Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Chim Slov ; 62(1): 196-203, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25830976

RESUMO

A novel ion pair-dispersive liquid-liquid microextraction (IP-DLLME) of gold followed by its determination with microsample injection system-flame atomic absorption spectrometry (MIS-FAAS) detection was developed. The extraction method was based on the reaction of anionic tetrachloro gold(III) complex with the cationic form of Rhodamine B to give a violet ion pair complex, which is extracted from 1.0 mol L(-1) HCl solution of 8.0 mL to fine droplets of chloroform of 500 µL. A Plackett-Burman experimental design of MINITAB statistical program was employed to optimize the influence of main parameters to be controlled in DLLME. After optimizing the extraction conditions, gold was quantitatively recovered by preconcentration factor of 40, limit of detection (LOD) of 1.8 µg L(-1) and relative standard deviation of less than 6.8%. The proposed method was successfully applied to the preconcentration and determination of gold in some samples such as tap water, waste water, copper electrolysis solution and copper wire coated nickel.


Assuntos
Análise de Injeção de Fluxo , Ouro/análise , Microextração em Fase Líquida , Rodaminas/química , Espectrofotometria Atômica
2.
Acta Chim Slov ; 60(4): 901-7, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24362996

RESUMO

Chromosorb-105 resin/1-(2-pyridylazo)-2-naphthol (PAN) system was developed for solid phase chelate extractive preconcentration of heavy metal ions. The metal ions on Chromosorb-105 resin column were eluted with 3.0 mL of 2.0 mol L-1 HNO3 and determined by microsample injection system coupled flame atomic spectrometry (MIS-FAAS) using 75.0 µL of sample solution for single element determination. The influence of pH, resin amount, reagent amount, flow rate and volume of eluent and sample solution was optimized. The quantitative recoveries (≥95%) of Fe(III), Zn(II), Cu(II) and Pb(II) ions were achieved at pH 9; resin amount, 700 mg; reagent amount, 6.0 µmol; flow rate of eluent and sample solution, 1.0 mL min-1 and 5.0 mL min-1, respectively. The limit of detection and limit of quantification of understudied analytes were found to be 0.17-1.74 µg L-1 and 0.40-2.98 µg L-1, respectively with preconcentration factor of 150-300. The proposed method was validated by analysis of waste water (BCR-715) as a certified reference material. The method was applied successfully for ultratrace determination of studied metal ions in tap water and hot spring water samples.


Assuntos
Quelantes/química , Análise de Injeção de Fluxo/instrumentação , Metais Pesados/análise , Extração em Fase Sólida , Espectrofotometria Atômica , Humanos , Metais Pesados/química , Águas Residuárias/análise , Poluentes Químicos da Água/análise
3.
J Hazard Mater ; 145(3): 459-64, 2007 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-17175100

RESUMO

A method for separation-preconcentration of Pb(II), Cr(III), Cu(II), Ni(II) and Cd(II) ions by membrane filtration has been described. The method based on the collection of analyte metal ions on a cellulose nitrate membrane filter and determination of analytes by flame atomic absorption spectrometry (FAAS). The method was optimized for several parameters including of pH, matrix effects and sample volume. The recoveries of analytes were generally in the range of 93-100%. The detection limits by 3 sigma for analyte ions were 0.02microgL(-1) for Pb(II), 0.3microgL(-1) for Cr(III), 3.1microgL(-1) for Cu(II), 7.8microgL(-1) for Ni(II) and 0.9microgL(-1) for Cd(II). The proposed method was applied to the determination of lead, chromium, copper, nickel and cadmium in tap waters and RM 8704 Buffalo River Sediment standard reference material with satisfactory results. The relative standard deviations of the determinations were below 10%.


Assuntos
Filtração/métodos , Metais Pesados/análise , Espectrofotometria Atômica , Cádmio/análise , Técnicas de Química Analítica , Cromo/análise , Cobre/análise , Concentração de Íons de Hidrogênio , Chumbo/análise , Níquel/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...