Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 143
Filtrar
1.
J Refract Surg ; 40(6): e420-e434, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38848055

RESUMO

PURPOSE: To discuss factors influencing corneal aberrations that might influence the optical quality after intraocular lens (IOL) implantation. METHODS: PubMed and Scopus were the main resources used to search the medical literature. An extensive search was performed to identify relevant articles concerning factors influencing the level of corneal aberrations as of August 27, 2023. The following keywords were used in various combinations: corneal, aberrations, defocus, astigmatism, spherical aberration, coma, trefoil, quadrafoil, intraocular lens, and IOL. RESULTS: Conclusive evidence is lacking regarding the correlation between age and changes in corneal aberrations. Patients with astigmatism have greater corneal higher-order aberrations than those with minimal astigmatism, particularly concerning trefoil and coma. Increased levels of corneal higher-order aberrations are noted following contact lens wear, in patients with dry eye disease, and with pterygium. Increased higher-order aberrations have been reported following corneal refractive surgery and for 3 months following trabeculectomy; regarding intraocular lens surgery, the results remain controversial. CONCLUSIONS: Several factors influence the level of corneal higher-order aberrations. Multifocal and extended depth-of-focus IOLs can share similarities in their optical properties, and the main difference arises in their design and performance with respect to spherical aberration. Preoperative evaluation is critical for proper IOL choice, particularly in corneas with risk of high levels of aberrations. [J Refract Surg. 2024;40(6):e420-e434.].


Assuntos
Aberrações de Frente de Onda da Córnea , Implante de Lente Intraocular , Refração Ocular , Acuidade Visual , Humanos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/etiologia , Fatores de Risco , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Lentes Intraoculares Multifocais , Percepção de Profundidade/fisiologia , Topografia da Córnea , Córnea/fisiopatologia
3.
Am J Ophthalmol ; 266: 135-143, 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38692502

RESUMO

PURPOSE: To assess the effect of blue-light filtering (BLF) intraocular lenses (IOLs) on the development and progression of macular atrophy (MA) in eyes with neovascular age-related macular degeneration (nAMD). DESIGN: Retrospective, clinical cohort study. METHODS: The study included patients with nAMD with anti-vascular endothelial growth factor (VEGF) injections who underwent uneventful cataract surgery between 2007 and 2018 with follow-up until June 2023. Subsequent MA rates were compared between subjects who received a BLF IOL or a non-BLF IOL. All optical coherence tomography scans were manually reviewed in a masked manner regarding patient baseline variables and IOL status by an experienced research technician. By using Heidelberg software, the area of MA was manually evaluated and calculated (mm2) by the program. The overall risk of developing new-onset MA and the effect of IOL type on disease progression were assessed. Death was included as a censoring event. RESULTS: Included were 373 eyes of 373 patients (mean age, 78.6 ± 6.7 years at surgery; 67.4% were female). BLF IOLs were implanted in 206 eyes, and non-BLF IOLs were implanted in 167 eyes with comparable follow-up times (3164 ± 1420 days vs 3180 ± 1403 days, respectively, P = .908) and other baseline parameters (age, gender, corrected distance visual acuity, macular thickness, cumulative number of anti-VEGF injections). Nine preexisting and 77 new-onset MA cases were detected, with similar distribution between BLF and non-BLF eyes (P = .598 and P = .399, respectively). Both univariate Kaplan-Meier (P = .366) and multivariate Cox regression analyses adjusted for age and gender showed that BLF-IOLs were comparable to non-BLF IOLs regarding hazard for new-onset MA (hazard ratio [HR], 1.236; 95% CI, 0.784-1.949; P = .363). Final MA area at the last visit was 5.14 ± 4.71 mm2 for BLF IOLs and 8.56 ± 9.17 mm2 for non-BLF IOLs (P = .028), with the mean annual MA area increase of 0.78 ± 0.84 mm2 and 1.26 ± 1.32 mm2, respectively (P = .042). CONCLUSIONS: BLF IOLs did not show added benefit over non-BLF IOLs in terms of MA-free survival but were associated with less progression over time in a cohort of patients with nAMD.

