Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
RSC Adv ; 14(29): 20572-20584, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38946768

RESUMO

Complexes tris((1-ferrocenyl-1H-1,2,3-triazol-4-yl)methyl)amine (3), bis((1-ferrocenyl-1H-1,2,3-triazol-4-yl)methyl)amine (6), bis((1-ferrocenyl-1H-1,2,3-triazol-4-yl)methyl)ether (7), and 1-ferrocenyl-1H-1,2,3-triazol-4-yl)methanamine (9) were synthesized using the copper-catalyzed click reaction. Complexes 3, 6, 7, and 9 were characterized using NMR (1H and 13{1H}) and IR spectroscopy, elemental analysis, and mass spectrometry. Structures of 3, 7, and 9 in the solid state were determined using single-crystal X-ray diffraction. It was found that the triazole rings were planar and slightly twisted with respect to the cyclopentadienyl groups attached to them. Chains and 3D network structures were observed due to the presence of π⋯π and C-H⋯N interactions between the cyclopentadienyl and triazole ligands. A reversible redox behavior of the Fc groups between 239 and 257 mV with multicycle stability was characteristic for all the compounds, revealing that the electrochemically generated species Fc+ remained soluble in dichloromethane. Electrochemical sensor tests demonstrated the applicability of all the complexes to enhance the quantification sensing behavior of the screen-printed carbon electrode (SPCE) toward Cd2+, Pb2+, and Cu2+ ions.

2.
ACS Appl Electron Mater ; 6(6): 4718-4734, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38947952

RESUMO

Flexible temperature sensors are becoming increasingly important these days. In this work, we explore graphene oxide (GO)/poly(vinyl alcohol) (PVA) nanocomposites for potential application in temperature sensors. The influence of the mixing ratio of both materials, the reduction temperature, and passivation on the sensing performance has been investigated. Various spectroscopic techniques revealed the composite structure and atomic composition. These were complemented by semiempirical quantum chemical calculations to investigate rGO and PVA interaction. Scanning electron and atomic force microscopy measurements were carried out to evaluate dispersion and coated film quality. The temperature sensitivity has been evaluated for several composite materials with different compositions in the range from 10 to 80 °C. The results show that a linear temperature behavior can be realized based on rGO/PVA composites with temperature coefficients of resistance (TCR) larger than 1.8% K-1 and a fast response time of 0.3 s with minimal hysteresis. Furthermore, humidity influence has been investigated in the range from 10% to 80%, and a minor effect is shown. Therefore, we can conclude that rGO/PVA composites have a high potential for excellent passivation-free, humidity-independent, sensitive, and fast response temperature sensors for various applications. The GO reduction is tunable, and PVA improves the rGO/PVA sensor performance by increasing the tunneling effect and band gap energy, consequently improving temperature sensitivity. Additionally, PVA exhibits minimal water absorption, reducing the humidity sensitivity. rGO/PVA maintains its temperature sensitivity during and after several mechanical deformations.

3.
ACS Omega ; 9(26): 28951-28960, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38973911

RESUMO

In the modern era of the Internet of Things, the potential role of flexible piezoelectric generators (PEG) reflects the rapid increase in self-powered devices and wearable technologies. In this study, a casting process to elaborate the polydimethylsiloxane (PDMS)/barium titanate (BaTiO 3) composite has been presented. The addition of 15 wt % BaTiO 3 microparticles into the PDMS polymer greatly enhances the piezoelectric coefficient (d 31 = 24 pC N-1), leading to an increased output voltage of approximately 4 V under finger tapping force. The proposed flexible microgenerator yielded an excellent piezoelectric figure of merit (FoM 31 = 13.1 × 10-12 m2 N-1), significantly enhancing successfully the energy-harvesting performance (power density of 35 nW/cm2). Furthermore, the fabricated lead-free PEG exhibited an excellent flexibility figure of merit (fFoM) due to the low young modulus values (Maximum E = 3.4 MPa). These results indicate efficient energy conversion and demonstrate a favorable balance between the flexibility and piezoelectric properties of the composite, highlighting its potential for a wide range of applications in self-powered wearable sensors able to collect different human motions in applications such as gesture tracking and finger motion detection.

