1.
Int J Prosthodont ; 15(3): 303-6, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12066496

RESUMO

PURPOSE: This article describes a new procedure for immediate implant-supported oral rehabilitation using a photocurable resin skull model and a laser-welding apparatus. MATERIALS AND METHODS: Preoperatively, the framework was fabricated on a photocurable resin skull model produced from a CT scan and individually designed guide template. The implants were immediately placed using the guide template; laser welding connected the components of framework. RESULTS: Despite the custom-made prosthesis, the total treatment from implant placement to superstructure placement can be completed within only 1 day. CONCLUSION: This procedure for immediate implant-supported oral rehabilitation using a photocurable resin skull model and a laser-welding apparatus may be useful for any implant system and patient.


Assuntos
Prótese Dentária Fixada por Implante , Soldagem em Odontologia/métodos , Planejamento de Dentadura , Retenção de Dentadura , Lasers , Modelos Anatômicos , Plásticos , Crânio , Articuladores Dentários , Implantação Dentária Endóssea/instrumentação , Implantação Dentária Endóssea/métodos , Implantes Dentários , Prótese Parcial Fixa , Prótese Parcial Imediata , Seguimentos , Humanos , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/reabilitação , Arcada Edêntula/cirurgia , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Planejamento de Assistência ao Paciente , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
2.
Clin Oral Implants Res ; 13(2): 221-4, 2002 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11952743

RESUMO

The purpose of the present study was to evaluate the difference in stress transfer between titanium (Ti) and hydroxyapatite (HA) by the measurement of bone marrow pressure using a catheter pressure transducer. Ti and HA implants were inserted in the tibiae of rabbits. A hole of 1 mm in diameter was drilled in the bone and a fine catheter pressure transducer was placed in the bone marrow through a tube. The top of the abutment was vertically tapped with an impulse hammer, and the acceleration signal from the hammer and pressure signal from the catheter pressure transducer were examined. The time of contact (impulse duration) recorded in the impulse with Ti and HA was 166+/-17 micro sec and 164 +/- 17 micro sec, respectively. Maximum bone marrow pressure (BMP) with Ti and HA was 54.2 +/- 32.6 and 47.5 +/- 10.0 mmHg, respectively. Variation of the BMP with Ti was significantly larger than that with HA (P < 0.05). A negative correlation coefficient between impulse duration and BMP was found. The results of the present study suggest that the stress transfer is different between Ti and HA implants using dynamics of the bone marrow pressure.


Assuntos
Materiais Biocompatíveis , Medula Óssea/fisiologia , Implantação Dentária Endóssea/métodos , Implantes Dentários , Durapatita , Titânio , Aceleração , Animais , Materiais Biocompatíveis/química , Fenômenos Biomecânicos , Dente Suporte , Durapatita/química , Masculino , Percussão/instrumentação , Pressão , Coelhos , Processamento de Sinais Assistido por Computador , Estatística como Assunto , Estresse Mecânico , Tíbia/cirurgia , Titânio/química , Transdutores de Pressão