Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Environ Sci Pollut Res Int ; 30(35): 84814-84821, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37353703

RESUMO

In bird species, anthropogenic nesting materials have been known to have a negative effect on the survival of birds in general, but in some species, these can be used instead of natural materials, which can have a positive effect on the structural aspects of nests. Our study aims to investigate the type and amount of anthropogenic materials found in the nests of the colonial breeding azure-winged magpie (Cyanopica cyanus) in an agricultural area, as well as the characteristics of these used for each nest structure. We found that plastic litter was used in all of the azure-winged magpie breeding nests observed, and the types and amounts of plastic litter used differed between the cup and the outer. In all nests, soft, elastic, and insulating materials such as polyester fiber were mainly observed in the cup, and strings that weave and anchor branches and soil from nature were mostly found in the outer. The amount of plastic litter used in nests was related to the size of the nest. Plastic litter used in nests is thought to be collected from agricultural materials used in agricultural lands, vinyl greenhouses, and agricultural warehouses in our study site. Consequently, we expect that the phenomenon of azure-winged magpies using plastic litters for nest building may be common situation for the current agricultural environment where plastics are widespread.


Assuntos
Passeriformes , Animais , República da Coreia , Solo
2.
Medicina (Kaunas) ; 59(4)2023 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-37109740

RESUMO

Background: prosthetic loosening after hip and knee arthroplasty is one of the most common causes of joint arthroplasty failure and revision surgery. Diagnosis of prosthetic loosening is a difficult problem and, in many cases, loosening is not clearly diagnosed until accurately confirmed during surgery. The purpose of this study is to conduct a systematic review and meta-analysis to demonstrate the analysis and performance of machine learning in diagnosing prosthetic loosening after total hip arthroplasty (THA) and total knee arthroplasty (TKA). Materials and Methods: three comprehensive databases, including MEDLINE, EMBASE, and the Cochrane Library, were searched for studies that evaluated the detection accuracy of loosening around arthroplasty implants using machine learning. Data extraction, risk of bias assessment, and meta-analysis were performed. Results: five studies were included in the meta-analysis. All studies were retrospective studies. In total, data from 2013 patients with 3236 images were assessed; these data involved 2442 cases (75.5%) with THAs and 794 cases (24.5%) with TKAs. The most common and best-performing machine learning algorithm was DenseNet. In one study, a novel stacking approach using a random forest showed similar performance to DenseNet. The pooled sensitivity across studies was 0.92 (95% CI 0.84-0.97), the pooled specificity was 0.95 (95% CI 0.93-0.96), and the pooled diagnostic odds ratio was 194.09 (95% CI 61.60-611.57). The I2 statistics for sensitivity and specificity were 96% and 62%, respectively, showing that there was significant heterogeneity. The summary receiver operating characteristics curve indicated the sensitivity and specificity, as did the prediction regions, with an AUC of 0.9853. Conclusions: the performance of machine learning using plain radiography showed promising results with good accuracy, sensitivity, and specificity in the detection of loosening around THAs and TKAs. Machine learning can be incorporated into prosthetic loosening screening programs.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Estudos Retrospectivos , Falha de Prótese , Artroplastia de Quadril/efeitos adversos , Aprendizado de Máquina , Reoperação
3.
J Prosthet Dent ; 2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37121851

RESUMO

STATEMENT OF PROBLEM: Different 3D printers are available for guided implant surgery, but studies that evaluate their source of errors and their cost-effectiveness are lacking. PURPOSE: The purpose of this in vitro study was to compare the accuracy of different 3-dimensional (3D) printed surgical templates made using different additive manufacturing technologies and to evaluate the effect of implant location on the accuracy of fully guided implant placement. MATERIAL AND METHODS: Fifty partially edentulous maxillary typodonts with edentulous sites in the right second premolar (SP), right lateral incisor (LI), left central incisor (CI), and left first molar (FM) locations were scanned and printed from the standard tessellation language (STL) datasets. The study compared 5 groups for the fabrication of implant surgical templates: Varseo S-Bego (Bego), Polyjet-Stratasys (Poly), Low Force Stereolithography-FormLabs (LFS), P30+-Straumann (P30), and M2-Carbon (M2). After fully guided implant placement, the typodont was scanned, and the 3D implant positions were compared with the master model by superimposing the STL files. Descriptive statistics were calculated for groups and subgroups, and comparisons among the groups and subgroups were conducted via 2-way mixed analysis of variance, Tukey honest significant difference, and post hoc Bonferroni tests (α=.05). RESULTS: The results were site specific and not consistent within each group. For angle deviation, the within-group analysis for P30 demonstrated significantly lower values for implants positioned at site SP (1.4 ±0.8 degrees) than for sites LI (2.3 ±0.7 degrees; P=.001) and CI (2.3 ±0.8 degrees; P=.007). For 3D offset at base for implant CI, LFS was significantly higher than Bego (P=.002), Poly (P=.035), or M2 (P=.001); P30 was also significantly higher than Bego (P=.014) and M2 (P=.006). LFS had a significantly higher 3D offset at the tip than Bego (P=.001) and M2 (P=.022) for implant CI. CONCLUSIONS: The choice of 3D printer seemed to influence fully guided implant surgery in terms of the final implant position compared with initial implant planning. However, although statistically significant differences were present across groups, all additive manufacturing technologies were within clinically acceptable values.