4.
Sensors (Basel) ; 24(11)2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38894429

RESUMO

Effective feature extraction and selection are crucial for the accurate classification and prediction of hand gestures based on electromyographic signals. In this paper, we systematically compare six filter and wrapper feature evaluation methods and investigate their respective impacts on the accuracy of gesture recognition. The investigation is based on several benchmark datasets and one real hand gesture dataset, including 15 hand force exercises collected from 14 healthy subjects using eight commercial sEMG sensors. A total of 37 time- and frequency-domain features were extracted from each sEMG channel. The benchmark dataset revealed that the minimum Redundancy Maximum Relevance (mRMR) feature evaluation method had the poorest performance, resulting in a decrease in classification accuracy. However, the RFE method demonstrated the potential to enhance classification accuracy across most of the datasets. It selected a feature subset comprising 65 features, which led to an accuracy of 97.14%. The Mutual Information (MI) method selected 200 features to reach an accuracy of 97.38%. The Feature Importance (FI) method reached a higher accuracy of 97.62% but selected 140 features. Further investigations have shown that selecting 65 and 75 features with the RFE methods led to an identical accuracy of 97.14%. A thorough examination of the selected features revealed the potential for three additional features from three specific sensors to enhance the classification accuracy to 97.38%. These results highlight the significance of employing an appropriate feature selection method to significantly reduce the number of necessary features while maintaining classification accuracy. They also underscore the necessity for further analysis and refinement to achieve optimal solutions.


Assuntos
Eletromiografia , Gestos , Mãos , Humanos , Eletromiografia/métodos , Mãos/fisiologia , Algoritmos , Masculino , Adulto , Feminino , Processamento de Sinais Assistido por Computador
5.
Sci Total Environ ; 935: 173262, 2024 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-38768719

RESUMO

Growing concerns about pesticide residues in agriculture are pushing the scientific community to develop innovative and efficient methods for detecting these substances at low concentrations down to the molecular level. In this context, surface-enhanced Raman spectroscopy (SERS) is a powerful analytical method that has so far already undergone some validation for its effectiveness in pesticide detection. However, despite its great potential, SERS faces significant difficulties obtaining reproducible and accurate pesticide spectra, particularly for some of the most widely used pesticides, such as malathion, chlorpyrifos, and imidacloprid. Those inconsistencies can be attributed to several factors, such as interactions between pesticides and SERS substrates and the variety of substrates and solvents used. In addition, differences in the equipment used to obtain SERS spectra and the lack of standards for control experiments further complicate the reproducibility and reliability of SERS data. This review systematically discusses the problems mentioned above, including a comprehensive analysis of the challenges in precisely evaluating SERS spectra for pesticide detection. We not only point out the existing limitations of the method, which can be traced in previous review works, but also offer practical recommendations to improve the quality and comparability of SERS spectra, thereby expanding the potential applications of the method in such an essential field as pesticide detection.

6.
Sci Rep ; 14(1): 8289, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594349

RESUMO

This paper is focused on the diagnostics of multicopter UAV propulsion system, in which the temporary transient states occur during operation in faulty conditions (eg. not all motor phases working properly). As a diagnostic sensor, the piezo strip has been used, which is very sensitive to any vibrations of the multi-rotor frame. The paper concerns the precise location of the sensor for more effective monitoring of the propulsion system state. For this purpose, a nonlinear analysis of the vibration times series was carefully presented. The obtained non-linear time series were studied with the recurrence analysis in short time windows, which were sensitive to changes in Unmanned Aerial Vehicle motor speeds. The tests were carried out with different percentage of the pulse width modulation signal used for the operation of the brushless motor and for different locations of the piezosensor (side and top planes of the multicopter arm). In the article, it was shown that the side location of the piezosensor is more sensitive to changes in the Unmanned Aerial Vehicle propulsion system, which was studied with the Principal Component Analysis method applied for four main recurrence quantifications. The research presented proves the possibility of using nonlinear recurrence analysis for propulsion system diagnostics and helps to determine the optimal sensor location for more effective health monitoring of multicopter motor.

