Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
J Nucl Cardiol ; 25(3): 911-924, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-27873167

RESUMO

BACKGROUND: The aim of the present study was to compare Emory Cardiac Toolbox, Myovation, and Quantitative Gated SPECT software regarding the automatic measurements of perfusion and functional left ventricular (LV) quantitative parameters, summed stress score (SSS), perfusion defect score, LV ejection fraction (LVEF), end-diastolic volume, and end-systolic volume (ESV). METHODS AND RESULTS: 99mTc-tetrofosmin gated SPECT studies were performed in 634 consecutive patients based on the one-day stress/rest protocol. Participants were divided into subgroups according to heart size (ESV cut-off value: 25 mL), perfusion (SSS >/≤3), and other patient/protocol-related factors. LVEF was categorized as normal (≥50%), mildly moderately impaired (35-49%), and severely abnormal (<35%). The concordance between the packages was good to excellent, in overall population, ESV ≤25 mL, ESV >25 mL, and SSS >3 subgroups (intraclass correlation coefficients, ICCs 0.73-0.93). In SSS ≤3 subgroup, the correlation was excellent for LV functional parameters, but suboptimal for perfusion variables (ICCs 0.30-0.83). LVEF categorization revealed similar variability (discordance 18.1 and 11.1% for stress/rest LVEF values, respectively). Pair comparisons demonstrated considerable differences concerning all parameters for all patient subgroups. The statistical significance of our findings by ESV and SSS classifications was evaluated. CONCLUSIONS: Despite the significant concordance between software packages, considerable differences in mean values of myocardial perfusion and LV functional parameters were demonstrated.


Assuntos
Imagem do Acúmulo Cardíaco de Comporta , Software , Tomografia Computadorizada de Emissão de Fóton Único , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Idoso , Algoritmos , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Volume Sistólico/fisiologia , Tecnécio
2.
Ann Nucl Med ; 29(7): 588-602, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25971450

RESUMO

OBJECTIVE: Estimation of myocardial blood flow (MBF) and coronary flow reserve (CFR) by SPECT myocardial perfusion imaging (MPI) remains challenging. Our aim was to approximate MBF and CFR by quantifying the absolute Tc-99m tetrofosmin retention in the myocardium via gated-SPECT/CT MPI. METHODS: Tracer retention was calculated on the basis of the microsphere kinetic model and served as an index of MBF at stress and rest (sMBFi, rMBFi). CFR was given by the sMBFi/rMBFi ratio. A planar first-pass acquisition during dipyridamole stress and at rest provided the data for tracer input determination. The input was represented by the integral of a gamma variate fitted on the time-activity curve of the left ventricle. Gated-SPECT/CT was performed 1 h post tracer injection and myocardial activity was measured in attenuation-corrected transaxial slices by a threshold VOI. The input was also compensated for tissue attenuation by measuring the distance from the centre of the left ventricle to the body surface on fused SPECT/CT slices. Input and uptake results were adjusted for planar-SPECT counting geometry differences by the aid of a phantom experiment. Thirty-nine subjects with low probability of coronary artery disease (CAD), age lower than 75 years and normal MPI (control group) were compared with 57 patients with documented CAD (CAD group). RESULTS: CFR and sMBFi values of CAD patients (1.39 ± 0.37 and 1.42 ± 0.35 ml/min/g) were considerably lower (p < 0.0001) than controls (1.68 ± 0.25 and 1.72 ± 0.37 ml/min/g). Significant difference in CFR (p = 0.03) was also noted between CAD patients with normal MPI (1.48 ± 0.38) and controls. However, sMBFi managed to discriminate certain CAD subgroups (normal MPI/ischemia/scar/scar and ischemia) more efficiently than CFR. Maximum heart rate-blood pressure product (RPP) during stress was an independent predictor of sMBFi and CFR. The other independent CFR correlates were resting RPP and diabetes mellitus, while sMBFi was associated with age, sex, smoking, and stress perfusion defects. CONCLUSIONS: Despite the low myocardial extraction fraction of Tc-99m tetrofosmin, an approximation of MBF and CFR is feasible with gated-SPECT/CT MPI. These flow indices together were able to discriminate CAD patients from controls and stratify different patient subgroups.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Reserva Fracionada de Fluxo Miocárdico , Coração/fisiopatologia , Imagem Multimodal , Miocárdio/metabolismo , Compostos Organofosforados/metabolismo , Compostos de Organotecnécio/metabolismo , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/metabolismo , Doença da Artéria Coronariana/fisiopatologia , Estudos de Viabilidade , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Descanso , Estresse Fisiológico , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...