Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
J Cardiol ; 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38964711

RESUMO

BACKGROUND: Heart transplantation (HTx) is a definitive therapy for refractory heart failure. Cardiac allograft vasculopathy (CAV), characterized by diffuse arteriopathy involving the epicardial coronary arteries and microvasculature, is the major cause of death for patients with HTx. 13N-ammonia positron emission tomography (NH3-PET) can offer diagnostic and prognostic utility for CAV. The splenic switch-off (SSO) detected in NH3-PET is a hemodynamic indicator of favorable response to adenosine. We hypothesized that both CAV and SSO reflected a pathology that progresses in parallel with systemic vascular endothelial dysfunction. Therefore, we quantitatively evaluated splenic adenosine reactivity measured using NH3-PET as an index of endothelial function, and examined its predictability for CAV. METHODS: Forty-eight patients who underwent NH3-PET after HTx were analyzed. The spleen ratio was calculated as the mean standardized uptake value, measured by placing an ROI on the spleen, at stress divided by that at rest. SSO was defined by a cutoff determined using receiver operating characteristic (ROC) analysis for the spleen ratio. The endpoint was appearance or progression of CAV. Predictability of SSO was analyzed using Kaplan-Meier analysis. RESULTS: The endpoint occurred in 9 patients during a mean follow-up of 45 ±â€¯17 months. ROC curve analysis demonstrated a cutoff of 0.94 for spleen ratio. Patients without SSO displayed a significantly higher CAV rate than those with SSO (p = 0.022). CONCLUSIONS: SSO reflects the endothelial function of systemic blood vessels and was a predictor of CAV in patients with HTx.

2.
Radiol Cardiothorac Imaging ; 6(3): e230298, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38814185

RESUMO

Purpose To investigate whether right ventricular (RV) myocardial strain ratio (RVMSR) assessed using nitrogen 13 ammonia (13N-NH3) PET can predict cardiovascular events in patients with ischemic heart disease (IHD). Materials and Methods This retrospective study included 480 consecutive patients (mean age, 66 years ± 12 [SD]; 334 males and 146 females) with IHD who underwent 13N-NH3 PET. RVMSR was defined as the ratio of RV strain during stress to that at rest. The primary end point was major adverse cardiac events (MACEs), defined as cardiac death or heart failure hospitalization. The ability of RVMSR to predict MACE was assessed using receiver operating characteristic (ROC) curve and Kaplan-Meier analyses. Cox proportional hazards regression analysis was used to calculate hazard ratios (HRs) with 95% CIs. Results ROC curve analysis identified a sensitivity and specificity of 84% and 82%, respectively, for predicting MACE from RVMSR. Patients with reduced RVMSR (<110.2) displayed a significantly higher rate of MACE than those with a preserved RVMSR (34 of 240 vs four of 240; P < .001). Cox proportional hazards regression analysis of imaging parameters, including myocardial flow reserve, indicated that RVMSR was an independent predictor of MACE (HR, 0.94 [95% CI: 0.92, 0.97]; P < .001). Conclusion RVMSR was an independent predictor of MACE and has potential to aid in the risk stratification of patients with IHD. Keywords: Right Ventricular Myocardial Strain Ratio, Myocardial Flow Reserve, Ischemic Heart Disease, 13N-Ammonia Positron Emission Tomography Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Amônia , Ventrículos do Coração , Isquemia Miocárdica , Radioisótopos de Nitrogênio , Tomografia por Emissão de Pósitrons , Humanos , Masculino , Feminino , Idoso , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/diagnóstico , Estudos Retrospectivos , Tomografia por Emissão de Pósitrons/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Medição de Risco , Pessoa de Meia-Idade , Sensibilidade e Especificidade
3.
World Neurosurg ; 186: e495-e505, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38583563

RESUMO

OBJECTIVE: To clarify the relationships between 11C-methionine (MET) positron emission tomography (PET) metrics and the histology, genetics, and prognosis of adult-type diffuse glioma (ADG) based on the World Health Organization (WHO) 2021 classification. METHODS: A total of 125 newly diagnosed patients with ADG were enrolled. We compared the maximum standardized uptake value (SUVmax), tumor-to-normal background ratio (TNR), metabolic tumor volume (MTV), and total lesion methionine uptake (TLMU) to the histology and genetics of the patients with ADG. We also evaluated the prognoses of the 93 surgically treated patients. RESULTS: The patients with isocitrate dehydrogenase wild ADG showed significantly higher MET-PET metrics (P < 0.05 for all parameters), significantly shorter overall survival and progression-free survival (P < 0.0001 for both) than those of the patients with isocitrate dehydrogenase mutant (IDHm) ADG. In the IDHm ADG group, the SUVmax, MTV, and TLMU values were significantly higher in patients with IDHm grade (G) 4 astrocytoma than patients with IDHm G2/3 astrocytoma (P < 0.05 for all), but not than patients with G2-3 oligodendroglioma. The progression-free survival was significantly shorter in the patients with G4 astrocytoma versus the patients with G2/3 astrocytoma and G3 oligodendroglioma (P < 0.05 for both). The SUVmax and TNR values were significantly higher in recurrent patients than nonrecurrent patients (P < 0.01 for both), but no significant differences were found in MTV or TLMU values. CONCLUSIONS: MET-PET metrics well reflect the histological subtype, WHO grade and prognosis of ADG based on the 2021 WHO classification, with the exception of oligodendroglial tumors. Volumetric parameters were not significantly associated with recurrence, unlike the SUVmax and TNR.