4.
Medicina (Kaunas) ; 58(12)2022 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-36556954

RESUMO

Background and Objectives: Studies have shown that centrally sensitized patients have worse clinical outcomes following total knee arthroplasty (TKA) than non-centrally sensitized patients. It is unclear whether central sensitization (CS) affects patient-reported outcomes (PROs) and/or level of osteotomy site pain in patients undergoing medial opening-wedge high tibial osteotomy (MOWHTO). The purpose of this study was to determine whether CS is associated with PROs and osteotomy site pain following MOWHTO. Materials and Methods: A retrospective evaluation was conducted on 140 patients with varus knee osteoarthritis (OA) who were treated with MOWHTO and monitored for two years. Before surgery, the Central Sensitization Inventory (CSI) was used to assess CS status, and a CSI of 40 or higher was considered indicative of CS. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and pain visual analogue scale (VAS) were used to assess PROs. The minimal clinically important difference (MCID) for the WOMAC was set as 4.2 for the pain subscore, 1.9 for the stiffness subscore, 10.1 for the function subscore, and 16.1 for the total based on the results of a previous study. The WOMAC score, pain VAS score of the osteotomy site, and the achievement rates of WOMAC MCID were compared between the CS and non-CS groups. Results: Thirty-seven patients were assigned to the CS group, whereas 84 were assigned to the non-CS group. Before surgery, the CS group showed a higher WOMAC score than the non-CS group (58.7 vs. 49.4, p < 0.05). While there was a statistically significant improvement in WOMAC subscores (pain, stiffness, function, and total) for both groups at two years after surgery (all p < 0.05), the CS group had a higher WOMAC score than the non-CS group (37.1 vs. 21.8, p < 0.05). The CS group showed significantly inferior results in pre- and postoperative changes of WOMAC subscores (pain, function, and total) relative to the non-CS group (all p < 0.05). In addition, pain at the osteotomy site was more severe in the CS group than in the non-CS group at two years after surgery (4.8 vs. 2.2, p < 0.05). Patients with CS had worse MCID achievement rates across the board for WOMAC pain, function, and total scores (all p < 0.05) compared to the non-CS group. Conclusions: Centrally sensitized patients following MOWHTO had worse PROs and more severe osteotomy site pain compared to non-centrally sensitized patients. Furthermore, the WOMAC MCID achievement rate of patients with CS was lower than that of patients without CS. Therefore, appropriate preoperative counseling and perioperative pain management are necessary for patients with CS undergoing MOWHTO. Level of Evidence: Level III, case-control study.


Assuntos
Articulação do Joelho , Osteoartrite do Joelho , Humanos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/complicações , Osteoartrite do Joelho/cirurgia , Estudos Retrospectivos , Estudos de Casos e Controles , Sensibilização do Sistema Nervoso Central , Tíbia/cirurgia , Dor/etiologia , Osteotomia/efeitos adversos , Osteotomia/métodos , Medidas de Resultados Relatados pelo Paciente , Resultado do Tratamento
5.
PeerJ ; 10: e13637, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35789658

