Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Vis ; 21(12): 7, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34783831

RESUMO

The ability to accurately retain the binding between the features of different objects is a critical element of visual working memory. The underlying mechanism can be elucidated by analyzing correlations of response errors in dual-report experiments, in which participants have to report two features of a single item from a previously viewed stimulus array. Results from separate previous studies using different cueing conditions have indicated that location takes a privileged role in mediating binding between other features, in that largely independent response errors have been observed when location was used as a cue, but errors were highly correlated when location was one of the reported features. Earlier results from change detection tasks likewise support such a special role of location, but they also suggest that this role is substantially reduced for longer retention intervals in favor of object-based representation. In the present study, we replicated the findings of previous dual-report tasks with different cueing conditions, using matched stimuli and procedures. Moreover, we show that the observed patterns of error correlations remain qualitatively unchanged with longer retention intervals. Fits with neural population models demonstrate that the behavioral results at long, as well as short, delays are best explained by memory representations in independent feature maps, in which an item's features are bound to each other only via their shared location.


Assuntos
Memória de Curto Prazo , Percepção Visual , Sinais (Psicologia) , Humanos
2.
Cancers (Basel) ; 13(10)2021 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-34067552

RESUMO

Wire-guided localisation (WGL) has been the mainstay for localising non-palpable breast lesions before excision. Due to its limitations, various wireless alternatives have been developed. In this prospective study, we evaluate the role of radiation-free wireless localisation using the SAVI SCOUT® system at the London Breast Institute. A total of 72 reflectors were deployed in 67 consecutive patients undergoing breast conserving surgery for non-palpable breast lesions. The mean interval between deployment and surgery for the therapeutic cases was 18.8 days (range: 0-210). The median deployment duration was 5 min (range: 1-15 min). The mean distance from the lesion was 1.1 mm (median distance: 0; range: 0-20 mm). The rate of surgical localisation and retrieval of the reflector was 98.6% and 100%, respectively. The median operating time was 28 min (range: 15-55 min) for the therapeutic excision of malignancy and 17 min (range: 15-24) for diagnostic excision. The incidence of reflector migration was 0%. Radial margin positivity in malignant cases was 7%. The median weight for malignant lesions was 19.6 g (range: 3.5-70 g). Radiologists and surgeons rated the system higher than WGL (93.7% and 98.6%, respectively; 60/64 and 70/71). The patient mean satisfaction score was 9.7/10 (n = 47, median = 10; range: 7-10). One instance of signal failure was reported. In patients who had breast MRI after the deployment of the reflector, the MRI void signal was <5 mm (n = 6). There was no specific technique-related surgical complication. Our study demonstrates that wire-free localisation using SAVI SCOUT® is an effective and time-efficient alternative to WGL with excellent physician and patient acceptance.

3.
Anticancer Res ; 40(7): 3633-3643, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32620602

RESUMO

BACKGROUND/AIM: With the increase in detection of non-palpable breast lesions through screening, wire-guided localisation (WGL) has long been the favoured method for preoperative localisation. However, this technique comes with several limitations. New methods have been developed, including several non-radioactive, wireless options. We aimed to assess the effectiveness of Savi Scout® localisation (SSL) through this pooled analysis and systematic review. MATERIALS AND METHODS: A number of databases were searched for records reporting data on localisation and retrieval of SSL reflectors, as well as re-excision rate. We included our own data from 20 patients (22 reflectors) at our institution. RESULTS: A total of 842 reflectors were inserted across eleven studies and our own data. Pooled analysis revealed an overall successful deployment rate of 99.64% and a successful retrieval rate of 99.64% using SSL. A statistically significant difference in re-excision rate was found in a smaller pooled analysis conducted across four studies comparing SSL and WGL (12.9% and 21.1% respectively, p<0.01). CONCLUSION: The Savi Scout® localisation system is a safe and effective alternative to WGL. It facilitates flexible scheduling by decoupling radiology and surgery interventions and may reduce the need for re-excision procedures for positive surgical margins.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Mama/diagnóstico por imagem , Mama/patologia , Radiografia/métodos , Feminino , Humanos , Margens de Excisão , Radar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...