Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Vasc Surg ; 36(1): 100-4, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12096265

RESUMO

OBJECTIVE: Computed tomographic (CT) scan represents the criterion standard for surveillance of endoleaks after endoluminal repair of abdominal aortic aneurysms (erAAAs). Given need for surveillance, risks, and expense of CT scan, the accuracy of color-flow duplex (CFD) scan after erAAA was determined. METHODS: During a 43-month period, patients enrolled in phase II and III of the AneuRx Multicenter Clinical Trial at our institution underwent CFD scan 1 month after erAAA. Patients with CFD scan results that were positive for endoleak underwent CT scanning at 3 months after erAAA, and those with CFD scan results that were negative for endoleak underwent CT scanning at 6 months after erAAA. RESULTS: Seven of 79 patients (9%) who underwent CFD and CT scanning had the diagnosis of endoleak. All endoleaks that were diagnosed with CT scan were detected with CFD scan. One patient had positive results for endoleak with CFD scan at 1 month and then negative results with CT scan at 3 months. Although this may represent resolution of endoleak, this case was counted as a false-positive result. When compared with CT scan, CFD scan had a sensitivity of 100%, specificity of 99%, positive predictive value of 88%, negative predictive value of 100%, and accuracy of 99%. CONCLUSION: CFD scan is an accurate test for the detection of endoleak after erAAA. In addition, most endoleaks diagnosed with CFD scan at 1 month continued to be present at 6 months. This important finding increases the emphasis on the use of this noninvasive test and may initiate earlier intervention of endoleak.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico , Ultrassonografia Doppler Dupla , Reações Falso-Positivas , Seguimentos , Humanos , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Ultrassonografia Doppler Dupla/estatística & dados numéricos
2.
J Vasc Surg ; 35(3): 584-8, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11877712

RESUMO

Although aortic endograft iliac limb occlusion is an uncommon event, its treatment is problematic because standard surgical thrombectomy risks graft dislodgment or component separation. Although femorofemoral bypass grafting can restore perfusion to the affected limb, its longevity may be inferior to reestablishing patency of the endograft itself and represents a failure of the endograft procedure. With aortic endografts now commercially available, implanting surgeons must be aware of this important complication and well versed in all of the endovascular treatment options. We report three cases of endoluminal management of unilateral iliac limb occlusion of bifurcated aortic endografts.


Assuntos
Aorta/transplante , Arteriopatias Oclusivas/etiologia , Arteriopatias Oclusivas/cirurgia , Extremidades/irrigação sanguínea , Artéria Ilíaca/cirurgia , Procedimentos Cirúrgicos Vasculares , Idoso , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Reoperação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...