RESUMO

Bird nests are crucial for reproductive success since they serve as structures to hold the eggs and nestlings safely. Therefore, the structural characteristics of bird nests have optimally evolved to maximize reproductive success, which are known to be affected by various factors. We gathered information on the nest characteristics such as nest structure and constituent materials in the colonial breeding Azure-winged magpie (Cyanopica cyanus) and investigated the relationship between ecologically relevant factors and the size and mass of the nests. The Azure-winged magpie nest can be deconstructed into an outer nest and an inner cup, and the type and mass of materials used for the construction of each part varies. Compared to the inner cup, the outer nest, which constitutes the overall shape of the nest, is composed of relatively harder materials, such as branches and soil. In contrast, the inner cup, which is the part where birds directly incubate eggs and raise nestlings, is composed of more flexible and softer materials, such as fiber and moss. We found that there was no relationship between nest characteristics and ecologically relevant factors. However, as the breeding season progressed, the volume of the inner cup decreased with increasing ambient temperatures. Our results show that Azure-winged magpies use differing materials for structurally distinct parts of the nests during construction. The results also indirectly suggest that the choice regarding the amount of insulating materials relative to changing temperatures during the breeding season may be one of the more significant adaptive strategies in the nest-building behaviors of Azure-winged magpies.


Assuntos
Comportamento de Nidação , Passeriformes , Animais , Melhoramento Vegetal , Reprodução , República da Coreia
6.
J Prosthet Dent ; 128(1): 79-88, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33546857

RESUMO

STATEMENT OF PROBLEM: The properties of dental computer-aided design and computer-aided manufacturing (CAD-CAM) materials vary. Studies regarding the effects of aging on the properties of these materials are lacking. PURPOSE: The purpose of this in vitro study was to evaluate the changes in the mechanical and surface properties of different CAD-CAM materials after thermocycling and mechanical loading. MATERIAL AND METHODS: In total, 150 bar-shaped specimens (17.0×4.0×2.0 mm) were prepared from feldspathic glass-ceramic (VM; Vitablocs Mark II), lithium disilicate glass-ceramic (EX; IPS e.max CAD), zirconia-reinforced lithium silicate glass-ceramic (CD; Celtra Duo), polymer-infiltrated ceramic network (VE; Vita Enamic), and resin-nanoceramic (CS; Cerasmart). Each type was divided into 2 groups (n=15; each). One group was subjected to thermocycling in distilled water at 5 °C to 55 °C for 6000 cycles and 50 N mechanical loading for 1.2×106 cycles. The other group was stored in 37 °C water for 24 hours. Nanoindentation hardness, Young modulus, and 3-point flexural strength were measured for the analyses of the mechanical properties. Surface roughness, surface microstructure, and elemental composition were measured to analyze the surface characteristics. Statistical analyses were performed with 1-way ANOVA with the Tukey HSD post hoc test, independent samples t test, Kruskal-Wallis test with Bonferroni post hoc test, Mann-Whitney U test, and 2-way ANOVA (α=.05). RESULTS: Before and after aging, CS exhibited the lowest hardness (1.20 to 1.04 GPa) and Young modulus (13.76 to 13.48 GPa) values (P<.05). EX exhibited the highest flexural strengths (393.43 to 391.86 MPa), and VM exhibited the lowest (109.98 to 112.73 MPa) values (P<.05). CS exhibited the highest surface roughness (Sa and Sq; 10.60 to 28.82, 14.21 to 38.27 nm) values (P<.05). After aging, the hardness and Young modulus of VM, EX, and VE decreased significantly (P<.001). No significant difference was observed in the flexural strengths of the CAD-CAM materials (P>.05). Significant increases were observed in the surface roughness of all the materials (P<.05), with altered microstructures. Except for the flexural strength, the mechanical properties and surface characteristics of the CAD-CAM materials were significantly affected by the material type after aging. CONCLUSIONS: Before and after aging, resin-nanoceramic exhibited the lowest hardness and Young modulus, and the highest surface roughness. Lithium disilicate glass-ceramic exhibited the highest flexural strength and feldspathic glass-ceramic exhibited the lowest value. After aging, increased surface roughness and microstructure alterations were observed. Significant interactions between aging process and material type were found for the mechanical properties and surface characteristics except for the flexural strength.


