Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anesth Essays Res ; 13(2): 308-312, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31198251

RESUMO

BACKGROUND: The most commonly used devices for direct visualization of the larynx and tracheal intubation are Macintosh and McCoy laryngoscopes. C-MAC video laryngoscope, based on the principles of indirect laryngoscopy, has been introduced into clinical practice in recent years. Video laryngoscope may be useful in difficult tracheal intubation situations. AIM: We aimed at comparing the McCoy and C-MAC video laryngoscope with conventional Macintosh laryngoscope for hemodynamic responses of orotracheal intubation among adults receiving general anesthesia for elective surgeries. SETTINGS AND DESIGN: This was a hospital-based randomized, double-blind, comparison, done between June 2015 and October 2016 after permission of institutional ethical committee. MATERIALS AND METHODS: One hundred and fifty patients with normal airways undergoing elective general anesthesia were randomly allocated to undergo intubation using either Macintosh (Group A), McCoy (Group B), or C-MAC video laryngoscope (Group C). Hemodynamic changes associated with intubation were recorded immediately before and after laryngoscopy and intubation, every minute for 5 min and at 10 min after intubation by an independent observer. The time taken to perform endotracheal intubation and Cormack and Lehane score were also noted in all three groups. STATISTICAL ANALYSIS: Data were compiled, and statistical analysis was performed using SPSS 17.0 version. RESULTS: Hemodynamic response after intubation was least in Group B (McCoy) as compared to Group A (Macintosh) and Group C (C-Mac) (P = 0.001). Ninety-two percentage patients were in Cormack and Lehane score Class I in Group C in comparison to 52% in Group A and 48% in Group B (P = 0.000). Time for intubation taken in Group A, Group B, and Group C was 15.53 ± 1.53 min, 18.65 ± 0.44 min, and 22.82 ± 1.323 min, respectively (P = 0.000). CONCLUSION: The McCoy laryngoscope provided better attenuation of hemodynamic responses to laryngoscopy and intubation than the Macintosh and C-Mac video laryngoscope whereas more appearance of Cormack and Lehane score Class I was seen with the C-MAC video laryngoscope. Furthermore, the time taken to perform endotracheal intubation was the longest with the C-MAC video laryngoscope.

2.
Food Nutr Bull ; 23(1): 57-64, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11975370

RESUMO

A nutritionally controlled study was conducted on two groups of 15 female college students aged 16 to 20 years, selected from Punjab Agricultural University, Ludhiana, Punjab, India. The girls were either anemic (hemoglobin 7.7 g/dl) but energy adequate (AEA), or anemic (hemoglobin 7.4 g/dl) and energy deficient (AED). The AEA group was given iron supplementation (60 mg iron/day) for 6 to 9 months along with 100 mg of ascorbic acid, and the AED group was given iron as well as energy supplementation for 3 months. There was a significant (p < .01) increase in weight, body mass index, mid-upper-arm circumference, and body fat in the AED group after iron-energy supplementation. Hemoglobin, serum iron, transferrin saturation, total iron-binding capacity, and unsaturated iron-binding capacity were below normal in both groups; however, after iron and iron-energy supplementation, there was a significant (p < .01) increase, and these indices were in the normal range. There was a significant (p < .01) increase in exercise time and maximum work load tolerance after iron and iron-energy supplementation. Combined energy and iron deficiency had a greater adverse effect on physical work capacity than energy or iron deficiency alone.


Assuntos
Anemia/tratamento farmacológico , Suplementos Nutricionais , Ingestão de Energia/fisiologia , Ferro/administração & dosagem , Esforço Físico/fisiologia , Adolescente , Adulto , Antropometria , Inquéritos sobre Dietas , Teste de Esforço , Feminino , Hemoglobinas/análise , Humanos , Índia , Estudantes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...