1.
Contrast Media Mol Imaging ; 3(1): 27-37, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18335477

RESUMO

Iron oxide particles are especially suited for cell tracking experiments due to their extraordinarily molar relaxivity as compared with other paramagnetic nuclei. We have compared different iron oxide particles (Sinerem, Endorem and magnetic microspheres) for their suitability to label embryonic stem cells (D3 cell line). In addition to detectability thresholds, particular attention has been paid to the evaluation of long-term stability of the labelling procedure (up to 4 weeks) as well as to toxic and other adverse effects on cell viability. Comparative studies were performed using neural progenitor cells (C17.2) and dendritic cells. The present study indicates strong dependence of the label efficiency and stability on the iron oxide particles and cell lines in use.


Assuntos
Meios de Contraste/farmacologia , Células Dendríticas/citologia , Células-Tronco Embrionárias/citologia , Compostos Férricos/farmacologia , Imageamento por Ressonância Magnética , Animais , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Meios de Contraste/efeitos adversos , Estabilidade de Medicamentos , Compostos Férricos/efeitos adversos , Camundongos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...