Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Spectrosc ; 74(5): 525-535, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32167375

RESUMO

The application assessment of different programs was performed with equivalence tests for method transfer pro second-order derivative spectrophotometry. The digital second-order derivative spectra were calculated on different instruments; GBC Scientific Equipment Cintra 20 (Cintral v.2.6 and Spectral v.1.70 software programs) and Thermo Scientific Evolution 300 (VISIONPro software) were analyzed using the amplitude A/B ratio (A = 2D265,263; B = 2D263,261). Amplitude A/B ratio is the resolution parameter for derivative spectrophotometry prescribed in European Pharmacopoeia. The obtained values for A/B ratio were either very similar or significantly different among programs: 0.669 (Cintral v.2.6), 0.549 (Spectral v.1.70), 0.556 (medium indirect VISIONPro), 0.557 (one-step Savitzky-Golay 7 VISIONPro), 0.689 (two-step Savitzky-Golay 7 VISIONPro). Method transfer was possible between Spectral v.1.70 and VISIONPro (medium indirect and one-step Savitzky-Golay 7), but the values obtained in Cintral v.2.6 were not comparable to the other programs. The absorbance data exported from both instruments were additionally calculated in OriginPro8 which provided almost the same mean A/B values (0.627 Cintral v.2.6; 0.624 VISIONPro), confirming that the two instruments recorded the same zero-order spectra. The calculation of resolution parameter could be used for verification of program comparison, which would enable transfer between sender and receiver laboratory. The accordance between program algorithms was confirmed when acceptable differences for values of resolution parameter (A/B ratios) were achieved.

2.
J Chromatogr Sci ; 53(10): 1780-5, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26123666

RESUMO

Twelve angiotensin-converting enzyme (ACE) inhibitors were studied to evaluate correlation between their absorption (ABS) data available in the literature (22-96%) and hydrophobicity parameters (km and Pm/w) obtained in micellar thin-layer chromatography (MTLC) using Brij 35. The theoretical considerations showed that the geometric molecular descriptor-volume value (Vol) should be considered as an independent variable simultaneously with calculated hydrophobicity parameters in multiple linear regression analysis to obtain reliable correlation between ACE inhibitor's absorption and lipophilicity (calculated KOWWINlog P) and that captopril should be excluded from further correlations. The results of MTLC confirmed that between the two hydrophobicity parameters km and Pm/w, for absorption prediction of 11 ACE inhibitors, the micelle-water partition coefficient Pm/w provided higher correlation (R(2) = 0.756), while for the km parameter R(2) = 0.612 was obtained. The micelle-water partition coefficient Pm/w could be considered as analogous to hydrophobicity parameter C0 from reversed-phase thin-layer chromatography. Dissimilar retention behavior of lisinopril indicated its lowest non-polar interaction with micelle, because of its di-acid form. The proposed model which included ACE inhibitors on the opposite site of lipophilicity-lisinopril and fosinopril (KOWWINlog P = -0.96 and KOWWINlog P = 6.61, respectively), both with similar absorption values (25 and 36%, respectively), could indicate that absorption of investigated compounds occurs via two different mechanisms: active and passive transport.


Assuntos
Inibidores da Enzima Conversora de Angiotensina/química , Cromatografia em Camada Fina/métodos , Micelas
3.
Artigo em Inglês | MEDLINE | ID: mdl-26112102

RESUMO

Inter-laboratory verification of European pharmacopoeia (EP) monograph on derivative spectrophotometry (DS) method and its application for chitosan hydrochloride was carried out on two generation of instruments (earlier GBC Cintra 20 and current technology TS Evolution 300). Instruments operate with different versions of Savitzky-Golay algorithm and modes of generating digital derivative spectra. For resolution power parameter, defined as the amplitude ratio A/B in DS method EP monograph, comparable results were obtained only with algorithm's parameters smoothing points (SP) 7 and the 2nd degree polynomial and those provided corresponding data with other two modes on TS Evolution 300 Medium digital indirect and Medium digital direct. Using quoted algorithm's parameters, the differences in percentages between the amplitude ratio A/B averages, were within accepted criteria (±3%) for assay of drug product for method transfer. The deviation of 1.76% for the degree of deacetylation assessment of chitosan hydrochloride, determined on two instruments, (amplitude (1)D202; the 2nd degree polynomial and SP 9 in Savitzky-Golay algorithm), was acceptable, since it was within allowed criteria (±2%) for assay deviation of drug substance, for method transfer in pharmaceutical analyses.


