Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Appl Radiat Isot ; 204: 111109, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38029636

RESUMO

The goal of this study is to provide a benchmark for the use of Monte Carlo simulation when applied to coincidence summing corrections. The examples are based on simple geometries: two types of germanium detectors and four kinds of sources, to mimic eight typical measurement conditions. The coincidence corrective factors are computed for four radionuclides. The exercise input files and calculation results with practical recommendations are made available for new users on a dedicated webpage.

2.
J Environ Radioact ; 268-269: 107249, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37494791

RESUMO

The goal of this work was to develop a methodology for risk assessment in case of an accident originating from a nuclear power plant, and consequently, to improve the relevant radiation monitoring network. In specific, the study involved risk estimation in Greece from a transboundary nuclear power plant accident. The tool employed was JRODOS (Java-based Real-time Decision Support), which is a system for off-site emergency management of radioactive material in the environment. This tool, widely used to generate and study scenarios for nuclear accidents worldwide, provides valuable insight to facilitate emergency preparedness and response. The probability of the plume arriving at numerous regions within the country was calculated, along with the maximum dose rates in case of transport. A risk assessment was performed, and geographical regions were prioritized in terms of risk-based environmental radioactivity burden. A total of 29 administrative districts were identified as low to medium-risk regions. Acquired results were used to determine the optimal spatial distribution of detectors for upgrading the existing monitoring network of environmental radioactivity.


Assuntos
Defesa Civil , Monitoramento de Radiação , Liberação Nociva de Radioativos , Monitoramento de Radiação/métodos , Centrais Nucleares , Medição de Risco
3.
Appl Radiat Isot ; 192: 110589, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36493678

RESUMO

This work aims at providing a Monte-Carlo based methodology for calculating true coincidence correction (TCC) factors for volume sources of varying density. All simulations were carried out using the most recent version of Monte Carlo code PENELOPE. The main program PENMAIN was used for the calculation of full energy peak efficiencies. The subroutine PENNUC was utilized for the same calculation while taking summation effects into account. It was applied to Eu-152 and Cs-134 volume sources of 9 different densities, whilst the effect of the source's density on the TCC factor was investigated. There are differences between current results and the ones calculated by the TrueCoinc software. A relative bias up to 15% was observed, while the mean relative bias was 4.5%. The different approaches between the two codes could explain these deviations.


Assuntos
Radioisótopos de Césio , Radiometria , Radiometria/métodos , Software , Método de Monte Carlo
4.
Appl Radiat Isot ; 155: 108921, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31629294

RESUMO

An internal consistency test of the calculation of coincidence-summing correction factors FC for volume sources is presented. The test is based on exact equations relating the values of FC calculated for three ideal measurement configurations. The test is applied to a number of 33 sets of FC values sent by 21 teams. Most sets passed the test, but not the results obtained using the quasi-point source approximation; in the latter case the test qualitatively indicated the magnitude of the bias of FC.

5.
Appl Radiat Isot ; 154: 108850, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31476556

RESUMO

Monte Carlo (MC) simulation is widely used in gamma-ray spectrometry, however, its implementation is not always easy and can provide erroneous results. The present action provides a benchmark for several MC software for selected cases. The examples are based on simple geometries, two types of germanium detectors and four kinds of sources, to mimic eight typical measurement conditions. The action outputs (input files and efficiency calculation results, including practical recommendations for new users) are made available on a dedicated webpage.

6.
Appl Radiat Isot ; 87: 361-4, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24315283

RESUMO

This paper presents the Compton Suppression System, recently installed at the Nuclear Engineering Department of NTUA. The system consists of an XtRa Ge detector coupled with a NaI(Tl) guard detector. The electronic set-up allows for the simultaneous collection of both the suppressed and the unsuppressed spectra. System performance is investigated using certified point and volume sources. Parameters such as Peak Suppression Factors, peak-to-Compton ratios and minimum detectable activity for specific radionuclides are determined.

7.
Radiat Prot Dosimetry ; 156(4): 465-74, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23604742

RESUMO

The radionuclides released during the accident at the Fukushima Daichii nuclear power plant following the Tohoku earthquake and tsunami on 11 March 2011 were dispersed in the whole north hemisphere. Traces of (131)I, (134)Cs and (137)Cs reached Greece and were detected in air, grass, sheep milk, ground deposition, rainwater and drainage water. Members of Six Greek laboratories of the national network for environmental radioactivity monitoring have collaborated with the Greek Atomic Energy Commission (GAEC) and carried out measurements during the time period between 11 March 2011 and 10 May 2011 and reported their results to GAEC. These laboratories are sited in three Greek cities, Athens, Thessaloniki and Ioannina, covering a large part of the Greek territory. The concentrations of the radionuclides were studied as a function of time. The first indication for the arrival of the radionuclides in Greece originating from Fukushima accident took place on 24 March 2011. After 28 April 2011', concentrations of all the radionuclides were below the minimum detectable activities (<10 µBq m(-3) for (131)I). The range of concentration values in aerosol particles was 10-520 µBq m(-3) for (131)I, 10-200 µBq m(-3) for (134)Cs and 10-200 µBq m(-3) for (137)Cs and was 10-2200 µBq m(-3) for (131)I in gaseous phase. The ratios of (131)I/(137)Cs and (134)Cs/(137)Cs concentrations are also presented. For (131)I, the maximum concentration detected in grass was 2.2 Bq kg(-1). In the case of sheep milk, the maximum concentration detected for (131)I was 2 Bq l(-1). Furthermore, more than 200 samples of imported foodstuff have been measured in Greece, following the EC directives on the inspection of food and feeding stuffs.