7.
Sensors (Basel) ; 24(5)2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38475121

RESUMO

In this study, a multiwalled carbon nanotube (MWCNT) dispersion is used as an ink for a single-nozzle inkjet printing system to produce a planar coil that can be used to determine strain wirelessly. The MWCNT dispersion is non-covalently functionalized by dispersing the CNTs in an anionic surfactant, namely sodium dodecyl sulfate (SDS). The fabrication parameters, such as sonication energy and centrifugation time, are optimized to obtain an aqueous suspension suitable for an inkjet printer. Planar coils with different design parameters are printed on a flexible polyethylene terephthalate (PET) polymer substrate. The design parameters include a different number of windings, inner diameter, outer diameter, and deposited layers. The electrical impedance spectroscopy (EIS) analysis is employed to characterize the printed planar coils, and an equivalent electrical circuit model is derived based on the results. Additionally, the radio frequency identification technique is utilized to wirelessly investigate the read-out mechanism of the printed planar MWCNT coils. The complex impedance of the inductively coupled sensor undergoes a shift under strain, allowing for the monitoring of changes in resonance frequency and bandwidth (i.e., amplitude). The proposed wireless strain sensor exhibits a remarkable gauge factor of 22.5, which is nearly 15 times higher than that of the wireless strain sensors based on conventional metallic strain gauges. The high gauge factor of the proposed sensor suggests its high potential in a wide range of applications, such as structural health monitoring, wearable devices, and soft robotics.

8.
Discov Nano ; 19(1): 59, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38548950

RESUMO

The interaction of CO2 laser with polyimide results in the formation of laser-induced graphene (LIG) and other morphological transitions based on laser parameters, such as Laser-induced fibers (LIF) on the surface. However, a fundamental investigation of LIF, its properties and potential have not been explored until now. We aim therefore to provide novel insights into the LIF by characterization of its structural, electrical, electrochemical, and mechanical properties. Four different morphologies were identified depending on the laser parameters and the temperature required for their formation were quantified by FEM model. Minimum temperatures of 1800 K were required to form LIG and around 2600 to 5000 K to form LIF. High heterogeneity of the LIF along thickness due to temperature gradients, and the existence of sheet structures underneath the fibers were identified. Due to the loosely bound nature of fibers, LIF dispersion was prepared by ultrasonication to functionalize the carbon electrode for electrochemical characterization. The modification with LIF on the electrodes enhanced the electrochemical response of the electrode towards standard redox couple which confirmed the conductive nature of the fibers. This work provides a solid basis for the versatile tuning of the behavior and properties of LIF for potential applications.

9.
Biosens Bioelectron ; 249: 115937, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38211465

RESUMO

Helicobacter pylori (H. pylori) is classified as a class I carcinogen that colonizes the human gastrointestinal (GI) tract. The detection at low concentrations is crucial in combatting H. pylori. HopQ protein is located on H. pylori's outer membrane and is expressed at an early stage of contamination, which signifies it as an ideal biomarker. In this study, we presented the development of an electrochemical impedimetric immunosensor for the ultra-sensitive detection of HopQ at low concentrations. The sensor employed polypyrrole nanotubes (PPy-NTs) and carboxylated multi-walled carbon nanotubes (MWCNT-COOH) nanocomposite. PPy-NTs were chosen for their excellent conductivity, biocompatibility, and redox capabilities, simplifying sample preparation by eliminating the need to add redox probes upon measurement. MWCNT-COOH provided covalent binding sites for HopQ antibodies (HopQ-Ab) on the biosensor surface. Characterization of the biosensor was performed using scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), contact angle measurements, and electrochemical impedance spectroscopy (EIS), complemented by numerical semiempirical quantum calculations. The results demonstrated a dynamic linear range of 5 pg/mL to 1.063 ng/mL and an excellent selectivity, with the possibility of excluding interference using EIS data, specifically charge transfer resistance and double-layer capacitance as multivariants for the calibration curve. Using two EIS components, the limit of detection is calculated to be 2.06 pg/mL. The biosensor was tested with a spiked drinking water sample and showed a signal recovery of 105.5% when detecting 300 pg/mL of HopQ. This novel H. pylori biosensor offers reliable, simple, portable, and rapid screening of the bacteria.