Assuntos
Quitosana/química , Acetilação , Algoritmos , Espectrofotometria , Espectrofotometria Ultravioleta
4.
Artigo em Inglês | MEDLINE | ID: mdl-24583202

RESUMO

Set of nine angiotensin-converting enzyme inhibitors (enalapril, quinapril, fosinopril, lisinopril, cilazapril, ramipril, benazepril, perindopril and moexipril) were studied to evaluate the correlation between their intestinal absorption and salting-out thin-layer chromatography hydrophobicity parameters (RM(0) or C0) obtained by ascending technique applying four different salts, (NH4)2SO4, NH4NO3, NH4Cl and NaCl as mobile phases. The best correlations between KOWWIN logP and both hydrophobicity parameters, RM(0) and C0, (R(2)>0.850) were observed for NaCl (1.0-3.0M) while the lowest R(2) was obtained for (NH4)2SO4 (0.649 and 0.427, respectively) due to highest salting-out effect of (NH4)2SO4. The effect of selected inorganic salts in the salting-out mobile phases, on the solutes solubility and retention was evaluated. The topological polar surface area should be selected as independent variable (only this molecular descriptor showed low correlation with chromatographic hydrophobicity parameters) for multiple linear regression analysis, to obtain reliable correlation between angiotensin-converting enzyme inhibitor's intestinal absorption data and salting-out thin-layer chromatograpic hydrophobicity parameters. These correlations provide R(2)=0.823 for RM(0) or R(2)=0.799 for C0 indicating good relationship between predicted and literature available intestinal absorption (ranged from 22% to 70%) of investigated angiotensin-converting enzyme inhibitors. The proposed in vitro model was checked with three in addition experimentally analyzed drugs, zofenopril, trandolapril and captoril. The satisfactory absorption prediction was obtained for zofenopril and trandolapril, while divergence established for captopril resulted from considerably different structure.


Assuntos
Inibidores da Enzima Conversora de Angiotensina/análise , Inibidores da Enzima Conversora de Angiotensina/metabolismo , Cromatografia em Camada Fina/métodos , Absorção , Inibidores da Enzima Conversora de Angiotensina/química , Interações Hidrofóbicas e Hidrofílicas , Modelos Químicos , Sais
5.
J Chromatogr A ; 1258: 94-100, 2012 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-22939460

RESUMO

In this research seven ACE inhibitors (enalapril, quinapril, fosinopril, lisinopril, cilazapril, ramipril, benazepril) were studied to evaluate the correlation between their absorption and ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS) and reversed-phase thin-layer chromatography (RP-TLC) hydrophobicity data (φ(0) or C(0) parameters, respectively). Their absorption values were in the range of 25-60%, while calculated KOWWIN logP values were from -0.94 to 6.61. Additionally, perindopril (absorption 70%, KOWWIN logP 2.59) and moexipril (absorption 22%, KOWWIN logP 3.36) were introduced for the theoretical considerations due to their high/low absorption values which were on the opposite sites in comparison with the majority of ACE inhibitors (25-60%). In the theoretical considerations it was shown that the solubility data (logS) must be considered, as independent variable, simultaneously with KOWWIN logP to obtain reliable correlation (r(2)=0.7208) between absorption and ACE inhibitors lipophilicity. As the main topic of this study, the relationships between literature available and absorption data predicted by multiple linear regression (MLR) using logS values besides chromatographically obtained hydrophobicity parameters C(0) (r(2)=0.6424) or φ(0) (r(2)=0.6762) were studied proving that these parameters could be used in ACE inhibitors absorption evaluation. The UHPLC-MS method provides the direct application of experimentally obtained φ(0) values that is the advantage of this method. For better MLR correlation of ACE inhibitors absorption with C(0) parameters (RP-TLC) and logS, mathematical conversion of C(0) parameters to logC(0) values was necessary based on requisite for probability value of regression analysis (P<0.05). The accordance and differences between hydrophobicity parameters obtained by UHPLC-MS and RP-TLC were defined.


