Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 876
Filtrar
1.
J Ophthalmic Vis Res ; 19(1): 88-108, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38638634

RESUMO

Glaucoma is the leading cause of irreversible blindness worldwide. Among all glaucoma types, primary angle closure glaucoma (PACG) affects approximately 23 million people worldwide, and is responsible for 50% of glaucoma-related blindness, highlighting the devastating consequences of this disease. The main mechanism of PACG is relative pupillary block. High-risk populations are female gender, Asian ethnicity, high hyperopia, short axial length, and a thick/anteriorly positioned lens. This review discusses the clinical diagnosis, classification, and management of patients with a narrow angle with and without intraocular pressure (IOP) elevation and glaucomatous optic nerve damage, including laser peripheral iridotomy (LPI), endocycloplasty (ECPL), lens extraction, and goniosynechialysis.

2.
Eur J Ophthalmol ; : 11206721241237305, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38470322

RESUMO

PURPOSE: To compare the intraocular pressure (IOP) profile and the incidence of IOP spikes following selective laser trabeculoplasty (SLT) between pigmentary glaucoma (PG) and primary open-angle glaucoma (POAG). MATERIALS AND METHODS: Retrospective comparative study of 65 PG eyes of 51 patients matched with 65 POAG eyes of 65 patients who received SLT. Matching was done based on age, gender, glaucoma severity, pre-laser IOP, and number of medications. Post-SLT IOP spike was defined as IOP elevation ≥5mmHg, 30-45 min after the laser. RESULTS: In PG and POAG groups, the average age was 62.33 ± 9.18 and 62.58 ± 9.19 years (p = 0.95). The glaucoma severity (p = 0.708), baseline IOP (PG = 21.61 ± 1.34mmHg vs. POAG = 21.13 ± 5.09mmHg, p = 0.943), and number of topical glaucoma medications(PG = 2.34 ± 1.34 vs. POAG = 2.1 ± 1.41, p = 0.342) were comparable. More PG patients were on oral acetazolamide (PG = 26.15% vs. POAG = 1.5%, p < 0.001). Average logMAR visual acuity was significantly higher in the POAG group (0.207 ± 0.3 vs. 0.192 ± 0.37, p = 0.012). Eyes with PG received lower laser energy (POAG = 63.65 ± 22.03 mJ vs. PG = 43.71 ± 25.68 mJ, p < 0.001). IOP spikes were recorded in 5 PG eyes (7.6%) and none in the POAG group (p = 0.058). Failure rates were similar (PG = 50.7% and POAG = 43.1%, p = 0.205). In multivariable analysis, only pre-laser IOP (coefficient = 2.154 [CI: 0.765-3.543], p = 0.003) was a significant predictor of IOP change percentage after 12 months. CONCLUSIONS: SLT was comparably effective in both PG and POAG. IOP spikes were observed only in the PG group, though the total laser energy was lower in this group compared with POAG.

3.
Ophthalmol Ther ; 13(4): 995-1014, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38345710

RESUMO

INTRODUCTION: This prospective, multicenter, randomized, double-masked pivotal phase 3 trial evaluated the efficacy and safety of the travoprost intracameral SE-implant (slow-eluting implant, the intended commercial product) and FE-implant (fast-eluting implant, included primarily for masking purposes) compared to twice-daily (BID) timolol ophthalmic solution, 0.5% in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT). METHODS: The trial enrolled adult patients with OAG or OHT with an unmedicated mean diurnal intraocular pressure (IOP) of ≥ 21 and unmedicated IOP ≤ 36 mmHg at each diurnal timepoint (8 A.M., 10 A.M., and 4 P.M.) at baseline. The eligible eye of each patient was administered an SE-implant, an FE-implant or had a sham administration procedure. Patients who received an implant were provided placebo eye drops to be administered BID and patients who had the sham procedure were provided timolol eye drops to be administered BID. The primary efficacy endpoint, for which the study was powered, was mean change from baseline IOP at 8 A.M. and 10 A.M. at day 10, week 6, and month 3. Non-inferiority was achieved if the upper 95% confidence interval (CI) on the difference in IOP change from baseline (implant minus timolol) was < 1.5 mmHg at all six timepoints and < 1 mmHg at three or more timepoints. The key secondary endpoint was mean change from baseline IOP at 8 A.M. and 10 A.M. at month 12. Non-inferiority at month 12 was achieved if the upper 95% CI was < 1.5 mmHg at both timepoints. Safety outcomes included treatment-emergent adverse events (TEAEs) and ophthalmic assessments. RESULTS: A total of 590 patients were enrolled at 45 sites and randomized to one of three treatment groups: 197 SE-implant (the intended commercial product), 200 FE-implant, and 193 timolol. The SE-implant was non-inferior to timolol eye drops in IOP lowering over the first 3 months, and was also non-inferior to timolol at months 6, 9, and 12. The FE-implant was non-inferior to timolol over the first 3 months, and also at months 6 and 9. Of those patients who were on glaucoma medication at screening, a significantly greater proportion of patients in the SE- and FE-implant groups (83.5% and 78.7%, respectively) compared to the timolol group (23.9%) were on fewer topical glaucoma medications at month 12 compared to screening (P < 0.0001, chi-square test). TEAEs, mostly mild, were reported in the study eyes of 39.5% of patients in the SE-implant group, 34.0% of patients in the FE-implant group and 20.1% of patients in the timolol group. CONCLUSIONS: The SE-travoprost intracameral implant demonstrated non-inferiority to timolol over 12 months whereas the FE-implant demonstrated non-inferiority over 9 months. Both implant models were safe and effective in IOP lowering in patients with OAG or OHT. TRIAL REGISTRATION: ClinicalTrials.gov identifier, NCT03519386.

