clinical practice, the proposed method achieved an estimated reduction in adverse effects by 25.0% (95% CI, 17.8 to 30.2) for hazardous events at 36 months and 31.2% (95% CI, 25.4 to 39.0) for hazardous events at 12 months. Estimated total savings per patient amounted to $693 and $794 at 12 and 36 months, respectively. The proposed subgroup-specific method outperformed conventional population wide regression: The median area under the receiver operating characteristic curve increased from 0.57 to 0.61 for prediction of angiographic restenosis and from 0.76 to 0.85 for prediction of hazardous events. CONCLUSIONS: The results of this study demonstrated the efficacy of deployment of bare-metal stents and coronary artery bypass grafting surgery for subsets of patients. This is one effort towards development of personalized treatment strategies for patients with coronary atherosclerosis that could significantly impact associated treatment costs.


Assuntos
Aterosclerose/terapia , Tomada de Decisão Clínica/métodos , Doença da Artéria Coronariana/terapia , Sistemas de Apoio a Decisões Clínicas , Complicações Pós-Operatórias/prevenção & controle , Idoso , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/economia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/economia , Stents/efeitos adversos , Stents/economia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...