1.
Mass Spectrom (Tokyo) ; 8(1): A0073, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32010541

RESUMO

Isotope labeling measurements using mass spectrometry can provide informative insights on the metabolic systems of various organisms. The detailed identification of carbon positions included in the fragment ions of dicarboxylic and tricarboxylic acids in central carbon metabolism is needed for precise interpretation of the metabolic states. In this study, fragment ions containing the carbon backbone cleavage of dicarboxylic and tricarboxylic in the Krebs cycle were investigated by using gas chromatography (GC)-electron ionization (EI)-MS and GC-EI-MS/MS. The positions of decarboxylation in the dicarboxylic and tricarboxylic acids were successfully identified by analyses using position-specific 13C-labeled standards prepared by in vitro enzymatic reactions. For example, carboxyl groups of C1 and C6 of trimethylsilyl (TMS)- and tert-butyldimethylsilyl (TBDMS)-derivatized malic and citric acids were primarily cleaved by EI. MS/MS analyses were also performed, and fragment ions of TBDMS-citric and α-ketoglutaric acids (αKG) with the loss of two carboxyl groups in collision-induced dissociation (CID) were observed.

2.
Metab Eng ; 51: 43-49, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30176394

RESUMO

Precise measurement of sugar phosphates in glycolysis and the pentose phosphate (PP) pathway for 13C-metabolic flux analysis (13C-MFA) is needed to understand cancer-specific metabolism. Although various analytical methods have been proposed, analysis of sugar phosphates is challenging because of the structural similarity of various isomers and low intracellular abundance. In this study, gas chromatography-negative chemical ionization-mass spectrometry (GC-NCI-MS) is applied to sugar phosphate analysis with o-(2,3,4,5,6-pentafluorobenzyl) oxime (PFBO) and trimethylsilyl (TMS) derivatization. Optimization of the GC temperature gradient achieved baseline separation of sugar phosphates in 31 min. Mass spectra showed the predominant generation of fragment ions containing all carbon atoms in the sugar phosphate backbone. The limit of detection of pentose 5-phosphates and hexose 6-phosphates was 10 nM. The method was applied to 13C-labeling measurement of sugar phosphates for 13C-MFA of the MCF-7 human breast cancer cell line. 13C-labeling of sugar phosphates for 13C-MFA improved the estimation of the net flux and reversible flux of bidirectional reactions in glycolysis and the PP pathway.


Assuntos
Linhagem Celular Tumoral , Análise do Fluxo Metabólico/métodos , Fosfatos Açúcares/análise , Metabolismo Energético , Feminino , Fluorbenzenos , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Isomerismo , Células MCF-7 , Oximas , Espectrometria de Massas por Ionização por Electrospray , Compostos de Trimetilsilil/metabolismo
3.
Sci Rep ; 8(1): 17915, 2018 12 17.
Artigo em Inglês | MEDLINE | ID: mdl-30559391

RESUMO

D-amino acids (D-AAs) have various biological activities, such as activation of N-methyl-D-aspartic acid (NMDA) receptor as a co-agonist by D-Ser. Since several free D-AAs are released in the broth monocultured with bacterium and D-AAs are probably utilized for bacterial communication, we presume that intestinal microbiota releases several kinds of free D-AAs, which may be involved in the hosts' health. However, presently, only four free D-AAs have been found in the ceacal lumen, but not in the colonic lumen. Here, we showed, by simultaneous analysis of chiral AAs using high-sensitivity liquid chromatography-tandem mass spectrometry (LC-MS/MS), that 12 free D-AAs (D-Ala, D-Arg, D-Asp, D-Gln, D-Glu, D-allo-Ile, D-Leu, D-Lys, D-Met, D-Phe, D-Ser, and D-Trp) are produced by intestinal microbiota and identified bacterial groups belonging to Firmicutes as the relevant bacterial candidates.


