Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Dent Mater J ; 38(3): 418-423, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-30814451

RESUMO

The purpose of the present study was to examine the effects of silane coupling treatment and airborne-particle abrasion (APA) on shear bond strength (SBS) between photo-cured bulk-fill flowable composite resin and 12% silver-palladium-copper-gold (Ag-Pd-CuAu) alloy using self-adhesive resin cement. The six experimental groups were compared using two-way analysis of variance (ANOVA) followed by Tukey Kramer's post-hoc test to compare SBS values among the six groups at a 95% confidence level. The SBS of APA groups was significantly higher than non-APA groups. The SBS of the specimens with silane coupling treatment increased slightly compared with specimens without silane coupling treatment. The combination of resin coating with bulk-fill resin and self-adhesive resin cement could be clinically useful when restoring a cavity with a noble metal.


Assuntos
Colagem Dentária , Cimentos de Resina , Óxido de Alumínio , Resinas Compostas , Cobre , Cimentos Dentários , Ligas de Ouro , Teste de Materiais , Metacrilatos , Resistência ao Cisalhamento , Silanos , Estresse Mecânico , Propriedades de Superfície
2.
Lasers Med Sci ; 34(1): 99-105, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30091060

RESUMO

We aimed at examining the effects of a percentage of air/water in spray on the cutting efficiency of Er,Cr:YSGG laser for enamel and dentin. The intensity and frequency of irradiation were 3.0 W and 20 Hz for the enamel surface and 2.0 W and 20 Hz for the dentin surface, respectively. Flattened surfaces of enamel and dentin were irradiated at nine points for approximately 1 s under various percentages of air/water in spray using Er,Cr:YSGG laser. A high-speed video microscope was used to record each laser irradiation on the tooth surface. A slow video image was used to count the number of water micro-explosions yielded on the tooth surface during laser irradiation. A surface roughness tester was used to measure the depth of the dimple prepared with laser irradiation on each specimen. Each individual depth of dimple was divided by the number of water micro-explosions (pulse). This allowed for the calculation of the cutting depth per pulse. Following laser irradiation, several representative specimens were observed using an SEM. Two-way ANOVA was used as the statistical analysis. This revealed that there was no significant effect of the percentage of air/water in spray on the cutting depth for enamel surface (p > 0.05). On the contrary, a significant effect was observed in air-ratio for dentin cutting (p < 0.05). Both enamel and dentin were characterized by the presence of rough surfaces, as shown by the SEM images of the dimples. The percentage of air/water in spray was not significantly effective in laser cutting for enamel. Air-percentage was significantly effective in laser cutting for dentin.


Assuntos
Técnicas de Ablação , Ar , Cromo/química , Érbio/química , Lasers de Estado Sólido , Dente/efeitos da radiação , Água/química , Esmalte Dentário/efeitos da radiação , Esmalte Dentário/ultraestrutura , Dentina/efeitos da radiação , Humanos
3.
Aust Endod J ; 45(2): 265-273, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30402989

RESUMO

This report shows the healing process of an exposed pulp carbonised by CO2 laser irradiation prior to the application of a capping material. Six intact teeth from four volunteers were irradiated by CO2 laser and randomly capped with either an adhesive resin (SE bond) (n = 3) or calcium hydroxide-based cement (Dycal) (n = 3). The laser was operated in super-pulsed mode (power output, 0.5 W) for an irradiation time of 30 s. All cavities were restored with composite resin. Each tooth was extracted at approximately 30, 50 or 260 days post treatment and prepared for histological evaluation. CO2 laser irradiation controlled exudate and bleeding from each exposed pulp. Histological images revealed Dycal promoted complete dentine bridge formation at the carbonised pulp surface, and laser energy affected not only the pulp surface but also the deeper part of the pulp chamber.


Assuntos
Capeamento da Polpa Dentária , Dentina Secundária , Hidróxido de Cálcio , Dióxido de Carbono , Polpa Dentária , Humanos , Cimentos de Resina
4.
J Appl Oral Sci ; 26: e20160652, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29412366

RESUMO

The relationship between wear resistance and filler size or filler loading was clarified for the universal resin composite; however, their relationship in flowable resin composites has not been clarified. The purpose of this study was to investigate the effect of filler size and filler loading on wear of experimental flowable resin composites by using a cyclic loading device. Nine experimental flowable resin composites consisting of three different sizes (70, 200 and 400 nm) and loading (50, 55 and 60 wt%) of filler were prepared. Bowl-shaped cavities were prepared on a flat surface of ceramic blocks using a No. 149 regular cut diamond point. The cavities were treated with a silane coupling agent and an all-in-one adhesive and then filled with each experimental flowable resin composite. The restored surfaces were finished and polished with a 1500-grit silicon carbide paper. The specimens were subjected to an in vitro two-body wear test using a cyclic loading device. The localized worn surfaces were evaluated at 10,000, 20,000, 30,000, and 40,000 cycles using a computer-controlled three-dimensional measuring microscope (n=5). The volumetric wear loss of the materials was calculated automatically by the equipment. Data were statistically analyzed with two-way ANOVA and post hoc Tukey test. Two-way ANOVA showed that the filler size significantly influenced wear volume (p<0.003), but the filler loading did not have a significant effect (p>0.05). A post hoc Tukey test detected significant differences in filler size between 70 nm and 400 nm, and 200 nm and 400 nm (p<0.007). The experimental flowable resin composite containing a mean filler size of 400 nm exhibited significantly lower wear resistance in two-body wear compared with those containing mean filler sizes of 200 nm or 70 nm.