Assuntos
Técnicas Biossensoriais , Helicobacter pylori , Nanocompostos , Nanotubos de Carbono , Humanos , Polímeros/química , Nanotubos de Carbono/química , Pirróis/química , Proteínas de Membrana , Técnicas Biossensoriais/métodos , Imunoensaio , Biomarcadores , Nanocompostos/química , Eletrodos , Técnicas Eletroquímicas/métodos , Limite de Detecção
10.
Materials (Basel) ; 16(21)2023 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-37959478

RESUMO

This review article dives into the complex world of biocompatibility testing: chemical, mechanical, and biological characterization, including many elements of biocompatibility, such as definitions, descriptive examples, and the practical settings. The focus extends to evaluating standard documents obtained from reliable organizations; with a particular focus on open-source information, including FDA-USA, ISO 10933 series, and TÜV SÜD. We found a significant gap in this field: biomaterial scientists and those involved in the realm of medical device development in general, and implants in particular, lack access to a tool that reorganizes the process of selecting the appropriate biocompatibility test for the implant being examined. This work progressed through two key phases that aimed to provide a solution to this gap. A straightforward "yes or no" flowchart was initially developed to guide biocompatibility testing decisions based on the previously accumulated information. Subsequently, the Python code was employed, generating a framework through targeted questions. This work reshapes biocompatibility evaluation, bridging theory and practical implementation. An integrated approach via a flowchart and the Python code empowers stakeholders to navigate biocompatibility testing effortlessly. To conclude, researchers are now better equipped for a safer, more effective implant development, propelling the field towards improved patient care and innovative progress.

11.
Sensors (Basel) ; 23(19)2023 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-37837021

RESUMO

Wake-up receivers are gaining importance in power-aware wireless sensor networks, as they significantly reduce power consumption during RF reception, enabling asynchronous communication with low latency. However, the performance of wake-up receivers still lags behind that of off-the-shelf RF transceivers. There is a growing demand for higher sensitivity, enhanced reliability, and lower latency while maintaining the lowest power consumption. In this article, our goal is to advance the performance of wake-up receivers based on off-the-shelf components and low-frequency pattern matchers. Through a systematic investigation, we proposed multiple improvements aimed at enhancing wake-up receiver performance and reliability. We introduced an improved passive envelope detector and realized a wake-up receiver for the 868 MHz band, which achieves a power consumption of 5.71 µW and latency of 9.02 ms. Our proposed wake-up receiver is capable of detecting signals down to an average power level of -61.6 dBm. These achievements represent significant advancements compared to the existing state of research on wake-up receivers based on low-frequency pattern matchers. Recent articles have not been able to attain such improved values in signal detection, power consumption, and latency.

12.
Bioengineering (Basel) ; 10(6)2023 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-37370634

RESUMO

Accurate diagnosis and classification of epileptic seizures can greatly support patient treatments. As many epileptic seizures are convulsive and have a motor component, the analysis of muscle activity can provide valuable information for seizure classification. Therefore, this paper present a feasibility study conducted on healthy volunteers, focusing on tracking epileptic seizures movements using surface electromyography signals (sEMG) measured on human limb muscles. For the experimental studies, first, compact wireless sensor nodes were developed for real-time measurement of sEMG on the gastrocnemius, flexor carpi ulnaris, biceps brachii, and quadriceps muscles on the right side and the left side. For the classification of the seizure, a machine learning model has been elaborated. The 16 common sEMG time-domain features were first extracted and examined with respect to discrimination and redundancy. This allowed the features to be classified into irrelevant features, important features, and redundant features. Redundant features were examined with the Big-O notation method and with the average execution time method to select the feature that leads to lower complexity and reduced processing time. The finally selected six features were explored using different machine learning classifiers to compare the resulting classification accuracy. The results show that the artificial neural network (ANN) model with the six features: IEMG, WAMP, MYOP, SE, SKEW, and WL, had the highest classification accuracy (99.95%). A further study confirms that all the chosen eight sensors are necessary to reach this high classification accuracy.