Assuntos
Inibidores da Enzima Conversora de Angiotensina/química , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia de Fase Reversa/métodos , Espectrometria de Massas em Tandem/métodos , Absorção , Inibidores da Enzima Conversora de Angiotensina/análise , Inibidores da Enzima Conversora de Angiotensina/farmacocinética , Humanos , Interações Hidrofóbicas e Hidrofílicas , Modelos Lineares
6.
Molecules ; 17(1): 480-91, 2012 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-22222907

RESUMO

The permeation properties of twenty newly synthesized α-alkoxyalkanoyl and α-aryloxyalkanoyl C-21 esters of standard corticosteroids: Fluocinolone acetonide, dexamethasone, triamcinolone acetonide and hydrocortisone were established using a PAMPA assay (70% silicone oil and 30% isopropyl myristate). The data were compared with parent corticosteroids with addition of mometasone furoate and hydrocortisone acetate. All newly synthesized corticosteroid C-21 esters have effective permeability coefficients higher then -6, mostly followed with high values of retention factors and low permeation. The examined compounds were grouped through relationship between obtained retention factors and permeation parameters (groups I-III). The classification confirmed group I (membrane retentions as well as permeation lower then 30%) for all corticosteroid standards except mometasone furoate, a potent topical corticosteroid which, with high membrane retention (81%) and low permeation (7.7%) fits into group III. The largest number of new synthesized corticosteroids C-21 esters, among them all fluocinolone acetonide C-21 esters, have high membrane retentions (32.4%-86.5%) and low permeations (1.3%-27.1%), fitting in group III. The classification was related to previously obtained anti-inflammatory activity data for the fluocinolone acetonide C-21 esters series. According to the PAMPA results the new synthesized esters could be considered as potential new prodrugs with useful benefit/risk ratio.


Assuntos
Ésteres/química , Membranas Artificiais , Modelos Biológicos , Pregnanos/química , Pró-Fármacos/química , Ésteres/síntese química , Ésteres/normas , Humanos , Miristatos/química , Permeabilidade , Pregnanos/síntese química , Pregnanos/normas , Pró-Fármacos/síntese química , Pró-Fármacos/normas , Padrões de Referência , Óleos de Silicone/química , Absorção Cutânea
7.
Iran J Pharm Res ; 11(3): 763-70, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-24250503

RESUMO

In this assay, the evaluation of lipophilicity of four ACE-inhibitors and hydrochlorothiazide (HCTZ) with RP-TLC on cellulose layers was described using three binary solvent systems. The selected ACE inhibitors had sufficiently different structures which can indicate the method suitability for their lipophilicity evaluation as the model substances in comparison with HCTZ. In addition, the linear relationship between the RM-values and composition of mobile phases was established in the current study. From the regression data of the plots, the hydrophobicity parameters, R(0) M and m, were determined and C0 parameter was calculated. The correlations between the experimentally obtained hydrophobicity parameters and calculated log p values were studied. Furthermore, the obtained results were compared with those previously obtained on RP-18 modified silica gel. Very good correlation (r = 0.91; water-ethanol solvent system) between the chromatographically obtained hydrophobicity parameters and calculated log p values confirmed the selection of ACE inhibitors since lisinopril and quinapril were on the opposite sites of linear relationship. The results indicate that cellulose as an easily available sorbent can be successfully used for the lipophilicity investigation of examined substances with RP-TLC.

