Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 61(5): 793-7, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15308146

RESUMO

The gamma dose determination using thermoluminescent (TL) dosimeters in mixed neutron-gamma fields, such as in boron neutron capture therapy (BNCT), is difficult due to the thermal neutron sensitivity of the detectors; especially when equipment capable of glow curve analysis is not available. The two TL analysis methods used previously in Finnish BNCT to correct the measured TL signal to obtain absorbed gamma dose in vivo were studied and compared, and an enhanced method was introduced. The three TL methods were found surprisingly consistent despite, e.g. the rough estimate made in the first method.


Assuntos
Terapia por Captura de Nêutron de Boro , Dosimetria Termoluminescente/métodos , Terapia por Captura de Nêutron de Boro/instrumentação , Terapia por Captura de Nêutron de Boro/estatística & dados numéricos , Finlândia , Raios gama/uso terapêutico , Humanos , Dosagem Radioterapêutica , Dosimetria Termoluminescente/estatística & dados numéricos
2.
Phys Med Biol ; 48(17): 2895-906, 2003 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-14516107

RESUMO

Polymer gels have been reported as a new, potential tool for dosimetry in mixed neutron-gamma radiation fields. In this work, BANG-3 (MGS Research Inc.) gel vials from three production batches were irradiated with 6 MV photons of a Varian Clinac 2100 C linear accelerator and with the epithermal neutron beam of the Finnish boron neutron capture therapy (BNCT) facility at the FiR 1 nuclear reactor. The gel is tissue equivalent in main elemental composition and density and its T2 relaxation time is dependent on the absorbed dose. The T2 relaxation time map of the irradiated gel vials was measured with a 1.5 T magnetic resonance (MR) scanner using spin echo sequence. The absorbed doses of neutron irradiation were calculated using DORT computer code, and the accuracy of the calculational model was verified by measuring gamma ray dose rate with thermoluminescent dosimeters and 55Mn(n,gamma) activation reaction rate with activation detectors. The response of the BANG-3 gel dosimeter for total absorbed dose in the neutron irradiation was linear, and the magnitude of the response relative to the response in the photon irradiation was observed to vary between different gel batches. The results support the potential of polymer gels in BNCT dosimetry, especially for the verification of two- or three-dimensional dose distributions.


Assuntos
Terapia por Captura de Nêutron de Boro/instrumentação , Géis , Polímeros , Radiometria/instrumentação , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/instrumentação , Terapia por Captura de Nêutron de Boro/métodos , Relação Dose-Resposta à Radiação , Análise de Falha de Equipamento , Nêutrons/uso terapêutico , Doses de Radiação , Radiometria/normas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...