Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
Sci Rep ; 14(1): 15948, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38987540

RESUMO

In empirical art research, understanding how viewers judge visual artworks as beautiful is often explored through the study of attributes-specific inherent characteristics or artwork features such as color, complexity, and emotional expressiveness. These attributes form the basis for subjective evaluations, including the judgment of beauty. Building on this conceptual framework, our study examines the beauty judgments of 54 Western artworks made by native Japanese and German speakers, utilizing an extreme randomized trees model-a data-driven machine learning approach-to investigate cross-cultural differences in evaluation behavior. Our analysis of 17 attributes revealed that visual harmony, color variety, valence, and complexity significantly influenced beauty judgments across both cultural cohorts. Notably, preferences for complexity diverged significantly: while the native Japanese speakers found simpler artworks as more beautiful, the native German speakers evaluated more complex artworks as more beautiful. Further cultural distinctions were observed: for the native German speakers, emotional expressiveness was a significant factor, whereas for the native Japanese speakers, attributes such as brushwork, color world, and saturation were more impactful. Our findings illuminate the nuanced role that cultural context plays in shaping aesthetic judgments and demonstrate the utility of machine learning in unravelling these complex dynamics. This research not only advances our understanding of how beauty is judged in visual art-considering self-evaluated attributes-across different cultures but also underscores the potential of machine learning to enhance our comprehension of the aesthetic evaluation of visual artworks.


Assuntos
Arte , Beleza , Comparação Transcultural , Julgamento , Aprendizado de Máquina , Humanos , Feminino , Alemanha , Masculino , Japão , Adulto , Adulto Jovem , Estética/psicologia , Emoções , População do Leste Asiático
2.
Front Psychol ; 15: 1356237, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38807962

RESUMO

Various objects and artifacts incorporate representations of faces, encompassing artworks like portraits, as well as ethnographic or industrial artifacts such as masks or humanoid robots. These representations exhibit diverse degrees of human-likeness, serving different functions and objectives. Despite these variations, they share common features, particularly facial attributes that serve as building blocks for facial expressions-an effective means of communicating emotions. To provide a unified conceptualization for this broad spectrum of face representations, we propose the term "facial icons" drawing upon Peirce's semiotic concepts. Additionally, based on these semiotic principles, we posit that facial icons function as indexes of emotions and intentions, and introduce a significant anthropological theory aligning with our proposition. Subsequently, we support our assertions by examining processes related to face and facial expression perception, as well as sensorimotor simulation processes involved in discerning others' mental states, including emotions. Our argumentation integrates cognitive and experimental evidence, reinforcing the pivotal role of facial icons in conveying mental states.

3.
Behav Res Methods ; 56(3): 2657-2674, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37162649

RESUMO

In this paper, we introduce an R package that performs automated photo editing effects. Specifically, it is an R implementation of an image-processing algorithm proposed by Boyadzhiev et al. (2015). The software allows the user to manipulate the appearance of objects in photographs, such as emphasizing facial blemishes and wrinkles, smoothing the skin, or enhancing the gloss of fruit. It provides a reproducible method to quantitatively control specific surface properties of objects (e.g., gloss and roughness), which is useful for researchers interested in topics related to material perception, from basic mechanisms of perception to the aesthetic evaluation of faces and objects. We describe the functionality, usage, and algorithm of the method, report on the findings of a behavioral evaluation experiment, and discuss its usefulness and limitations for psychological research. The package can be installed via CRAN, and documentation and source code are available at https://github.com/tsuda16k/materialmodifier .