8.
Molecules ; 16(3): 2658-71, 2011 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-21441868

RESUMO

In this study the solvolysis of newly synthesized fluocinolone acetonide C-21 esters was analysed in comparison with fluocinonide during a 24-hour period of time. The solvolysis was performed in an ethanol-water (90:10 v/v) mixture using the excess of NaHCO3. The solvolytic mixtures of each investigated ester have been assayed by a RP-HPLC method using isocratic elution with methanol-water (75:25 v/v); flow rate 1 mL/min; detection at 238 nm; temperature 25 °C. Solvolytic rate constants were calculated from the obtained data. Geometry optimizations and charges calculations were carried out by Gaussian W03 software. A good correlation (R = 0.9924) was obtained between solvolytic rate constants and the polarity of the C-O2 bond of those esters. The established relation between solvolytic rate constant (K) and lipophilicity (cLogP) with experimental anti-inflammatory activity could be indicative for topical corticosteroid prodrug activation.


Assuntos
Fluocinolona Acetonida/química , Pró-Fármacos/farmacocinética , Ésteres , Cinética , Solventes
9.
Artigo em Inglês | MEDLINE | ID: mdl-20044302

RESUMO

A novel topical corticosteroid FA-21-PhP, 2-phenoxypropionate ester of fluocinolone acetonide, has been synthesized in order to investigate the possibility of decreasing systemic side effects. In this study model system for in vitro solvolytic reaction of FA-21-PhP has been analyzed in ethanol/water (90:10, v/v) with excess of sodium hydrogen carbonate. The selected conditions have been used as in vitro model for activation of corticosteroid C-21 ester prodrug. The second-order derivative spectrophotometric method (DS) using zero-crossing technique was developed for monitoring ternary mixture of solvolysis. Fluocinolone acetonide (FA) as a solvolyte was determined in the mixture in the concentration range 0.062-0.312 mM using amplitude (2)D(274.96). Experimentally determined LOD value was 0.0295 mM. The accuracy of proposed DS method was confirmed with HPLC referent method. Peak area of parent ester FA-21-PhP was used for solvolysis monitoring to ensure the initial stage of changes. Linear relationship in HPLC assay for parent ester was obtained in the concentration range 0.054-0.54 mM, with experimentally determined LOD value of 0.0041 mM. Investigated solvolytic reaction in the presence of excess of NaHCO(3) proceeded via a pseudo-first-order kinetic with significant correlation coefficients 0.9891 and 0.9997 for DS and HPLC, respectively. The values of solvolysis rate constant calculated according to DS and HPLC methods are in good accordance 0.038 and 0.043 h(-1), respectively.


Assuntos
Fluocinolona Acetonida/química , Solventes/química , Espectrofotometria Ultravioleta , Cromatografia Líquida de Alta Pressão
10.
Electrophoresis ; 29(21): 4431-8, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18956436

RESUMO

A novel and simple method has been developed for the determination of doxycycline (DOX) in biological fluids. The method is based on SPE, large-volume sample stacking (LVSS) and MEKC with UV-DAD detection. Six SPE cartridges have been used in investigation for sample clean up and pre-concentration (Supelco LC-8, LC-18, LC-SCX, and LC-WCX, as well as Strata-X and X-C). DOX was determined on a 56 cm (effective length 50 cm) x 50 microm id fused-silica capillary. The BGE was 20 mM borate buffer, pH 9.3, containing 80 mM SDS and 7.5% v/v of methanol (30 sx50 mbar), and the temperature and voltage were 25 degrees C and 30 kV, respectively. The analytical wavelength was set at 210 nm. Under optimized conditions it is possible to determine DOX in human serum, urine, semen, tears and saliva with recovery of 97.5% (RSD 2.5%). The method was shown to be sensitive (LOD is 1 microg/L) and precise (intra-day RSD 0.2 and 2.4%; inter-days 0.4 and 3.5% for migration time and peak area, respectively). Results for developed SPE-LVSS-MEKC were compared with LVSS-MEKC method with direct sample injection. The new LVSS-MEKC method is presented as a useful technique for rapid determination without extraction procedure of DOX in human urine and serum, using 80 mM of SDS, 10% v/v of methanol and 40 mM borate buffer (pH 9.3; 30 s x 50 mbar; 25 degrees C; 30 kV; 350 nm), but not for the other biological fluids, according to lower sensitivity of the method and because of the sample composition.