Assuntos
Neoplasias Encefálicas , Glioma , Isocitrato Desidrogenase , Metionina , Tomografia por Emissão de Pósitrons , Organização Mundial da Saúde , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Glioma/diagnóstico por imagem , Glioma/patologia , Prognóstico , Idoso , Isocitrato Desidrogenase/genética , Adulto Jovem , Radioisótopos de Carbono , Estudos Retrospectivos , Carga Tumoral
4.
Ann Nucl Med ; 38(4): 278-287, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38386272

RESUMO

OBJECTIVE: To investigate the potential of whole-body digital 11C-methionine (MET) PET/CT imaging for simultaneous evaluation of thoracic cancer patients suspected of local recurrence (LR) after stereotactic radiosurgery (SRS) for brain metastasis. METHODS: A total of 45 lung or breast cancer patients suspected of LR after SRS were investigated using brain and whole-body MET-PET/CT scans. We compared the tumor-to-normal ratio (TNR) and maximum standardized uptake values (SUVmax) between patients with LR and radiation necrosis (RN) and performed receiver operating characteristic (ROC) analyses. We also investigated associations among extracranial recurrence, intracranial recurrence, primary site, and initial treatment type. RESULTS: A total of 44 LR and 14 RN lesions were analyzed. In the ROC analyses for differentiating LR from RN, TNR showed higher area under the curve (AUC) (0.82) than SUVmax (0.79), and the cutoff TNR value (2.12) was higher than current cutoff values of conventional PET systems. The whole-body scans detected extracranial recurrences in 31.1% of the patients. Recurrence rates were not significantly correlated with existence of intracranial recurrence or primary site, but patients who underwent non-surgical treatment (consisting of stage III/ IV patients according to the Union for International Cancer Control TNM classification or small-cell lung cancer patients) showed significantly higher recurrence than the surgically treated patients (68.8% vs. 10.3%, p = 0.0001). CONCLUSION: In digital MET-PET/CT imaging, TNR was a more useful parameter to differentiate LR from RN than SUVmax, and the cutoff value was higher than those with conventional PET systems. Additional whole-body scans could detect extracranial recurrence and would be especially useful for advanced thoracic cancer patients who underwent non-surgical treatment.


Assuntos
Neoplasias Encefálicas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Metionina , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Racemetionina , Semicondutores , Tomografia por Emissão de Pósitrons/métodos , Recidiva Local de Neoplasia/diagnóstico por imagem
5.
Clin Nucl Med ; 49(2): 116-123, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38108830

RESUMO

PURPOSE OF THE REPORT: The aim of this study was to explore the different patterns of dynamic whole-body (D-WB) FDG PET/CT parameters among liver malignancy types as potential diagnostic clues and investigate the association between static and dynamic PET/CT parameters for each tumor histology. PATIENTS AND METHODS: Seventy-one patients with intrahepatic cholangiocarcinoma (ICC), metastatic liver tumor (MLT), or hepatocellular carcinoma (HCC) who underwent D-WB and static dual-time-point FDG PET/CT were enrolled. We obtained Pearson correlation coefficients between the metabolic rate of FDG (MR FDG ; mg/min/ 100ml) or distribution volume of free FDG (DV FDG , %) and static PET/CT parameters. We compared MR FDG and DV FDG values by tumor type and performed receiver operating characteristic analyses for MR FDG and static images. RESULTS: A total of 12 ICC, 116 MLT, and 36 HCC lesions were analyzed. MR FDG and DV FDG showed excellent correlation with early (SUV e ) and delayed SUV max (SUV d ) ( r = 0.71~0.97), but DV FDG in the HCC lesions did not ( r = 0.62 and 0.69 for SUV e and SUV d , respectively) ( P < 0.001 for all). HCC lesions showed significantly lower MR FDG (2.43 ± 1.98) and DV FDG (139.95 ± 62.58) than ICC (5.02 ± 3.56, 207.06 ± 97.13) and MLT lesions (4.51 ± 2.47, 180.13 ± 75.58) ( P < 0.01 for all). The optimal MR FDG could differentiate HCC from ICC and MLT with areas under the curve of 0.84 and 0.80, respectively. Metastatic liver tumor lesions showed the widest distribution of MR FDG and DV FDG values but with no significant difference among most primary sites. CONCLUSIONS: MR FDG was strongly correlated with SUV max in the 3 malignancies and showed utility for differentiating HCC from ICC and MLT. Each tumor type has a different glucose metabolism, and D-WB FDG PET/CT imaging has the potential to visualize those differences.


