Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 112
Filtrar
1.
Sci Rep ; 7(1): 17968, 2017 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-29269841

RESUMO

Burst Intensification by Singularity Emitting Radiation (BISER) is proposed. Singularities in multi-stream flows of emitting media cause constructive interference of emitted travelling waves, forming extremely localized sources of bright coherent emission. Here we for the first time demonstrate this extreme localization of BISER by direct observation of nano-scale coherent x-ray sources in a laser plasma. The energy emitted into the spectral range from 60 to 100 eV is up to ~100 nJ, corresponding to ~1010 photons. Simulations reveal that these sources emit trains of attosecond x-ray pulses. Our findings establish a new class of bright laboratory sources of electromagnetic radiation. Furthermore, being applicable to travelling waves of any nature (e.g. electromagnetic, gravitational or acoustic), BISER provides a novel framework for creating new emitters and for interpreting observations in many fields of science.

2.
J Synchrotron Radiat ; 24(Pt 1): 196-204, 2017 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-28009559

RESUMO

Direct metrology of coherent short-wavelength beamlines is important for obtaining operational beam characteristics at the experimental site. However, since beam-time limitation imposes fast metrology procedures, a multi-parametric metrology from as low as a single shot is desirable. Here a two-dimensional (2D) procedure based on high-resolution Fresnel diffraction analysis is discussed and applied, which allowed an efficient and detailed beamline characterization at the SACLA XFEL. So far, the potential of Fresnel diffraction for beamline metrology has not been fully exploited because its high-frequency fringes could be only partly resolved with ordinary pixel-limited detectors. Using the high-spatial-frequency imaging capability of an irradiated LiF crystal, 2D information of the coherence degree, beam divergence and beam quality factor M2 were retrieved from simple diffraction patterns. The developed beam metrology was validated with a laboratory reference laser, and then successfully applied at a beamline facility, in agreement with the source specifications.

3.
Sci Rep ; 5: 13436, 2015 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-26330230

RESUMO

We report, for the first time, that the energy of femtosecond optical laser pulses, E, with relativistic intensities I > 10(21) W/cm(2) is efficiently converted to X-ray radiation, which is emitted by "hot" electron component in collision-less processes and heats the solid density plasma periphery. As shown by direct high-resolution spectroscopic measurements X-ray radiation from plasma periphery exhibits unusual non-linear growth ~E(4-5) of its power. The non-linear power growth occurs far earlier than the known regime when the radiation reaction dominates particle motion (RDR). Nevertheless, the radiation is shown to dominate the kinetics of the plasma periphery, changing in this regime (now labeled RDKR) the physical picture of the laser plasma interaction. Although in the experiments reported here we demonstrated by observation of KK hollow ions that X-ray intensities in the keV range exceeds ~10(17) W/cm(2), there is no theoretical limit of the radiation power. Therefore, such powerful X-ray sources can produce and probe exotic material states with high densities and multiple inner-shell electron excitations even for higher Z elements. Femtosecond laser-produced plasmas may thus provide unique ultra-bright X-ray sources, for future studies of matter in extreme conditions, material science studies, and radiography of biological systems.

4.
Br J Radiol ; 87(1042): 20140030, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25117626

RESUMO

OBJECTIVE: To determine the prevalence and clinical features of pathologically proven incidental cancer (IC) detected by whole-body fluorine-18 fludeoxyglucose ((18)F-FDG) positron emission tomography (PET)/CT, as well as the incidence of false-positive and false-negative results. METHODS: We retrospectively reviewed reports derived from (18)F-FDG PET/CT images of 3079 consecutive patients with known or suspected malignancies for 3 years. Discrete focal uptake indicating IC was identified from reports as well as pathological or clinical diagnoses, and the clinical courses were investigated. The false-positive result was defined as uptake indicating IC but not pathologically confirmed as malignant during follow-up. The false-negative result was defined as pathologically proven IC detected by another modality at initial clinical work-up or diagnosed during the follow-up period. RESULTS: We found (18)F-FDG uptake indicating IC in 6.7% of all patients, and IC was pathologically proven in 2.2% of all patients. The most common sites were the colon, lung and stomach. The median survival duration of patients with IC was 42 months. The results were false positive in 4.5% of all patients, and the results were false negative in 2.3% of all patients. CONCLUSION: (18)F-FDG PET/CT is a valuable tool for detecting IC. The rates of false-positive and false-negative results are within acceptable range. ADVANCES IN KNOWLEDGE: This is the first report to describe the survival of patients with IC, and the detailed features of false-negative results at actual clinical settings.


