Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Int Heart J ; 63(2): 210-216, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35354743

RESUMO

This study aimed to investigate clinical and preintervention optical coherence tomography (OCT) findings to predict irregular protrusion (IRP) immediately after stent implantation.We evaluated 84 lesions treated with cobalt-chromium everolimus-eluting stent (CoCr-EES) from the MECHANISM Elective study. Patients were divided into two groups according to the presence of IRP [IRP: n = 16, non-IRP: n = 68]. Optical coherence tomography images before intervention and immediately after stenting were evaluated with standard qualitative and quantitative OCT analyses.Total cholesterol and the prevalence of ruptured plaque before intervention were significantly higher in the IRP group than in the non-IRP group [199 ± 37 mg/dL versus 176 ± 41 mg/dL; P = 0.022, 31% versus 7%; P = 0.008]. Total lipid length tended to be longer in the IRP group than in the non-IRP group [19.6 ± 9.2 mm versus 15.5 ± 9.3 mm; P = 0.090]. The prevalence of ruptured plaque, and total cholesterol levels were independent predictors of IRP immediately after stenting by multivariate logistic regression analysis [OR: 4.6, 95% confidence interval: 1.01-21.23, P = 0.048, OR: 1.02, 95% confidence interval: 1.00-1.03, P = 0.046]. IRP post-CoCr-EES implantation was completely resolved at follow-up OCT.The prevalence of ruptured plaque before intervention and total cholesterol levels were independent predictors of IRP after CoCr-EES implantation in patients with stable coronary artery disease.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Doença da Artéria Coronariana/cirurgia , Everolimo/farmacologia , Humanos , Stents
2.
Int J Cardiovasc Imaging ; 37(2): 419-428, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33034867

RESUMO

To compare early vascular healing following cobalt-chromium everolimus-eluting stent (CoCr-EES) implantation between groups with or without aggressive stent expansion in patients treated by CoCr-EES for stable coronary artery disease (CAD). Seventy-one stable CAD lesions underwent CoCr-EES implantation and analysis of serial optical coherence tomography (OCT) images obtained post-procedure and at early-term (1- or 3-month) follow-up. The endpoints of this study were neointimal thickness at the time of 1- or 3-month OCT and presence and healing of stent edge dissection. Aggressive stent expansion was defined as a lesion complying with ILUMIEN III sizing protocol; that is, external elastic lamina (EEL) diameter minus maximum balloon diameter ≤ 0.25 mm.  Comparing groups with and without aggressive stent expansion, median neointimal thickness at 1 and 3 months after CoCr-EES implantation was similar (1 month: 0.031 mm vs. 0.041 mm, respectively, p = 0.27; 3 months: 0.036 mm vs. 0.040 mm, respectively, p = 0.84). Regarding stent edge findings, the presence of any stent edge dissection immediately after percutaneous coronary intervention was also similar between the groups (25% vs. 15%, respectively; p = 0.30) and most stent edge dissections resolved completely within 3 months, regardless of location or dissection severity. After 1 year, no clinically driven target lesion revascularization or stent thrombosis was observed in either cohort. Even after aggressive stent expansion, early neointimal proliferation appeared modest with CoCr-EES implantation, and most stent edge dissections had resolved by 3 months. These findings may support the feasibility of EEL-based sizing by pre-stenting OCT.


Assuntos
Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Tomografia de Coerência Óptica , Idoso , Fármacos Cardiovasculares/administração & dosagem , Ligas de Cromo , Doença da Artéria Coronariana/diagnóstico por imagem , Everolimo/administração & dosagem , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Neointima , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento , Cicatrização
3.
J Cardiol ; 75(6): 641-647, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31924410

