1.
Ultrasonics ; 120: 106651, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34847528

RESUMO

A microbial test-system for real-time determination of low/residual concentrations of kanamycin in a liquid without the need for special labels is presented. The main element of the system was a piezoelectric resonator excited by a lateral electric field based on an X-cut lithium niobate plate 0.5 mm thick with two rectangular electrodes on one side. On the other side of the resonator, there was a 1.5 ml liquid container. As a sensory element we used Escherichia coli B-878 microbial cells, which are sensitive to kanamycin. For measurement 1 ml of this cells suspension was placed in a liquid container and then the test liquid in the amount of 2 µl containing kanamycin was added. The change in the real part of the electrical impedance of the resonator before and after the test liquid addition was used as an analytical signal which indicated the presence of kanamycin. The lower limit of determination of kanamycin turned out to be 1.0 µg/ml with an analysis time of 10 min. The test-system allows to detect kanamycin in the presence of such antibiotic as ampicillin and polymixin.


Assuntos
Técnicas Biossensoriais/instrumentação , Técnicas Eletroquímicas/instrumentação , Canamicina/química , Antibacterianos/química , Impedância Elétrica , Escherichia coli/efeitos dos fármacos , Nióbio/química , Óxidos/química , Suspensões
2.
Biosens Bioelectron ; 130: 95-102, 2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-30731351

RESUMO

The paper describes a new biological sensor which represents a resonator based on a segment of a rectangular waveguide of 8 GHz band with shear dimensions of 28.5 × 12.6 mm2. On one side, the resonator is bounded by a metallic short-circuited wall; on the other side, it is bounded by a lithium niobate plate with a porous polystyrene film. This film, applied by centrifugation and modified in high-frequency discharge plasma in argon, was used to immobilize cells of Escherichia coli K-12. This resonator was connected through a coaxial-waveguide adapter to the S parameter meter, by means of which the reflection coefficient S11 in the plane of the lithium niobate plate was measured. The addition of an aqueous solution of ampicillin at 4-50 µg/ml to immobilized cells led to a significant change in the reflection coefficient of S11 from - 10.15 dB to - 15.09 dB. At the same time, the resonance frequency changed insignificantly within the range 8.06-8.068 GHz. The optimal time for modifying the polystyrene film for obtaining the required porosity and the optimal time for the immobilization of the bacterial cells were determined. The immobilized cells retained their activity for 4 months at a temperature of 4 °C. The study showed the promise of such a biosensor to determine ß-lactam antibiotics in aqueous solutions by using ampicillin as an example. The limit of detection of the developed biosensor with respect to ampicillin was established (4 µg/ml).


Assuntos
Ampicilina/isolamento & purificação , Técnicas Biossensoriais , Escherichia coli K12/química , Ampicilina/química , Micro-Ondas , Nióbio/química , Óxidos/química , Temperatura , Água/química
3.
Anal Biochem ; 554: 53-60, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29870693

RESUMO

The possibility of the registration of the interaction of the cells Azospirillum lipoferum Sp59b with the specific antibodies directly in the conducting suspensions by using an acoustic sensor was shown. The main element of the sensor is a piezoelectric resonator with a lateral electric field. The analysis is based on a comparison of the resonator's electrical impedance before and after the specific biological interaction between the cells and antibodies. By using this sensor one can detect and identify the bacterial cells directly in the buffer solution with the conductivity between 2.4 and 20 µS/cm. The minimum detectable concentration of the bacterial cells turned out to be ∼103 cells/ml and for a short time (less than 10 min). Also the possibility of the detection of the cells in the presence of the extraneous microflora was shown. The results provide the opportunities for the development of a new class of the methods for the analysis of the microbial cells in real-time directly in the buffer solution.


Assuntos
Anticorpos Antibacterianos , Azospirillum lipoferum/imunologia , Técnicas Biossensoriais/métodos , Acústica , Especificidade de Anticorpos , Reações Antígeno-Anticorpo , Azospirillum lipoferum/ultraestrutura , Soluções Tampão , Sistemas Computacionais , Impedância Elétrica , Lipopolissacarídeos/imunologia
4.
Vopr Virusol ; 61(1): 45-8, 2016.
Artigo em Russo | MEDLINE | ID: mdl-27145602

RESUMO

The bacteriophage ΦAb-Sp7 was isolated from the cells of the Azospirillum brasilense Sp7. The morphology, size of the gram-negative colonies, and range of lytic activity against other strains and species of the genus Azospirillum was tested. The isolated phage DNA was examined using electrophoretic and restriction analysis, and the size of the genome were established. The electron microscopy. resuIts show that the phage (capsid) has a strand-like form. The electron microscopy study of the bacteriophage ΦAb-Sp7 adsorption on the A. brasilense Sp7 bacterial surface was performed.