Assuntos
Neoplasias Colorretais/diagnóstico por imagem , Achados Incidentais , Neoplasias Pulmonares/diagnóstico por imagem , Imagem Multimodal , Tomografia por Emissão de Pósitrons/métodos , Idoso , Idoso de 80 Anos ou mais , Erros de Diagnóstico , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Estudos Retrospectivos
5.
Rev Sci Instrum ; 83(5): 053502, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22667617

RESUMO

X-ray line spectra ranging from 17 to 77 keV were quantitatively measured with a Laue spectrometer, composed of a cylindrically curved crystal and a detector. Either a visible CCD detector coupled with a CsI phosphor screen or an imaging plate can be chosen, depending on the signal intensities and exposure times. The absolute sensitivity of the spectrometer system was calibrated using pre-characterized laser-produced x-ray sources and radioisotopes. The integrated reflectivity for the crystal is in good agreement with predictions by an open code for x-ray diffraction. The energy transfer efficiency from incident laser beams to hot electrons, as the energy transfer agency for specific x-ray line emissions, is derived as a consequence of this work.

6.
Phys Rev Lett ; 108(13): 135004, 2012 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-22540709

RESUMO

We demonstrate a new high-order harmonic generation mechanism reaching the "water window" spectral region in experiments with multiterawatt femtosecond lasers irradiating gas jets. A few hundred harmonic orders are resolved, giving µJ/sr pulses. Harmonics are collectively emitted by an oscillating electron spike formed at the joint of the boundaries of a cavity and bow wave created by a relativistically self-focusing laser in underdense plasma. The spike sharpness and stability are explained by catastrophe theory. The mechanism is corroborated by particle-in-cell simulations.

7.
Opt Express ; 19(5): 4560-5, 2011 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-21369288

RESUMO

Kα line emissions from Mo and Ag plates were experimentally studied using clean, ultrahigh-intensity femtosecond laser pulses. The absolute yields of Kα x-rays at 17 keV from Mo and 22 keV from Ag were measured as a function of the laser pulse contrast ratio and irradiation intensity. Significantly enhanced Kα yields were obtained for both Mo and Ag by employing high contrast ratios and irradiances. Conversion efficiencies of 4.28×10⁻5/sr for Mo and 4.84×10⁻5/sr for Ag, the highest values obtained to date, were demonstrated with contrast ratios in the range 10⁻¹° to 10⁻¹¹.


Assuntos
Lasers , Raios X , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação
8.
J Comp Pathol ; 143(2-3): 185-9, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20163802

RESUMO

A free-living, young adult, male Japanese raccoon dog (Nyctereutes procyonoides viverrinus) was rescued in Gifu, Japan in March 2009. The animal was weak and emaciated with neurological signs that included head tilt, tremor and tic. The brain showed no gross abnormality at necropsy, but microscopically there was severe meningoencephalitis associated with protozoa, which were morphologically consistent with the asexual developmental stage of Sarcocystis spp. The protozoa were immunohistochemically negative for Toxoplasma gondii and Neospora caninum, but reacted weakly with antiserum specific for Sarcocystis cruzi. Analysis of the partial 18S rRNA gene sequence revealed that the protozoa were most closely related to an unidentified Sarcocystis species that was isolated from the white-fronted goose (Anser albifrons).