4.
Int Ophthalmol ; 44(1): 193, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38653918

RESUMO

PURPOSE: This study evaluated the tear film stability in patients with symptoms of dry eye after installation of dual polymer hydroxypropyl guar/sodium hyaluronate (DPHG/SH) vs single polymer SH. METHODS: Patients with recently diagnosed mild to moderate dry eye disease (OSDI score 23-32 points) were included. For each patient, the right eye was randomized to receive DPHG/SH or 0.15% SH. Just after the administration of the drop to the right eye, the fellow eye received the other eye drop. The first non-invasive Keratograph first break-up time (NIKBUT), average NIKBUT and tear meniscus height (TMH) were measured before administration of the eye drops, at 1-min, 15 min, 30 min, 60 min, 90 min, and 120 min after instillation. RESULTS: A total of 29 patients aged 22.8 ± 2.2 years participated in the study (21 women). No differences between the eye receiving DPHG/SH and single polymer SH were observed for the first NIKBUT (p = 0.45) and average NIKBUT (p = 0.24) variables at any time point. Both DPHG/SH and single polymer SH increased the TMH (p of time effect < 0.001), but with no difference between groups (p = 0.95). CONCLUSION: Both DPHG/SH and single polymer SH solutions provide lubrication of the eye surface, however, with no difference in NIKBUT and TMH evaluations for up to two hours following administration.


Assuntos
Síndromes do Olho Seco , Ácido Hialurônico , Soluções Oftálmicas , Lágrimas , Humanos , Síndromes do Olho Seco/tratamento farmacológico , Síndromes do Olho Seco/diagnóstico , Feminino , Ácido Hialurônico/administração & dosagem , Masculino , Soluções Oftálmicas/administração & dosagem , Adulto Jovem , Adulto , Polissacarídeos/administração & dosagem , Polímeros , Viscossuplementos/administração & dosagem , Estudos Prospectivos
5.
Int Ophthalmol ; 44(1): 185, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38634955

RESUMO

PURPOSE: The aim of the study was to analyze the time-savings associated with introduction of Streamlight™ (Alcon Laboratories, Fort Worth, TX, USA) transepithelial photorefractive keratectomy (PRK) in surface corneal ablations. METHODS: All refractive surgeries were performed using the Alcon WaveLight® EX500 at the ArtLife Clinic, Gdansk, Poland. The study included patients treated for refractive errors with transepithelial PRK between April 2019 and October 2021, who were matched with patients treated with alcohol-assisted PRK during the same period. Only results for the left eye were analyzed. RESULTS: One-hundred-five patients underwent transepithelial PRK (age 33.42 ± 8.67 years) and were matched with 105 patients that underwent alcohol-assisted PRK (age 33.05 ± 10.16 years; p = 0.11). The mean preoperative spherical equivalent refraction was - 2.04 ± 2.28 D, and - 1.9 ± 1.71 D for the transepithelial and alcohol-assisted PRK group, respectively (p = 0.20). The total surgery time was non-significantly shorter in transepithelial PRK (349.46 ± 47.83 s) than in alcohol-assisted PRK (354.93 ± 137.63 s; p = 0.7); however, the variance of surgical time was significantly lower in transepithelial PRK (p < 0.001). The laser treatment duration was greater in transepithelial PRK (41.78 ± 17.2 s) than in alcohol-assisted PRK (8.48 ± 6.12 s; p < 0.001), and so was the number of breaks during the laser treatment (0.95 ± 0.63 vs. 0.53 ± 0.88, respectively; p < 0.001). CONCLUSION: The introduction of transepithelial PRK did not bring significant time-associated savings into the refractive surgery suite.


Assuntos
Oftalmologia , Ceratectomia Fotorrefrativa , Erros de Refração , Procedimentos Cirúrgicos Refrativos , Humanos , Adulto Jovem , Adulto , Olho , Etanol
6.
BMC Ophthalmol ; 24(1): 130, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38528448