Assuntos
Carcinoma Hepatocelular , Colangiocarcinoma , Neoplasias Hepáticas , Humanos , Fluordesoxiglucose F18 , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons/métodos , Colangiocarcinoma/diagnóstico por imagem , Colangiocarcinoma/patologia
6.
Ann Nucl Med ; 38(3): 199-209, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38151588

RESUMO

OBJECTIVE: Deep learning approaches have attracted attention for improving the scoring accuracy in computed tomography-less single photon emission computed tomography (SPECT). In this study, we proposed a novel deep learning approach referring to positron emission tomography (PET). The aims of this study were to analyze the agreement of representative voxel values and perfusion scores of SPECT-to-PET translation model-generated SPECT (SPECTSPT) against PET in 17 segments according to the American Heart Association (AHA). METHODS: This retrospective study evaluated the patient-to-patient stress, resting SPECT, and PET datasets of 71 patients. The SPECTSPT generation model was trained (stress: 979 image pairs, rest: 987 image pairs) and validated (stress: 421 image pairs, rest: 425 image pairs) using 31 cases of SPECT and PET image pairs using an image-to-image translation network. Forty of 71 cases of left ventricular base-to-apex short-axis images were translated to SPECTSPT in the stress and resting state (stress: 1830 images, rest: 1856 images). Representative voxel values of SPECT and SPECTSPT in the 17 AHA segments against PET were compared. The stress, resting, and difference scores of 40 cases of SPECT and SPECTSPT were also compared in each of the 17 segments. RESULTS: For AHA 17-segment-wise analysis, stressed SPECT but not SPECTSPT voxel values showed significant error from PET at basal anterior regions (segments #1, #6), and at mid inferoseptal regions (segments #8, #9, and #10). SPECT, but not SPECTSPT, voxel values at resting state showed significant error at basal anterior regions (segments #1, #2, and #6), and at mid inferior regions (segments #8, #9, and #11). Significant SPECT overscoring was observed against PET in basal-to-apical inferior regions (segments #4, #10, and #15) during stress. No significant overscoring was observed in SPECTSPT at stress, and only moderate over and underscoring in the basal inferior region (segment #4) was found in the resting and difference states. CONCLUSIONS: Our PET-supervised deep learning model is a new approach to correct well-known inferior wall attenuation in SPECT myocardial perfusion imaging. As standalone SPECT systems are used worldwide, the SPECTSPT generation model may be applied as a low-cost and practical clinical tool that provides powerful auxiliary information for the diagnosis of myocardial blood flow.


Assuntos
Aprendizado Profundo , Imagem de Perfusão do Miocárdio , Humanos , Estudos Retrospectivos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Tomografia por Emissão de Pósitrons/métodos , Imagem de Perfusão do Miocárdio/métodos
7.
Ann Nucl Cardiol ; 9(1): 33-39, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38058574

RESUMO

Background: Myocardial blood flow quantification (MBF) is one of the distinctive features for cardiac positron emission tomography. The MBF calculation is mostly obtained by estimating the input function from the time activity curve in dynamic scan. However, there is a substantial risk of count-loss because the high radioactivity pass through the left ventricular (LV) cavity within a short period. We aimed to determine the optimal intraventricular activity using the noise equivalent count rate (NECR) analysis with simplified phantom model. Methods: Positron emission tomography computed tomography scanner with LYSO crystal and time of flight was used for phantom study. 150 MBq/mL of 13N was filled in 10 mL of syringe, placed in neck phantom to imitate end-systolic small LV. 3D list-mode acquisition was repeatedly performed along radioactive decay. Net true and random count rate were calculated and compared to the theoretical activity in the syringe. NECR curve analysis was used to determine the optimal radioactive concentration. Result: The attenuation curves showed good correlation to the theoretical activity between 20 to 370, and 370 to 740 MBq (r2=1.0 ± 0.0001, p<0.0001; r2=0.99 ± 0.0001, p<0.0001 for 20 to 370, and 370 to 740, respectively), while did not over 740 MBq (p=0.62). NECR analysis revealed that the peak rate was at 2.9 Mcps, there at the true counts were significantly suppressed. The optimal radioactive concentration was determined as 36 MBq/mL. Conclusion: Simulative analysis for high-dose of 13N using the phantom imitating small LV confirmed that the risk of count-loss was increased. The result can be useful information in assessing the feasibility of MBF quantification in clinical routine.