Assuntos
Contaminação Radioativa de Alimentos/análise , Acidente Nuclear de Fukushima , Monitoramento de Radiação/métodos , Ar , Poluentes Radioativos do Ar/análise , Animais , Bovinos , Radioisótopos de Césio/análise , Exposição Ambiental/análise , Geografia , Grécia , Humanos , Radioisótopos do Iodo/análise , Leite , Controle de Qualidade , Doses de Radiação , Poluentes Radioativos/análise , Análise de Regressão , Ovinos , Espectrometria gama/métodos , Fatores de Tempo
8.
Appl Radiat Isot ; 70(9): 2112-8, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22445105

RESUMO

The second part of an intercomparison of the coincidence summing correction methods is presented. This exercise concerned three volume sources, filled with liquid radioactive solution. The same experimental spectra, decay scheme and photon emission intensities were used by all the participants. The results were expressed as coincidence summing corrective factors for several energies of (152)Eu and (134)Cs, and different source-to-detector distances. They are presented and discussed.


Assuntos
Algoritmos , Artefatos , Radioisótopos/análise , Radioisótopos/normas , Radiometria/métodos , Radiometria/normas , Espectrometria gama/métodos , Meia-Vida , Internacionalidade , Doses de Radiação , Radioisótopos/química , Padrões de Referência , Valores de Referência
9.
Appl Radiat Isot ; 69(8): 1151-5, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21193317

RESUMO

In the case of a nuclear or radiological accident a rapid estimation of the qualitative and quantitative characteristics of the potential radioactive pollution is needed. For aerial releases the radioactive pollutants are finally deposited on the ground forming a surface source. In this case, in-situ γ-ray spectrometry is a powerful tool for the determination of ground pollution. In this work, the procedure followed at the Nuclear Engineering Department of the National Technical University of Athens (NED-NTUA) for the calibration of an in-situ Broad Energy Germanium (BEGe) detector, for the determination of gamma-emitting radionuclides deposited on the ground surface, is presented. BEGe detectors due to their technical characteristics are suitable for the analysis of photons in a wide energy region. Two different techniques were applied for the full-energy peak efficiency calibration of the BEGe detector in the energy region 60-1600 keV: Full-energy peak efficiencies determined using the two methods agree within statistical uncertainties.


Assuntos
Monitoramento Ambiental/instrumentação , Germânio/análise , Método de Monte Carlo , Poluentes Radioativos do Solo/química , Calibragem , Monitoramento Ambiental/métodos , Fótons , Espectrometria gama
10.
J Hazard Mater ; 181(1-3): 255-62, 2010 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-20605322

RESUMO

The concentration of trace elements and radionuclides in fly ash particles of different size can exhibit significant variation, due to the various processes taking place during combustion inside a coal-fired power plant. An investigation of this effect has been performed by analyzing samples of fly ash originating in two different coal-fired power plants, after separation into size fractions by sieving. The samples were analyzed by gamma-ray spectrometry, including low-energy techniques, radon exhalation measurement and instrumental neutron activation analysis for the determination of Al, As, Ga, K, La, Na, Mn, Mg, Sr, Sc, and V. Variations are observed in the results of various samples analyzed, while the activity balances calculated from the results of individual size fractions are consistent with those of the raw ash samples. Correlations among the radionuclides examined are also observed, while individual nuclide behavior varies between the two types of fly ash examined.


Assuntos
Carbono/análise , Metais/análise , Análise de Ativação de Nêutrons/métodos , Material Particulado/análise , Carvão Mineral , Cinza de Carvão , Radioisótopos/análise
11.
Appl Radiat Isot ; 68(7-8): 1407-12; discussion 1412, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20117939

RESUMO

A comparison of the coincidence summing correction methods is presented. Since there are several ways for computing these corrections, each method has advantages and drawbacks that could be compared. This part of the comparison was restricted to point sources. The same experimental spectra, decay scheme and photon emission intensities were used by all the participants. The results were expressed as coincidence summing correction factors for several energies of (152)Eu and (134)Cs, and three source-to-detector distances. They are presented and discussed.

12.
Appl Radiat Isot ; 68(7-8): 1435-7, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19954990

RESUMO

Aim of this work is to study the effect of various simulation parameters on the calculation of the full energy peak efficiency of HPGe detectors with the Monte Carlo simulation code PENELOPE.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...