Assuntos
Antibacterianos/análise , Líquidos Corporais/química , Doxiciclina/análise , Adulto , Antibacterianos/sangue , Antibacterianos/urina , Cromatografia Capilar Eletrocinética Micelar/métodos , Doxiciclina/sangue , Doxiciclina/urina , Humanos , Masculino , Saliva/química , Sêmen/química , Extração em Fase Sólida , Lágrimas/química
11.
Artigo em Inglês | MEDLINE | ID: mdl-18348041

RESUMO

A separation technique for zinc bacitracin, polymyxin B, oxytetracycline and sulfacetamide in animal feedstuffs by micellar electrokinetic capillary chromatography (MEKC) was developed. The running buffer was 20 mmol l(-1) borate, 20 mmol l(-1) phosphate, pH 8.4, containing 20 mmol l(-1) sodium dodecylsulphate and 10% (v/v) methanol. MEKC was performed at 25 degrees C; the applied voltage was 25 kV with a running pressure of 10 mbar. Simultaneous UV detection for all analytes was at 215 nm. The method was validated for specificity, accuracy, linearity, precision and robustness. It was shown to be specific, accurate (recoveries were 99.7 +/- 0.3, 99.9 +/- 0.9, 99.8 +/- 1.0 and 99.5 +/- 0.4, respectively, for oxytetracycline-, sulfacetamide-, polymyxin B- and zinc bacitracin-spiked samples of feed for cow, pigs, chicken and cattle), linear over the tested range (correlation coefficients > or =0.9987) and precise (RSDs below 1.8% for each analyte). The method was applied to determine zinc bacitracin, polymyxin B, oxytetracycline and sulfacetamide as additives in animal feed.


Assuntos
Ração Animal/análise , Antibacterianos/análise , Cromatografia Capilar Eletrocinética Micelar/métodos , Oxitetraciclina/análise , Peptídeos Cíclicos/análise , Sulfacetamida/análise , Animais , Bovinos , Galinhas , Aditivos Alimentares , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos
12.
J Chromatogr Sci ; 46(2): 137-43, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18366873

RESUMO

A method is described for quantitating caffeine, theobromine, theophylline, paracetamol, propyphenazone, acetylsalicylic acid, salicylic acid, and codeine phosphate in corresponding real samples of food, beverages, natural products, pharmaceuticals, and cosmetic preparations by micellar electrokinetic capillary chromatography. The separation is carried out at 25 degrees C and 25 kV, using a 20 mM phosphate buffer (pH 9.0), 80 mM sodium dodecyl sulfate, and 7.5% (v/v) acetonitrile. UV detection is at 210 nm. The method is shown to be specific, accurate (recoveries over the range 98.9-101.2%), linear over the tested range (correlation coefficients>or=0.9993), and precise (relative standard deviation below 2.1%). The method is applied for the quantitative analysis of these compounds in different foods, beverages, natural products, pharmaceuticals, and cosmetic products.