13.
Biosensors (Basel) ; 13(5)2023 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-37232889

RESUMO

Helicobacter pylori (H. pylori) is a highly contagious pathogenic bacterium that can cause gastrointestinal ulcers and may gradually lead to gastric cancer. H. pylori expresses the outer membrane HopQ protein at the earliest stages of infection. Therefore, HopQ is a highly reliable candidate as a biomarker for H. pylori detection in saliva samples. In this work, an H. pylori immunosensor is based on detecting HopQ as an H. pylori biomarker in saliva. The immunosensor was developed by surface modification of screen-printed carbon electrodes (SPCE) with MWCNT-COOH decorated with gold nanoparticles (AuNP) followed by HopQ capture antibody grafting on SPCE/MWCNT/AuNP surface using EDC/S-NHS chemistry. The sensor performance was investigated utilizing various methods, such as cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and scanning electron microscope (SEM) coupled with energy-dispersive X-ray spectroscopy (EDX). H. pylori detection performance in spiked saliva samples was evaluated by square wave voltammetry (SWV). The sensor is suitable for HopQ detection with excellent sensitivity and linearity in the 10 pg/mL-100 ng/mL range, with a 2.0 pg/mL limit of detection (LOD) and an 8.6 pg/mL limit of quantification (LOQ). The sensor was tested in saliva at 10 ng/mL, and recovery of 107.6% was obtained by SWV. From Hill's model, the dissociation constant Kd for HopQ/HopQ antibody interaction is estimated to be 4.60 × 10-10 mg/mL. The fabricated platform shows high selectivity, good stability, reproducibility, and cost-effectiveness for H. pylori early detection due to the proper choice of biomarker, the nanocomposite material utilization to boost the SPCE electrical performance, and the intrinsic selectivity of the antibody-antigen approach. Additionally, we provide insight into possible future aspects that researchers are recommended to focus on.


Assuntos
Técnicas Biossensoriais , Helicobacter pylori , Nanopartículas Metálicas , Ouro , Técnicas Biossensoriais/métodos , Reprodutibilidade dos Testes , Imunoensaio , Biomarcadores , Limite de Detecção , Técnicas Eletroquímicas/métodos , Eletrodos
14.
Nanomaterials (Basel) ; 13(9)2023 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-37177018

RESUMO

In this paper, the relative humidity sensor properties of graphene oxide (GO) and graphene oxide/multiwalled nanotubes (GO/MWNTs) composites have been investigated. Composite sensors were fabricated by direct laser scribing and characterized using UV-vis-NIR, Raman, Fourier transform infrared, and X-ray photoemission spectroscopies, electron scanning microscopy coupled with energy-dispersive X-ray analysis, and impedance spectroscopy (IS). These methods confirm the composite homogeneity and laser reduction of GO/MWNT with dominant GO characteristics, while ISresults analysis reveals the circuit model for rGO-GO-rGO structure and the effect of MWNT on the sensor properties. Although direct laser scribing of GO-based humidity sensor shows an outstanding response (|ΔZ|/|Z| up to 638,800%), a lack of stability and repeatability has been observed. GO/MWNT-based humidity sensors are more conductive than GO sensors and relatively less sensitive (|ΔZ|/|Z| = 163,000%). However, they are more stable in harsh humid conditions, repeatable, and reproducible even after several years of shelf-life. In addition, they have fast response/recovery times of 10.7 s and 9.3 s and an ultra-fast response time of 61 ms when abrupt humidification/dehumidification is applied by respiration. All carbon-based sensors' overall properties confirm the advantage of introducing the GO/MWNT hybrid and laser direct writing to produce stable structures and sensors.