Assuntos
Cerâmica , Porcelana Dentária , Cerâmica/química , Desenho Assistido por Computador , Materiais Dentários/química , Resistência à Flexão , Dureza , Teste de Materiais , Propriedades de Superfície , Água
7.
J Oral Implantol ; 48(5): 351-357, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34937081

RESUMO

The aims of this study were to evaluate the effect of (1) the different surgical guide designs and (2) implant placement location on the accuracy of fully guided implant placement in single edentulous sites using an in vitro study model. Forty-five partially edentulous models were scanned and divided into 3 groups: group 1, tooth-supported full-arch surgical guide; group 2, 3 different tooth-supported shortened surgical guides (SSGs); and group 3, tooth-supported full-arch surgical guide with a crossbar. All surgical guides were printed and used for fully guided implant placement. A total of 180 implants (60 per group) were placed, and scan bodies were positioned on all models, and postoperative surface scan files (STL) files were obtained. Superimposition of preoperative and postoperative STL files was performed, and the accuracy of implant position was evaluated. The interaction between group and implant location was statistically significant for angle, 3D offset at the base, and at the tip (P < .001). The post-hoc tests showed a statistically significantly higher deviation for group 2 compared to group 3 for all outcomes for implants #4 (P < .05) and #7 (P < .05). There was also a statistically significant difference in all outcomes between groups 1 and 3 for implant #7 (P < .05). All surgical guide designs presented satisfactory performance with clinically acceptable levels of deviation. However, SSGs presented higher accuracy for guided implant placement in a single-edentulous site, whereas a full-arch surgical guide with a crossbar presented superior outcomes when 2 or more guided implants were placed simultaneously.


Assuntos
Implantes Dentários , Boca Edêntula , Cirurgia Assistida por Computador , Humanos , Implantação Dentária Endóssea , Tomografia Computadorizada de Feixe Cônico , Desenho Assistido por Computador , Imageamento Tridimensional , Computadores
8.
J Prosthodont ; 30(6): 548-552, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33811713

RESUMO

The aim of this clinical report is to describe a complete digital workflow protocol for mandibular full-arch implant rehabilitation from guided surgery to definitive prosthesis in only 3 appointments. This expedited protocol allows for guided implant placement with a system of stackable surgical templates and CAD/CAM prosthodontic rehabilitation using a digital workflow. At the first appointment, a guided implant placement protocol with the stackable template concept was done followed by immediate loading with a prefabricated interim prosthesis. At the same appointment, the Double Digital Scanning (DDS) technique was used for scanning, maxillomandibular relationship registration and virtual articulation. The anchor pins from guided surgery were used as fiducial markers for DDS data superimposition. At the second appointment, the prosthesis prototype was tried-in and adjustments were made. At the third appointment, the definitive monolithic zirconia full-arch prosthesis was delivered.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Desenho Assistido por Computador , Planejamento de Prótese Dentária , Implantação de Prótese , Fluxo de Trabalho
9.
J Prosthet Dent ; 126(5): 608-615, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33160619

RESUMO

This clinical report describes a ceramic complete-mouth rehabilitation with screw-retained implant abutment crowns, optimizing esthetics by combining the properties of ceramic materials. The abutments connected a titanium insert to a computer-aided design and computer-aided manufacturing (CAD-CAM) monolithic zirconia framework, offering improved esthetics and biologic response without negatively affecting the implant abutment interface. Lithium disilicate crowns were cemented extraorally on the abutments, resulting in a screw-retained restoration.


Assuntos
Implantes Dentários , Falha de Restauração Dentária , Parafusos Ósseos , Desenho Assistido por Computador , Coroas , Dente Suporte , Projeto do Implante Dentário-Pivô , Estética Dentária , Seguimentos , Teste de Materiais , Titânio , Zircônio
10.
J Prosthet Dent ; 126(5): 679-685, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33041076