4.
Ophthalmology ; 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38423216

RESUMO

PURPOSE: To evaluate the safety and intraocular pressure (IOP)-lowering efficacy of 2 models of the travoprost intraocular implant (fast-eluting [FE] and slow-eluting [SE] types) from 1 of 2 phase 3 trials (the GC-010 trial). DESIGN: Multicenter, randomized, double-masked, sham-controlled, noninferiority trial. PARTICIPANTS: Patients with open-angle glaucoma or ocular hypertension having an unmedicated baseline mean diurnal IOP (average of 8 am, 10 am, and 4 pm time points) of ≥ 21 mmHg, and IOP of ≤ 36 mmHg at each of the 8 am, 10 am, and 4 pm timepoints at baseline. METHODS: Study eyes were randomized to the travoprost intraocular implant (FE implant [n = 200] or SE implant [n = 197] model) or to timolol ophthalmic solution 0.5% twice daily (n = 193). MAIN OUTCOME MEASURES: The primary outcome was mean change from baseline IOP in the study eye at 8 am and 10 am, at each of day 10, week 6, and month 3. Safety outcomes included adverse events (AEs) and ophthalmic assessments. RESULTS: Mean IOP reduction from baseline over the 6 time points ranged from 6.6 to 8.4 mmHg for the FE implant group, from 6.6 to 8.5 mmHg for the SE implant group, and from 6.5 to 7.7 mmHg for the timolol group. The primary efficacy end point was met; the upper limit of the 95% confidence interval of the difference between the implant groups and the timolol group was < 1 mmHg at all 6 time points. Study eye AEs, most of mild or moderate severity, were reported in 21.5%, 27.2%, and 10.8% of patients in the FE implant, SE implant, and timolol groups, respectively. The most common AEs included iritis (FE implant, 0.5%; SE implant, 5.1%), ocular hyperemia (FE implant, 3.0%; SE implant, 2.6%), reduced visual acuity (FE implant, 1.0%; SE implant, 4.1%; timolol, 0.5%), and IOP increased (FE implant, 3.5%; SE implant, 2.6%; timolol, 2.1%). One serious study eye AE occurred (endophthalmitis). CONCLUSIONS: The travoprost intraocular implant demonstrated robust IOP reduction over the 3-month primary efficacy evaluation period after a single administration. The IOP-lowering efficacy in both implant groups was statistically and clinically noninferior to that in the timolol group, with a favorable safety profile. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

5.
Drugs ; 84(1): 83-97, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38060092

RESUMO

PURPOSE: A randomized, double-masked, multicenter, phase 2 trial to evaluate the long-term safety and efficacy of travoprost intraocular implant, an extended-release drug delivery system designed to provide uninterrupted sustained intraocular pressure (IOP)-lowering therapy, thereby reducing patient treatment burden and improving adherence with IOP-lowering medication. METHODS: Patients with open-angle glaucoma or ocular hypertension were administered a fast-eluting implant (FE implant, n = 51) and received twice-daily (BID) placebo eye drops, a slow-eluting (SE implant, n = 54) and received BID placebo eye drops, or underwent a sham surgical procedure and received BID timolol 0.5% (n = 49). IOP was measured at baseline, day 1-2, day 10, week 4, week 6, month 3, and every 3 months thereafter through 36 months. Efficacy was evaluated by mean change from 8:00 AM unmedicated baseline IOP through month 36, and the percentage of patients receiving the same or fewer topical IOP-lowering medications as at screening (pre-study). Safety was evaluated by adverse events and ophthalmic parameters. RESULTS: Clinically and statistically relevant IOP-lowering treatment effects were observed through month 36 after a single administration of the travoprost implant compared with BID timolol with mean IOP reductions ranging from 7.6 to 8.8 mmHg for the FE implant group, from 7.3 to 8.0 mmHg for the SE implant group, and from 7.3 to 7.9 for the timolol group at the 8:00 AM timepoint (P < 0.0001 for all treatment groups at all visits). At months 12, 24, and 36, a greater percentage of FE and SE implant patients versus timolol patients were well controlled on the same or fewer topical IOP-lowering medications compared with screening with 63 and 69% for the FE and SE implants groups, respectively, versus 45% for the timolol group at month 36. The safety profile of the implant was favorable; there were no dislodgements, no explantations, no adverse events of conjunctival hyperemia or periorbital fat atrophy, no discontinuations due to study eye adverse events, nor any serious adverse events in the study eye. Comparable changes from baseline in corneal endothelial cell counts were observed in the three treatment groups over the 36 months. CONCLUSION: The travoprost intraocular implant demonstrated robust IOP-lowering and substantially reduced topical IOP-lowering medication burden for up to 36 months following a single administration, while maintaining a favorable safety profile. The travoprost intraocular implant promises to be a meaningful addition to the interventional glaucoma armamentarium by addressing the key shortcomings of topical IOP-lowering medications, including low adherence and topical side effects while controlling IOP for up to 36 months. TRIAL REGISTRY: ClinicalTrials.gov identifier NCT02754596 registered 28 April 2016.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Hipertensão Ocular , Humanos , Travoprost/uso terapêutico , Glaucoma de Ângulo Aberto/tratamento farmacológico , Glaucoma de Ângulo Aberto/cirurgia , Pressão Intraocular , Timolol/efeitos adversos , Anti-Hipertensivos/efeitos adversos , Cloprostenol/efeitos adversos , Hipertensão Ocular/tratamento farmacológico , Glaucoma/tratamento farmacológico , Soluções Oftálmicas/uso terapêutico , Método Duplo-Cego , Resultado do Tratamento
6.
J Glaucoma ; 33(1): 1-7, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-37851966