15.
Sensors (Basel) ; 23(6)2023 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-36991672

RESUMO

The transition of electrochemical sensors from lab-based measurements to real-time analysis requires special attention to different aspects in addition to the classical development of new sensing materials. Several critical challenges need to be addressed including a reproducible fabrication procedure, stability, lifetime, and development of cost-effective sensor electronics. In this paper, we address these aspects exemplarily for a nitrite sensor. An electrochemical sensor has been developed using one-step electrodeposited (Ed) gold nanoparticles (EdAu) for the detection of nitrite in water, which shows a low limit of detection of 0.38 µM and excellent analytical capabilities in groundwater. Experimental investigations with 10 realized sensors show a very high reproducibility enabling mass production. A comprehensive investigation of the sensor drift by calendar and cyclic aging was carried out for 160 cycles to assess the stability of the electrodes. Electrochemical impedance spectroscopy (EIS) shows significant changes with increasing aging inferring the deterioration of the electrode surface. To enable on-site measurements outside the laboratory, a compact and cost-effective wireless potentiostat combining cyclic and square wave voltammetry, and EIS capabilities has been designed and validated. The implemented methodology in this study builds a basis for the development of further on-site distributed electrochemical sensor networks.

16.
Sensors (Basel) ; 23(4)2023 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-36850428

RESUMO

Piezoelectric Vibration converters are nowadays gaining importance for supplying low-powered sensor nodes and wearable electronic devices. Energy management interfaces are thereby needed to ensure voltage compatibility between the harvester element and the electric load. To improve power extraction ability, resonant interfaces such as Parallel Synchronized Switch Harvesting on Inductor (P-SSHI) have been proposed. The main challenges for designing this type of energy management circuits are to realise self-powered solutions and increase the energy efficiency and adaptability of the interface for low-power operation modes corresponding to low frequencies and irregular vibration mechanical energy sources. In this work, a novel Self-Powered (SP P-SSHI) energy management circuit is proposed which is able to harvest energy from piezoelectric converters at low frequencies and irregular chock like footstep input excitations. It has a good power extraction ability and is adaptable for different storage capacitors and loads. As a proof of concept, a piezoelectric shoe insole with six integrated parallel piezoelectric sensors (PEts) was designed and implemented to validate the performance of the energy management interface circuit. Under a vibration excitation of 1 Hz corresponding to a (moderate walking speed), the maximum reached efficiency and power of the proposed interface is 83.02% and 3.6 mW respectively for the designed insole, a 10 kΩ resistive load and a 10 µF storage capacitor. The enhanced SP-PSSHI circuit was validated to charge a 10 µF capacitor to 6 V in 3.94 s and a 1 mF capacitor to 3.2 V in 27.64 s. The proposed energy management interface has a cold start-up ability and was also validated to charge a (65 mAh, 3.1 V) maganese dioxide coin cell Lithium battery (ML 2032), demonstrating the ability of the proposed wearable piezoelectric energy harvesting system to provide an autonomous power supply for wearable wireless sensors.

17.
Polymers (Basel) ; 15(3)2023 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-36772040

RESUMO

An electrochemical sensor for the pesticide Pirimicarb (PMC) has been developed. A screen-printed electrode (SPCE) was used and modified with the conducting polymer poly (3,4-ethylenedioxythiophene) (PEDOT) and gold nanoparticles (AuNPs) to enhance electrochemical proprieties. Electrode characterizations were performed using scattering electron microscopy (SEM) and cyclic voltammetry (CV). With the SPCE/PEDOT:PSS/AuNPs modified electrode, a new peak at 1.0 V appeared in the presence of PMC related to the PMC oxidation. To elucidate the mechanism of PMC oxidation, Gas Chromatography-Mass Spectrometry (GC-MS), where two major peaks were identified, evidencing that the device can both detect and degrade PMC by an electro-oxidation process. Exploring this peak signal, it was possible the sensor development, performing detection from 93.81-750 µmol L-1, limits of quantification (LOQ) and detection (LOD) of 93.91 µmol L-1 and 28.34 µmol L-1, respectively. Thus, it was possible to study and optimization of PMC degradation, moreover, to perform detection at low concentrations and with good selectivity against different interferents using a low-cost printed electrode based on graphite modified with conductive polymer and AuNPs.