RESUMO

STATEMENT OF PROBLEM: The optical properties of esthetic computer-aided design and computer-aided manufacturing (CAD-CAM) materials can change depending on the clinical situation. Studies that compare esthetic CAD-CAM materials based on their optical properties are lacking. PURPOSE: The purpose of this in vitro study was to evaluate the optical properties of esthetic CAD-CAM specimens after ultraviolet (UV) aging based on the type and thickness of the material. MATERIAL AND METHODS: In total, 240 plate-shaped specimens (14×12×1 mm and 14×12×2 mm) of a nanohybrid composite resin (Tetric CAD), a fine-structure feldspathic ceramic (Vitablocs Mark II), 2 different glass-ceramics (IPS Empress CAD and IPS e.max CAD), a zirconia-reinforced lithium silicate glass-ceramic (Celtra Duo), a polymer-infiltrated ceramic network (Vita Enamic), and 2 different resin nanoceramics (Cerasmart and Lava Ultimate) were fabricated (n=15). The optical parameters were analyzed by spectrophotometry before and after UV aging. The brightness (L∗), red green (a∗), yellow-blue (b∗), chroma (Ch), and hue (h) were measured, and the color difference (ΔE00) values were calculated. The translucency parameter (TP), total transmittance (Tt), and contrast ratio (CR) were also determined. Statistical analyses were performed with 1-way ANOVA, the Tukey honestly significant difference post hoc test, independent- and paired-samples t tests, and 2-way ANOVA (α=.05). RESULTS: Significant interactions were observed for the aging process, material type, and thickness for all optical parameters (P<.05). L∗, TP, and Tt had lower values, while CR had higher values for the aging group than that of the control group (P<.05). The h, TP, and Tt values were higher, whereas the b∗ and CR values were lower for the 1-mm group than those of the 2-mm group (P<.05). The highest ΔE00 value was found in the Lava Ultimate 1-mm group (ΔE00=3.21) and 2-mm group (ΔE00=2.42). The lowest ΔE00 value was found in the Vitablocs Mark II 1-mm group (ΔE00=0.31). The highest TP and Tt and the lowest CR values were observed for Tetric CAD; the lowest TP and Tt, and the highest CR values were noted in Celtra Duo (P<.05). CONCLUSIONS: The optical properties of the CAD-CAM specimens were affected by the aging process, material type, and thickness, and the color stability was clinically applicable in all CAD-CAM materials except groups Lava Ultimate and Cerasmart(ΔE00<2.25). Resin nanoceramics exhibited the greatest color changes after UV aging, and a 2-mm thickness is recommended to ensure acceptable color stability. The zirconia-reinforced lithium silicate glass-ceramic was the most opaque, with a 1-mm thickness providing increased translucency.


Assuntos
Porcelana Dentária , Estética Dentária , Cerâmica , Cor , Desenho Assistido por Computador , Materiais Dentários , Teste de Materiais , Propriedades de Superfície
11.
Compend Contin Educ Dent ; 41(9): e5-e9, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33001661

RESUMO

This article describes the case of a partially edentulous patient who had undergone template-guided implant placement and was treated using a triple digital scanning protocol that allowed for CAD/CAM prosthodontic rehabilitation in a complete digital workflow. At the impression appointment, the provisional implant-supported screw-retained prosthesis was digitally scanned both intraorally (first scan) and, after removal, extraorally (second scan). After the second scan, scan bodies were placed intraorally and an implant-level digital impression was taken (third scan). The three standard tessellation language (STL) files derived from the three digital scans were imported in a CAD software and superimposed into one file that contained all of the information from the implant 3D position, prosthesis contours, and transmucosal part of the peri-implant soft tissues. The superimposition of the three STL files led to one master file to serve as a blueprint for the definitive prosthesis. The definitive monolithic zirconia prosthesis was CAM copy-milled, externally stained, and inserted. The patient was satisfied with both the esthetic and functional outcome and the minimally invasive, time-efficient, two-visit restorative protocol. In summary, this case report illustrates a technique for a complete digital workflow in an implant rehabilitation for the replacement of multiple missing teeth in the esthetic zone in two visits.


Assuntos
Implantes Dentários , Fluxo de Trabalho , Desenho Assistido por Computador , Prótese Dentária Fixada por Implante , Estética Dentária , Humanos
12.
Orthop J Sports Med ; 8(9): 2325967120947414, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32964060

RESUMO

BACKGROUND: Retearing of a repaired rotator cuff leads to diverse symptoms, including pain, regardless of the degree of the tear, but the relationship between pain and retears is poorly understood. PURPOSE: To determine which factors are correlated with shoulder pain in retears of a repaired rotator cuff. STUDY DESIGN: Case-control study; Level of evidence, 3. METHODS: We retrospectively reviewed a cohort of patients who were diagnosed as having a retear on magnetic resonance imaging after primary rotator cuff repair. The primary outcome variable of interest was the visual analog scale (VAS) for pain score at 12-month and final follow-up (mean, 25.2 months). We evaluated the relationship of pain at 12-month and final follow-up with preoperative patient factors (age, sex, and underlying conditions), preoperative range of motion, and preoperative pain; postoperative pain at 3 and 6 months; and perioperative conditions (tear extent, tear size, accompanying lesions, and procedures other than rotator cuff repair). RESULTS: A total of 48 patients were reviewed. The VAS score at 3 months postoperatively showed a positive correlation with the VAS score at 12 months postoperatively (ρ = 0.537; P < .001) and at final follow-up (ρ = 0.537; P < .001). Univariate and multivariate regression analyses revealed that the VAS score at 3 months postoperatively (P = .0001 and P = .0017, respectively), hypertension (P = .0108 and P = .0073, respectively), and late detection of the retear (P = .0091 and P = .0208, respectively) were significant predictors of pain at 12 months postoperatively. CONCLUSION: The presence of pain in the early postoperative period, underlying hypertension, and late detection of the retear were related to pain severity in patients 12 months after rotator cuff surgery.

