Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Conserv Dent ; 26(1): 73-78, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36908731

RESUMO

Aim: The aim of this study was to compare the cytotoxic effect of calcium silicate-based Bio-C, CeraSeal, and mineral trioxide aggregate (MTA)-based (MTA-Fillapex) sealers to a widely used resin-based sealer (AH Plus) using 3-(4, 5 dimethythiazol-2yl)-2, 5-diphenyltetrazolium bromide (MTT) assay and microscopic examination. Materials and Methods: A total of (n = 36) samples divided into four groups with three sealer samples per time period of 0 h, 24 h, and 7 days after mixing were extracted in cell culture medium using Dulbecco's Modified Eagle's Medium. The cytotoxicity of these sealers was evaluated using an MTT assay on L929 mouse fibroblasts, and changes in the cell morphology were observed under an inverted phase-contrast microscope (×20). The values obtained were analyzed statistically using one-way ANOVA, Tukey's post hoc, and Bonferroni's test. Results: Bio-C and CeraSeal showed a reduction in cytotoxicity from severe at 0 h to no cytotoxicity at 24 h and 7 day time period. AH Plus showed severe cytotoxicity at all time periods. MTA-Fillapex showed severe cytotoxicity at 0 h which decreased to moderate at 24 h and 7 days. The differences between groups were statistically significant (P < 0.05). Conclusions: The sealers with resin constituents (AH Plus and MTA-Fillapex) showed severe-to-moderate cytotoxicity at different time periods, whereas calcium silicate-based sealers (Bio-C and CeraSeal) were relatively biocompatible as their cytotoxicity decreased significantly from severe initially to noncytotoxic with time.

2.
J Pharm Bioallied Sci ; 13(Suppl 1): S857-S860, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34447215

RESUMO

BACKGROUND: Inadequate obturation techniques of the root canal system have been found to be the most frequent reason of failure post root canal treatment. An ideal endodontic sealer should fulfill all ideal requisites. The present study aimed to compare apical sealing ability between bioceramic (BC) sealer, GuttaFlow, and AH Plus. METHODOLOGY: One hundred and twenty-five curved roots of maxillary and mandibular third molar teeth with fully formed apex were collected for this study. The root canals were cleaned and shaped using a standard single-cone preparation to file at the established working length and divided into five groups of 25 each. Dye leakage was carried out. Group A: with GP, using EndoSequence BC sealer with conventional with 4% gutta-percha (Brasseler USA, Savannah, Georgia, USA); Group B: with ceramic coated with 4% gutta-percha (Brasseler USA, Savannah, Georgia, USA); Group C: with GP, using AH Plus sealer (Dentsply, De-Trey Konstanz, Germany) with 4% gutta-percha; Group D: with GuttaFlow bioseal (Roeko-Coltène/Whaledent, Langenau, Germany) with 4% Gutta-percha; and Group E is a negative control group. Statistical analysis was done using the Statistical Package for the Social Sciences software and Student's unpaired t-test. RESULTS: The group AH Plus showed more leakage values than the GuttaFlow group and of two groups of BC sealer and negative control. Student's unpaired t-test disclosed no significant difference (P < 0.05) between the groups. CONCLUSION: None of the sealers used in the study could completely seal the apical foramen to have a fluid-tight seal.