18.
Sensors (Basel) ; 23(3)2023 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-36772136

RESUMO

The recognition of hand signs is essential for several applications. Due to the variation of possible signals and the complexity of sensor-based systems for hand gesture recognition, a new artificial neural network algorithm providing high accuracy with a reduced architecture and automatic feature selection is needed. In this paper, a novel classification method based on an extreme learning machine (ELM), supported by an improved grasshopper optimization algorithm (GOA) as a core for a weight-pruning process, is proposed. The k-tournament grasshopper optimization algorithm was implemented to select and prune the ELM weights resulting in the proposed k-tournament grasshopper extreme learner (KTGEL) classifier. Myographic methods, such as force myography (FMG), deliver interesting signals that can build the basis for hand sign recognition. FMG was investigated to limit the number of sensors at suitable positions and provide adequate signal processing algorithms for perspective implementation in wearable embedded systems. Based on the proposed KTGEL, the number of sensors and the effect of the number of subjects was investigated in the first stage. It was shown that by increasing the number of subjects participating in the data collection, eight was the minimal number of sensors needed to result in acceptable sign recognition performance. Moreover, implemented with 3000 hidden nodes, after the feature selection wrapper, the ELM had both a microaverage precision and a microaverage sensitivity of 97% for the recognition of a set of gestures, including a middle ambiguity level. The KTGEL reduced the hidden nodes to only 1000, reaching the same total sensitivity with a reduced total precision of only 1% without needing an additional feature selection method.


Assuntos
Algoritmos , Gestos , Humanos , Redes Neurais de Computação , Fenômenos Mecânicos , Miografia , Mãos
19.
Micromachines (Basel) ; 14(1)2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36677287

RESUMO

Monitoring changes in edema-associated intracranial pressure that complicates trauma or surgery would lead to improved outcomes. Implantable pressure sensors have been explored, but these sensors require post-surgical removal, leading to the risk of injury to brain tissue. The use of biodegradable implantable sensors would help to eliminate this risk. Here, we demonstrate a bioactive glass (BaG)-based hydration sensor. Fluorine (CaF2) containing BaG (BaG-F) was produced by adding 5, 10 or 20 wt.% of CaF2 to a BaG matrix using a melting manufacturing technique. The structure, morphology and electrical properties of the resulting constructs were evaluated to understand the physical and electrical behaviors of this BaG-based sensor. Synthesis process for the production of the BaG-F-based sensor was validated by assessing the structural and electrical properties. The structure was observed to be amorphous and dense, the porosity decreased and grain size increased with increasing CaF2 content in the BaG matrix. We demonstrated that this BaG-F chemical composition is highly sensitive to hydration, and that the electrical sensitivity (resistive-capacitive) is induced by hydration and reversed by dehydration. These properties make BaG-F suitable for use as a humidity sensor to monitor brain edema and, consequently, provide an alert for increased intracranial pressure.

20.
Foods ; 12(2)2023 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-36673364

RESUMO

Different environmental parameters, such as temperature and humidity, aggravate food spoilage, and different volatile organic compounds (VOCs) are released based on the extent of spoilage. In addition, a lack of efficient monitoring of the dosage of pesticides leads to crop failure. This could lead to the loss of food resources and food production with harmful contaminants and a short lifetime. For this reason, precise monitoring of different environmental parameters and contaminations during food processing and storage is a key factor for maintaining its safety and nutritional value. Thus, developing reliable, efficient, cost-effective sensor devices for these purposes is of utmost importance. This paper shows that Poly-(diallyl-dimethyl ammonium chloride)/reduced Graphene oxide (PDAC/rGO) films produced by a simple Layer-by-Layer deposition can be effectively used to monitor temperature, relative humidity, and the presence of volatile organic compounds as indicators for spoilage odors. At the same time, they show potential for electrochemical detection of organophosphate pesticide dimethoate. By monitoring the resistance/impedance changes during temperature and relative humidity variations or upon the exposure of PDAC/rGO films to methanol, good linear responses were obtained in the temperature range of 10-100 °C, 15-95% relative humidity, and 35 ppm-55 ppm of methanol. Moreover, linearity in the electrochemical detection of dimethoate is shown for the concentrations in the order of 102 µmol dm-3. The analytical response to different external stimuli and analytes depends on the number of layers deposited, affecting sensors' sensitivity, response and recovery time, and long-term stability. The presented results could serve as a starting point for developing advanced multi-modal sensors and sensor arrays with high potential for analytical applications in food safety and quality monitoring.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...