RESUMO

Selective laser trabeculoplasty (SLT) has been in routine clinical use for over 20 years with millions of patients successfully treated and a low rate of clinically significant complications. The procedure requires the clinician to manually position the laser beam on the trabecular meshwork using a gonioscopy lens and to titrate the SLT laser energy based on the amount of pigmentation in the angle, as well as the observation of small bubbles produced by the laser effect. We propose that SLT energy titration is unnecessary either to achieve intraocular pressure (IOP) reduction or to minimize potential side effects. Ample evidence to support our proposal includes multiple clinical reports demonstrating comparable levels of IOP reduction resulting from different laser energies, a large variety of energy and other laser parameters used in commercially available SLT lasers, and the nature of the laser-induced changes in the trabecular meshwork tissue with respect to energy. Despite these variations in laser parameters, SLT consistently reduces IOP with a low complication rate. We propose that using low fixed energy for all patients will effectively and safely lower patients' IOP while reducing the complexity of the SLT procedure, potentially making SLT accessible to more patients.


Assuntos
Glaucoma de Ângulo Aberto , Terapia a Laser , Trabeculectomia , Humanos , Glaucoma de Ângulo Aberto/cirurgia , Trabeculectomia/métodos , Pressão Intraocular , Malha Trabecular/cirurgia , Terapia a Laser/métodos , Resultado do Tratamento
7.
Vet J ; 300-302: 106041, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37931872

RESUMO

Sex effects on ventilatory and oxygen consumption (V̇O2) measurements during exercise have been identified in humans. This study's aim was to evaluate the hypothesis that there are sex effects on ventilatory and V̇O2 measurements in exercising, untrained yearling Thoroughbreds (Tb). Forty-one Tbs (16 colts, 25 fillies; 19.8 ± 1.4 months old) were recruited. Physiological, ventilatory and exercise data were gathered from horses exercising unridden at high intensity on an all-weather track from a global positioning-heart rate unit and a portable ergospirometry system. Data were analysed with an unpaired Student's t-test and the Benjamini-Hochberg correction for multiple testing (P ≤ 0.05 significant). Mean bodyweight (BW, P = 0.002) and wither height (P = 0.04) were greater for colts than fillies. There were no differences in physiological and exercise data and absolute peak V̇O2 between groups. However, fillies had a higher mass specific peak V̇O2 (P = 0.03) than colts (121.5 ± 21.6 mL/kg.min vs. 111.9 ± 27.4 mL/kg.min). The peak breathing frequency was greater for fillies (P < 0.001) while the peak inspiratory (P < 0.001) and expiratory air flow (P < 0.001), peak expiratory tidal volume (VTE; P < 0.001) and peak minute ventilation (V̇E; P = 0.01) were greater for colts; there were no differences for peak VTE and V̇E when adjusted for BW. Differences in BW explain the differences in mass specific peak V̇O2 between groups. Given their morphological differences, it is likely that lung volumes and airway diameters are smaller for fillies, resulting in greater resistance and lower air flows and volumes. Further research is required to investigate the ventilatory differences and how they may change with maturation and impact performance.