Assuntos
Bebidas/análise , Produtos Biológicos/química , Cafeína/análise , Cromatografia Capilar Eletrocinética Micelar/métodos , Cosméticos/química , Análise de Alimentos/métodos , Preparações Farmacêuticas/química , Acetaminofen/análise , Antipirina/análogos & derivados , Antipirina/análise , Aspirina/análise , Codeína/análise , Modelos Lineares , Ácido Salicílico/análise , Teobromina/análise , Teofilina/análise
13.
J Sep Sci ; 29(9): 1288-93, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16833088

RESUMO

An MEKC procedure was developed for the separation of zinc bacitracin (Zn-BC) and nystatin (NYS) in mixtures and in animal feedstuff. The running buffer was 15 mM borate/19 mM phosphate, pH 8.2, containing 20 mM SDS and 10% v/v methanol. Samples were run at 25 degrees C, the applied voltage was 25 kV, and an additional pressure of 5 mbar was applied. Both analytes were detected by UV simultaneously at 215 nm, Zn-BC alone at 192 and 254 nm, and NYS alone at 305 nm. The method was shown to be specific, accurate (recoveries were 100.0 +/- 0.6% and 100.1 +/- 0.6% for Zn-BC and NYS, respectively), linear over the tested range (correlation coefficients 0.9991 and 0.9994), and precise (RSD below 1.3% for both analytes). The method was applied to determine Zn-BC and NYS as additives in animal feed.


Assuntos
Ração Animal , Antibacterianos/análise , Bacitracina/análise , Cromatografia Capilar Eletrocinética Micelar/métodos , Nistatina/análise , Animais , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Biopharm Drug Dispos ; 24(7): 309-14, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14520684

RESUMO

Paracetamol is a widely used nonsalicylate analgesic and antipyretic drug. The existing methods for the determination of paracetamol in biological fluids are mainly HPLC techniques, although there are some reported methods based on spectrophotometric determinations. However, all these methods involve some extraction or derivatisation procedures. In the present study the UV spectra of investigated samples were recorded over the wavelength range 220-400 nm (lambda step 0.21 nm; scan speed 60 nm/min) and second-order derivative spectra were calculated. Second-order derivative spectra of different blank urine samples displayed the presence of a zero-crossing point at 245-247 nm defined as lambdazc. The zero-order absorption spectra of paracetamol in water displays maximum absorbance at 243 nm, while in second derivative spectra, a minimum peak at 246 nm was observed. Therefore, the application of zero-crossing technique to the second-derivative UV absorption spectrum should be useful for the determination of paracetamol using 2Dlambdazc. The proposed method enables determination of total paracetamol in urine directly and simply by reading the 2Dlambdazc of the diluted samples. The obtained results were in good accordance with published data on cumulative urinary excretion after per oral administration of paracetamol obtained applying different spectrophotometric methods of determination. It could be useful for biopharmaceutical characterisation of drug products (monitoring of the levels of paracetamol in urine in bioavailability testing, for the evaluation of in vitro-in vivo correlation and screening of different formulations during drug product development).


Assuntos
Acetaminofen/urina , Tecnologia Farmacêutica/métodos , Biofarmácia , Humanos , Espectrofotometria Ultravioleta/métodos , Tecnologia Farmacêutica/instrumentação
15.
J Pharm Biomed Anal ; 32(4-5): 929-35, 2003 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-12899979

RESUMO

The photochemical degradation of solid-state nisoldipine, 1,4-dihydropyridine calcium antagonist, was investigated under daylight and UV light conditions. Degradation products were identified by using the retention times of corresponding standards and quantified by high-performance liquid chromatographic method. The daylight illumination induced appearance of nitrosophenylpyridine, while formation of second degradation product, nitrophenylpyridine, was observed only upon UV light illumination. The photodegradation kinetics of solid-state nisoldipine under daylight and UV light illumination belongs to class of zero-order reactions. The rate constants of disappearance of nisoldipine upon illumination were determined for raw material as well as pharmaceuticals (tablets, film-tablets and capsules).


Assuntos
Luz/efeitos adversos , Nisoldipino/análise , Nisoldipino/metabolismo , Tecnologia Farmacêutica/métodos , Raios Ultravioleta/efeitos adversos , Cromatografia Líquida de Alta Pressão/métodos , Nisoldipino/química , Fotoquímica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...