RESUMO

INTRODUCTION: Photoscreeners have been shown to provide excellent measurements of the refractive error. However, whether they could be used for assessing cycloplegic refraction has not been examied. This study aimed to evaluate the agreement between cycloplegic and non-cycloplegic measurements obtained using a photoscreener and stationary autorefractor, respectively. METHODS: This study included all patients undergoing routine ophthalmic examination at the Hygeia Clinic (Poland) from June to July 2022. Each patient underwent non-cycloplegic and cycloplegic refraction assessments using the 2WIN photoscreener (Adaptica SRL, Padova, Italy) and an ARK-1 stationary autorefractor ARK-1 (Nidek Co Ltd., Tokyo, Japan), respectively. Each pair of assessments was conducted in random order, and all values were determined at a vertical distance of 12 mm. The agreement between cycloplegic and non-cycloplegic measurements was assessed using paired t-tests, Bland-Altman and ABCD ellipsoids. RESULTS: This analysis included 82 patients, of which 52 were female. Their mean age was 34.39 ± 13.13 years. The non-cycloplegic spherical equivalent (SE) did not differ significantly between the 2WIN (- 1.22 ± 2.45) and ARK-1 (- 1.19 ± 2.96) devices (p = 0.580). However, the cycloplegic SE values demonstrated more negative values with the 2WIN device (- 1.13 ± 2.19) than with the ARK-1 device (- 0.75 ± 3.03; p = 0.007). The non-cycloplegic and cycloplegic measurements were strongly correlated between the devices (r = 0.9473 and 0.9411, respectively). However, the correlation between their cycloplegic shifts in SE was low (r = 0.2645). Ellipsoid refraction aligned better non-cycloplegic (ARK-1 = 1.00; 2WIN = 1.74) than with cycloplegic refraction (ARK-1 = 1.43; 2WIN = 1.90). CONCLUSION: While the cycloplegic measurements obtained with the 2WIN photoscreener were strongly correlated with those obtained with the ARK-1 stationary autorefractor for most of the analyzed parameters, they should not be considered interchangeable.


Assuntos
Midriáticos , Erros de Refração , Humanos , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Masculino , Testes Visuais , Refração Ocular , Erros de Refração/diagnóstico , Japão
7.
Eye Contact Lens ; 50(3): 138-144, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38181218

RESUMO

OBJECTIVE: To compare the outcomes of corneal tomography obtained with an anterior-to-posterior segment optical coherence tomography device (Revo, Optopol Technologies Sp. z o.o.) and a rotating Scheimpflug camera (Pentacam AXL, Oculus Optikgeräte, Wetzlar, Germany). METHODS: In healthy subjects, agreement in stereometric parameters commonly used in cataract and refractive surgery was assessed. Comparison between the devices was performed using correlation coefficients, the Bland-Altman method, and a paired t test. RESULTS: Results of right eyes of 78 patients (47 women) aged 25.24±5.56 years were analyzed. The flat and steep anterior keratometry values were significantly higher for Revo than Pentacam (43.65±1.58 D vs. 42.99±1.47 D; P = 0.000, and 44.53±1.57 D vs. 43.82±1.49 D; P =0.000, respectively) and showed excellent correlation ( r =0.978 and 0.974, respectively). The results for maximal keratometry manifested a higher difference (45.89±1.69 D vs. 44.27±1.51 D for Revo and Pentacam, P =0.000) but were also strongly correlated ( r =0.871). Revo showed significantly lower corneal thickness values than Pentacam, both for apex pachymetry (535.54±32.45 vs. 550.74±31.55 µm; P =0.000) and for thinnest pachymetry (522.58±32.16 vs. 547.25±31.95 µm; P =0.000). The correlation coefficients for anterior and posterior corneal elevation at the thinnest point showed weak positive correlation ( r =0.179 and 0.185), while the correlation for corneal asphericity was moderate ( r =0.317). CONCLUSIONS: There was a significant difference between keratometric values obtained with Revo and the Pentacam AXL, although the measurements showed excellent correlation. Similar results were found for corneal thickness measurements, but not for corneal surface elevation and corneal asphericity.