Assuntos
Consumo de Oxigênio , Respiração , Masculino , Animais , Humanos , Cavalos , Feminino , Teste de Esforço/veterinária , Frequência Cardíaca , Tempo (Meteorologia) , Oxigênio
8.
J Ophthalmic Vis Res ; 18(2): 150-156, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37181616

RESUMO

Purpose: To evaluate the effect of phacoemulsification on intraocular pressure (IOP) in eyes with functioning tube shunts. Methods: This was a retrospective chart review of primary open-angle glaucoma (POAG) patients with a functioning tube who underwent phacoemulsification and had ≥24 months of follow-up. The primary end point was defined as surgical failure (IOP > 21 mmHg) at month 24, progression to no light perception (NLP) vision, glaucoma reoperation, or implant removal. Surgical failure defined as IOP >18 and >15 mmHg, changes in visual acuity (VA), IOP, and number of medications were assessed. Results: Twenty-seven eyes of 27 patients with moderate or severe POAG were included. The mean age of the patients was 64.2 ± 10.8 years. The interval between the tube shunt and phacoemulsification was 28.8 ± 25.0 months. At the end of the study, four (14.8%) eyes met the failure criteria; the average time to failure was 9.3 ± 3.8 months. The causes of failure were high IOP in two (50.0%) and glaucoma reoperation in two (50.0%) eyes; however, no eyes progressed to NLP vision. Surgical failure defined as IOP >18 and >15 mmHg showed an increasing failure rate (18.5% and 48.5%, respectively).Themean IOP and medications number remained stable at month 24 compared to baseline (P = 0.131 and P = 0.302, respectively). Initially, VA showed improvement, with the greatest improvement at 6 months (P = 0.001), but at 24 months the improvement was no longer significant (P = 0.430). Conclusion: Phacoemulsification in patients with functioning tubes did not change the mean IOP in most of the patients (86.2%); the number of medications also did not increase.

9.
Eye (Lond) ; 37(17): 3666-3674, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37221362

RESUMO

OBJECTIVE: Halting and reversing glaucoma therapy-related ocular surface disease (GTR-OSD) will improve the success of long-term medical therapy, impacting millions of patients worldwide. METHODS: A single-centre, masked, prospective, placebo-controlled, crossover trial of 41 well-controlled open-angle glaucoma subjects with moderate to severe GTR-OSD on preserved latanoprost and dorzolamide/timolol fixed combination (DTFC) therapy was conducted. Subjects were randomized to preservative-free (PF) tafluprost and DTFC with either placebo or cyclosporine 0.1% drops for 6 months and were then crossed over to the opposite therapy. Oxford score of ocular staining was the primary outcome; osmolarity, matrix-metalloproteinase-9 (MMP-9) testing, tear film break-up time (TFBUT), meibomian gland dysfunction (MGD), punctum evaluation, adverse events and diurnal intraocular pressure (IOP) comprised secondary outcomes. RESULTS: GTR-OSD findings improved with PF therapy. At 6 months the triple PF with placebo group showed improvement compared to baseline in mean Oxford score (mean difference [MD]:-3.76; 95% confidence interval [CI]:-4.74 to -2.77; p < 0.001), osmolarity (MD:-21.93; 95%CI:-27.61 to -16.24 mOsm/l; p < 0.001), punctum stenosis (p = 0.008) and conjunctival hyperaemia (p < 0.001). Similar improvements occurred in the cyclosporine enhanced period, which also provided greater improvement in MMP-9 positivity (24 vs 66%; p < 0.001) and TFBUT (p = 0.022). The cyclosporine group was superior vs placebo in mean Oxford score (MD:-0.78; 95%CI:-1.40 to -0.15); p < 0.001), itchiness and objective adverse events (p = 0.034). Cyclosporine elicited more stinging vs placebo (63 vs 24%; p < 0.001). Both PF regimens reduced mean diurnal IOP more than preserved therapy (14.7 vs 15.9 mmHg; p < 0.001). CONCLUSIONS: Changing from preserved to PF glaucoma medications improves ocular surface health and IOP control. Topical cyclosporine 0.1% further reverses GTR-OSD.


Assuntos
Ciclosporinas , Glaucoma de Ângulo Aberto , Glaucoma , Hipertensão Ocular , Humanos , Glaucoma de Ângulo Aberto/tratamento farmacológico , Metaloproteinase 9 da Matriz/uso terapêutico , Estudos Prospectivos , Anti-Hipertensivos/uso terapêutico , Resultado do Tratamento , Glaucoma/tratamento farmacológico , Timolol/uso terapêutico , Timolol/efeitos adversos , Pressão Intraocular , Conservantes Farmacêuticos/uso terapêutico , Combinação de Medicamentos , Ciclosporinas/uso terapêutico
10.
Am J Ophthalmol ; 252: 17-25, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36868339