8.
J Neurosurg ; 139(6): 1671-1680, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37410630

RESUMO

OBJECTIVE: Diagnosis and accurate localization of recurrent tumors in Cushing's disease (CD) are challenging, especially after multiple transsphenoidal surgeries (TSSs) or radiosurgery. Even experts face difficulties in detecting these recurrent tumors, and a favorable surgical outcome is not guaranteed. In this report, the authors aimed to determine the usefulness of 11C-methionine positron emission tomography (MET-PET) for evaluating patients with recurrent CD with inconclusive magnetic resonance imaging (MRI) lesions and to develop a treatment protocol for these cases. METHODS: In this retrospective study of patients with recurrent CD in the period between April 2018 and December 2022, the authors assessed the usefulness of MET-PET in determining whether equivocal MRI findings were recurrent tumors or postsurgical cavities and deciding further treatment options. All patients had undergone at least one TSS, and most had undergone multiple TSSs and had pathologically confirmed corticotroph tumors with hypercortisolemia. RESULTS: Overall, 15 patients with recurrent CD (10 females and 5 males) were included, all of whom had undergone MET-PET. All patients had been subjected to multiple treatments, including TSSs or radiosurgeries. Their MRI scans demonstrated less-enhanced lesions that were not confirmed as recurrences even with cutting-edge MRI because they could not be distinguished from postsurgical changes with confidence. MET uptake was positive in 8 patients (9 examinations) and negative in 7. Following MET-PET, repeat TSS was performed in 5 patients. Corticotroph tumors were identified in all 5 patients, even though one of them had negative MET uptake. The MET uptake precisely identified a tumor location on the opposite side of the MRI-suspected lesion in 2 patients. Meanwhile, patients with negative uptake and mild hypercortisolism were only observed. Nonsurgical options were also used in other patients: temozolomide (TMZ) was administered in 2 patients owing to a prior history of multiple TSSs and radiosurgery and the drug-resistant nature of the disease. TMZ was highly effective in these patients; their Cushing's symptoms ameliorated, and their adrenocorticotropic hormone and cortisol levels continued to decline. Interestingly, MET uptake disappeared following TMZ treatment. CONCLUSIONS: MET-PET is extremely useful for confirming equivocal lesions on MRI in patients with recurrent CD and for deciding further treatment options. The authors propose a novel protocol based on MET-PET results for treating patients with relapsing CD in whom the recurrent tumors cannot be confirmed with MRI.


Assuntos
Neoplasias , Hipersecreção Hipofisária de ACTH , Masculino , Feminino , Humanos , Radioisótopos de Carbono , Hipersecreção Hipofisária de ACTH/diagnóstico por imagem , Hipersecreção Hipofisária de ACTH/cirurgia , Estudos Retrospectivos , Tomografia por Emissão de Pósitrons , Imageamento por Ressonância Magnética , Metionina , Racemetionina , Tomada de Decisão Clínica
10.
J Cardiol ; 82(5): 343-348, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37031795

RESUMO

BACKGROUND: Systemic sclerosis (SSc) affects the myocardium, thereby resulting in a poor prognosis. Late gadolinium enhancement (LGE) entropy, derived from routine cardiac magnetic resonance (CMR) LGE images, is an index that reflects the complexity of the left ventricular myocardium. The aim of this study was to investigate whether LGE entropy can serve as a prognostic factor in patients with SSc. METHODS: Twenty-four patients with SSc, who underwent CMR-T1 mapping and LGE to identify myocardial damage, were enrolled, and LGE entropy was measured. Extracellular volume (ECV) values were calculated using the same CMR-LGE images. The endpoint was major adverse cardiac events (MACEs), comprising all-cause death, hospitalization due to heart failure, and the onset of sustained ventricular tachycardia and ventricular fibrillation. The ability to predict MACE was assessed using receiver operating characteristic (ROC) analysis, and the predictability of LGE entropy was analyzed using Kaplan-Meier analysis. RESULTS: The ROC curve analysis demonstrated a cut-off value of 7.39 for MACE with LGE entropy and had a sensitivity and specificity of 80 % and 79 %, respectively. Patients with LGE entropy ≥7.39 had a significantly higher MACE rate than those with LGE entropy <7.39 (p = 0.010). Moreover, LGE entropy ≥7.39 was a poor prognostic factor in patients without elevated ECV values. CONCLUSIONS: LGE entropy can be used to predict MACE and allows for further risk stratification in addition to ECV determination.