Assuntos
Córnea , Tomografia de Coerência Óptica , Humanos , Feminino , Tomografia de Coerência Óptica/métodos , Reprodutibilidade dos Testes , Estudos Prospectivos , Córnea/diagnóstico por imagem , Paquimetria Corneana , Topografia da Córnea/métodos
8.
Graefes Arch Clin Exp Ophthalmol ; 262(3): 995-996, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37548670

RESUMO

Pupil diameter is a key parameter for corneal and multifocal intraocular lens surgery. Many devices are dedicated to measure the pupil size, but do not specify the illumination during capture. The aim of this study was to present illumination levels in routinely used ophthalmic devices which present pupil sizes. To obtain measurements, the lux meter was placed in the chin rest in the corneal plane and the room was completely dimmed. Ten measurements were taken for each device. The illumination levels for white and red Placido disk corneal topographers were 1253.1 ± 0.2 and 329.0 ± 0.2 lux, respectively (both photopic conditions). Scheimpflug corneal tomography should be considered as a mesopic measurement (14.5 ± 0.1 lux). Optical coherence tomography and autorefractometry are scotopic measurements (0.4-0.6 lux). We postulate that producers should provide illumination levels of their devices measuring pupil size. Moreover, when mentioning a pupil size, one should consider presenting to what lighting conditions it refers to.


Assuntos
Visão de Cores , Lentes Intraoculares Multifocais , Humanos , Iluminação , Córnea , Tomografia de Coerência Óptica
10.
J Cataract Refract Surg ; 50(1): 84-94, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-38133648

RESUMO

The pinhole effect is commonly used to discriminate uncorrected refractive error from ocular diseases. A small aperture limits the width of light beams entering the eye, thus increasing the depth of focus. The pinhole effect has also been used in spectacles, contact lenses, corneal inlays, and intraocular lenses (IOLs) to improve reading by compensating for loss of accommodative function. Pinhole spectacles improve near visual acuity, but reduce reading speed, increase interblink interval, and decrease tear break-up time. For contact lenses and IOLs, pinhole devices are usually used in the nondominant eye, which allow compensation of various refractive errors and decrease spectacle dependence. Pinhole corneal inlays are implanted during laser in situ keratomileusis or as a separate procedure. Pinhole IOLs are gaining popularity, particularly as they do not bring a risk of a local inflammatory reaction as corneal inlays do. Disadvantages of using the pinhole effect include high susceptibility to decentration, decrease in retinal luminance levels, and difficulties in performing fundus examinations or surgery in eyes with implanted devices. There are also concerns regarding perceptive issues with different retinal illuminances in the 2 eyes (the Pulfrich effect).


Assuntos
Lentes de Contato , Lentes Intraoculares , Erros de Refração , Humanos , Visão Ocular , Acuidade Visual , Acomodação Ocular
12.
J Binocul Vis Ocul Motil ; 73(4): 124-130, 2023 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-37526941

RESUMO

INTRODUCTION: Unilateral or asymmetric astigmatism is considered a principal refractive error leading to amblyopia and regular eye examinations should be carried out during childhood to prevent visual impairment. The aim of this study was to evaluate the prevalence of astigmatism and spectacle wear among Polish schoolchildren. METHODS: A cross sectional study was carried out in children aged 6 to 14 years old from 50 schools in Poland. The presence of astigmatism was assessed by non-cycloplegic autorefraction, and defined as a cylinder equal or greater than 0.75 D. Children were classified as living in urban or rural areas according to the school location. Spectacle wear was defined as having spectacles at school. RESULTS: The study included 1041 children and 52.3% were girls (n = 544). The mean age was 8.62 ± 2.04 years. The prevalence of astigmatism was 7.3% (95% confidence interval [CI]: 5.8-9.1%). Only 21.7% of children with astigmatism wore spectacles at school. Astigmatism was diagnosed in 8.2% of boys (95% CI: 6.0-11.0%) and 6.4% of girls (95% CI: 4.5-8.8%; p = .13); cylindrical anisometropia was present in 19/76 (25.0%) of children with astigmatism (95% CI: 15.8%-36.3%). Against-the-rule astigmatism was the most common; it was observed in 48.7% of children with astigmatism, followed by with-the-rule astigmatism (44.7%) and oblique astigmatism (6.6%). The prevalence of astigmatism was not linearly correlated with age (r = 0.24; p = .53). Gender, age and place of living were not significantly associated with the presence of astigmatism. CONCLUSIONS: This study reports a low prevalence of astigmatism in Polish school children. However, the majority of children with astigmatism were uncorrected. Further longitudinal studies are warranted.