Assuntos
Algoritmos , Software , Humanos , Percepção
4.
Sci Rep ; 13(1): 19797, 2023 11 13.
Artigo em Inglês | MEDLINE | ID: mdl-37957245

RESUMO

Numerous studies discuss the features that constitute facial attractiveness. In recent years, computational research has received attention because it can examine facial features without relying on prior research hypotheses. This approach uses many face stimuli and models the relationship between physical facial features and attractiveness using methods such as geometric morphometrics and deep learning. However, studies using each method have been conducted independently and have technical and data-related limitations. It is also difficult to identify the factors of actual attractiveness perception using only computational methods. In this study, we examined morphometric features important for attractiveness perception through geometric morphometrics and impression evaluation. Furthermore, we used deep learning to analyze important facial features comprehensively. The results showed that eye-related areas are essential in determining attractiveness and that different racial groups contribute differently to the impact of shape and skin information on attractiveness. The approach used in this study will contribute toward understanding facial attractiveness features that are universal and diverse, extending psychological findings and engineering applications.


Assuntos
Aprendizado Profundo , Face , Beleza , Atenção , Exame Físico
5.
Iperception ; 14(5): 20416695231209846, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38022746

RESUMO

Advances in artificial intelligence (AI) have significantly improved the abilities of machines. Human-unique abilities, such as art creation, are now being challenged by AI. Recent studies have investigated and compared people's attitudes toward human-made and AI-generated artworks. These results suggest that a negative bias may exist toward the latter. However, none of these previous studies has examined the extent of this bias. In this study, we investigate whether a bias against AI art can be found at an implicit level. Viewers' attitudes toward AI art were assessed using eye-tracking measures and subjective aesthetic evaluations. Visual attention and aesthetic judgments were compared between artworks categorized as human-made and AI-made. The results showed that although it was difficult for individuals to identify AI-generated artwork, they exhibited an implicit prejudice against AI art. Participants looked longer at paintings that they thought were made by humans. No significant effect of categorization of paintings was found in subjective evaluations. These findings suggest that although human and AI art may be perceived as having similar aesthetic values, an implicit negative bias toward AI art exists. Although AI can now perform creative tasks, artistic creativity is still considered a human prerogative.

6.
J Clin Transl Res ; 9(1): 33-36, 2023 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-36687296

RESUMO

Background and Aim: A 75-year-old man who had eaten half a head of chopped raw cabbage (approximately 600 g) daily was suffering from the left lower pain, abdominal fullness, and constipation. He was diagnosed with colonic ileus and obstructive colitis due to a fecal impaction in the sigmoid-descending junction. During colonoscopy, a tapered catheter was repeatedly inserted into the impacted feces to inject a bowel-cleansing agent. Finally, the feces were broken to be fragmented enough to path the endoscope through. After the procedure, his symptoms were immediately relieved. Relevance for Patients: Excessive dietary fiber intake can induce fecal ileus. Endoscopic treatment with intra-fecal injection of a bowel-cleansing agent is useful and worth attempting for disimpaction of feces.

7.
Biomedicines ; 10(6)2022 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-35740415

RESUMO

Optimal regimens using recent radiotherapy (RT) equipment for bleeding gastric cancer (GC) have not been fully investigated yet. We retrospectively reviewed the clinical data of 20 patients who received RT for bleeding GC in our institution between 2016 and 2021. Three-dimensional conformal RT was performed. The effectiveness of RT was evaluated by the mean serum hemoglobin (Hb) level and the number of transfused red blood cell (RBC) units 1 month before and after RT. The median first radiation dose was a BED of 39.9 Gy. The treatment success rate was 95% and the rebleeding rate was 10.5%. There was a significant increase in the mean Hb level (8.0 ± 1.1 vs. 9.8 ± 1.3 g/dL, p = 0.01), and a significant decrease in the mean number of transfused RBC units (6.8 ± 3.3 vs. 0.6 ± 1.5 units, p < 0.01). Severe toxicity was observed in two patients (anorexia [n = 1] and gastrointestinal [GI] perforation [n = 1]). Reirradiation was attempted in three patients (for hemostasis [n = 2] and for mass reduction [n = 1]). The retreatment success rate for rebleeding was 100%. GI perforation occurred in two patients who had received hemostatic reirradiation. Palliative RT for bleeding GC using recent technology had excellent efficacy. However, it may be associated with a risk of GI perforation.