14.
J Prosthodont ; 29(8): 660-678, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32613641

RESUMO

PURPOSE: To systematically review in vitro and clinical studies comparing quantitatively the 3D accuracy (global implant deviations) of digital vs conventional implant impressions for partially and completely edentulous patients. MATERIALS AND METHODS: Electronic and manual searches were conducted to identify in vitro and clinical studies, reporting on the 3D accuracy between digital and conventional implant impressions. Secondary outcomes were the effect of implant angulation, type of conventional impression technique, and type of intraoral scanner on the accuracy of implant impressions. RESULTS: The inclusion criteria were met by 9 in vitro studies and 1 clinical study reporting on completely edentulous impressions, while 6 in vitro and 2 clinical studies reported on partially edentulous impressions. Quantitative meta-analysis was performed for 5 completely edentulous and 6 partially edentulous studies. The studies exhibited high values for heterogeneity. A random effects model was conducted to estimate the effect size. Based on 5 in vitro studies on completely edentulous impressions, the mean 3D implant deviation between conventional and digital impressions was 8.20 µm (95% CI: -53.56, 37.15) and the digital impressions had nominally less deviation (p = 0.72). Based on 1 clinical and 5 in vitro studies on partially edentulous impressions, the mean 3D implant deviation between conventional and digital impressions was 52.31 µm (95% CI: 6.30, 98.33) and the conventional impressions had nominally less deviation (p = 0.03). Five in vitro and 2 clinical studies were not included in the quantitative analysis due to heterogeneity in the methodology. Implant angulation affected the accuracy in favor of the partially edentulous conventional impressions whereas the effect of different scanners was not statistically significant on the completely edentulous impressions (p = 0.82). CONCLUSIONS: Digital scans appear to have comparable 3D accuracy with conventional implant impressions based mainly on in vitro studies. However, clinical trials are recommended to investigate the clinical accuracy of digital scans and digitally fabricated interim or prototype prostheses, before digital implant scans can be recommended for routine clinical use.


Assuntos
Implantes Dentários , Boca Edêntula , Desenho Assistido por Computador , Materiais para Moldagem Odontológica , Técnica de Moldagem Odontológica , Humanos , Modelos Dentários
15.
J Prosthodont ; 29(6): 460-465, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32185825

RESUMO

The purpose of the present report is to illustrate a proof-of-concept protocol with the double digital scanning (DDS) technique for complete digital workflow in double full-arch implant rehabilitation. Two patients (4 restored arches) presented with hopeless dentitions and they were treated with a 4-appointment prosthodontic protocol and monolithic zirconia prostheses implementing a complete digital workflow. The outcomes are presented after clinical and radiographic observation for 2 years.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Desenho Assistido por Computador , Planejamento de Prótese Dentária , Humanos , Fluxo de Trabalho , Zircônio
16.
J Prosthet Dent ; 124(5): 589-593, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31959396

RESUMO

STATEMENT OF PROBLEM: Data on the accuracy of printed casts from complete-arch digital implant scans are lacking. PURPOSE: The purpose of this in vitro study was to compare the 3D accuracy of printed casts from a complete-arch digital implant intraoral scan with stone casts from conventional impressions. MATERIAL AND METHODS: An edentulous mandibular cast with 4 multiunit abutments with adequate anteroposterior spread was used as the master cast. Digital scans (n=25) were made by using a white light intraoral scanner (IOS). The generated standard tessellation language (STL) data sets were imported into a computer-assisted design (CAD) software program to generate complete-arch implant casts through 3D printing technology. The 25 printed casts and the mandibular master cast were further digitized by using a laboratory reference scanner (Activity 880; Smart Optics). These STL data sets were superimposed on the digitized master cast in a metrology software program (Geomagic Control X) for virtual analysis. The root mean square (RMS) error and the average offset were measured. RESULTS: When compared with the master cast, the printed casts had a mean ±standard deviation RMS error of 59 ±16 µm (95% CI: 53, 66). The maximum RMS error reached 98 µm. The average offsets were all negative, with a significant difference compared with zero (P<.001). CONCLUSIONS: The implant 3D deviations of the printed casts from complete-arch digital scans had statistically significant differences compared with those of the master cast but may still be within the acceptable range for clinical application.