RESUMO

OBJECTIVE: The purpose of this study was to identify a cut-off value to predict the resolution of incomplete-stent-apposition (ISA) after cobalt-chromium everolimus-eluting stent (CoCr-EES) implantation at early follow-up. BACKGROUND: To date, appropriate stent apposition at the acute period using intracoronary imaging has been recommended because persistent ISA is considered to be a risk factor for stent thrombosis. We examined the indices for resolving acute ISA. In particular, we determined the cut-off value for strut vessel distance (SV-distance) as visualized by optical coherence tomography (OCT) at 8 months after CoCr-EES implantation. However, the cut-off value of SV-distance for the earlier resolution of ISA is unclear. METHODS: A total of 95 cases and 103 stents were registered in the MECHANISM Elective substudy. The SV-distance was measured at the deepest site of the target malapposition and every 1 mm from the proximal edge to the distal edge of the mal-apposed area using OCT. Cut-off values for ISA resolution at 1 and 3 months were estimated by SV-distance using receiver operating characteristic analysis. RESULTS: The total number of analyzed struts was 14,418 at the 1-month follow-up and 11,986 at the 3-month follow-up. The optimal SV-distance cut-off values just after stent implantation to predict ISA resolution were 185 µm at the 1-month follow-up and 195 µm at the 3-month follow-up. CONCLUSION: For resolution of ISA, SV-distance cut-off values of 185 µm at 1 month postimplantation and 195 µm at 3 months postimplantation can be used as the index of endpoint of the percutaneous coronary intervention.


Assuntos
Stents Farmacológicos , Everolimo/administração & dosagem , Imunossupressores/administração & dosagem , Tomografia de Coerência Óptica/métodos , Idoso , Ligas de Cromo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
4.
Int J Cardiovasc Imaging ; 35(11): 1979-1987, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31256285

RESUMO

The purpose of this study was to clarify a cut-off value for acute incomplete stent apposition (ISA) volume and maximum-depth to predict ISA resolution at 1- and 3-month follow-up in patients treated with cobalt-chromium everolimus-eluting stents. In total, 95 cases and 103 stents were registered in the MECHANISM-Elective sub-study. Acute ISA-volume was measured by the trapezoid rule. ISA resolution of cut-off value at 1- and 3-month was estimated by ISA-volume and maximum-depth using receiver operatorating characteristic curve analysis. The total number of analysed acute ISAs was 202 in the 1-month group and 225 in the 3-month group. A total of 123 ISAs at 1-month and a total of 169 ISAs at 3-month had been resolved. The cut-off value of ISA resolution by ISA-volume was 0.169 mm3 at 1-month (AUC: 0.725, sensitivity: 72.2%, specificity: 61.0%) and 0.295 mm3 at 3-month (AUC: 0.757, sensitivity: 75.0%, specificity: 60.4%). The cut-off value of ISA resolution by ISA maximum-depth demonstrated was 0.285 mm at 1-month (area under curve (AUC): 0.789, sensitivity: 70.9%, specificity: 69.9%) and 0.305 mm at 3-month (AUC: 0.663, sensitivity: 60.7%, specificity: 66.9%). Incidence of ISA resolution was significantly lower in combination with cut-off values of ISA-volume and maximum-depth (33%, p < 0.001, at 1-month; 56%, p = 0.003, at 3-month). Combining the cut-off value of ISA-volume with the maximum-depth might be helpful to consider the endpoint of the PCI procedure.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Ligas de Cromo , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Tomografia de Coerência Óptica , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Everolimo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento
5.
Atherosclerosis ; 265: 117-123, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28881269

