Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Comput Methods Programs Biomed ; 108(3): 1149-59, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23010604

RESUMO

The present research investigates the relationship between the central corneal thickness (CCT), Heidelberg Retina Tomograph II (HRTII) structural measurements and intraocular pressure (IOP) using an innovative non-linear multivariable regression method in order to define the risk factors in future glaucoma development and patient management. The method is implemented to data from ninety-three open angle glaucoma eyes. The results show that in established glaucoma, CCT is significantly associated with HRTII structural measurements (maximum contour depression, cup volume inferotemporally) and IOP. They are also compared to those obtained from the application of standard linear regression methods, improving the coefficient determination R(2) by 35%, exhibiting thus the performance of the proposed methodology.


Assuntos
Glaucoma/fisiopatologia , Humanos , Modelos Teóricos , Análise Multivariada , Medição de Risco
2.
Conf Proc IEEE Eng Med Biol Soc ; 2004: 2303-6, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-17272189

RESUMO

The capability of detecting electrical conductivity variations using focused microwave radiometry, a method used in clinical applications for temperature distribution imaging of subcutaneous tissues, is discussed in the present study. A novel microwave radiometric system operating at 3.5 GHz, including an ellipsoidal conductive wall cavity, which provides the required beamforming and focusing, is developed. The system is capable of providing distribution measurements of the product of conductivity and temperature of any object being at a temperature above the absolute zero. The implemented experimental procedure is based on the results of an electromagnetic numerical analysis using a semianalytical method which was developed in order to compute the focusing properties of the ellipsoidal reflector. Each measurement is realized by placing the region of interest in the area of the first focus of the cavity and collecting the radiation converged at the second by an almost isotropic dipole antenna connected to a sensitive radiometer. Experimental data from cylindrical shaped saline or de-ionized water filled tank phantoms in which saline solutions of different concentrations were infused, provide promising results concerning the system's ability of detecting conductivity variations. Future research is needed in order to elucidate the potential of the proposed methodology to be used for brain conductivity measurements.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...