Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JACC Cardiovasc Imaging ; 4(4): 366-74, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21492811

RESUMO

OBJECTIVES: This study sought to analyze the effectiveness of cardiac resynchronization therapy (CRT) related to the viability in the segment of left ventricular (LV) lead position defined by myocardial deformation imaging. BACKGROUND: Echocardiographic myocardial deformation analysis allows determination of LV lead position as well as extent of myocardial viability. METHODS: Myocardial deformation imaging based on tracking of acoustic markers within 2-dimensional echo images (GE Ultrasound, GE Healthcare, Horton, Norway) was performed in 65 heart failure patients (54 ± 6 years of age, 41 men) before and 12 months after CRT implantation. In a 16-segment model, the LV lead position was defined based on the segmental strain curve with earliest peak strain, whereas the CRT system was programmed to pure LV pacing. Nonviability of a segment (transmural scar formation) was assumed if the peak systolic circumferential strain was >-11.1%. RESULTS: In 47 patients, the LV lead was placed in a viable segment, and in 18 patients, it was placed in a nonviable segment. At 12-month follow-up there was greater decrease of LV end-diastolic volumes (58 ± 13 ml vs. 44 ± 12 ml, p = 0.0388) and greater increase of LV ejection fraction (11 ± 4% vs. 5 ± 4%, p = 0.0343) and peak oxygen consumption (2.5 ± 0.9 ml/kg/min vs. 1.7 ± 1.1 ml/kg/min, p = 0.0465) in the viable compared with the nonviable group. The change in LV ejection fraction and the reduction in LV end-diastolic volumes at follow-up correlated to an increasing peak systolic circumferential strain in the segment of the LV pacing lead (r = 0.61, p = 0.0274 and r = 0.64, p = 0.0412, respectively). Considering only patients with ischemic heart disease, differences between viable and nonviable LV lead position group were even greater. CONCLUSIONS: Preserved viability in the segment of the CRT LV lead position results in greater LV reverse remodeling and functional benefit at 12-month follow-up. Deformation imaging allows analysis of viability in the LV lead segment.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Ventrículos do Coração/fisiopatologia , Miocárdio/patologia , Função Ventricular Esquerda , Cardiomiopatias/etiologia , Cardiomiopatias/fisiopatologia , Ecocardiografia Doppler , Desenho de Equipamento , Feminino , Alemanha , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Isquemia Miocárdica/complicações , Isquemia Miocárdica/fisiopatologia , Consumo de Oxigênio , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Volume Sistólico , Fatores de Tempo , Sobrevivência de Tecidos , Resultado do Tratamento , Remodelação Ventricular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...