Assuntos
Azospirillum brasilense/virologia , Bacteriófagos/genética , DNA Viral/química , Genoma Viral , Adsorção , Azospirillum brasilense/química , Azospirillum brasilense/ultraestrutura , Bacteriófagos/crescimento & desenvolvimento , Bacteriófagos/ultraestrutura , Capsídeo/ultraestrutura , Enzimas de Restrição do DNA/química , Tamanho do Genoma , Lisogenia , Mapeamento por Restrição
5.
Biofizika ; 60(4): 722-8, 2015.
Artigo em Russo | MEDLINE | ID: mdl-26394472

RESUMO

The changes in the electro-acoustic parameters of cell suspension due to the interaction of cells with bacteriophages both in a pure. culture and in the presence of extraneous microflora were investigated. It has been found that the specific changes in the electroacoustic parameters of cell suspension under the action of bacteriophage occur only in microbial cells which are sensitive to the bacteriophage studied. It has been established that a sensor unit allows of distinguishing a situation when the bacterial cells are infected with specific bacteriophages of the control experiments and a situation with no introduction of infection. An approximate criterion of the presence of specific interactions of bacteriophages and cells in suspension was developed. In accordance with this criterion the change in electrical impedance of the sensor unit must not be less than - 1%. In control experiments a standard microbiological technique, plating the cells infected with bacteriophages on solid nutrient medium, was used. For the first time the possibility of using the method of electroacoustic analysis for determination of a spectrum of lytic activity of bacteriophages was shown. The results obtained may be used for development of a new express method for determining the sensitivity to bacteriophages of the microbial cells.


Assuntos
Acinetobacter calcoaceticus/virologia , Azospirillum brasilense/virologia , Bacteriófago M13/fisiologia , Escherichia coli/virologia , Lisogenia/fisiologia , Pseudomonas putida/virologia , Acinetobacter calcoaceticus/imunologia , Acústica/instrumentação , Antibiose , Azospirillum brasilense/imunologia , Impedância Elétrica , Escherichia coli/imunologia , Especificidade de Hospedeiro , Pseudomonas putida/imunologia
6.
Biofizika ; 57(3): 460-7, 2012.
Artigo em Russo | MEDLINE | ID: mdl-22873070

RESUMO

The phage mini-antibodies to bacterial cells of strain Azospirillum brasilense Sp245 were obtained and the possibility of using them for detection of microbial cells by means of a lateral field excited piezoelectric resonator was studied. It has been found that the frequency dependencies of the real and imaginary parts of the electrical impedance of the resonator loaded by the cell suspension A. brasilense Sp245 with the mini-antibodies, significantly differ from those of the resonator with the control cell suspension without mini-antibodies. The concentration limit of possible determination of the microbial cells in their interaction with the mini-antibodies is equal to 10(3) cells/ml. It has been ascertained that detection of A. brasilense Sp245 cells using the mini-antibodies is possible even in the presence of other cultures, for example, E. coli BL-Ril and A. brasilense Sp7 cells. Therefore, it has been shown for the first time that detection of microbial cells by an electro-acoustic sensor is feasible.


Assuntos
Anticorpos Antibacterianos/isolamento & purificação , Especificidade de Anticorpos/imunologia , Azospirillum brasilense/imunologia , Azospirillum brasilense/isolamento & purificação , Técnicas Biossensoriais , Anticorpos de Cadeia Única/isolamento & purificação , Acústica/instrumentação , Anticorpos Antibacterianos/imunologia , Antígenos de Bactérias/imunologia , Escherichia coli/imunologia , Escherichia coli/isolamento & purificação , Limite de Detecção , Microscopia Eletrônica , Biblioteca de Peptídeos , Sensibilidade e Especificidade , Anticorpos de Cadeia Única/imunologia