Assuntos
Implantes Dentários , Técnica de Moldagem Odontológica , Desenho Assistido por Computador , Imageamento Tridimensional , Modelos Dentários , Impressão Tridimensional , Fluxo de Trabalho
17.
J Esthet Restor Dent ; 30(1): 5-13, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28792115

RESUMO

OBJECTIVE: To illustrate a digital workflow in full-arch implant rehabilitation with minimally veneered monolithic zirconia and to report the outcomes including technical complications. CLINICAL CONSIDERATIONS: Three patients (5 edentulous arches) received full-arch fixed implant rehabilitation with monolithic zirconia and mild facial porcelain veneering involving a digital workflow. The incisal edges and occluding surface areas were milled out of monolithic zirconia to reduce the possibility of chipping. Porcelain veneering was applied on the facial aspect to improve the esthetic result. Outcomes and technical complications are reported after 2 years of clinical and radiographic follow-up. CONCLUSION: Implant and prosthesis survival rates were 100% after a short-term follow-up of 2 years. Technical complications were encountered in one patient. They did not adversely affect prosthesis survival or patient satisfaction and were easily addressed. A digital workflow for the design and fabrication of full-arch monolithic zirconia implant fixed implant prostheses has benefits, but caution is necessary during CAD planning of the prosthesis to ensure a successful outcome. Long-term clinical studies are needed to corroborate the findings discussed in this report. CLINICAL SIGNIFICANCE: This article presents an integrated digital workflow that was implemented for the implant-prosthodontic rehabilitation of three edentulous patients with monolithic zirconia prostheses. Monolithic zirconia has been successfully incorporated in implant prosthodontics in an effort to reduce the technical complications associated with bilayered ceramics. This workflow simplifies design and fabrication of the zirconia prostheses. However, caution should be taken during CAD planning of the prosthesis to make sure the zirconia cylinder is sufficiently thick at the interface with the titanium insert. Additionally, when cutback is planned for facial porcelain veneering, the functional occluding cusps and incisal edges should be fabricated in monolithic zirconia to avoid chipping.


Assuntos
Porcelana Dentária , Prótese Dentária Fixada por Implante , Desenho Assistido por Computador , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Seguimentos , Humanos , Fluxo de Trabalho , Zircônio
18.
Clin Oral Implants Res ; 28(7): 849-863, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27350419

RESUMO

OBJECTIVE: To assess survival, as well as technical and biological complication rates of partial fixed dental prostheses (FDPs) supported by implants and teeth. METHOD: An electronic Medline search was conducted to identify articles, published in dental journals from January 1980 to August 2015, reporting on partial FDPs supported by implants and teeth. The search terms were categorized into four groups comprising the PICO question. Manual searches of published full-text articles and related reviews were also performed. RESULTS: The initial database search produced 3587 relevant titles. Three hundred and eighty-six articles were retrieved for abstract review, while 39 articles were selected for full-text review. A total of 10 studies were selected for inclusion. Overall survival rate for implants ranged between 90% and 100%, after follow-up periods with a mean range of 18-120 months. The survival of the abutment teeth was 94.1-100%, while the prostheses survival was 85-100% for the same time period. The most frequent complications were "periapical lesions" (11.53%). The most frequent technical complication was "porcelain occlusal fracture" (16.6%), followed by "screw loosening" (15%). According to the meta-analysis, no intrusion was noted on the rigid connection group, while five teeth (8.19%) were intruded in the non-rigid connection group [95% CI (0.013-0.151)]. CONCLUSION: The tooth-implant FDP seems to be a possible alternative to an implant-supported FDP. There is limited evidence that rigid connection between teeth and implants presents better results when compared with the non-rigid one. The major drawback of non-rigidly connected FDPs is tooth intrusion.


