Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Omega ; 4(11): 14599-14604, 2019 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-31528814

RESUMO

The handcrafted fabrication of a pyramidal mold on a silicon wafer for nanopatterning was investigated. This process started with the manual delivery of an aqueous glycerol solution onto the SiO2/Si wafer using a micropipette and subsequent drying to form a hemisphere whose diameter is in the range of hundreds of micrometers. A coating of polystyrene (PS) onto this wafer generates a circular hole caused by dewetting. Subsequently, anisotropic wet-etching with the PS film as a mask produces a pyramidal trench, whose apex approaches hundreds of nanometers. Various elastomeric materials were casted into this pyramidal mold. A pyramidal tip mounted on a simple micropositioner was used for electrochemistry and patterning of a protein. First, an agarose hydrogel was cast with a hydrogel pen for the electrochemical reaction (HYPER). The redox reaction at the HYPER-electrode interface demonstrated the characteristics of an ultramicroelectrode or bulk electrode based on the contact area. Second, the pyramidal polydimethylsiloxane served as a polymer pen for the contact printing of silane on a glass substrate. After the successive immobilization of biotin and avidin with fluorescence labeling, the resulting fluorescence image demonstrated the successful patterning of the protein. This new process for the creation of a pyramidal mold, referred to as a "do-it-yourself" process, offers advantages to nonspecialists in nanotechnology compared to conventional lithography, specifically simplicity, rapidity, and low cost.

2.
Adv Sci (Weinh) ; 4(8): 1600502, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28852613

RESUMO

It has been challenging to find stable blue organic light emitting diodes (OLEDs) that rely on thermally activated delayed fluorescence (TADF). Lack of stable host materials well-fitted to the TADF emitters is one of the critical reasons. The most popular host for blue TADF, bis[2-(diphenylphosphino)phenyl] ether oxide (DPEPO), leads to unrealistically high maximum external quantum efficiency. DPEPO is however an unstable material and has a poor charge transporting ability, which in turn induces an intrinsic short OLED operating lifespan. Here, an alternative host material is introduced which educes the potential efficiency and device lifespan of given TADF emitters with the appropriateness of replacing the most popular host material, DPEPO, in developing blue TADF emitters. It simultaneously provides much longer device lifespan and higher external quantum efficiency at a practical brightness due to its high material stability and electron-transport-type character well-fitted for hole-transport-type TADF emitters.

3.
Nat Mater ; 15(10): 1120-7, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27500805

RESUMO

Virtual screening is becoming a ground-breaking tool for molecular discovery due to the exponential growth of available computer time and constant improvement of simulation and machine learning techniques. We report an integrated organic functional material design process that incorporates theoretical insight, quantum chemistry, cheminformatics, machine learning, industrial expertise, organic synthesis, molecular characterization, device fabrication and optoelectronic testing. After exploring a search space of 1.6 million molecules and screening over 400,000 of them using time-dependent density functional theory, we identified thousands of promising novel organic light-emitting diode molecules across the visible spectrum. Our team collaboratively selected the best candidates from this set. The experimentally determined external quantum efficiencies for these synthesized candidates were as large as 22%.

4.
Nanoscale ; 7(3): 994-1001, 2015 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-25469501

RESUMO

A hydrogel pen consisting of a microscopic pyramid containing an electrolyte offers a localized electroactive area on the nanometer scale via controlled contact of the apex with a working electrode. The hydrogel pen merges the fine control of atomic force microscopy with non-linear diffusion of an ultramicroelectrode, producing a faradaic current that depends on the small electroactive area. The theoretical and experimental investigations of the mass transport behavior within the hydrogel reveal that the steady-state current from the faradaic reaction is linearly proportional to the deformed length of the hydrogel pen by contact, i.e. signal transduction of deformation to an electrochemical signal, which enables the fine control of the electroactive area in the nanometer-scale regime. Combined with electrodeposition, localized electrochemistry of the hydrogel pen results in the ability to fabricate small sizes (110 nm in diameter), tall heights (up to 30 µm), and arbitrary structures, thereby indicating an additive process in 3 dimensions by localized electrodeposition.

5.
ACS Nano ; 8(8): 8182-9, 2014 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-25112683

RESUMO

Size reduction of neural electrodes is essential for improving the functionality of neuroprosthetic devices, developing potent therapies for neurological and neurodegenerative diseases, and long-term brain­computer interfaces. Typical neural electrodes are micromanufactured devices with dimensions ranging from tens to hundreds of micrometers. Their further miniaturization is necessary to reduce local tissue damage and chronic immunological reactions of the brain. Here we report the neural electrode with subcellular dimensions based on single-crystalline gold nanowires (NWs) with a diameter of ∼100 nm. Unique mechanical and electrical properties of defect-free gold NWs enabled their implantation and recording of single neuron-activities in a live mouse brain despite a ∼50× reduction of the size compared to the closest analogues. Reduction of electrode dimensions enabled recording of neural activity with improved spatial resolution and differentiation of brain activity in response to different social situations for mice. The successful localization of the epileptic seizure center was also achieved using a multielectrode probe as a demonstration of the diagnostics potential of NW electrodes. This study demonstrated the realism of single-neuron recording using subcellular-sized electrodes that may be considered a pivotal point for use in diverse studies of chronic brain diseases.


Assuntos
Encéfalo/citologia , Ouro/química , Espaço Intracelular/metabolismo , Sondas Moleculares/química , Sondas Moleculares/metabolismo , Nanofios , Animais , Interfaces Cérebro-Computador , Eletrodos Implantados , Masculino , Camundongos , Camundongos Endogâmicos C57BL
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...