RESUMO

PURPOSE: To report 5-year postoperative safety data of iStent inject, including overall stability, endothelial cell density (ECD), and endothelial cell loss (ECL) in patients with mild-to-moderate primary open-angle glaucoma (POAG). DESIGN: 5-year follow-up safety study of the prospective, randomized, single-masked, concurrently controlled, multicenter iStent inject pivotal trial. METHODS: In this 5-year follow-up safety study of the 2-year iStent inject pivotal randomized controlled trial, patients receiving iStent inject placement and phacoemulsification or phacoemulsification alone were studied for the incidence of clinically relevant complications associated with iStent inject placement and stability. Corneal endothelial endpoints were mean change in ECD from screening and proportion of patients with >30% ECL from screening, from analysis of central specular endothelial images by a central image analysis reading center at several time points through 60 months postoperatively. RESULTS: Of the 505 original randomized patients, 227 elected to participate (iStent inject and phacoemulsification group, n = 178; phacoemulsification-alone control group, n = 49). No specific device-related adverse events or complications were reported through month 60. No significant differences were observed in mean ECD, mean percentage change in ECD, or proportion of eyes with >30% ECL between the iStent inject and control groups at any time point; mean percentage decrease in ECD at 60 months was 14.3% ± 13.4% in the iStent inject group and 14.8% ± 10.3% in the control group (P = .8112). The annualized rate of ECD change from 3 to 60 months was neither clinically nor statistically significant between groups. CONCLUSIONS: Implantation of iStent inject during phacoemulsification in patients with mild-to-moderate POAG did not produce any device-related complications or ECD safety concerns compared to phacoemulsification alone through 60 months.


Assuntos
Extração de Catarata , Glaucoma de Ângulo Aberto , Facoemulsificação , Humanos , Glaucoma de Ângulo Aberto/cirurgia , Pressão Intraocular , Estudos Prospectivos , Facoemulsificação/métodos , Endotélio Corneano , Stents
11.
J Glaucoma ; 32(1): 9-18, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36260288

RESUMO

PRCIS: The iStent Infinite Trabecular Micro-Bypass System implanted in patients with open angle glaucoma (OAG) (uncontrolled by prior surgical or medical therapy) was effective in reducing mean diurnal intraocular pressure with a favorable safety profile. PURPOSE: The purpose of this study is to evaluate safety and effectiveness of the iStent infinite Trabecular Micro-Bypass System in patients with OAG uncontrolled by prior surgical or medical therapy. DESIGN: Prospective, multicenter, single-arm, open-label clinical trial. METHODS: Implantation of iStent infinite (3 iStent inject W stents) was performed as a stand-alone surgical procedure in eyes with OAG uncontrolled by prior incisional or cilioablative surgeries or maximum tolerated medical therapy (MTMT). Prospectively declared effectiveness endpoints were proportion of eyes achieving ≥20% mean diurnal intraocular pressure (MDIOP) reduction from baseline at month 12 on the same or fewer intraocular pressure (IOP)-lowering medication classes (responder endpoint) and mean change in MDIOP from baseline at month 12. Safety parameters included visual acuity, slit-lamp and fundus examinations, gonioscopy, perimetry, surgical complications, and adverse events. RESULTS: Seventy-two eyes of 72 patients (mean age 71.9 y) with preoperative mean medicated MDIOP of 23.4±2.8 mm Hg on a mean of 3.1±0.9 IOP-lowering medication classes were enrolled: 61 eyes with failed prior surgery/ies (Failed-Surgery subgroup) and 11 eyes uncontrolled on MTMT (MTMT subgroup). A total of 76.1% of all enrolled patients met the responder endpoint (73.4% Failed-Surgery, 90.9% MTMT), with mean reduction (SE) in MDIOP at month 12 of 5.9(0.6) mm Hg [5.5(0.7) mm Hg Failed-Surgery subgroup, 8.1(0.9) mm Hg MTMT subgroup]. For patients on the same or fewer medication(s) as baseline, 53.0% achieved ≥30% MDIOP reduction without surgical interventions/other events. Safety was favorable, with no explants, infection, or device-related interventions or hypotony. CONCLUSIONS: iStent infinite stand-alone surgery achieved clinically significant IOP reduction and favorable safety in patients with OAG uncontrolled by prior therapy.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Hipotensão Ocular , Humanos , Idoso , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/cirurgia , Glaucoma de Ângulo Aberto/tratamento farmacológico , Pressão Intraocular , Estudos Prospectivos , Malha Trabecular/cirurgia , Stents
12.
J Glaucoma ; 31(8): e49-e68, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35701875