8.
Intern Med ; 60(21): 3421-3426, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34719626

RESUMO

A 70-year-old man was diagnosed with coronavirus disease 2019 (COVID-19) pneumonia. Twenty-six days after admission, he experienced hematemesis despite improvement in his respiratory symptoms. Contrast-enhanced computed tomography revealed edematous stomach wall thickening with neither ischemic findings in the gastric wall nor obstruction of the gastric artery. Emergent esophagogastroduodenoscopy showed diffuse dark-red mucosa accompanied by multiple easy-bleeding, irregularly shaped ulcers throughout almost the whole stomach without active bleeding or visible vessels. The clinical course, including the endoscopic findings, progressed favorably with conservative treatment. COVID-19 pneumonia can present with acute gastric mucosal lesion, which may be induced by microvascular thrombosis due to COVID-19-related coagulopathy.


Assuntos
COVID-19 , Idoso , Endoscopia do Sistema Digestório , Hematemese/diagnóstico , Hematemese/etiologia , Humanos , Masculino , SARS-CoV-2 , Estômago
9.
Cureus ; 13(9): e18407, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34733600

RESUMO

We experienced a case of gastric cancer with multiple liver metastases characterized by frequent hypoglycemic attacks. Hypoglycemia was observed on admission. We suspected that the cause of this hypoglycemia was non-islet cell tumor hypoglycemia (NICTH). Staining of the tissue with an insulin-like growth factor (IGF)-II antibody revealed that IGF-II was present in the tumor cells. This finding suggested that the tumor was producing IGF-II, which leads to NICTH. After starting parenteral nutrition, the patient emerged from the hypoglycemic coma. He remained out of the coma until he died of liver failure.

10.
J Clin Transl Res ; 7(5): 621-624, 2021 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-34778591

RESUMO

BACKGROUND AND AIM: A 93-year-old woman who was bedridden with severe dementia was referred to our department with a 3-day history of repeated vomiting after meals. Computed tomography revealed significant dilatation of the duodenum up to the level of the third portion, which was compressed by a large, low-density mass. Upper gastrointestinal endoscopy showed narrowing of the third portion of the duodenum with edematous mucosa covered with multiple white spots, where the endoscope was able to pass through with mild resistance. B-cell lymphoma was histopathologically suspected from biopsy specimens of the mucosa. We performed gastrojejunostomy through the magnetic compression anastomosis (MCA) technique. We prepared two neodymium magnets: Flat plate shaped (15 × 3 mm) with a small hole 3 mm in diameter; a nylon thread was passed through each hole. We then confirmed the absence of no non-target tissue, including large vessels and intestine adjacent to the anastomosis where the magnets were to be placed using endoscopic ultrasonography (EUS) from the stomach. EUS-guided marking using biopsy forceps by biting the mucosa and placing a hemoclip was performed at the anastomosis site in the stomach. The magnet was pushed and delivered to the duodeno-jejuno junction, and another magnet was delivered to the marking point in the stomach. The magnets were attracted toward each other transmurally. The magnets fell into the colon by 11 days after starting the compression, and the completion of gastrojejunostomy was confirmed. RELEVANCE FOR PATIENTS: Endoscopic gastrojejunostomy using MCA is useful as a minimally invasive alternative treatment for duodenal obstruction. EUS for the pre-operative local assessment and EUS-guided marking can ensure the safety of the MCA procedure.

