Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Fluids (1994) ; 33(8): 087118, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34552314

RESUMO

The COVID-19 pandemic has led to many countries oscillating between various states of lock-down as they seek to balance keeping the economy and essential services running and minimizing the risk of further transmission. Decisions are made about which activities to keep open across a range of social settings and venues guided only by ad hoc heuristics regarding social distancing and personal hygiene. Hence, we propose the dual use of computational fluid dynamic simulations and surrogate aerosol measurements for location-specific assessment of risk of infection across different real-world settings. We propose a 3-tiered risk assessment scheme to facilitate classification of scenarios into risk levels based on simulations and experiments. Threshold values of <54 and >840 viral copies and <5% and >40% of original aerosol concentration are chosen to stratify low, medium, and high risk. This can help prioritize allowable activities and guide implementation of phased lockdowns or re-opening. Using a public bus in Singapore as a case study, we evaluate the relative risk of infection across scenarios such as different activities and passenger positions and demonstrate the effectiveness of our risk assessment methodology as a simple and easily interpretable framework. For example, this study revealed that the bus's air-conditioning greatly influences dispersion and increases the risk of certain seats and that talking can result in similar relative risk to coughing for passengers around an infected person. Both numerical and experimental approaches show similar relative risk levels with a Spearman's correlation coefficient of 0.74 despite differing observables, demonstrating applicability of this risk assessment methodology to other scenarios.

2.
Research (Wash D C) ; 2021: 2173642, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33655212

RESUMO

Small-sized droplets/aerosol transmission is one of the factors responsible for the spread of COVID-19, in addition to large droplets and surface contamination (fomites). While large droplets and surface contamination can be relatively easier to deal with (i.e., using mask and proper hygiene measures), aerosol presents a different challenge due to their ability to remain airborne for a long time. This calls for mitigation solutions that can rapidly eliminate the airborne aerosol. Pre-COVID-19, air ionizers have been touted as effective tools to eliminate small particulates. In this work, we sought to evaluate the efficacy of a novel plant-based ionizer in eliminating aerosol. It was found that factors such as the ion concentration, humidity, and ventilation can drastically affect the efficacy of aerosol removal. The aerosol removal rate was quantified in terms of ACH (air changes per hour) and CADR- (clean air delivery rate-) equivalent unit, with ACH as high as 12 and CADR as high as 141 ft3/minute being achieved by a plant-based ionizer in a small isolated room. This work provides an important and timely guidance on the effective deployment of ionizers in minimizing the risk of COVID-19 spread via airborne aerosol, especially in a poorly-ventilated environment.

3.
Sci Rep ; 11(1): 4617, 2021 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-33633316

RESUMO

The Covid-19 pandemic has focused attention on airborne transmission of viruses. Using realistic air flow simulation, we model droplet dispersion from coughing and study the transmission risk related to SARS-CoV-2. Although this model defines most airborne droplets as 8-16 µm in diameter, we infer that larger droplets of 32-40 µm in diameter may potentially be more infectious due to higher viral content. Use of face masks is therefore recommended for both personal and social protection. We found social distancing effective at reducing transmission potential across all droplet sizes. However, the presence of a human body 1 m away modifies the aerodynamics so that downstream droplet dispersion is enhanced, which has implications on safe distancing in queues. At 1 m distance, we found that an average of 0.55 viral copies is inhaled for a cough at median loading, scalable up to 340 copies at peak loading. Droplet evaporation results in significant reduction in droplet counts, but airborne transmission remains possible even under low humidity conditions.


Assuntos
Microbiologia do Ar , COVID-19/transmissão , Tosse/virologia , SARS-CoV-2/fisiologia , Humanos , Hidrodinâmica , Máscaras , Modelos Biológicos , Tamanho da Partícula , Medição de Risco
4.
Biotechnol Bioeng ; 118(1): 305-318, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32946111

RESUMO

Due to sustainability concerns, bio-based production capitalizing on microbes as cell factories is in demand to synthesize valuable products. Nevertheless, the nonhomogenous variations of the extracellular environment in bioprocesses often challenge the biomass growth and the bioproduction yield. To enable a more rational bioprocess optimization, we have established a model-driven approach that systematically integrates experiments with modeling, executed from flask to bioreactor scale, and using ferulic acid to vanillin bioconversion as a case study. The impacts of mass transfer and aeration on the biomass growth and bioproduction performances were examined using minimal small-scale experiments. An integrated model coupling the cell factory kinetics with the three-dimensional computational hydrodynamics of bioreactor was developed to better capture the spatiotemporal distributions of bioproduction. Full-factorial predictions were then performed to identify the desired operating conditions. A bioconversion yield of 94% was achieved, which is one of the highest for recombinant Escherichia coli using ferulic acid as the precursor.