RESUMO

PRCIS: A literature review of selective laser trabeculoplasty (SLT) energy dose-response found no definitive relationship between intraocular pressure (IOP) reduction with respect to total or pulse energy, race, pigmentation, or application pattern. PURPOSE: SLT is a safe and effective treatment for lowering IOP. Although evidence is mounting for the advantage of its use as a first-line treatment for IOP reduction, the SLT procedures in use vary widely. The purpose of this literature review was to investigate whether there were any relationships between SLT energy and efficacy for lowering IOP in the published literature. METHODS: A literature review was undertaken that included studies in which energy levels required for successful SLT treatment were investigated: in general, with respect to angle pigmentation, race or ethnicity, and treatment arc extent. RESULTS: There was no indication that higher (or lower) energy used in the treatment leads to greater (or less) IOP reduction. Similar results were obtained regarding the level of trabecular meshwork pigmentation. Race was not found to be associated with altered dose response in SLT. There were indications that treating the full 360 degrees, as opposed to smaller arcs, could be beneficial for more IOP reduction. IOP reduction from SLT was found to be similar to that provided by topical medications. CONCLUSIONS: The optimal energy level of SLT needed for IOP reduction has not yet been definitively established, with all reported pulse energies resulting in similar IOP reduction. Furthermore, similar lack of conclusive findings exists regarding optimal SLT energy dosage for use in different races and degrees of trabecular meshwork pigmentation. This parameter and each of the abovementioned factors requires further research.


Assuntos
Glaucoma de Ângulo Aberto , Terapia a Laser , Hipotensão Ocular , Trabeculectomia , Glaucoma de Ângulo Aberto/tratamento farmacológico , Glaucoma de Ângulo Aberto/cirurgia , Humanos , Pressão Intraocular , Terapia a Laser/métodos , Lasers , Hipotensão Ocular/cirurgia , Malha Trabecular/cirurgia , Trabeculectomia/métodos , Resultado do Tratamento
13.
Indian J Ophthalmol ; 70(4): 1253-1259, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35326027

RESUMO

Purpose: To determine the outcomes of Ahmed glaucoma valve (AGV) and transscleral diode cyclophotocoagulation (CPC) in neovascular glaucoma (NVG). Methods: This was a single-center retrospective comparative case series involving chart review of consecutive patients who underwent AGV or CPC for treatment of NVG and had ≥6 months of follow-up. Surgical failure at 6 months, defined as an IOP of >21 or <6 mm Hg with hypotony maculopathy after 1 month, progression to no light perception (NLP) vision, glaucoma reoperation, or removal of AGV were the main outcome measures. Results: In total, 121 eyes of 121 patients were included (70 AGV and 51 CPC). Baseline demographics, visual acuity (VA), and intraocular pressure (IOP) were comparable between groups. At 6 months, failure was significantly higher in the CPC group than in the AGV group (43.1% vs. 17.1%, P = 0.020). Both groups had similar IOP and medication number at 6 months, but VA was significantly lower in the CPC group compared to the AGV group (2.4 ± 0.8 vs. 1.9 ± 1.0, P = 0.017). More CPC eyes required reoperation for glaucoma than AGV eyes (11.8% vs. 1.4%, P = 0.041). Multivariate regression analysis identified higher preoperative IOP (P = 0.001) and CPC surgery (P = 0.004) as independent predictors of surgical failure at 6 months. Age, sex, race, NVG etiology, bilaterality of the underlying retinal pathology, perioperative retina treatment, and prior or combined vitrectomy were not significant. Conclusion: AGV and CPC had comparable IOP and medication reduction in NVG eyes at 6 months. CPC was more frequently associated with failure, reoperation for glaucoma, and worse visual outcomes. High preoperative IOP and CPC surgery independently predicted surgical failure.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma Neovascular , Glaucoma , Seguimentos , Glaucoma/cirurgia , Glaucoma Neovascular/diagnóstico , Glaucoma Neovascular/cirurgia , Humanos , Pressão Intraocular , Fotocoagulação a Laser , Estudos Retrospectivos , Resultado do Tratamento
14.
Eur J Ophthalmol ; 32(3): 1538-1546, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34041935

RESUMO

PURPOSE: To determine the efficacy of an educational intervention on patient adoption and attitudes toward selective laser trabeculoplasty (SLT) as first-line treatment for glaucoma. METHODS: This study is a randomized controlled trial. Subjects include 33 patients within 1-year diagnosis of either primary open-angle glaucoma, ocular hypertension, or pseudoexfoliation syndrome. After informed consent, subjects were randomly assigned to a Usual Care or Educational Intervention group. All subjects completed a pre-intervention questionnaire. The Educational Intervention group was shown a slideshow presentation and a 3-min video and given a post-intervention questionnaire. Follow-up examinations were reviewed for 6 months to determine subject completion of SLT, the primary outcome. Secondary outcomes include assessment of attitude toward SLT before and after intervention. RESULTS: Age, gender, and baseline characteristics between the groups did not differ. The Usual Care group had a higher proportion of African Americans (77% vs 31%, p = 0.04). At 6 months following the intervention, 63% of subjects underwent SLT compared to 35% of Usual Care subjects (p = 0.12). Older age was associated with decreased SLT uptake (OR 0.90, 95% CI 0.82-0.99, p = 0.03). Prior to the intervention, there were no differences in attitudes of both groups regarding SLT therapy. Nineteen percent of Educational Intervention subjects changed positively toward SLT (p = 0.08) and 50% scheduled an SLT appointment after intervention (p = 0.005). CONCLUSIONS: A slideshow and video-based educational intervention may positively enhance patient adoption of SLT.Clinical trial registration name, number, URL: Educational Intervention to Adopt SLT as First-Line Glaucoma Treatment, NCT03365778, https://clinicaltrials.gov/ct2/show/NCT03365778.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Terapia a Laser , Trabeculectomia , Glaucoma/cirurgia , Glaucoma de Ângulo Aberto/cirurgia , Humanos , Pressão Intraocular , Lasers , Resultado do Tratamento
15.
Fam Cancer ; 21(2): 181-188, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-33837488