Assuntos
Córtex Cerebral/parasitologia , Meningoencefalite/veterinária , Cães Guaxinins/parasitologia , Sarcocystis/isolamento & purificação , Sarcocistose/veterinária , Animais , Córtex Cerebral/patologia , Japão , Masculino , Meningoencefalite/parasitologia , Meningoencefalite/patologia , RNA de Protozoário/genética , RNA Ribossômico 18S/genética , Sarcocystis/genética , Sarcocistose/complicações , Sarcocistose/parasitologia
9.
Opt Lett ; 34(21): 3268-70, 2009 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-19881563

RESUMO

Polychromatic soft x-ray plasma sources were not previously considered to be among the sources suitable for the propagation based phase contrast imaging because of their comparatively large emission-zone size. In the current work a scheme based on the combination of soft x-ray emission of multicharged ions, generated by the interaction of femtosecond laser pulses with an ultrasonic jet of gas clusters, and an LiF crystal detector was used to obtain phase-enhanced high-resolution images of micro- and nanoscale objects in a wide field of view.

10.
Opt Lett ; 34(7): 941-3, 2009 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-19340178

RESUMO

We demonstrate high quality, single-shot in situ imaging of the focused Ag x-ray laser (XRL) at 13.9 nm with 700 nm spatial resolution by color center formation in LiF. The flux and intensity for the color center formation in LiF are evaluated from the experimental data. Comparisons with previous reports show that the threshold x-ray flux for the color center formation in LiF for the 13.9 nm, 7 ps Ag XRL is 3 orders of magnitude less than that with the 46.9 nm, 2 ns capillary discharge Ar XRL.

11.
Phys Rev Lett ; 103(23): 235003, 2009 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-20366154

RESUMO

Laser light reflection by a relativistically moving electron density modulation (flying mirror) in a wake wave generated in a plasma by a high intensity laser pulse is investigated experimentally. A counterpropagating laser pulse is reflected and upshifted in frequency with a multiplication factor of 37-66, corresponding to the extreme ultraviolet wavelength. The demonstrated flying mirror reflectivity (from 3 x 10(-6) to 2 x 10(-5), and from 1.3 x 10(-4) to 0.6 x 10(-3), for the photon number and pulse energy, respectively) is close to the theoretical estimate for the parameters of the experiment.

12.
Phys Rev Lett ; 99(4): 043004, 2007 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-17678361

RESUMO

The interaction of large Xe clusters with a soft x-ray laser pulse having a wavelength of 13.9 nm and an intensity of up to 2x10(10) W/cm2 was investigated using a time-of-flight ion mass spectrometer. The corresponding laser photon energy was sufficiently high to photoionize Xe 4d innershell electrons. It was found that Xe3+ ions (which result from double Auger decay of 4d vacancies) became the dominant final ionic product with increasing cluster size and x-ray intensity. This is in contrast to the results of synchrotron radiation experiments involving free Xe atoms, in which Xe2+ is the dominant resultant ion species. Possible mechanisms responsible for the enhancement of the double Auger transition probability in x-ray laser and cluster interaction are discussed.

13.
Phys Rev E Stat Nonlin Soft Matter Phys ; 72(3 Pt 2): 036413, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16241585

RESUMO

The emission of fundamental and harmonic radiation from the rear side of thin foils in the thickness range 50-460 nm irradiated by intense frequency doubled Ti:sapphire laser pulses of the duration of 150 fs and intensities up to a few 10(18) W/cm(2) was investigated. Following up a previous study of the rear side harmonic emission [Teubner, Phys. Rev. Lett. 92, 185001 (2004)], we measured the emission efficiencies, polarization properties, and the spectral shapes of the fundamental frequency and the second harmonic. Rear side emission is only observed when the obliquely incident laser light is p -polarized. Particle-in-cell (PIC) simulations indicate that the foils remain strongly overdense during the interaction with the laser pulse and that the rear side emission is caused by energetic electron bunches which are generated at the front side by resonance absorption. They are accelerated into the foil and drive strong plasma oscillations at the fundamental and higher harmonic frequencies.