Assuntos
Meios de Contraste , Escleroderma Sistêmico , Humanos , Prognóstico , Gadolínio , Entropia , Imagem Cinética por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Pericárdio , Escleroderma Sistêmico/complicações , Escleroderma Sistêmico/patologia , Valor Preditivo dos Testes , Função Ventricular Esquerda
11.
Ann Nucl Med ; 37(7): 419-427, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37119390

RESUMO

OBJECTIVE: To clarify the link between cardiac sarcoidosis (CS) and extra-CS (ECS) in systemic CS (SCS) patients in terms of extent and clinical outcome by serial FDG-PET/CT. METHODS: Thirty-five SCS patients treated for > 2 years were enrolled in this study. In the overall analysis, patient-based comparisons of the complete resolution (CR) and recurrence rate between CS and ECS lesions were performed. Then, subgroup analyses were performed according to the extent (mono- vs. multi-organ ECS group) and clinical outcome (stable vs. unstable ECS group) of ECS. Pre-treatment cardiac FDG uptake was compared between the mono- and multi-organ ECS groups. The rates of CR, recurrence, and major adverse cardiac events (MACE) were compared between the two groups. RESULTS: The CR rate was significantly higher in CS than ECS lesions [77.1% (27/35) vs. 48.5% (17/35), p = 0.01], whereas recurrence rates were similar between CS and ECS [40.7% (11/27) vs. 58.8% (10/17)]. Both the mono- and multi-organ ECS groups showed similar SUVmax, cardiac metabolic volume, and cardiac metabolic activity in the pre-treatment condition. The CR rates were similar between the mono- and multi-organ ECS groups [71.4% (15/21) vs. 85.7% (12/14)], but the recurrence rate was significantly lower in the multi-organ ECS group [60.0% (9/15) vs. 16.7% (2/12), p = 0.02]. The CR [71.4% (5/7) vs. 78.6% (22/28)] and recurrence rates [60.0% (3/5) vs. 36.3% (8/22)] were not significantly different between the stable and unstable ECS groups. The occurrence of MACE was also not significantly different between the mono- and multi-organ ECS groups [19.0% (4/21) vs. 28.6% (4/14)] or between the stable and unstable ECS groups [42.9% (3/7) vs. 17.8% (5/28)]. CONCLUSIONS: CS lesions respond to treatment better than ECS lesions, and the extent and clinical outcome of ECS lesion are not linked with those of CS lesions.


Assuntos
Cardiomiopatias , Sarcoidose , Humanos , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos/uso terapêutico , Cardiomiopatias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Sarcoidose/diagnóstico por imagem , Sarcoidose/terapia
12.
Eur Radiol ; 33(6): 3889-3896, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36562782

RESUMO

OBJECTIVES: Myocardial flow reserve (MFR), derived from ammonia N-13 positron emission tomography (NH3-PET), can predict the prognosis of patients with various heart diseases. We aimed to investigate whether myocardial strain ratio (MSR) was useful in predicting MACE and allowed for further risk stratification of cardiovascular events in patients with ischemic heart disease (IHD) in addition to MFR. METHODS: Ninety-five patients underwent NH3-PET because of IHD. MFR was determined as the ratio of hyperemic to resting myocardial blood flow (MBF). MSR was defined as the ratio of strains at stress and rest. The endpoint was major adverse cardiac events (MACE), including all-cause death, acute coronary syndrome, heart failure hospitalization, and revascularization. The ability to predict MACE was assessed using receiver operating characteristic (ROC) analysis, and the predictability of ME was analyzed using Kaplan-Meier analysis. The Cox proportional hazards regression model was used to calculate the hazard ratio (HR) with 95% confidence interval (CI). RESULTS: The ROC curve analysis demonstrated a cutoff of 0.93 for MACE with MSR (sensitivity and specificity of 77% and 71%, respectively). Patients with MSR < 0.93 displayed a significantly higher MACE rate than those with MSR ≥ 0.93 (p = 0.0036). The Cox proportional hazards regression analysis indicated that MSR was an independent marker that could predict MACE in imaging and clinical parameters (HR, 7.32; 95% CI: 1.59-33.7, p = 0.011). CONCLUSIONS: MSR was an independent predictor of MACE and was useful for further risk stratification in IHD. MSR has the potential for a new indicator of revascularization in patients with IHD. KEY POINTS: • We hypothesized that combining myocardial flow reserve (MFR) with the myocardial strain ratio (MSR) obtained by applying the feature-tracking technique to ammonia N-13 PET would make it predictive of major adverse cardiac events (MACE) compared to MFR alone. • MSR was an independent predictor of MACE, allowing for further risk stratification in addition to MFR in patients with ischemic heart disease. • MSR is a potential new indicator of revascularization.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Insuficiência Cardíaca , Isquemia Miocárdica , Imagem de Perfusão do Miocárdio , Humanos , Amônia , Miocárdio , Isquemia Miocárdica/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Insuficiência Cardíaca/diagnóstico por imagem , Prognóstico , Compostos Radiofarmacêuticos , Imagem de Perfusão do Miocárdio/métodos , Reserva Fracionada de Fluxo Miocárdico/fisiologia
13.
J Nucl Cardiol ; 30(3): 1065-1074, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36192524