RESUMO

Lynch syndrome is an inherited cancer predisposition syndrome caused by germline defects in any of the mismatch repair (MMR) genes. Diagnosis of carriers makes precision prevention, early detection, and tailored treatment possible. Herein we report a novel founder deletion of 18,758 bp, mediated by Alu repeats on both sides, detected in Ethiopian Jews. The deletion, which encompasses exon 9-10 of the MSH2 coding sequence, is associated mainly with early-onset MSH2/MSH6-deficient colorectal cancer (CRC) and liposarcoma. Testing of 35 members of 5 seemingly unrelated families of Ethiopian origin yielded 10/21 (48%) carriers, of whom 9 had CRC. Age at first tumor diagnosis ranged from 16 to 89 years. Carriers from the oldest generations were diagnosed after age 45 years (mean 57), and carriers from the younger generation were diagnosed before age 45 years (mean 30). Awareness of this founder deletion is important to improve patient diagnosis, institute surveillance from an early age, and refer patients for genetic counseling addressing the risk of bi-allelic constitutional MMR deficiency syndrome.


Assuntos
Neoplasias Colorretais Hereditárias sem Polipose , Neoplasias Colorretais , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Colorretais/genética , Neoplasias Colorretais Hereditárias sem Polipose/diagnóstico , Reparo de Erro de Pareamento de DNA/genética , Etiópia , Mutação em Linhagem Germinativa , Humanos , Judeus/genética , Pessoa de Meia-Idade , Proteína 2 Homóloga a MutS/genética , Adulto Jovem
17.
Surv Ophthalmol ; 67(4): 1062-1080, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34890600

RESUMO

Glaucoma, a progressive optic neuropathy characterized by retinal ganglion cell degeneration and visual field loss, is the leading cause of irreversible blindness worldwide. Intraocular pressure (IOP) is presently the only modifiable risk factor demonstrated to slow or halt disease progression; however, glaucomatous damage persists in almost 50% of patients despite significant IOP reduction. Many studies have investigated the non-IOP-related risk factors that contribute to glaucoma progression as well as interventions that can prevent or delay glaucomatous neurodegeneration and preserve vision throughout life, independently of IOP. A vast number of experimental studies have reported effective neuroprotection in glaucoma, and clinical studies are ongoing attempting to provide strong evidence of effectiveness of these interventions. We look into the current understanding of the pathophysiology of glaucoma and explore the recent advances in non-IOP related strategies for neuroprotection and neuroregeneration in glaucoma.


Assuntos
Glaucoma , Pressão Intraocular , Humanos , Células Ganglionares da Retina , Tonometria Ocular , Testes de Campo Visual
18.
J Curr Glaucoma Pract ; 15(2): 70-77, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34720496

RESUMO

IMPORTANCE: Few studies have analyzed associations between sociodemographic factors and neovascular glaucoma (NVG) outcomes. AIM AND BACKGROUND: To determine the potential impact of sociodemographic and economic factors on the NVG tube shunt surgery outcomes. DESIGN: Retrospective, single-center, comparative case series. PARTICIPANTS: Consecutive patients who underwent tube shunt surgery for NVG and had ≥6 months of follow-up. MATERIALS AND METHODS: Regional average adjusted gross income (AGI) was determined by cross-referencing self-reported residential zip codes with average AGI per zip code supplied by the Internal Revenue Service. Two groups were created: (1) lower-income: individuals from neighborhoods with the lowest 10% of AGI (near the United States poverty line), (2) higher-income: the remaining 90% of individuals. MAIN OUTCOME MEASURES: Visual acuity (VA), intraocular pressure (IOP), and glaucoma medication number at 6 months and the most recent visit. RESULTS: The mean annual AGI in the higher-income group (130 patients) was $69,596 ± 39,700 and the lower-income group (16 patients) was $27,487 ± 1,600 (p < 0.001). Age, sex, distance to the clinic, language, and all baseline clinical variables (including VA and IOP) were comparable between groups. Lower-income was associated with non-white race (81.3 vs 52.3%; p = 0.024). At month 6, VA in the lower-income group [median: HM (20/70-NLP)] was worse than the higher-income group [median: CF (20/25-NLP)] (log MAR VA: 2.32 ± 0.8 vs 1.77 ± 1.1; p = 0.02); these trends persisted through the most recent visit (p = 0.043). Follow-up IOP and medications were similar between groups. CONCLUSIONS AND RELEVANCE: Lower-income may be associated with worse VA outcomes following NVG tube shunt surgery. HOW TO CITE THIS ARTICLE: Shalaby WS, Arbabi A, Myers JS, et al. Sociodemographic and Economic Factors in Outcomes of Tube Shunts for Neovascular Glaucoma. J Curr Glaucoma Pract 2021;15(2):70-77.