Assuntos
Aminoácidos/metabolismo , Bactérias/metabolismo , Microbioma Gastrointestinal/fisiologia , Intestinos/microbiologia , Animais , Cromatografia Líquida/métodos , Camundongos , Camundongos Endogâmicos ICR , Espectrometria de Massas em Tandem/métodos
4.
Oncotarget ; 8(10): 17115-17126, 2017 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-28179577

RESUMO

In developed countries, the number of patients with colorectal cancer has been increasing, and colorectal cancer is one of the most common causes of cancer death. To improve the quality of life of colorectal cancer patients, it is necessary to establish novel screening methods that would allow early detection of colorectal cancer. We performed metabolome analysis of a plasma sample set from 282 stage 0/I/II colorectal cancer patients and 291 healthy volunteers using gas chromatography/triple-quadrupole mass spectrometry in an attempt to identify metabolite biomarkers of stage 0/I/II colorectal cancer. The colorectal cancer patients included patients with stage 0 (N=79), I (N=80), and II (N=123) in whom invasion and metastasis were absent. Our analytical system detected 64 metabolites in the plasma samples, and the levels of 29 metabolites differed significantly (Bonferroni-corrected p=0.000781) between the patients and healthy volunteers. Based on these results, a multiple logistic regression analysis of various metabolite biomarkers was carried out, and a stage 0/I/II colorectal cancer prediction model was established. The area under the curve, sensitivity, and specificity values of this model for detecting stage 0/I/II colorectal cancer were 0.996, 99.3%, and 93.8%, respectively. The model's sensitivity and specificity values for each disease stage were >90%, and surprisingly, its sensitivity for stage 0, specificity for stage 0, and sensitivity for stage II disease were all 100%. Our predictive model can aid early detection of colorectal cancer and has potential as a novel screening test for cases of colorectal cancer that do not involve lymph node or distant metastasis.


Assuntos
Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/metabolismo , Detecção Precoce de Câncer/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Metaboloma , Metabolômica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais/sangue , Biomarcadores Tumorais/metabolismo , Neoplasias Colorretais/sangue , Feminino , Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes
5.
Anal Bioanal Chem ; 408(22): 6133-40, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27342798

RESUMO

Stable isotope labeling experiments using mass spectrometry have been employed to investigate carbon flow levels (metabolic flux) in mammalian, plant, and microbial cells. To achieve a more precise (13)C-metabolic flux analysis ((13)C-MFA), novel fragmentations of tert-butyldimethylsilyl (TBDMS)-amino acids were investigated by gas chromatography-tandem mass spectrometry (GC-MS/MS). The product ion scan analyses of 15 TBDMS-amino acids revealed 24 novel fragment ions. The amino acid-derived carbons included in the five fragment ions were identified by the analyses of (13)C-labeled authentic standards. The identification of the fragment ion at m/z 170 indicated that the isotopic abundance of S-methyl carbon in methionine could be determined from the cleavage of C5 in the precursor of [M-159](+) (m/z 218). It was also confirmed that the precision of (13)C-MFA in Escherichia coli central carbon metabolism could be improved by introducing (13)C-labeling data derived from novel fragmentations. Graphical Abstract Novel collision-induced dissociation fragmentations of tert-butyldimethylsilyl amino acids were investigated and identified by GC-MS/MS.


Assuntos
Aminoácidos/metabolismo , Escherichia coli/metabolismo , Cromatografia Gasosa-Espectrometria de Massas/métodos , Análise do Fluxo Metabólico/métodos , Aminoácidos/análise , Carbono/análise , Carbono/metabolismo , Escherichia coli/química , Compostos de Organossilício/análise , Compostos de Organossilício/metabolismo , Espectrometria de Massas em Tandem
6.
J Chromatogr B Analyt Technol Biomed Life Sci ; 878(30): 3113-8, 2010 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-20971689

