Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Microsc ; 279(3): 234-241, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32043578

RESUMO

Metallic materials are known to be very sensitive to Gallium (Ga) focused ion beam (FIB) processing. Crystal defects formed by FIB irradiation degrade the transmission electron microscope image quality, and it is difficult to distinguish original defects from FIB process-induced damage. A solution to this problem is the low acceleration voltage and low incident angle (LVLA) Argon ion milling, which can be incorporated as an extensional countermeasure for FIB damage removal and eventually for preparation of high-quality lamellae. The transmission electron microscope image quality of iron single crystal could be improved by removing crystal defects using the low acceleration voltage and low incident angle Argon ion milling finish. Lamella quality of the processing result was almost similar with that of the conventional electrolytic polishing. As a practical application of the process, low damage lamella of stainless cast steel could be prepared. Effectiveness of the FIB system equipped with the low acceleration voltage and low incident angle Argon ion milling function as a tool to make high-quality metallic material lamellae is illustrated.

2.
J Perinatol ; 32(3): 170-5, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21852770

RESUMO

OBJECTIVE: The goal of the study was to determine risk factors for maternal cardiac failure in pregnancy complicated with dilated cardiomyopathy (DCM). STUDY DESIGN: The subjects were 29 patients diagnosed with DCM before conception or during the first 7 months of pregnancy. DCM was defined as left ventricle end-diastolic dimension (LVDd)≥48 mm and/or fractional shortening (%FS)≤30% on echocardiography. Patients were followed until at least 1 year after delivery and were categorized into a poor prognosis group (n=6; death or end stage heart failure of New York Heart Association (NYHA) class III and IV) and a good prognosis group (n=23; all other cases). RESULT: DCM was initially diagnosed during pregnancy in 6/6 and 8/23 patients in the poor and good prognosis groups, respectively (P<0.005). The %FS of the first test during pregnancy was 17.5±6.2 and 27.4±9.3% in the respective groups (P<0.005). In eight abortion cases with %FS 15.2±3.1%, %FS, cardiac function and NYHA class were maintained until 20 months after abortion. There was no relationship between LVDd and maternal outcome. CONCLUSION: Onset during pregnancy and decreased %FS are risk factors for a poor maternal outcome in patients with DCM. Abortion prevents further deterioration of cardiac function in patients with a very low %FS.


Assuntos
Cardiomiopatia Dilatada/complicações , Insuficiência Cardíaca/etiologia , Ventrículos do Coração/fisiopatologia , Complicações Cardiovasculares na Gravidez , Disfunção Ventricular Esquerda/etiologia , Adulto , Cardiomiopatia Dilatada/diagnóstico por imagem , Ecocardiografia , Feminino , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Gravidez , Complicações Cardiovasculares na Gravidez/diagnóstico por imagem , Prognóstico , Fatores de Risco , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto Jovem
3.
Heart ; 94(10): 1302-6, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18198205

RESUMO

OBJECTIVE: To evaluate regional and global left ventricular (LV) function and LV wall thickness (LVWT) in patients with hypertrophic cardiomyopathy (HCM). DESIGN AND SETTING: Observational study at the National Cardiovascular Centre and Nagoya University Hospital in Japan. PARTICIPANTS: Thirty-six patients with HCM and 16 patients with hypertensive LV hypertrophy (LVH). MAIN OUTCOME MEASURES: Conventional echocardiography and strain rate (SR) imaging derived from tissue Doppler imaging were performed. Systolic strain (epsilon(sys)), peak systolic SR (SR(sys)), peak early diastolic SR (SR(dia)) and LVWT were obtained from eight LV segments. LV pressure was simultaneously recorded with a high-fidelity micromanometer. RESULTS: The regional epsilon(sys) and SR(sys) were correlated with LVWT in patients with HCM (r = 0.50, p<0.001 and r = 0.63, p<0.001, respectively) but not in patients with hypertensive LVH. The standard deviations of LVWT, epsilon(sys) and SR(sys) obtained from the eight LV segments of each subject were greater for patients with HCM than for patients with hypertensive LVH. The standard deviation of LVWT was correlated with those of epsilon(sys) and SR(sys) (r = 0.55, p<0.001 and r = 0.56, p<0.001, respectively). The standard deviations of LVWT, epsilon(sys) and SR(sys) were correlated with tau (r = 0.35, p<0.05; r = 0.47, p<0.001; and r = 0.39, p<0.005, respectively). CONCLUSIONS: Heterogeneity of regional LV systolic function detected by SR imaging is in part attributable to heterogeneity of LVH and may be linked to impaired global LV relaxation in HCM.


Assuntos
Cardiomiopatia Hipertrófica/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Ecocardiografia Doppler , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sístole , Disfunção Ventricular Esquerda/diagnóstico por imagem
4.
J Am Optom Assoc ; 57(3): 182-4, 1986 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-3457081

RESUMO

The use of oxygen permeable hard contact lenses (Menicon EX) as a cosmetic extended wear lens was investigated in 44 patients (86 eyes). Extended wear of these lenses for a one year period was successfully accomplished by 31 patients (60 eyes). Visual acuity and wearing comfort were good, and severe complications such as corneal edema and ocular infection were not observed through the test period. In some patients with relatively high-grade astigmatism, the degree of corneal astigmatism showed a considerable reduction.


Assuntos
Lentes de Contato de Uso Prolongado/normas , Lentes de Contato Hidrofílicas/normas , Adolescente , Adulto , Segmento Anterior do Olho/patologia , Lentes de Contato de Uso Prolongado/efeitos adversos , Córnea/patologia , Córnea/fisiopatologia , Feminino , Seguimentos , Humanos , Cristalino/metabolismo , Masculino , Oxigênio , Permeabilidade , Transtornos da Visão/fisiopatologia , Transtornos da Visão/terapia , Acuidade Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...