Assuntos
Benzaldeídos/metabolismo , Biomassa , Reatores Biológicos , Ácidos Cumáricos/metabolismo , Escherichia coli , Escherichia coli/genética , Escherichia coli/crescimento & desenvolvimento
5.
Phys Fluids (1994) ; 32(11): 113301, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-33244215

RESUMO

The ongoing Covid-19 pandemic has focused our attention on airborne droplet transmission. In this study, we simulate the dispersion of cough droplets in a tropical outdoor environment, accounting for the effects of non-volatile components on droplet evaporation. The effects of relative humidity, wind speed, and social distancing on evaporative droplet transport are investigated. Transmission risks are evaluated based on SARS-CoV-2 viral deposition on a person standing 1 m or 2 m away from the cougher. Our results show that the travel distance for a 100 µm droplet can be up to 6.6 m under a wind speed of 2 m/s. This can be further increased under dry conditions. We found that the travel distance of a small droplet is relatively insensitive to relative humidity. For a millimetric droplet, the projected distance can be more than 1 m, even in still air. Significantly greater droplets and viral deposition are found on a body 1 m away from a cougher, compared to 2 m. Despite low inhalation exposure based on a single cough, infection risks may still manifest through successive coughs or higher viral loadings.

6.
Biomed Res Int ; 2014: 514729, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24987691

RESUMO

Fractional flow reserve (FFR) is the gold standard to guide coronary interventions. However it can only be obtained via invasive angiography. The objective of this study is to propose a noninvasive method to determine FFRCT by combining computed tomography angiographic (CTA) images and computational fluid dynamics (CFD) technique. Utilizing the method, this study explored the effects of diameter stenosis (DS), stenosis length, and location on FFRCT. The baseline left anterior descending (LAD) model was reconstructed from CTA of a healthy porcine heart. A series of models were created by adding an idealized stenosis (with DS from 45% to 75%, stenosis length from 4 mm to 16 mm, and at 4 locations separately). Through numerical simulations, it was found that FFRCT decreased (from 0.89 to 0.74), when DS increased (from 45% to 75%). Similarly, FFRCT decreased with the increase of stenosis length and the stenosis located at proximal position had lower FFRCT than that at distal position. These findings are consistent with clinical observations. Applying the same method on two patients' CTA images yielded FFRCT close to the FFR values obtained via invasive angiography. The proposed noninvasive computation of FFRCT is promising for clinical diagnosis of CAD.


Assuntos
Circulação Coronária , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Modelos Cardiovasculares , Miocárdio , Animais , Velocidade do Fluxo Sanguíneo , Estenose Coronária/patologia , Vasos Coronários/patologia , Humanos , Suínos
7.
Biotechnol Prog ; 29(4): 1002-12, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23554399

RESUMO

A myriad of bioreactor configurations have been investigated as extracorporeal medical support systems for temporary replacement of vital organ functions. In recent years, studies have demonstrated that the rotating bioreactors have the potential to be utilized as bioartificial liver assist devices (BLADs) owing to their advantage of ease of scalability of cell-culture volume. However, the fluid movement in the rotating chamber will expose the suspended cells to unwanted flow structures with abnormally high shear conditions that may result in poor cell stability and in turn lower the efficacy of the bioreactor system. In this study, we compared the hydrodynamic performance of our modified rotating bioreactor design with that of an existing rotating bioreactor design. Computational fluid dynamic analysis coupled with experimental results were employed in the optimization process for the development of the modified bioreactor design. Our simulation results showed that the modified bioreactor had lower fluid induced shear stresses and more uniform flow conditions within its rotating chamber than the conventional design. Experimental results revealed that the cells within the modified bioreactor also exhibited better cell-carrier attachment, higher metabolic activity, and cell viability compared to those in the conventional design. In conclusion, this study was able to provide important insights into the flow physics within the rotating bioreactors, and help enhanced the hydrodynamic performance of an existing rotating bioreactor for BLAD applications.


Assuntos
Técnicas de Cultura de Células , Simulação por Computador , Hidrodinâmica , Reatores Biológicos , Técnicas de Cultura de Células/instrumentação , Sobrevivência Celular , Humanos , Rotação , Células Tumorais Cultivadas
8.
Phys Rev E Stat Nonlin Soft Matter Phys ; 81(6 Pt 2): 066308, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20866523

RESUMO

The dynamics of a Taylor bubble rising in stagnant liquids is numerically investigated using a front tracking coupled with finite difference method. Parametric studies on the dynamics of the rising Taylor bubble including the final shape, the Reynolds number (Re(T)), the Weber number (We(T)), the Froude number (Fr), the thin liquid film thickness (w/D), and the wake length (l(w)/D) are carried out. The effects of density ratio (η), viscosity ratio (λ), Eötvös number (Eo), and Archimedes number (Ar) are examined. The simulations demonstrate that the density ratio and the viscosity ratio under consideration have minimal effect on the dynamics of the Taylor bubble. Eötvös number and Archimedes number influence the elongation of the tail and the wake structures, where higher Eo and Ar result in longer wake. To explain the sudden extension of the tail, a Weber number (We(l)) based on local curvature and velocity is evaluated and a critical We(l) is detected around unity. The onset of flow separation at the wake occurs in between Ar=2×10(3) and Ar=1×10(4), which corresponds to Re(T) between 13.39 and 32.55. Archimedes number also drastically affects the final shape of Taylor bubble, the terminal velocity, the thickness of thin liquid film, as well as the wall shear stress. It is found that w/D=0.32 Ar(-0.1).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...