11.
Neuroreport ; 32(10): 858-863, 2021 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-34029292

RESUMO

People require multimodal emotional interactions to live in a social environment. Several studies using dynamic facial expressions and emotional voices have reported that multimodal emotional incongruency evokes an early sensory component of event-related potentials (ERPs), while others have found a late cognitive component. The integration mechanism of two different results remains unclear. We speculate that it is semantic analysis in a multimodal integration framework that evokes the late ERP component. An electrophysiological experiment was conducted using emotionally congruent or incongruent dynamic faces and natural voices to promote semantic analysis. To investigate the top-down modulation of the ERP component, attention was manipulated via two tasks that directed participants to attend to facial versus vocal expressions. Our results revealed interactions between facial and vocal emotional expressions, manifested as modulations of the auditory N400 ERP amplitudes but not N1 and P2 amplitudes, for incongruent emotional face-voice combinations only in the face-attentive task. A late occipital positive potential amplitude emerged only during the voice-attentive task. Overall, these findings support the idea that semantic analysis is a key factor in evoking the late cognitive component. The task effect for these ERPs suggests that top-down attention alters not only the amplitude of ERP but also the ERP component per se. Our results implicate a principle of emotional face-voice processing in the brain that may underlie complex audiovisual interactions in everyday communication.


Assuntos
Emoções/fisiologia , Potenciais Evocados/fisiologia , Expressão Facial , Reconhecimento Facial/fisiologia , Lobo Occipital/fisiologia , Reconhecimento de Voz/fisiologia , Estimulação Acústica/métodos , Adolescente , Adulto , Eletroencefalografia/métodos , Feminino , Humanos , Masculino , Estimulação Luminosa/métodos , Desempenho Psicomotor/fisiologia , Distribuição Aleatória , Gravação em Vídeo/métodos , Adulto Jovem
12.
Nihon Shokakibyo Gakkai Zasshi ; 118(1): 78-85, 2021.
Artigo em Japonês | MEDLINE | ID: mdl-33431753

RESUMO

A woman in her 70s with systemic sclerosis experienced dyspnea, and consequently, she was diagnosed with an esophago-pleural fistula, which was caused by a perforated esophageal ulcer. We administered conservative treatments including continuous pleural drainage and total parenteral nutrition. The fistula was closed but recurred, at which point we attempted to close the fistula by filling and shielding using polyglycolic acid (PGA) sheets and fibrin glue (FG). We were able to safely and smoothly fill and shield the fistula using the PGA sheets with a guidewire. We show that endoscopic closure of an esophago-pleural fistula using this technique is an effective, low-invasive treatment for gastrointestinal perforation and refractory fistulas.


Assuntos
Fístula , Escleroderma Sistêmico , Feminino , Adesivo Tecidual de Fibrina/uso terapêutico , Humanos , Ácido Poliglicólico , Complicações Pós-Operatórias , Escleroderma Sistêmico/complicações , Úlcera
14.
Heliyon ; 6(10): e05148, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33072915

RESUMO

Facial appearance has essential consequences in various social interactions. Previous studies have shown that although people can perceive a variety of impressions from a face, these impressions may form from a relatively small number of core dimensions in the psychological impression space (e.g., valence and dominance). However, few studies have thus far examined which facial shape features contribute to perceptions of the core trait impression dimensions for Asian female faces. This study aimed to identify the commonalities between various facial impressions of Japanese female faces and determine the facial shape components associated with such impressions by applying geometric morphometric (GMM) analysis. In Experiment 1 (Modeling study), Japanese female faces were evaluated in terms of 18 trait adjectives that are frequently used to describe facial appearance in daily life. We found that Japanese female facial appearance is indeed evaluated mainly on the valence and dominance dimensions. In Experiment 2 (Validation study), we confirmed that all the trait impressions were quantitatively manipulated by transforming the facial shape features associated with valence and dominance. Our results provide evidence that various facial impressions derived from these two underlying dimensions can be quantitatively manipulated by transforming facial shape using the GMM techniques.