RESUMO

A simple and rapid method for quantitative analysis of amino acids, including valine (Val), leucine (Leu), isoleucine (Ile), methionine (Met) and phenylalanine (Phe), in whole blood has been developed using GC/MS. In this method, whole blood was collected using a filter paper technique, and a 1/8 in. blood spot punch was used for sample preparation. Amino acids were extracted from the sample, and the extracts were purified using cation-exchange resins. The isotope dilution method using ²H8-Val, ²H3-Leu, ²H3-Met and ²H5-Phe as internal standards was applied. Following propyl chloroformate derivatization, the derivatives were analyzed using fast-GC/MS. The extraction recoveries using these techniques ranged from 69.8% to 87.9%, and analysis time for each sample was approximately 26 min. Calibration curves at concentrations from 0.0 to 1666.7 µmol/l for Val, Leu, Ile and Phe and from 0.0 to 333.3 µmol/l for Met showed good linearity with regression coefficients=1. The method detection limits for Val, Leu, Ile, Met and Phe were 24.2, 16.7, 8.7, 1.5 and 12.9 µmol/l, respectively. This method was applied to blood spot samples obtained from patients with phenylketonuria (PKU), maple syrup urine disease (MSUD), hypermethionine and neonatal intrahepatic cholestasis caused by citrin deficiency (NICCD), and the analysis results showed that the concentrations of amino acids that characterize these diseases were increased. These results indicate that this method provides a simple and rapid procedure for precise determination of amino acids in whole blood.


Assuntos
Aminoácidos/sangue , Deutério/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Técnicas de Diluição do Indicador , Humanos
7.
J Chromatogr B Analyt Technol Biomed Life Sci ; 878(13-14): 942-8, 2010 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-20303325

RESUMO

GC/MS is widely used for the analysis of urinary organic acids for the chemical diagnosis of organic acidurias such as methylmalonic acidemia, propionic acidemia, isovaleric acidemia, glutaric aciduria type I, and multiple carboxylase deficiency. In this study, a rapid and simple preparation method for this analysis was developed in order to improve the laboratory productivity and the working environment. The solvent extraction and trimethylsilyl derivatization steps of the conventional method were improved by reducing the volume of urine sample and extraction solvent and by applying the flash-heater derivatization, respectively. The new method was successfully applied to the chemical diagnoses of five organic acidurias.


Assuntos
Ácidos/urina , Cromatografia Gasosa-Espectrometria de Massas/métodos , Erros Inatos do Metabolismo/diagnóstico , Humanos , Padrões de Referência
8.
Clin Chim Acta ; 392(1-2): 34-40, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18381205

RESUMO

BACKGROUND: Gas chromatograph mass-spectrometric (GC/MS) method of analysis for urinary organic acids is used for the diagnosis of a variety of metabolic disorders. The method is time-consuming and does not allow for improvements in sample throughput. Although the sample preparation and the data processing have been improved, the long GC/MS analysis time still remains to be problematic. METHODS: The fast-GC/MS method, which utilizes a short microbore capillary GC column and fast temperature programming, was applied to the analysis for urinary organic acids. Urine samples obtained from 15 patients with 9 different disorders and 16 healthy controls were analyzed using conventional GC/MS and fast-GC/MS. RESULTS: Analysis cycle time was shortened from 1 h to 15 min. The automated data system uses retention indices determined by conventional-GC/MS for the identification of 134 organic acids. These retention indices can also be used in data obtained by fast-GC/MS. New fast-GC/MS method with the automated data system gave the same diagnostic results as conventional-GC/MS except for 1 healthy control. CONCLUSIONS: The combined system of fast-GC/MS and the automated data system will be powerful tools in clinical laboratories due to increased sample throughput and reduced analysis costs.


Assuntos
Ácidos Carboxílicos/urina , Cromatografia Gasosa-Espectrometria de Massas/métodos , Doenças Metabólicas/diagnóstico , Humanos , Doenças Metabólicas/urina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...