Assuntos
Resinas Compostas/química , Desgaste de Restauração Dentária , Metacrilatos/química , Cimentos de Resina/química , Análise de Variância , Teste de Materiais , Microscopia Eletrônica de Varredura , Tamanho da Partícula , Valores de Referência , Reprodutibilidade dos Testes , Propriedades de Superfície , Fatores de Tempo
5.
J. appl. oral sci ; 26: e20160652, 2018. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-893729

RESUMO

Abstract The relationship between wear resistance and filler size or filler loading was clarified for the universal resin composite; however, their relationship in flowable resin composites has not been clarified. Objectives: The purpose of this study was to investigate the effect of filler size and filler loading on wear of experimental flowable resin composites by using a cyclic loading device. Material and Methods: Nine experimental flowable resin composites consisting of three different sizes (70, 200 and 400 nm) and loading (50, 55 and 60 wt%) of filler were prepared. Bowl-shaped cavities were prepared on a flat surface of ceramic blocks using a No. 149 regular cut diamond point. The cavities were treated with a silane coupling agent and an all-in-one adhesive and then filled with each experimental flowable resin composite. The restored surfaces were finished and polished with a 1500-grit silicon carbide paper. The specimens were subjected to an in vitro two-body wear test using a cyclic loading device. The localized worn surfaces were evaluated at 10,000, 20,000, 30,000, and 40,000 cycles using a computer-controlled three-dimensional measuring microscope (n=5). The volumetric wear loss of the materials was calculated automatically by the equipment. Data were statistically analyzed with two-way ANOVA and post hoc Tukey test. Results: Two-way ANOVA showed that the filler size significantly influenced wear volume (p<0.003), but the filler loading did not have a significant effect (p>0.05). A post hoc Tukey test detected significant differences in filler size between 70 nm and 400 nm, and 200 nm and 400 nm (p<0.007). Conclusion: The experimental flowable resin composite containing a mean filler size of 400 nm exhibited significantly lower wear resistance in two-body wear compared with those containing mean filler sizes of 200 nm or 70 nm.


Assuntos
Resinas Compostas/química , Cimentos de Resina/química , Desgaste de Restauração Dentária , Metacrilatos/química , Tamanho da Partícula , Valores de Referência , Propriedades de Superfície , Fatores de Tempo , Teste de Materiais , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Análise de Variância
6.
Dent Mater J ; 36(3): 348-356, 2017 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-28190811

RESUMO

The aim of this study was to histologically evaluate direct pulp capping using different all-in-one adhesives in rat teeth. Five all-in-one adhesives and a control material (MTA) were used. Each material was applied on the exposed pulp, and each cavity was subsequently restored with the resin composite. Rats were sacrificed 14 days after the surgical procedure. Serial stained sections were histologically evaluated for examining pulp tissue disorganization (PTD), inflammatory cell infiltration (ICI), dentin bridge formation (DBF), and bacterial penetration (BP). We found that rat pulps, which were direct capped with all-in-one adhesives, showed various degrees of PTD, ICI, and DBF depending on the material, and that there were no complete dentin bridges. In contrast, rat pulps capped with MTA showed no PTD and ICI, and there were complete dentin bridges in all, but one specimen. No BP was observed in any specimen.


Assuntos
Adesivos , Capeamento da Polpa Dentária , Animais , Hidróxido de Cálcio , Polpa Dentária , Exposição da Polpa Dentária , Dentina Secundária , Ratos , Cimentos de Resina
7.
Dent Mater J ; 35(3): 479-89, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27252005

RESUMO

The purpose of this study was to evaluate pulpal healing and reparative dentin formation after 14 and 28 days in exposed rat pulp directly capped with an experimentally developed all-in-one adhesive containing surface reaction-type pre-reacted glass-ionomer (S-PRG) filler. The four experimental groups and the control group were compared using the Kruskal-Wallis test, followed by the Steel-Dwass post-hoc test to compare the histopathological score. The Mann-Whitney U test was used to compare the histopathological score at 14 and 28 days for each observation item. All experimental adhesives containing S-PRG fillers developed for direct pulp capping showed no pulpal inflammation. After 14 days, the experimental adhesives containing S-PRG fillers and the control group formed tertiary dentin around the exposed pulp. After 28 days, the experimental adhesives containing 13 and 27 wt% of S-PRG fillers formed dentin bridge equal to the control.


Assuntos
Cimentos Dentários , Capeamento da Polpa Dentária , Animais , Hidróxido de Cálcio , Polpa Dentária , Dentina Secundária , Ratos , Cimentos de Resina
8.
Dent Mater J ; 34(6): 841-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26632233

RESUMO

We aimed to evaluate the microtensile bond strength (µTBS) of experimentally developed all-in-one adhesives containing surface reaction-type pre-reacted glass-ionomer (S-PRG) filler as a direct pulp-capping agent. Flattened dentin surfaces of extracted human molars were treated with four experimental adhesives of different S-PRG filler content (group 1: 0 wt%, group 2: 13 wt%, group 3: 27 wt% and group 4: 40 wt%) and Fluorobond Shakeone as the control. The beam samples were made and attached to the testing device, placed onto the tabletop-material-tester, and subjected to µTBS test. The data were statistically analyzed using one-way ANOVA. The results demonstrated that the µTBS value of group 2 was significantly lower than that of the control. No other significant differences among the µTBS values of groups and control were observed. It was concluded that the µTBS values of the experimental adhesives were not affected by the S-PRG filler contents except in group 2.


Assuntos
Adesivos Dentinários/química , Cimentos de Resina/química , Materiais Restauradores do Canal Radicular/química , Colagem Dentária , Cimentos Dentários , Capeamento da Polpa Dentária , Fluoretos Tópicos , Humanos , Técnicas In Vitro , Teste de Materiais , Dente Molar , Propriedades de Superfície , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...