RESUMO

AIMS: We aimed to investigate the pre-treatment characteristics and treatment responses of isolated and systemic cardiac sarcoidosis (ICS and SCS) from FDG-PET/CT studies and to compare the prognoses of the two groups. METHODS: FDG-PET/CT images taken before and after treatment of 31 ICS and 91 SCS patients were analyzed retrospectively. Treatment response and recurrence were determined from the course of FDG-PET/CT. Treatment response and the incidence of both recurrence and major adverse cardiac events (MACE) were assessed in 16 ICS and 35 SCS patients who had been treated for more than 2 years. RESULTS: A focal uptake pattern was more often observed than a focal-on-diffuse uptake pattern in both the ICS (74.2%) and SCS (63.7%) groups. Right ventricular involvement was significantly more frequent in SCS than ICS (44.0% vs. 9.6%, p < .001). SUVmax, cardiac metabolic volume (CMV), and cardiac metabolic activity (CMA) were significantly higher in SCS than ICS (SUVmax, 9.1 ± 4.1 vs. 4.8 ± 2.1; CMV, 118.0 ± 111.3 ml vs. 68.3 ± 94.7 ml; CMA, 541.6 ± 578.7 MBq vs. 265.1 ± 396.0 MBq, p < .001). Treatment responses in the two groups were similar, and complete resolution of cardiac uptake after immunosuppressive treatment was obtained in 62.5% of ICS patients and 77.1% of SCS patients (not significantly different). Likewise, no significant difference was found in the incidence of recurrence (40.0% for ICS, 44.4% for SCS) or MACE (25.0% for ICS, 22.8% for SCS). CONCLUSION: SCS patients had more active and extensive CS lesions than ICS patients before treatment, but the two groups showed similar treatment responses and prognoses.


Assuntos
Cardiomiopatias , Miocardite , Sarcoidose , Humanos , Cardiomiopatias/metabolismo , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Sarcoidose/metabolismo , Metabolismo Energético
14.
Am J Cardiol ; 180: 149-154, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-35918233

RESUMO

Late gadolinium enhancement (LGE) on cardiac magnetic resonance (CMR) imaging can help detect myocardial damage. 123I-betamethyl-p-iodophenyl-pentadecanoic acid single-photon emission computed tomography (BMIPP-SPECT) was developed to evaluate fatty acid metabolism and has been reported to help detect myocardial damage in cardiac sarcoidosis (CS). We analyzed data from CMR-LGE and performed BMIPP-SPECT in patients with CS taking prednisolone and investigated the association of BMIPP-SPECT with LGE as a prognostic factor in CS. Patients with CS who underwent BMIPP-SPECT and CMR-LGE at the time of diagnosis within 2 months were classified into those with and without a major adverse cardiac event (MACE). Total BMIPP-SPECT defect score (BDS) and LGE extent score (LES) were used to estimate myocardial damage. The relation between BDS and LES was explored using Pearson's correlation coefficient. Their ability to predict MACEs was analyzed using Kaplan-Meier analysis. Medical data of 45 patients were analyzed retrospectively (mean follow-up, 4.5 years). BDS and LES were significantly correlated (p <0.0001). BDS was significantly greater for the group with MACE than that without MACE (p = 0.0008). LES of patients with MACE was significantly greater than those without MACE (p = 0.0045). Patients with BDS ≥16 had a significantly higher MACE rate than those with BDS <16 (p = 0.0029). The group with LES ≥9 was significantly associated with MACE (p = 0.0098). In conclusion, BDS reflected myocardial damage similar to that detected by CMR-LGE and was a predictive marker of MACE in patients with CS. BMIPP-SPECT may help predict the prognosis of patients with CS who cannot undergo CMR-LGE.


Assuntos
Miocardite , Sarcoidose , Meios de Contraste , Ácidos Graxos , Gadolínio , Humanos , Radioisótopos do Iodo , Imagem Cinética por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Prognóstico , Estudos Retrospectivos , Sarcoidose/diagnóstico , Sarcoidose/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos
15.
Int Heart J ; 63(2): 202-209, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35354742