Assuntos
Astigmatismo , Masculino , Criança , Feminino , Humanos , Adolescente , Polônia , Prevalência , Óculos , Estudos Transversais
14.
Medicina (Kaunas) ; 59(5)2023 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-37241130

RESUMO

Purpose: To investigate the iridocorneal angle-to-angle (ATA), sclera spur-to-sclera spur (STS), and white-to-white (WTW) ocular diameters and their potential influence on anterior chamber intraocular lens (ACIOL) and implantable collamer lens (ICL) sizing in Chinese subjects by using a swept-source optical coherence tomography system (SS-OCT). Design: A retrospective, observational, cross-sectional study. Methods: In 60 right eyes (60 subjects), the ATA, STS, and WTW were measured in six axes (0°-180°, 30°-210°, 60°-240°, 90°-270°, 120°-300°, and 150°-330°) using SS-OCT. The ACIOL and ICL sizes were calculated based on horizontal and vertical axes anterior segment data. A paired sample t-test was used to test the differences in each parameter across the six axes, the potential difference between each pair of parameters in a given axis, and the artificial lens size difference between the horizontal and vertical directions. Pearson's correlation analysis was used to determine the potential correlation between age and AL, WTW, STS, and ATA distances. Results: ATA and STS were the longest on the vertical and shortest on the horizontal axis, while WTW was similar on both axes. These three parameters differed only in the vertical axis (F = 4.910, p = 0.008). ATA and STS were by 0.23 ± 0.08 mm (p = 0.005) and 0.21 ± 0.08 mm wider (p = 0.010) than WTW, respectively. ICL size was 0.27 ± 0.23 mm smaller when based on the horizontal than on the vertical axis parameters (p < 0.001), while ACIOL remained similar (p = 0.709). Age correlated negatively and axial length positively with all measured values. ATA, STS, and WTW correlated positively in the same axis (all p < 0.001). Conclusions: ATA and STS were longer in the vertical than in the horizontal direction, while WTW measurements remained similar. ATA and STS diameters more accurately depicted anatomic relationships for phakic IOL sizing than WTW.


Assuntos
Lentes Intraoculares , Tomografia de Coerência Óptica , Humanos , Estudos Transversais , Implante de Lente Intraocular , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos
16.
Rom J Ophthalmol ; 67(1): 33-40, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37089804

RESUMO

Objective: Low levels of outdoor activity are known to be an important risk factor for the development of myopia in schoolchildren. This study aimed to determine outdoor and near work patterns in Polish schoolchildren before and during school closure due to the SARS-CoV-2 pandemic. Methods: All children undergoing a routine pediatric examination in the Elblag branch of the Hygeia Clinic, together with their parents, were asked to fill an anonymous questionnaire. The subject's age, spherical equivalent (SE) refractive error, time spent outdoors, screen time and total near work in hours per day before and during the pandemic, were recorded. As substantial differences in physical activity by time of year were reported, activity patterns for June (summer) and December (winter) were recorded. Multiple logistic regression analysis was used to analyze the association between the presence of myopia and outdoor and total near work time at different timepoints. Results: A total of 61 schoolchildren aged 11.95 ± 2.74 (range 7 to 17) years were included in this study. The mean SE in the right eye was -1.78 ± 2.11 with 46% of the individuals (n=28) classified as myopic. Before the pandemic, higher time outdoors was associated with less myopic SE (OR=0.47, 95% Confidence Interval [CI] 0.24 to 0.93). During the pandemic, time outdoors among non-myopic children was similar to myopic children, both during winter and summer months (2.18 ± 1.81 vs. 1.89 ± 1.50; P=.51, and 3.47 ± 2.66 vs. 3.31 ± 1.65; P=.79 respectively). Time outdoors was not significantly associated with myopia during the pandemic (OR=1.17, 95% CI 0.64 to 2.14). Total near work was not associated with myopia at any time point. Conclusion: The long-term influence of the changing patterns of outdoor and near work on myopia prevalence and progression in our population is still to be established. Nevertheless, it is likely that the decrease of outdoor time may influence the rates of myopia in this region.