3.
J Contemp Dent Pract ; 22(5): 511-516, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34318769

RESUMO

AIM AND OBJECTIVE: This study was carried out to compare the effectiveness of biodentine, calcium hydroxide, and 2% chlorhexidine gluconate used along with resin-modified glass ionomer cement (RMGIC) as indirect pulp capping (IPC) materials in young permanent molars. MATERIALS AND METHODS: In this study, 54 patients were selected. Among these patients, 72 young permanent molars were selected randomly in which IPC was required. These teeth were randomly categorized into three different groups and each group consisted of 24 teeth. The first group was group A consisting of teeth treated with biodentine, the second group was group B consisting of teeth treated with 2% chlorhexidine gluconate being followed by RMGIC, while the third was group C consisting of teeth treated with calcium hydroxide. All cases were subjected to follow-up for clinical and radiographic evaluation at 4, 8, and 16 months. The data were recorded and analyzed statistically by utilizing the Chi-square test. RESULTS: After 16 months, 95.83% of cases in group A consisting of teeth treated with biodentine showed successful results both clinically and radiographically. While 87.5% of cases in group B consisting of teeth treated with 2% chlorhexidine gluconate being followed by RMGIC showed successful results. And finally, 91.66% of cases in group C consisting of teeth treated with calcium hydroxide showed successful results. CONCLUSION: Biodentine can be efficiently used as an IPC agent in young permanent molars although all three materials were effective in IPC with a nonsignificant difference statistically. This study highlights the success of IPC in young permanent molars and the choice of better IPC material can be biodentine. CLINICAL SIGNIFICANCE: Indirect pulp capping is one of the procedures in which preservation of carious affected dentin nearest to the pulp is carried out to protect the pulp. Several new IPC agents like biodentine have been introduced. Hence, it is necessary to evaluate their effectiveness. How to cite this article: Kaul S, Kumar A, Jasrotia A, et al. Comparative Analysis of Biodentine, Calcium Hydroxide, and 2% Chlorhexidine with Resin-modified Glass Ionomer Cement as Indirect Pulp Capping Materials in Young Permanent Molars. J Contemp Dent Pract 2021;22(5):511-516.


Assuntos
Capeamento da Polpa Dentária , Agentes de Capeamento da Polpa Dentária e Pulpectomia , Compostos de Cálcio , Hidróxido de Cálcio , Clorexidina , Cimentos de Ionômeros de Vidro , Humanos , Dente Molar , Silicatos
4.
J Contemp Dent Pract ; 21(11): 1233-1237, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-33850068

RESUMO

AIM AND OBJECTIVE: The present study aimed to assess the formation of microcracks in root dentin post-instrumentation with nickel-titanium (NiTi) hand and rotary file system. MATERIALS AND METHODS: Totally, 80 freshly extracted mandibular premolar teeth with single roots were chosen for this study. Access opening was performed and #10 K-file was used to attain patency of canal. All specimens were divided into four groups (each group having 20 specimens), i.e., Group I: Unprepared, Group II: NiTi hand K-files, Group III: Self-adjusting file, and Group IV: XP-Shaper single file. Complete irrigation of all the canals was performed after instrumentation. All roots were cut horizontally at three levels [apical third (3 mm), middle third (6 mm), and cervical third (9 mm)] from the apex with diamond disc. A stereomicroscope was used to view the sections under 20× magnification. RESULTS: Self-adjusting file showed least number of defects with a percentage of 75% followed by XP-Shaper and NiTi hand K-files with a values of 65 and 60%, respectively. Use of hand K-files resulted in greater number of incomplete cracks (30%) and use of XP-Shaper demonstrated greater number of craze lines (15%). A statistically significant difference was found between the experimental groups in the formation of dentinal defects of root at apical third (3 mm) (p < 0.031) and middle third (6 mm) (p < 0.001), whereas the sections at cervical third (9 mm) did not show any statistically significant difference (p > 0.312). CONCLUSION: The present study concluded that the self-adjusting file system gives promising better results in cleaning ability with minimal incidence of radicular dentin microcracks than XP-Shaper and NiTi hand K-files system. CLINICAL SIGNIFICANCE: The root dentin may unavoidably get damaged during instrumentation resulting in the formation of dentinal cracks and tiny complicated fractures, thus leading to endodontic failures. Various factors cause dentinal cracks, but the flexibility of file due to heat treatment, kinematics of the file, and the basic architecture of the file are the most significant ones. Self-adjusting file system represented satisfactory results with minimal microcracks defects.


Assuntos
Níquel , Preparo de Canal Radicular , Cavidade Pulpar , Dentina , Titânio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...