14.
Phys Rev Lett ; 89(25): 257602, 2002 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-12484921

RESUMO

A picosecond x-ray laser speckle has been conducted to study the dynamics of a disordered surface domain structure (BaTiO3 with 90 degrees c/a domains) as a function of temperature for the first time. The transient surface structures induced by ferroelectric domains decrease as temperature increases towards the Curie temperature T(c) and completely disappear above T(c). The dramatic change of the spatial configuration of the c/a domains was observed to occur from a temperature 2 degrees C below T(c), near which the average correlated domain size at equilibrium decreases as (T(c)-T)(0.37+/-0.02).

15.
J Synchrotron Radiat ; 5(Pt 3): 756-8, 1998 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-15263643

RESUMO

Absolute calibration of a soft X-ray spectrograph has been performed using a white beam of synchrotron radiation. The calibrated spectrograph was a flat-field grazing-incidence spectrograph with an X-ray CCD detector for X-ray laser research. Absolute sensitivity of the spectrograph system can be obtained from transmitted spectra using filters made of several different materials, each providing an absorption-edge wavelength standard. The absolute sensitivity determined in this work shows nearly the same behaviour with wavelength as that in another calibration experiment using a laser-produced plasma as an X-ray source.

18.
Leuk Res ; 19(6): 407-9, 1995 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-7596153

RESUMO

Tissue polypeptide antigen (TPA) in serum was measured at diagnosis in 27 patients with acute nonlymphocytic leukemia (ANLL) (1 FAB M0, 1 M1, 10 M2, 7 M3, 5 M4, 1 M5, 1 M6 and 1 MU). Statistical analysis disclosed a close correlation of TPA level with age (P < 0.01), hemoglobin level (P < 0.05), therapeutic response (P < 0.01) and the length of survival after the initial diagnosis (P < 0.02). A significant difference in TPA level was present between patients with complete remission and those with poor response. To our knowledge, this is the first report to prove a correlation of TPA level with therapeutic response and the length of survival in ANLL.


Assuntos
Antígenos de Neoplasias/sangue , Biomarcadores Tumorais/sangue , Leucemia Mieloide Aguda/sangue , Peptídeos/sangue , Adolescente , Adulto , Idoso , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Células da Medula Óssea , Feminino , Hemoglobinas/metabolismo , Humanos , Leucemia Mieloide Aguda/tratamento farmacológico , Masculino , Pessoa de Meia-Idade , Contagem de Plaquetas , Valor Preditivo dos Testes , Prognóstico , Valores de Referência , Antígeno Polipeptídico Tecidual , Resultado do Tratamento
19.
Leukemia ; 9(4): 594-7, 1995 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-7723390

RESUMO

To clarify the clinical and biological significance of beta 2-microglobulin (beta 2-M) in serum of adult T cell leukemia (ATL) associated with human lymphotropic virus type-I (HTLV-I), beta 2-M was measured in 52 patients with ATL (acute ATL, 35 patients; lymphoma ATL, two patients; chronic ATL, 12 patients; smoldering ATL, three patients), and it was compared with serum lactic dehydrogenase (LDH). Statistical analysis disclosed a correlation between beta 2-M level and the percentage of abnormal lymphocytes (P < 0.05) and platelet count (P < 0.01). There was a correlation between LDH and platelet count (P < 0.01), and a tendency of correlation between LDH and the percentage of abnormal lymphocytes (P < 0.15). Significant difference was present in beta 2-M as well as LDH between acute ATL and chronic ATL (P < 0.01), and between acute ATL and smoldering ATL (P < 0.01). We also investigated a significant inverse correlation between beta 2-M level as well as LDH level and the length of survival after the initial diagnosis (P < 0.01). Thus, the beta 2-M level may indicate the aggressiveness of ATL cells and predict the length of survival.


Assuntos
Leucemia de Células T/sangue , Microglobulina beta-2/metabolismo , Adulto , Idoso , Feminino , Humanos , L-Lactato Desidrogenase/sangue , Leucemia de Células T/diagnóstico , Linfócitos/patologia , Masculino , Pessoa de Meia-Idade , Contagem de Plaquetas , Análise de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...