RESUMO

13N-ammonia positron emission tomography (NH3-PET) can evaluate myocardial blood flow (MBF) at rest, stress, and myocardial flow reserve (MFR) as well as the ratio of MBF at stress to that at rest. MFR is useful in predicting the prognoses of patients with various heart diseases. Cadmium-zinc-telluride single photon emission computed tomography (CZT-SPECT) enables us to acquire dynamic images of radiotracer kinetics and measure original MBF and MFR using 99mTc-sestamibi. This study aimed to investigate the utility of CZT-SPECT for quantitative assessment of MBF compared to NH3-PET. We validated the correlation of MBF and MFR between CZT-SPECT and NH3-PET. Fourteen patients using one-day rest/stress CZT-SPECT, D-SPECT followed by NH3-PET within 1 month were enrolled and analyzed prospectively. The reproducibility of the MBF and MFR obtained with these two methods was examined using Spearman's correlation coefficient and Bland-Altman plot analysis. The diagnostic value of D-SPECT for abnormal MFR defined using NH3-PET results as MFR < 2.0 was assessed using receiver-operating characteristic (ROC) analysis. The median duration between D-SPECT and NH3-PET was 20 days. Although MBF was overestimated by D-SPECT compared to NH3-PET at high value (mean difference, 0.43 [0.34-0.53]), MBF and MFR were correlated with the two modalities (MBF: r = 0.71, P < 0.0001, MFR: r = 0.60, P < 0.0001). The ROC curve analysis demonstrated a cutoff of 1.6 for detecting abnormal MFR with D-SPECT (sensitivity, 68%; specificity, 91%; AUC, 0.75). MBF and MFR obtained using D-SPECT and NH3-PET had a good correlation, suggesting that the quantitative MFR evaluation by CZT-SPECT may help understand the trend of NH3-PET MFR.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Amônia , Circulação Coronária , Humanos , Imagem de Perfusão do Miocárdio/métodos , Tomografia por Emissão de Pósitrons/métodos , Reprodutibilidade dos Testes , Tomografia Computadorizada de Emissão de Fóton Único/métodos
16.
Eur J Nucl Med Mol Imaging ; 49(6): 1870-1880, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34897553

RESUMO

PURPOSE: We developed a feature-tracking algorithm for use with electrocardiography-gated high-resolution 13 N-ammonia positron emission tomography (PET) imaging, and we hypothesized it could be used to clarify the association between right ventricular (RV) longitudinal strain (LS) and right coronary artery (RCA) ischemia. The aim of this study was to investigate the association between the reduction of regional myocardial flow reserve (MFR) in RCA territories and PET-derived LS of the RV free wall. METHODS: Ninety-three patients with coronary artery stenosis > 50%, diagnosed by coronary computed tomography angiography, and 10 controls were retrospectively analyzed. RV-LS in the free wall was measured by a feature-tracking technique on the resting and stressed 13 N-ammonia PET images of horizontal long axis slices. The patients were sub-grouped according to regional MFR values at the territories of RCA, left anterior descending artery (LAD), and left circumflex coronary artery (LCx): RCA-MFR < 2.0 [n = 34], RCA-MFR ≥ 2.0 but MFR < 2.0 at LAD or LCx territories [n = 11], and MFR ≥ 2.0 for all territories [n = 48]. Stress and resting RV-LS were compared in each of the four groups. Multiple comparisons of RV-LS among the four groups were performed in the stress and resting state. RESULTS: Decreased stress RV-LS in patients with an RCA-MFR < 2.0 was observed. In the patients with MFR ≥ 2.0 for all territories, the stressed RV-LS was significantly increased compared to that in the resting state. Significantly decreased RV free wall LS during adenosine stress in patients with RCA-MFR < 2.0 was observed in the other three groups. CONCLUSIONS: We measured RV myocardial LS using feature tracking in cine imaging of 13 N-ammonia PET. The results of this study suggest that PET-derived stressed RV-LS is useful for detecting reduced RV myocardial motion due to ischemia in the RCA territory.


Assuntos
Amônia , Doença da Artéria Coronariana , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária , Humanos , Tomografia por Emissão de Pósitrons/métodos , Estudos Retrospectivos
17.
Ann Nucl Med ; 36(1): 70-81, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34643890

RESUMO

OBJECTIVE: Heart transplant rejection leads to cardiac allograft vasculopathy (CAV). 13N-ammonia positron emission tomography (PET) can be useful in detecting CAV, as it can evaluate both epicardial vessels and microvasculature. In this study, we evaluated the regional wall motion in heart transplant patients using our PET-specific feature-tracking (FT) algorithm for myocardial strain calculation and validated it using a cardiovascular magnetic resonance (CMR) FT strain as a reference. METHODS: A total of 15 heart transplant patients who underwent both 13N-ammonia PET and CMR within 3 months were retrospectively enrolled. The same slice position of short-axis cine images of the middle slice of left ventricle (LV) and the same slice position of horizontal long-axis cine images were selected for the two modalities to measure the circumferential strain (CS) and longitudinal strain (LS), respectively. Based on the FT technique, time-strain curves were calculated by semi-automatic tracking of the endocardial contour on cine images throughout a cardiac cycle. The peak value in the time-strain curve was defined as the representative value. Correlations of CS and LS between PET and CMR were analyzed using Pearson correlation coefficients. The inter-modality error of strain measurements was evaluated using intraclass correlation coefficients (ICCs) with two-way random single measures. RESULTS: Excellent correlations of CS and LS between PET and CMR were observed (CS: r = 0.80; p < 0.01; LS: r = 0.87; p < 0.01). Excellent ICCs were observed (0.89 and 0.85) in CS and LS derived from PET. CONCLUSIONS: We propose the first PET strain showing an excellent agreement with the CMR strain and high reproducibility in measurement.