15.
Gastroenterology Res ; 13(3): 96-100, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32655725

RESUMO

BACKGROUND: This retrospective study aimed to investigate the suitable indications, methodology and long-term effect of the closure of gastrointestinal (GI) fistulas using polyglycolic acid (PGA) sheets and fibrin glue (FG) and to evaluate the usefulness of a delivery technique using a guidewire. METHODS: It involved 10 applications in six patients (median age 73 (range 53 - 78) years old, three men) with GI fistulas. A guidewire was introduced endoscopically or percutaneously into the fistula beyond the opposite orifice of the fistula with radiologic control. A tapered catheter was inserted over the guidewire, and the fistula was cleaned with an adequate quantity of saline. Subsequently, a small piece of PGA sheet was skewered onto the guidewire at the center and then pushed using the tapered catheter over the guidewire and delivered into the fistula. In cases of endoscopic procedure, the mucosa around the fistula was ablated, and the orifice of the fistula along with the surrounding mucosa was shielded with a piece of PGA sheet fixed with hemoclips and FG. RESULTS: Technical success of fistula closure was achieved in all applications, and no complications were observed after the procedure. The long-term occlusion of the fistula was ultimately achieved in four of six patients at 202 - 654 days (median duration, 244 days) after the last procedure with one or two applications. CONCLUSIONS: The closure of GI fistulas using PGA sheets and FG demonstrated long-term efficacy for upper GI fistula of a certain length, and the filling technique using a guidewire ensured a safe smooth procedure.

16.
Intern Med ; 59(11): 1401-1405, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32475907

RESUMO

A 69-year-old man was referred to our department with acute hepatitis. He had been newly treated with benidipine hydrochloride for two months. His blood test results were as follows: aspartate aminotransferase, 1,614 IU/L; alanine aminotransferase, 1,091 IU/L and anti-smooth muscle antibody, ×80. Needle liver biopsy specimen showed interface hepatitis with mainly lymphocytic infiltration and bridging fibrosis in the periportal area. Immunohistochemistry revealed lymphocytic infiltration positive for IgG4. We diagnosed him with IgG4-related AIH with an etiology that was suspected of being drug-induced. Oral prednisolone was started and then tapered after achieving biochemical remission. Hepatitis recurred after the cessation of steroids; however, remission was achieved with ursodeoxycholic acid.


Assuntos
Hepatite Autoimune/tratamento farmacológico , Hepatite Autoimune/etiologia , Hepatite Crônica/tratamento farmacológico , Imunoglobulina G/sangue , Nifedipino/efeitos adversos , Nifedipino/uso terapêutico , Prednisolona/uso terapêutico , Idoso , Anti-Inflamatórios/uso terapêutico , Colagogos e Coleréticos/uso terapêutico , Hepatite Autoimune/diagnóstico , Humanos , Japão , Masculino , Nifedipino/análogos & derivados , Resultado do Tratamento , Ácido Ursodesoxicólico/uso terapêutico
17.
J Clin Transl Res ; 6(6): 236-240, 2020 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-33564728

RESUMO

BACKGROUND AND AIMS: Endoscopists and endoscopic assistants are easily exposed to germs, including COVID-19, during aerosol-generating procedures such as gastrointestinal endoscopy. This retrospective study investigated the utility of a box-shaped shielding device for reducing the risk of COVID-19 droplet infection during endoscopic procedures. METHODS: We created a cuboid box (500 × 650 × 450 mm) with four sides were covered with a transparent, vinyl-chloride sheet having two windows for endoscopic passage and assistance. The shielding box was then placed over a patient's head and shoulders and covered with another transparent vinyl sheet. We assessed its utility and safety using the medical data concerning the procedure time and vital signs and a questionnaire for the endoscopic staff and patients. RESULTS: We performed endoscopic retrograde cholangiopancreatography-related procedures using this device for two patients suspected of having COVID-19-associated pneumonia. Both patients were smoothly and successfully treated without any complications. No difficulties were noted with either endoscopic operation or in assisting the procedure, and the transparency was good enough to observe the patients' faces and movements. CONCLUSIONS: This box-shaped shielding device can be used to reduce the risk of COVID-19 droplet infection during endoscopic procedures in the clinical setting. RELEVANCE FOR PATIENTS: The COVID-19 outbreak has reminded healthcare personnel working in endoscopy units of the importance of infection prevention during endoscopy. The box-shaped shielding device can help endoscopic staff avoid hospital-setting COVID-19 infection.

