Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Acta Cir Bras ; 35(10): e202001004, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33237176

RESUMO

PURPOSE: To modify a surgical catheterization method using the bent needle introducer in small animals. METHODS: Eight-week-old male Lewis rats were used in the study. A needle introducer was created by bending a 21G injection needle at 45°. The bent needle introducer was used for catheter insertion into the left femoral artery of the rats under anesthesia. As a control, a catheter was directly inserted into the blood vessel without the introducer. The insertion time of each method was measured. Blood pressure and heart rate were measured 24 h after catheter insertion using the telemetry system. RESULTS: Using the introducer, the catheter was successfully inserted within a short time in all rats. Without the introducer, a longer duration was required for catheter insertion. The frequency of the insertion with no catheter-based errors with the introducer tended to be higher than that without the introducer. The mean arterial pressure and heart rate 24 h after catheter insertion in each group were almost the same. CONCLUSIONS: We developed a surgical catheterization method using the introducer in small animals. This could potentially reduce the frequency of the insertion with catheter-based errors and insertion time.


Assuntos
Cateterismo , Artéria Femoral , Animais , Artéria Femoral/cirurgia , Masculino , Agulhas , Ratos , Ratos Endogâmicos Lew
2.
Acta cir. bras. ; 35(10): e202001004, 2020. ilus, graf, tab
Artigo em Inglês | VETINDEX | ID: vti-30285

RESUMO

Purpose: To modify a surgical catheterization method using the bent needle introducer in small animals. Methods: Eight-week-old male Lewis rats were used in the study. A needle introducer was created by bending a 21G injection needle at 45°. The bent needle introducer was used for catheter insertion into the left femoral artery of the rats under anesthesia. As a control, a catheter was directly inserted into the blood vessel without the introducer. The insertion time of each method was measured. Blood pressure and heart rate were measured 24 h after catheter insertion using the telemetry system. Results: Using the introducer, the catheter was successfully inserted within a short time in all rats. Without the introducer, a longer duration was required for catheter insertion. The frequency of the insertion with no catheter-based errors with the introducer tended to be higher than that without the introducer. The mean arterial pressure and heart rate 24 h after catheter insertion in each group were almost the same. Conclusions: We developed a surgical catheterization method using the introducer in small animals. This could potentially reduce the frequency of the insertion with catheter-based errors and insertion time.(AU)


Assuntos
Animais , Ratos , Microcirurgia/veterinária , Artéria Femoral/cirurgia , Cateterismo/veterinária
3.
Acta cir. bras ; Acta cir. bras;35(10): e202001004, 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1130612

RESUMO

Abstract Purpose: To modify a surgical catheterization method using the bent needle introducer in small animals. Methods: Eight-week-old male Lewis rats were used in the study. A needle introducer was created by bending a 21G injection needle at 45°. The bent needle introducer was used for catheter insertion into the left femoral artery of the rats under anesthesia. As a control, a catheter was directly inserted into the blood vessel without the introducer. The insertion time of each method was measured. Blood pressure and heart rate were measured 24 h after catheter insertion using the telemetry system. Results: Using the introducer, the catheter was successfully inserted within a short time in all rats. Without the introducer, a longer duration was required for catheter insertion. The frequency of the insertion with no catheter-based errors with the introducer tended to be higher than that without the introducer. The mean arterial pressure and heart rate 24 h after catheter insertion in each group were almost the same. Conclusions: We developed a surgical catheterization method using the introducer in small animals. This could potentially reduce the frequency of the insertion with catheter-based errors and insertion time.


Assuntos
Animais , Masculino , Ratos , Cateterismo , Artéria Femoral/cirurgia , Ratos Endogâmicos Lew , Agulhas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA