Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Juntendo Iji Zasshi ; 68(4): 375-386, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-39021429

RESUMO

Objectives: In radiation therapy, the field-in-field (FIF) technique is used to prevent the administration of unnecessarily high doses to reduce toxicity. Recently, the FIF technique has been used for whole brain irradiation (WBI). Using the FIF technique, the volume that receives a higher than prescribed dose (hotspot) can be largely reduced; however, the treatment planning requires time. Therefore, to reduce the burden on the treatment planners, we propose a semiautomatic treatment planning method for the FIF technique. Methods: In the semiautomatic FIF technique, hotspot regions in a treatment plan without the FIF technique are identified three-dimensionally, and beams with blocks that cover the hotspot regions using a multileaf collimator (sub-beams) are automatically created. The sub-beams are added to the original plan, and weights are assigned based on the maximum dose of the original plan to decrease the doses in the hotspot regions. This method was applied to 22 patients previously treated with WBI, wherein treatment plans were originally created without the FIF technique. Results: In the semiautomatic FIF plans, the hotspots almost disappeared. The dose to 95% of the volume and the volume receiving at least 95% of the prescribed dose in the planning target volume decreased by only 0.3% ± 0.2% and 0.0% ± 0.1%, respectively, on average compared with those in the original plan. The average semiautomatic FIF processing time was 28 ± 4 s. Conclusions: The proposed method reduced the hotspot regions with a slight change in the target coverage.

2.
J Radiat Res ; 60(3): 401-411, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30929023

RESUMO

The purpose of this study was to quantify actual patient organ doses from megavoltage computed tomography (MVCT) using an MVCT beam model of a helical tomotherapy unit in a general treatment planning system (TPS). Dosimetric parameters (percentage depth dose, lateral beam profile, and longitudinal beam profile) of the MVCT beam were measured using Gafchromic EBT3 films (ISP Corporation, Wayne, NJ, USA) and used for beam modeling in a Pinnacle3 TPS (Philips, Amsterdam, Netherlands); this TPS is widely used with linear accelerators. The created beam model was adjusted and validated by assessing point doses in a cylindrical phantom in static and helical beam plans with fine, normal and coarse pitches. Maximum doses delivered to important organs from MVCT delivery for five clinical cases were calculated using the created beam model. The difference (average ± one standard deviation for all evaluation points) between calculated and measured doses was -0.69 ± 1.20% in the static beam plan. In the helical beam plan, the differences were 1.83 ± 2.65%, 1.35 ± 5.94% and -0.66 ± 8.48% for fine, normal and coarse pitches, respectively. The average maximum additional dose to important organs from MVCT in clinical cases was 0.82% of the prescribed dose. In conclusion, we investigated a method for quantifying patient organ dose from MVCT delivery on helical tomotherapy using an MVCT beam model in a general TPS. This technique enables estimation of the patient-specific organ dose from MVCT delivery, without the need for additional equipment.


Assuntos
Especificidade de Órgãos/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada Espiral , Calibragem , Relação Dose-Resposta à Radiação , Humanos , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
3.
Rinsho Shinkeigaku ; 46(4): 266-9, 2006 Apr.
Artigo em Japonês | MEDLINE | ID: mdl-16768093

RESUMO

We report a 53-year-old woman with severe Graves' ophthalmopathy accompanied by uncontrolled myasthenia gravis. She presented remarkable exophthalmos, chemosis, and restriction of eye movement. Despite plasma exchange, steroid pulse therapy, local injection of steroid, and irradiation, ocular symptoms did not ameliorate. Since optic neuropathy was seen, orbital decompression surgery was performed in the left eye. Bilateral chemosis was improved after the surgery. Five years after surgery, there was no ocular palsy in the operated left eye, but in the contralateral eye. For the good prognosis of the eye movement, orbital decompression might be recommended in the severe Graves' ophthalmopathy accompanied by the optic neuropathy and/or ophthalmoplegia with proptosis.


Assuntos
Oftalmopatia de Graves/complicações , Miastenia Gravis/complicações , Descompressão Cirúrgica , Feminino , Oftalmopatia de Graves/cirurgia , Humanos , Pessoa de Meia-Idade , Miastenia Gravis/cirurgia , Doenças do Nervo Óptico/complicações , Doenças do Nervo Óptico/cirurgia , Troca Plasmática , Índice de Gravidade de Doença , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...