Assuntos
Dente Suporte , Implantes Dentários , Planejamento de Dentadura , Prótese Parcial Fixa , Falha de Restauração Dentária , Humanos
19.
J Prosthodont ; 23(3): 213-20, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23889762

RESUMO

PURPOSE: The purpose of this study was to compare the effect of variations in translucency and background on color differences (ΔE) for different shades of computer-aided design and computer-aided manufacturing (CAD/CAM) lithium disilicate glass ceramics. MATERIALS AND METHODS: A pilot study suggested n = 10 as an appropriate sample size for the number of lithium disilicate glass ceramic cylinders per group. High-transparency (HT) and low-transparency (LT) cylinders (diameter, 12 mm; length, 13 mm) were fabricated in three ceramic shades (BL1, A2, C3) using CAD/CAM technology and were cut into specimen disks (thickness, 1.2 mm; diameter, 12 mm) for placement on Natural Die (ND1 and ND4) backgrounds. Four combinations of translucency and background color were evaluated in terms of color differences for the three ceramic shades: group 1 (HT ND1, reference), group 2 (HT ND4), group 3 (LT ND1), and group 4 (LT ND4). A spectrophotometer was used to measure the color differences. Nonparametric tests (Kruskal-Wallis tests) were used to evaluate the color differences among the tested groups, and Mann-Whitney U tests with Bonferroni correction were used as post hoc tests. Furthermore, for each ceramic shade, the HT groups were compared to the LT groups using the Mann-Whitney U test. RESULTS: Significant differences were present among the tested groups of the same ceramic shade (p < 0.001). The highest ΔE values were observed in the HT ND4 group for BL1, while the lowest ΔE values were found in the LT ND1 group for both A2 and C3. Further, the HT groups and the groups with a darker background (ND4) showed increased ΔE values compared with the other groups (p < 0.001). CONCLUSIONS: Within the limitations of this study, the results suggested that the translucency and background color significantly influenced the lithium disilicate glass ceramic color among the BL1, A2, and C3 ceramic shades. Changing the underlying color from a lighter background to a darker background resulted in increased color differences.


Assuntos
Cerâmica/química , Desenho Assistido por Computador , Materiais Dentários/química , Porcelana Dentária/química , Cor , Cristalização , Temperatura Alta , Luz , Teste de Materiais , Espectrofotometria/métodos , Propriedades de Superfície
20.
J Prosthet Dent ; 110(6): 494-500, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24176183

RESUMO

STATEMENT OF PROBLEM: The replication of natural teeth, especially with single-tooth restorations, represents a challenge. Similar to metal ceramic crowns, different designs of zirconia substructures have been suggested to improve the esthetic results of zirconia ceramic crowns. PURPOSE OF STUDY: The purpose of the study was to analyze the color of the cervical portion of single zirconia ceramic crowns fabricated with different zirconia coping designs. MATERIAL AND METHODS: The color, measured on the CIELAB color scale, of 3 different groups of restorations (n=10) fabricated with zirconia coping (Lava) and feldspathic porcelain (Noritake Super Porcelain) was analyzed with a spectrophotometer. Conventional zirconia crowns with zirconia facial margins were compared with ceramic crowns with porcelain facial margins and either a horizontal reduction of the zirconia coping (1.0 mm reduction) or an additional vertical reduction (1.0 mm additional reduction). The 3 groups, each with a different coping extension, were examined with a 1-way ANOVA and the Fisher exact test, and the differences of the groups were evaluated by applying ΔE thresholds (α=.05). RESULTS: The mean color difference among all the groups was not clinically significant (ΔE<3.7). Reduced color differences were present between the 2 porcelain butt margin groups of crowns (ΔE=1.06, between group H and V). Increased differences were present between the zirconia margin group and the porcelain butt margin group (ΔE=2.54 between group C and H; ΔE=2.41 between group C and V). Lab* values were examined in all the groups of crowns to determine the clinical implications. CONCLUSIONS: Within the limitation of the study, no significant differences were present among the tested groups of crowns. Nevertheless, although some differences were present between the zirconia margin group and the porcelain butt margin group, reduced differences were present between the 2 different cutback designs.


Assuntos
Coroas , Materiais Dentários/química , Planejamento de Prótese Dentária , Zircônio/química , Silicatos de Alumínio/química , Cor , Porcelana Dentária/química , Estética Dentária , Humanos , Incisivo/anatomia & histologia , Teste de Materiais , Compostos de Potássio/química , Cimentos de Resina/química , Espectrofotometria/métodos , Propriedades de Superfície , Colo do Dente/anatomia & histologia , Preparo Prostodôntico do Dente/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...