19.
Clin Ophthalmol ; 15: 3231-3240, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34376967

RESUMO

PURPOSE: To examine effectiveness outcomes stratified by preoperative disease burden in the pivotal trial of iStent inject ® with cataract surgery (INJ) vs cataract surgery alone (CS). MATERIALS AND METHODS: Prospective, 3:1 randomized, single-masked, concurrently-controlled, multicenter trial enrolling 505 subjects with cataract and mild-to-moderate primary open-angle glaucoma who underwent iStent inject implantation with phacoemulsification or phacoemulsification alone, and were followed for 2 years including annual medication washouts. Post hoc stratification was completed for baseline mean diurnal intraocular pressure (BL DIOP; Low-DIOP <25mmHg, Mid-DIOP ≥25 to <30 mmHg, High-DIOP ≥30mmHg) and preoperative medication burden (Low-Med 1 medication, Mid-Med 2 medications, High-Med ≥3 medications). RESULTS: The 24-month primary and secondary effectiveness endpoints were met, with significant treatment-over-control differences in percent of eyes achieving ≥20% unmedicated DIOP reduction and in unmedicated DIOP reduction, respectively. In subgroup analyses, the proportions of INJ eyes achieving the primary endpoint remained steady across all BL DIOP (75.4%, 77.1%, 74.4% in Low/Mid/High-DIOP strata, respectively) and preoperative medication levels (76.8%, 70.8%, 79.7% in Low/Mid/High-Med strata, respectively); meanwhile, the proportions of CS eyes diminished with higher BL DIOP (64.5%, 63.6%, 33.3%, respectively) and more medications (69.0%, 63.3%, 29.4%, respectively). Regarding secondary effectiveness, postoperative DIOP reduction increased with higher BL DIOP in INJ eyes (6.2mmHg, 7.8mmHg, 9.8mmHg, respectively) but plateaued in CS eyes (5.2mmHg, 5.8mmHg, 5.4mmHg, respectively). INJ eyes also had consistent DIOP reduction regardless of preoperative medication burden (6.8mmHg, 6.7mmHg, 7.8mmHg, respectively), while DIOP reduction diminished with more medications in CS eyes (6.1mmHg, 5.0mmHg, 3.3mmHg, respectively). Safety was favorable, comparable to phacoemulsification alone. CONCLUSION: Significant IOP reductions occurred across all levels of BL DIOP and preoperative medication burden in iStent inject eyes. DIOP reductions increased with higher BL DIOP and remained stable across all levels of preoperative medication burden, suggesting the device's potential utility in more medically challenging cases.

20.
Comput Electron Agric ; 187: None, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34381288

RESUMO

Collection of accurate and representative data from agricultural fields is required for efficient crop management. Since growers have limited available resources, there is a need for advanced methods to select representative points within a field in order to best satisfy sampling or sensing objectives. The main purpose of this work was to develop a data-driven method for selecting locations across an agricultural field given observations of some covariates at every point in the field. These chosen locations should be representative of the distribution of the covariates in the entire population and represent the spatial variability in the field. They can then be used to sample an unknown target feature whose sampling is expensive and cannot be realistically done at the population scale. An algorithm for determining these optimal sampling locations, namely the multifunctional matching (MFM) criterion, was based on matching of moments (functionals) between sample and population. The selected functionals in this study were standard deviation, mean, and Kendall's tau. An additional algorithm defined the minimal number of observations that could represent the population according to a desired level of accuracy. The MFM was applied to datasets from two agricultural plots: a vineyard and a peach orchard. The data from the plots included measured values of slope, topographic wetness index, normalized difference vegetation index, and apparent soil electrical conductivity. The MFM algorithm selected the number of sampling points according to a representation accuracy of 90% and determined the optimal location of these points. The algorithm was validated against values of vine or tree water status measured as crop water stress index (CWSI). Algorithm performance was then compared to two other sampling methods: the conditioned Latin hypercube sampling (cLHS) model and a uniform random sample with spatial constraints. Comparison among sampling methods was based on measures of similarity between the target variable population distribution and the distribution of the selected sample. MFM represented CWSI distribution better than the cLHS and the uniform random sampling, and the selected locations showed smaller deviations from the mean and standard deviation of the entire population. The MFM functioned better in the vineyard, where spatial variability was larger than in the orchard. In both plots, the spatial pattern of the selected samples captured the spatial variability of CWSI. MFM can be adjusted and applied using other moments/functionals and may be adopted by other disciplines, particularly in cases where small sample sizes are desired.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...