RESUMO

BACKGROUND AND AIMS: The aim of this study was to evaluate the accumulation of optical coherence tomography (OCT)-macrophages and OCT findings after CoCr everolimus-eluting stent placement, in addition to coronary risk factors. METHODS: A total of 89 lesions in 89 patients were registered in the 1- and 3-month cohort of the multi-centre study. Lesion characteristics and post-procedure OCT images were evaluated immediately and 1 and 3 months after stenting. Patients were divided into low and high macrophage grade groups based on the median macrophage grade. RESULTS: Low-density lipoprotein cholesterol (LDL-C) levels, the prevalence of diabetes mellitus, HbA1c and blood glucose levels in the high macrophage grade group were significantly higher than in the low macrophage grade group (p = 0.025, p = 0.040, p = 0.032, and p = 0.010). Moreover, total lipid arc and length and number of thin-cap fibroatheromas (TCFAs) in the high macrophage grade group were significantly higher than in the low macrophage group (p = 0.008, p = 0.002, and p = 0.012). After CoCr everolimus-eluting stenting, there was a trend towards a greater number, height, and area of irregular protrusions in the high macrophage grade group compared to the low macrophage grade group (p = 0.091, p = 0.059, and p = 0.085). Multivariate logistic regression analysis showed that diabetes mellitus was a significant predictor of high macrophage grades (odds ratio: 2.8, 95% CI: 1.1-7.3, p = 0.030). CONCLUSIONS: The accumulation of OCT-macrophages was associated with diabetes mellitus in patients with coronary artery disease. Moreover, macrophage accumulation and diabetes mellitus may be associated with irregular protrusions just after stenting.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Ligas de Cromo , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Everolimo/administração & dosagem , Macrófagos/patologia , Intervenção Coronária Percutânea/instrumentação , Tomografia de Coerência Óptica , Idoso , Biomarcadores/sangue , Glicemia/metabolismo , Fármacos Cardiovasculares/efeitos adversos , Distribuição de Qui-Quadrado , LDL-Colesterol/sangue , Comorbidade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/patologia , Vasos Coronários/metabolismo , Vasos Coronários/patologia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Everolimo/efeitos adversos , Feminino , Hemoglobinas Glicadas/metabolismo , Humanos , Japão/epidemiologia , Modelos Logísticos , Macrófagos/metabolismo , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Prevalência , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
6.
Coron Artery Dis ; 26(3): 201-11, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25714072

RESUMO

BACKGROUND: Although it is known that in-stent restenosis (ISR) patterns appear homogeneous or nonhomogeneous by optical coherence tomography (OCT), interpretations of the ISR inflammatory response, of the OCT image, and its pathological implications are unclear. The aim of this study was to use OCT to characterize ISR and its inflammatory index in patients after coronary stenting. METHODS: OCT was performed at follow-up in 100 angiographic ISR lesions. ISR lesions were divided into two groups: (a) homogeneous (n=48) and (b) nonhomogeneous (n=52) image groups. We assessed the ISR images produced by OCT for tissue heterogeneity and neo-intimal hyperplasia using the normalized standard deviation of OCT signal-intensity (OCT-NSD) observed in neo-intimal hyperplasia tissue. In some patients with a nonhomogeneous OCT image, we collected pathological tissue. RESULTS: The prevalence of drug-eluting stents was 48% in the nonhomogeneous group and 29% in the homogeneous group (P=0.05). The OCT-NSD value in the nonhomogeneous group (0.223±0.019) was significantly higher than that in the homogeneous group (0.203±0.025; P<0.0001). Pathological tissue showed fibrin thrombi with infiltrating macrophage in 12 cases of nonhomogeneous ISR. The area under the receiver operating characteristic curve for the prediction of a nonhomogeneous image was 0.73 for OCT-NSD (95% confidence interval: 0.62-0.83: P<0.0001). The odds ratio for the prediction of a nonhomogeneous image was 3.47 (95% confidence interval: 1.18-10.2: P=0.02) for smoking by logistic regression analysis. CONCLUSION: Nonhomogeneous ISR visualized by OCT showed a high OCT-NSD value, which was a useful predictor for nonhomogeneous images. Moreover, the nonhomogeneous ISR image visualized by OCT may show chronic inflammation and fibrin thrombi.


Assuntos
Reestenose Coronária/patologia , Vasos Coronários/patologia , Stents Farmacológicos , Inflamação/patologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Tomografia de Coerência Óptica , Idoso , Área Sob a Curva , Biomarcadores/análise , Biópsia , Distribuição de Qui-Quadrado , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/metabolismo , Trombose Coronária/etiologia , Trombose Coronária/patologia , Vasos Coronários/química , Vasos Coronários/diagnóstico por imagem , Feminino , Fibrina/análise , Humanos , Hiperplasia , Imuno-Histoquímica , Inflamação/diagnóstico por imagem , Inflamação/etiologia , Inflamação/metabolismo , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Neointima , Variações Dependentes do Observador , Razão de Chances , Valor Preditivo dos Testes , Desenho de Prótese , Curva ROC , Reprodutibilidade dos Testes , Fatores de Risco , Fumar/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...