18.
Clin J Gastroenterol ; 13(3): 382-385, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31786734

RESUMO

An 81-year-old man was diagnosed with Goodpasture syndrome (GS) because he met the criteria of positive anti-GBM antibodies, rapid progressive glomerulonephritis and pulmonary hemorrhage. After starting plasmapheresis and steroid pulse therapy, he experienced tarry stool and contrast-enhanced CT revealed an aneurysmal finding in the jejunum. Paroral enteroscopy showed a jejunal Dieulafoy's lesion (DL) with gush-out hemorrhage. Hemostasis was successfully achieved by hemoclipping, and he then experienced no re-bleeding events. GS can present as a jejunal DL, and contrast-enhanced CT is useful for investigating the etiology and site of small intestinal bleeding, which can lead to smooth, effective endoscopic hemostasis.


Assuntos
Doença Antimembrana Basal Glomerular/complicações , Hemorragia Gastrointestinal/complicações , Doenças do Jejuno/complicações , Idoso de 80 Anos ou mais , Endoscopia Gastrointestinal/métodos , Hemorragia Gastrointestinal/diagnóstico por imagem , Técnicas Hemostáticas , Humanos , Doenças do Jejuno/diagnóstico por imagem , Masculino , Tomografia Computadorizada por Raios X
19.
Gastroenterology Res ; 12(6): 320-323, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31803313

RESUMO

An 89-year-old woman who was bedridden suffered repeated vomiting due to superior mesenteric artery syndrome (SMAS). We performed gastrojejunostomy via the magnetic compression anastomosis (MCA) technique because her situation was not improved by conservative therapy and because the operative risk was high. We prepared two neodymium magnets: a flat plate-shaped magnet (15 × 3 mm) and a ring-shaped magnet of the same size. The ring-shaped magnet which passed through a guidewire was pushed to the duodenum by an endoscope over the guidewire. The duodenal stricture was balloon-dilated in front of the magnet, and the magnet was pushed all together beyond the stricture and placed at the duodenojejunal junction. Subsequently, the flat plate-shaped magnet was delivered endoscopically to the stomach using a biopsy forceps. The magnets were attracted towards each other transmurally after one more flat plate-shaped magnet was added to the gastric-side magnet. Completion of gastrojejunostomy was confirmed while retrieving the magnets 10 days after starting compression. She has been asymptomatic for 1 month since anastomosis. Endoscopic gastrojejunostomy using MCA was an effective, low-invasive treatment for SMAS.

20.
Gastroenterology Res ; 12(5): 267-270, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31636778

RESUMO

Magnetic compression anastomosis (MCA) was developed as a low-invasive treatment for gastro-enteric or entero-enteric obstruction. A 72-year-old man underwent subtotal gastrectomy with Billroth II reconstruction for early gastric cancer. After the operation, he suffered from repeated aspiration pneumonia due to anastomotic obstruction caused by jejunal kinking at the efferent loop of anastomosis. We therefore performed jejunojejunostomy via the MCA technique, as his situation was not improved despite conservative therapy and he had a high reoperative risk. We prepared two flat plate-shaped neodymium magnets (15 × 3 mm) each with a small hole, and a nylon thread was passed through each hole. Each magnet was then delivered endoscopically to the anal side of the jejunal kinking, subsequently to the anastomosis, using biopsy forceps. The two magnets immediately became attracted towards each other transmurally. Oozing hemorrhage with clot at the mated magnets was observed 10 days after starting the compression. After retrieving the magnets, we confirmed the completion of jejunojejunostomy and then successfully achieved hemostasis of the anastomotic hemorrhage using argon plasma coagulation. The widely patent anastomosis was confirmed endoscopically 1 month after canalization; and he has been asymptomatic and able to eat a normal diet ever since. Endoscopic MCA is an effective, low-invasive treatment for anastomotic obstruction after subtotal gastrectomy. A standardized, safer procedure should be established for general use in the clinical setting.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...