Assuntos
COVID-19 , Miopia , Humanos , Criança , SARS-CoV-2 , Pandemias , Atividades de Lazer , COVID-19/epidemiologia , Inquéritos e Questionários , Miopia/epidemiologia
17.
Cont Lens Anterior Eye ; 46(4): 101846, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37117129

RESUMO

INTRODUCTION: Keratoconus is defined as central and/or paracentral corneal thinning and steepening with consequent irregular astigmatism. To date, no prospective study has reported its prevalence in Central Europe. This study aimed to evaluate the prevalence of keratoconus assessed with Scheimpflug imaging in a profile of general medicine practice in Poland. METHODS: This cross-sectional study collected data by inviting all patients aged 10-80 years subscribed to a single general practitioner in the Elblag area, Poland. Corneal measurements were performed using a rotating Scheimpflug corneal tomography system. Three masked examiners established the diagnosis of keratoconus in the right or left eye. Fleiss' kappa coefficient (κ) was used to qualitatively analyze the interexaminer agreement. RESULTS: Of 1,705 patients invited to the study, 771 agreed to participate (45.2%). The mean age of the 728 patients (60.6% female and 39.4% male) with gradable images in at least one eye was 53.6 ± 16.5 years. All of the examiners classified the same four cases as keratoconus (0.549%, 549 per 100,000, 95% confidence interval 150 to 1,400 per 100,000), of which two were bilateral. Fleiss' kappa showed almost perfect agreement among the three examiners regarding the diagnostic decision (κ = 0.784, 95% confidence interval 0.750 to 0.817, p < 0.001). The keratoconus cases were all women (p = 0.106), aged 48, 69, 70, and 71 years old. CONCLUSION: The prevalence of keratoconus in this area was higher than that previously demonstrated in many European countries. Underestimation of the prevalence has been postulated but never demonstrated.


Assuntos
Ceratocone , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Ceratocone/diagnóstico , Ceratocone/epidemiologia , Estudos Transversais , Topografia da Córnea/métodos , Polônia/epidemiologia , Prevalência , Córnea , Atenção Primária à Saúde
18.
BMC Ophthalmol ; 23(1): 182, 2023 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-37101115

RESUMO

PURPOSE: Precise ocular measurements are fundamental for achieving excellent target refraction following both cataract surgery and refractive lens exchange. Biometry devices with swept-source optical coherence tomography (SS-OCT) employ longer wavelengths (1055-1300 nm) in order to have better penetration through opaque lenses than those with partial coherence interferometry (PCI) or low-coherence optical reflectometry (LCOR) methods. However, to date a pooled analysis showing the technical failure rate (TFR) between the methods has not been published. The aim of this study was to compare the TFR in SS-OCT and in PCI/LCOR biometry. METHODS: PubMed and Scopus were used to search the medical literature as of Feb 1, 2022. The following keywords were used in various combinations: optical biometry, partial coherence interferometry, low-coherence optical reflectometry, swept-source optical coherence tomography. Only clinical studies referring to patients undergoing routine cataract surgery, and employing at least two (PCI or LCOR vs. SS-OCT) optical methods for optical biometry in the same cohort of patients were included. RESULTS: Fourteen studies were included in the final analysis, which presented results of 2,459 eyes of at least 1,853 patients. The overall TFR of all included studies was 5.47% (95% confidence interval [CI]: 3.66-8.08%; overall I2 = 91.49%). The TFR was significantly different among the three methods (p < 0.001): 15.72% for PCI (95% CI: 10.73-22.46%; I2 = 99.62%), 6.88% for LCOR (95% CI: 3.26-13.92%; I2 = 86.44%), and 1.51% for SS-OCT (95% CI: 0.94-2.41%; I2 = 24.64%). The pooled TFR for infrared methods (PCI and LCOR) was 11.12% (95% CI: 8.45-14.52%; I2 = 78.28%), and was also significantly different to that of SS-OCT: 1.51% (95% CI: 0.94-2.41%; I2 = 24.64%; p < 0.001). CONCLUSIONS: A meta-analysis of the TFR of different biometry methods highlighted that SS-OCT biometry resulted in significantly decreased TFR compared to PCI/LCOR devices.