Assuntos
Função Ventricular Esquerda
18.
Nucl Med Commun ; 42(12): 1361-1368, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34347656

RESUMO

OBJECTIVES: To clarify differences in arterial 18F-FDG (fluorodeoxyglucose) uptake between silicon photomultiplier (SiPM)-based and conventional PET/CT scanners, and to compare clinical and phantom results. PATIENTS AND METHODS: Twenty-six patients with lung tumours underwent serial SiPM-based and conventional PET/CT scans on the same day. We compared the target-to-background ratios [TBRsi (SiPM), TBRc (conventional)] and the percentage difference between TBRsi and TBRc (ΔTBR) in the carotid artery, aorta and peripheral arteries. The correlation between ΔTBR and vessel size was also investigated. In the carotid artery, active segment analyses were performed with the threshold (TBR ≥1.6), and we compared each scanner's ratio of active segments and TBR values. We compared the clinical results with the recovery coefficients (RCs). RESULTS: The TBRsi was significantly higher than the TBRc in the carotid artery, aorta and peripheral arteries (1.63 ± 0.22 vs. 1.43 ± 0.22, 1.65 ± 0.19 vs. 1.53 ± 0.15 and 1.37 ± 0.31 vs. 1.11 ± 0.27, mean ± SD, P ≤ 0.0001 for all), and the peripheral arteries showed the highest ΔTBR (24.4 ± 16.8%). The small (10-15 mm) vessels (26.9 ± 15.9%) showed significantly higher ΔTBRs than the larger vessels (7.3 ± 8.5% for 15-20 mm, 8.0 ± 12.8% for ≥20 mm, P < 0.0001 for both). The carotid artery showed significantly higher ratios of active segment (54.5 vs. 20.5%, P < 0.0001) and TBR values (1.85 ± 0.25 vs. 1.76 ± 0.15, P = 0.0006) for TBRsi vs. TBRc. The differences in RCs were similar to those of ΔTBR for each vessel size. CONCLUSIONS: SiPM-based PET/CT scanners showed higher arterial 18F-FDG uptake (especially in vessels <15 mm) than conventional scanners, and the threshold TBR ≥1.6 is not applicable for the carotid artery for SiPM-based PET/CT systems.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada
19.
Mod Rheumatol ; 30(2): 358-364, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30843747

RESUMO

Objectives: To clarify differences in incidences of articular and extra-articular involvement in patients with polymyalgia rheumatica (PMR) using FDG-PET/CT.Methods: Twenty PMR patients were enrolled in this retrospective study. We compared frequency, degree, and patterns (diffuse or non-diffuse) of abnormal FDG accumulation in the proximal and distal articular structures (PAS, DAS), and extra-articular synovial structures (ESS). Regional analyses were performed for the large joints (shoulder, hip, and knee).Results: The incidences of positive FDG accumulation were significantly higher in the PAS (96.7%) and ESS (91.4%) than in the DAS (31.8%, p < .0001), although, the incidence in the knees (96.2%) was exceptionally high. PAS (2.79 ± 0.61) and ESS (2.52 ± 0.85) had significantly higher visual scores than DAS (0.89 ± 1.33, p < .0001). Shoulder, hip, and knee joints each had a different accumulation pattern. Strong FDG accumulation was frequently observed in the medial-to-subscapular part of the shoulder joints, the lateral part of the hip joints, and the medial part of the knee joints.Conclusion: ESS were found to be the main affected areas in PMR patients as well as PAS. DAS involvement occurred with low frequency except in the knee joints. Each large joint showed a different accumulation pattern and its own characteristically strongly affected areas.


Assuntos
Cartilagem Articular/diagnóstico por imagem , Polimialgia Reumática/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Idoso , Cartilagem Articular/patologia , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Polimialgia Reumática/patologia , Compostos Radiofarmacêuticos , Imagem Corporal Total
20.
J Thorac Dis ; 9(8): E689-E693, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28932587

RESUMO

Liposarcomas are the most common type of mesenchymal neoplasm in soft tissue sarcomas. Although they frequently develop at the lower limbs or retroperitoneum, cases arising from the mediastinum are rare. Furthermore, the incidence of the inflammatory subtype of well-differentiated liposarcoma is known to be low. We experienced a case of a middle mediastinal liposarcoma in a 68-year-old woman. The tumor, which was completely resected, was 92 mm in diameter. The tumor consisted of two different imaging components that showed different growth and which were diagnosed as the lipoma-like subtype and inflammatory subtype of well-differentiated liposarcoma. To the best of our knowledge, this is the first report of a well-differentiated inflammatory liposarcoma arising from the middle mediastinum.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...