Assuntos
Extração de Catarata , Catarata , Cristalino , Humanos , Comprimento Axial do Olho , Tomografia de Coerência Óptica/métodos , Biometria/métodos , Interferometria , Reprodutibilidade dos Testes
19.
J Glaucoma ; 32(6): 451-457, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37054398

RESUMO

PRCIS: Among patients who underwent uneventful cataract surgery, an advantage was seen to blue-light filtering (BLF) intraocular lenses (IOLs) in terms of glaucoma-free survival and glaucoma procedure-free survival. Among patients with preexisting glaucoma, no advantage was seen. PURPOSE: To assess the effect of BLF IOLs on the development and progression of glaucoma after cataract surgery. PATIENTS AND METHODS: A retrospective cohort study of patients who underwent uneventful cataract surgery between 2007 and 2018 at Kymenlaakso Central Hospital, Finland. Survival analyses for the overall risk of developing glaucoma or undergoing glaucoma procedures were assessed between patients who received a BLF IOL (SN60WF) and a non-BLF IOL (ZA9003 and ZCB00). A separate analysis was performed on patients with preexisting glaucoma. RESULTS: Included 11,028 eyes of 11,028 patients with a mean age of 75 ± 9 years (62% females). The BLF IOL was used in 5188 eyes (47%) and the non-BLF IOL in 5840 eyes (53%). During the follow-up (mean: 55 ± 34 mo), 316 cases of glaucoma were diagnosed. Glaucoma-free survival rates showed an advantage to the BLF IOL ( P = 0.036). In a Cox regression analysis controlling for age and sex the use of a BLF IOL was again associated with a lower ratio of glaucoma development (hazard ratio:0.778; 95% CI: 0.621-0.975). Furthermore, glaucoma procedure-free survival analysis revealed an advantage to the BLF IOL (hazard ratio:0.616; 95% CI: 0.406-0.935). Among 662 cases, which already had glaucoma at the time of surgery, no significant differences were seen in any outcome. CONCLUSIONS: Among a large cohort of patients who underwent cataract surgery, the use of BLF IOLs was associated with favorable glaucoma outcomes compared with the use of non-BLF IOLs. Among patients with preexisting glaucoma, no significant advantage was seen.


Assuntos
Extração de Catarata , Catarata , Glaucoma , Lentes Intraoculares , Feminino , Humanos , Idoso , Idoso de 80 Anos ou mais , Masculino , Implante de Lente Intraocular/efeitos adversos , Estudos Retrospectivos , Pressão Intraocular , Extração de Catarata/efeitos adversos , Glaucoma/diagnóstico , Glaucoma/etiologia , Catarata/etiologia
20.
J Cataract Refract Surg ; 49(7): 679-685, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-36940191

RESUMO

PURPOSE: To analyze new-onset mental and behavioral disorders and nervous system diseases in patients with cataract implanted with either non-blue-light filtering (BLF) or BLF intraocular lenses (IOLs) in both eyes. SETTING: Department of Ophthalmology, Kymenlaakso Central Hospital, Kotka, Finland. DESIGN: A retrospective registry-based cohort study of patients operated between September 2007 and December 2018 who were followed until December 2021. We included 4986 patients who underwent bilateral cataract surgery. METHODS: Patients were implanted with either non-BLF IOLs (N = 2609) or BLF IOLs (N = 2377) in both eyes. Follow-up before the first-eye surgery and between the first-eye and the second-eye surgery was performed to acknowledge the preexisting disorders and diseases. After the second-eye surgery, the groups were analyzed for the new-onset mental and behavioral disorders and diseases of the nervous system subcategorized by the International Classification of Diseases codes. RESULTS: 1707 male and 3279 female patients, aged 73.2 ± 8.6 years at the first-eye surgery and 74.3 ± 8.8 years at the second-eye surgery, were identified. In univariate log-rank tests, the use of BLF IOLs showed no association in overall new-onset disorders or diseases over non-BLF IOLs, in any subtype diagnosis codes except for sleep disorders, which favored BLF IOLs ( P = .003). A multivariate analysis adjusted for age and sex identified no associations in any new-onset disorders or diseases. Multivariate analysis of sleep disorders showed a nonsignificant advantage for BLF-IOLs (hazard ratio 0.756, 95% CI 0.534-1.070, P = .114). CONCLUSIONS: BLF IOLs were not associated with mental and behavioral disorders or diseases of the nervous system.


Assuntos
Catarata , Lentes Intraoculares , Transtornos do Sono-Vigília , Humanos , Masculino , Feminino , Estudos de Coortes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...